A candid, well-instrumented engineering paper whose turn-end, latency, PII and LID numbers check out (we reproduced turn-end AUROC 0.953 on public Smart Turn data), but the released package is not the calibrated lexical system that was evaluated, the FLEURS term-choice results in Table 1 and Fig. 3 are statistically incompatible, the single-encoder-pass claim fails on short inputs, and most evaluation artifacts are unreleased.
Soundness
2/4
Presentation
3/4
Contribution
2/4
Confidence
4/5
✓ 11 confirmed✕ 4 discrepancy◐ 1 inconclusive
Summary
The paper presents marimba, a request-time interface that answers typed questions (yes/no, multiple choice, score) about an 8-second speech window using a frozen Qwen3-ASR-0.6B model. Lexical questions ("was term X said?", "which of these terms?") are scored zero-shot as the fraction of five decoder hypotheses (greedy + 4-beam) that contain the normalized term, mapped to a probability with Platt scaling. Non-lexical questions use small frozen-feature readouts: a question-conditioned cross-attention head (voice activity), a layer-18 logistic turn-end readout, layer-12 speaker readouts (same speaker, speaker change, speaker count), and the ASR model's own language-token scores for language identification.
The evaluation covers private Brazilian Portuguese clinical consultations (term spotting with medication-confusion hard negatives and held-out terms), public read speech (Common Voice, FLEURS, Speech Commands), AMI/VoxConverse (VAD, speaker tasks), Smart Turn v3.2 and ICSI (turn end), synthetic pt-BR PII speech, CochlScene (an unseen task, at chance), a 1,000-question paired comparison against Qwen3-Omni-30B and Qwen2-Audio-7B, and L4 latency. The headline claims are: lexical AUROC 0.80–0.92 (private) and 0.92–0.97 (public); turn end 0.930 vs Smart Turn v3.2 0.982 in-distribution and a statistical tie on ICSI; speaker readouts at or above ECAPA/pyannote 3.1; and per-question p95 latency of 13–16 ms on the encoder lanes.
Strengths
Candid reporting of negative and limiting results
Table 2; Table 3; Sec. 6.1; Sec. 7
The paper reports results that do not favour the method: CochlScene scene classification at chance (Table 2, Sec. 6 'Unseen tasks'); Platt calibration worsening turn-end ECE (0.034 → 0.041, Table 3); ICSI described as a tie that is 'not evidence of advantage or equivalence'; losses to Qwen3-Omni on Speech Commands and Common Voice LID (Sec. 6.1); a 2.35 s p95 term latency. The Limitations section (Sec. 7) names the weakest points itself.
Uncertainty quantified throughout, and the reported statistics are internally consistent
Tables 1, 3, 4; Sec. 6 'Language identification', 'Personal information'
Clustered bootstrap CIs (Tables 1, 3, 4), paired CIs for the turn-end comparisons, and Wilson CIs for LID. We recomputed the turn-end gaps (−0.052, +0.004; check 03), all three LID Wilson intervals exactly (check 10), the PII P/R/F1 and both bootstrap CIs from reconstructed integer counts (check 09), and the Table 1 ranges and GRIM feasibility of all 12 accuracies (check 01). All agree.
Turn-end readout reproduces, and does better than reported, on public data
Table 3; Sec. 5.3
Running the released weights on 500 seeded clips from the public Smart Turn v3.2 test set gave AUROC 0.953 [0.935, 0.970] and 10-bin ECE 0.037. The paper reports 0.930 [0.906, 0.951] and ECE 0.041 (check 16; two-sample z = +1.58). The paper's 500-clip subset is not identified, so this is a distributional rather than an exact replication.
Latency claims backed by raw released timings
Sec. 6 'Latency'; docs/benchmarks.md
benchmarks/l4_e2e_latency.json contains 1,100 per-call timings. All 16 reported p50/p95 values and bootstrap bounds reproduce to 0.01 ms with the documented seed (check 08). Few systems papers release latency evidence at this granularity.
Meaningful hard-negative design for clinical term spotting
Sec. 3.4; Table 1
Hard negatives come from real medication-confusion pairs and phonetic near-misses, with a held-out term list (Sec. 3.4, Table 1). The released lexical code correctly rejects inflected near-misses such as 'coloca' for 'colocar' (check 02). This is a more demanding test than random distractors.
Readable release whose non-lexical readouts match the paper
Sec. 5.3–5.5; src/marimba/readout.py, _diarization.py, language.py
The code implements the described turn-end readout (layer 18, valid-frame tail pooling over the last 2 s, Platt), the layer-12 speaker readouts (4 s halves; 6 s/2 s split with a one-hidden-layer MLP; mean+std count features) and 30-language LID with a softmax over options (check 11). The default test suite passes: 319 passed, 0 failed (check 13). On the example clips the model behaves sensibly (7 of 8 match their labels, check 07).
Weaknesses
The released package is not the evaluated lexical system
major · Sec. 1 para 4; Sec. 5.2; Fig. 1; Table 1; src/marimba/pretrained.py:99-100, capabilities.py
Sec. 1, Sec. 5.2, Fig. 1 and the abstract describe lexical scores 'calibrated with Platt scaling' and a four-way term-choice decision with fuzzy tie-break. Table 1's ECE (≤ 0.08) and 4-way accuracies depend on both. In the release, pretrained.py:99-100 rejects any manifest whose term calibration is not none. Term kinds are only yes/no (capabilities.py), so term choice is unsupported, and no fuzzy tie-break exists. docs/capabilities.md:30-31 states that the 'historical decoder study's calibrated lexical scores must not be substituted' for the raw fractions. The released term score takes only six values {0, 0.2, …, 1.0} (check 02). The calibration and choice results in Table 1 therefore have no released counterpart. Fix: release the fitted Platt maps and the choice/tie-break code, or state in the abstract and Sec. 5.2 that Table 1 describes a different, unreleased configuration. Also report the uncalibrated release's ECE.
FLEURS term results in Table 1 and the paired comparison are incompatible
major · Table 1 (FLEURS row); Sec. 6.1; Fig. 3; Abstract
Table 1 reports FLEURS term choice accuracy 1.00 on 477 questions, so at least 475 were correct. Fig. 3 and the README report 0.855 (= 53/62) for the same zero-shot lane. Under Table 1's accuracy, P(X ≤ 53 | n = 62, p = 0.995) = 3.1 × 10⁻¹¹. FLEURS binary AUROC is 0.970 in Table 1 vs 0.901 in Fig. 3 (z = 1.7–2.7 depending on class balance). The Common Voice and Speech Commands rows agree across the two evaluations (check 04). The two FLEURS evaluations therefore cannot be samples of the same question distribution answered by the same system, and the paper does not explain the difference (distractor construction, clip length, normalization). The abstract's 'public read speech 0.92–0.97' is drawn only from Table 1; the paired values (0.901, 0.907) fall below it. Fix: document how the two question sets were built. If they differ in difficulty, report both in the abstract or explain which one represents the system.
'One encoder pass per window' does not hold for short inputs; the repo's own test fails
major · Sec. 1 para 4; Sec. 5.1; Sec. 8; src/marimba/windows.py, pretrained.py:141-160; tests/test_pretrained.py:722-736
Sec. 1, Sec. 5.1 and Sec. 8 state that a frozen encoder processes each 8 s window once and that all questions share it. With a hook on the audio tower, a full 8 s file with mixed questions uses 1 pass. Inputs shorter than 8 s (1 s silence; 4.46 s speech), which the API left-pads, use 2 passes, because the decoder lane re-encodes a shifted snapshot (, check 07). The repository's own real-model test () fails on the pinned release with (check 13). The latency benchmark also times one question per call (check 08), so the claimed amortization across questions is never measured. qualify the claim or fix the snapshot logic, and benchmark multi-question requests.
Questions for the authors
How were the FLEURS questions in the 1,000-question paired set built, and how do they differ from the 477 FLEURS term-choice questions in Table 1, where accuracy is 1.00 compared with 0.855 in Fig. 3?
What are the Table 1 ECE and 4-way results for the configuration that is actually released (uncalibrated six-level exact-match fraction, binary only)? Will the fitted Platt maps be released?
Were the audio LLMs in Sec. 6.1 prompted in Portuguese for English/Spanish/other audio, as the README suggests? How do they score with length-normalized log-probabilities and prompts in the language of the audio?
What are the paired (marimba minus baseline) bootstrap intervals for each row of Table 4?
How do the 4,000 cross-validation clips and the 5,768 refit clips in Sec. 5.3 relate? Is the 2,000-clip Platt pool disjoint from both and from the 500-clip test?
Can you release the identities of the 500 Smart Turn v3.2 test clips and the 1,728 ICSI windows, and the per-item predictions behind Tables 1–4 for the public benchmarks?
Have you assessed whether Common Voice or FLEURS audio was part of Qwen3-ASR's training data, and how that affects the 'zero-shot' public AUROC?
What is the relationship between charcot.ai and the clinical documentation platform that supplied the private recordings?
Verification
We ran 16 checks: 11 confirmed, 4 discrepancies, 1 inconclusive. We installed the release (pinned weights ad374b4e) and ran it on CPU. It reproduces turn-end AUROC on public Smart Turn v3.2 data (0.953 vs reported 0.930, consistent at z = 1.58) and passes its default test suite (319/0 failed). All released latency numbers recompute to 0.01 ms. The PII, LID, turn-end gap and Table 1 summary statistics are internally consistent. The discrepancies are as follows. (02) The release ships uncalibrated, binary-only lexical scoring rather than the Platt-calibrated system with term choice that was evaluated. (04) The FLEURS term-choice results in Table 1 (1.00, n = 477) and Fig. 3 (0.855, n = 62) are statistically incompatible. (07) The single-encoder-pass claim fails for inputs shorter than 8 s, and the repo's own real-model test fails (check 13). (12) Seven of eight cited evaluation reports and all prediction dumps are unreleased. Results on private data, the PII detector and the audio-LLM comparison could be checked only for internal consistency.
11Confirmed
4Discrepancy
1Inconclusive
✓ConfirmedAbstract; Table 1; Sec. 6 'Term detection'; Sec. 8
✕DiscrepancySec. 1 para 4; Sec. 5.1; Sec. 8; code pretrained.py:decide_encoded (lines 141-160), windows.py:decoder_snapshot; tests/test_pretrained.py:722-736
Minor: the bibliography entry names 'Smart Turn v3', but the paper's baseline and test set are Smart Turn v3.2 (Table 3, Sec. 4). The entry pins no model version, checkpoint or dataset. The test data used is a separate Hugging Face dataset (pipecat-ai/smart-turn-data-v3.2-test). The paper's 500-clip subset of that dataset is not identified.
[1] ICSI Meeting Corpus (groups.inf.ed.ac.uk/ami/icsi/); [2] AMI Meeting Corpus (groups.inf.ed.ac.uk/ami/corpus/)
Minor: both URLs resolve (HTTP 200), but only corpus web pages are cited, not the corpus papers (Janin et al. 2003 for ICSI; Carletta et al. 2005/2007 for AMI).
[8] Convai Innovations. Laya (Hugging Face model card); [20] TypeSafe. Models: Jev (product docs)
Not an error: non-archival web sources used for factual claims about related systems. Both resolve and support what they are cited for. The Laya card lists modernbert-large and mmbert-base variants, RLCD and Apache-2.0. The Jev docs state it 'does not natively accept audio or video (yet)'. The pages may change, so access dates or revisions should be given.
Suggestions
Align the paper with the release: either ship the calibrated lexical maps and the term-choice code, or state explicitly that Table 1 reports an unreleased configuration, and add results for the released one.
Explain the FLEURS question-construction difference between Table 1 and Fig. 3, and report public lexical results in the abstract as a range covering both evaluations.
Fix decoder_snapshot so that padded inputs reuse the shared encoder pass, or qualify the single-pass claim. Benchmark multi-question requests to measure the amortization.
Release evaluation scripts, the 1,000 paired questions, clip/window IDs for Smart Turn and ICSI, and per-item predictions for every public benchmark.
Report paired bootstrap intervals for all baseline comparisons (Table 4, Fig. 3) and replace 'exceeds' with statements those intervals support.
Strengthen the audio-LLM baselines with length-normalized option scoring and prompts in the language of the audio. Report how sensitive the results are to the prompt.
In Sec. 5.1, document the English regex routing, the fixed Portuguese VAD prompt substitution, the layer-9 head features and sigmoid scoring.
Add a data table for the private sets (hours, speakers, clips, positive rate per row) and explain the 4,000/5,768 turn-end pools and the CochlScene sample sizes.
Add a competing-interest statement and describe the relationship between the author's company and the clinical platform that supplied the data.
Fix the normalizer for abugida and unsegmented scripts (Devanagari vowel signs and virama, CJK), or restrict lexical questions to the scripts that have been validated.
Ethics and integrity
Sec. 7 states that the private clinical recordings were used under platform terms of use accepted by clinicians (as LGPD data controllers). It also states that 'the study was not reviewed by a research ethics committee, and patients did not give study-specific research consent.' The paper is transparent about this, but using identifiable-risk medical consultation audio for research without ethics review or patient consent falls short of the standard expected at most venues for health data, even after de-identification. Ethics-board review or a waiver should be obtained and documented. The sole author is affiliated with charcot.ai, which releases the system. The paper has no competing-interest statement and does not state how the company relates to the data-providing platform. We found no evidence of fabricated or manipulated results: every number we could recompute was internally consistent, and the one statistical incompatibility (FLEURS, check 04) is better explained by undocumented differences in question construction than by any integrity problem. No instructions aimed at the reviewer were found in the paper, source or code.
Scope of this review
Private Brazilian Portuguese test sets (all private rows of Table 1), the private PII detector, the 1,000-question audio-LLM benchmark items, and evaluation code and prediction dumps are not released. For these results we checked only internal consistency. We did not rerun Smart Turn v3.2, ECAPA, pyannote 3.1, Qwen3-Omni or Qwen2-Audio, nor the AMI/VoxConverse/ICSI/CochlScene evaluations. The turn-end reproduction used one of ten test shards on CPU with the release weights, which may differ from the evaluated revision. No GPU was available, so L4 latency was recomputed from released timings rather than re-measured.
Most reported numbers cannot be regenerated from released material
major · Abstract links; TeX src comments in Sec. 5–6; hf/README.md
The private pt-BR test sets are not released, which the paper explains. Beyond that, 7 of the 8 evaluation reports cited in the TeX % src: comments (docs/turn_end_readout.md, audio_llm_paired.md, pii_eval.md, language_id_native.md, diarization_results.md, ...) are absent from both the code and Hugging Face repos. Thirteen cited prediction dumps are unreleased. There is no training or evaluation code, and the PII detector is private. hf/README.md still carries '[PENDING]' placeholders (check 12). Tables 1–4, the PII, LID and audio-LLM results can therefore be checked only for internal consistency. Fix: release evaluation scripts, per-item predictions for the public benchmarks, the 1,000 paired questions, and the identities of the 500 Smart Turn and 1,728 ICSI windows.
'Question-conditioned' and 'System One' framing overstates the generality of the release
major · Title; Sec. 5.1; Table 2; src/marimba/questions.py:11-29, pretrained.py:23, 270-286, _head.py
In the release, questions are routed by eight English regex templates (questions.py:11-29). Others are rejected unless task= is given. The 'question-conditioned' head serves only voice activity, and every recognised English VAD question is replaced by one fixed Portuguese prompt ('Há fala humana neste áudio?'), so the head effectively sees a constant input (check 11). It reads layer-9 features, which the paper does not state, and scores a single positive option with a sigmoid rather than a softmax over options. Unseen tasks are at chance (Table 2). The contribution is better described as a typed router over a frozen ASR model plus task-specific linear/MLP probes. Fix: describe the routing and the fixed-prompt substitution in Sec. 5.1, and temper the 'one model' framing.
Baseline comparisons rely on marginal intervals and may disadvantage the audio LLMs
major · Table 4; Sec. 6.1; Fig. 3
The claims that marimba is 'above' ECAPA and 'more accurate than' pyannote 3.1 (Abstract, Table 4) rest on the baseline point estimate lying outside marimba's marginal CI. No paired marimba-minus-baseline intervals are given, and VoxConverse same-speaker does not meet even that test (0.995 lies in [0.994, 0.998], check 06). The AMI same-speaker row has only 32 different-speaker pairs. In Sec. 6.1 the LLMs score options by summed log-probability, which is length-biased, with no prompt tuning. The README indicates Portuguese prompts were used on non-Portuguese audio. Qwen2-Audio answers 'yes' on all 200 turn-end clips, which suggests a format failure rather than a capability limit. Of the three wins that support '6 of 9', only FLEURS binary term detection is a statistically supported zero-shot win (check 05). Fix: add paired CIs for Table 4 and an LLM baseline with length-normalized scoring and prompts in the language of the audio.
Thin description of the private data and the turn-end training pool
minor · Sec. 4; Sec. 5.3; Table 1 (Gold rows); Table 2
Sec. 4 gives no corpus sizes, hours, speaker counts or class balances for the private ID/OOD/Curated/Gold sets. The ID held-out row has n = 71. The reviewed 'Gold' seen subset scores worst (0.801 [0.770, 0.833]), and its CI does not overlap Curated seen (0.896) (check 01); the paper attributes this to ASR misses on drug names but does not quantify it. Sec. 5.3 cross-validates on 4,000 clips and refits on 5,768 without explaining the relation. The CochlScene design of 150 clips per class does not obviously yield n = 492/963. Possible overlap of Common Voice/FLEURS with Qwen3-ASR's training data, which would inflate 'zero-shot' public AUROC, is not discussed.
Some 'at chance' and 'abstention' statements are not supported as stated
minor · Sec. 6 'Unseen tasks'; Table 2; App. A.1
Sec. 6 'Unseen tasks' says all CochlScene 95% intervals include chance. With i.i.d. intervals, 4-way accuracy 0.29 on n = 492 includes 0.25 only if k = 141. AUROC 0.54 on n = 963 with balanced classes gives [0.504, 0.576] (check 14, inconclusive because counts and interval method are not reported). App. A.1 says out-of-distribution input 'should produce an explicit abstention'. On 1 s of digital silence, the released LID still answers 'pt' with p = 0.668 (check 07). Neither point changes the conclusions, but both should be stated precisely.
Small inconsistencies and multilingual normalization gaps
minor · Sec. 6.1; Table 4; src/marimba/lexical.py; References [1], [2], [11]
The paper gives Qwen3-Omni Speech Commands AUROC as 0.991 and the README as 0.992 (check 05). Speaker-change ECE 0.034 clears the preregistered < 0.035 by 0.001 (check 06). The term normalizer claims to keep non-Latin letters, but it splits Devanagari at vowel signs and drops the virama ('हिन्दी' → 'ह नद'). Unsegmented CJK terms cannot match as tokens, and Cyrillic 'й' folds to 'и' (check 02). This matters because LID covers 30 languages. Smart Turn is cited as v3 while v3.2 is used, and the corpora are cited only by web page (references).
LID: FLEURS 300/300 open and closed, Wilson 95% CI [98.74%, 100%]; CV open 84.33% [79.79, 88.01], closed 93.33% [89.93, 95.64]
Wilson intervals [98.74, 100.00], [79.79, 88.01], [89.93, 95.64] reproduce exactly; percentages correspond to integer counts 300, 253, 280 of 300. Intervals treat examples as independent (no speaker clustering).
Recomputed Wilson score intervals for 300/300, 253/300, 280/300 (tol 0.01 pp)
Released code implements the described readouts: turn end = layer-18 logistic pooled over the last 2 s of valid frames + Platt; speaker readouts on layer 12 (4 s halves; last 2 s vs previous 6 s via one-hidden-layer MLP; count from pooled mean+std); LID over 30 languages with softmax over options; VAD via the question-conditioned head
Tail pooling selects exactly the frames centred in the last 2 s that are also valid (mean index 87.00 = expected); speaker intervals 0-4/4-8 s and 0-6/6-8 s and mean+std count features are as described; the change readout is one ReLU hidden layer; 30 languages; closed-set probabilities equal the softmax over options. Undocumented details: the VAD head reads layer-9 features (not stated in the paper); every recognised English VAD question is replaced by the fixed Portuguese prompt 'Há fala humana neste áudio?', so the 'question-conditioned' head in practice receives one constant prompt; questions outside 8 English regex templates are rejected unless task= is given; the head scores a single positive option with sigmoid(score/T), not a softmax over options. The config declares positive_option 'yes', but _head.py:177-178 encodes the Portuguese 'sim' (work/verify/11b_option_text.log), matching the Portuguese prompt.
Imported the released modules and unit-tested pool_layer, task_features, option_probabilities on synthetic frames; inspected config guards, head layer and question routing
The evaluation artifacts behind the reported numbers are available (code and weights linked; TeX src comments cite docs/turn_end_readout.md, audio_llm_paired.md, pii_eval.md, language_id_native.md, diarization_results.md, diarization_preregistration.md, artifacts/diarization/selection.json)
7 of 8 cited evaluation documents are absent from both the code repo and the HF model repo (only docs/benchmarks.md exists); 13 further src comments cite saved predictions (qwen3_asr_0_6b@7f54a303) that are not released. The repo contains no training or evaluation code (the regex match on pretrained.py is a filename false positive), and the only raw measurement data are latency timings. hf/README.md still has '[PENDING] archival citation/DOI and public links for the historical evaluation' and '[PENDING]' VAD training-data attribution. Weights are public and downloadable (verified). So Tables 1-4, the PII, LID and audio-LLM results cannot be recomputed from released material.
Extracted all cited paths from main.tex src comments; tested existence in the released GitHub repo and in the pinned HF model repo file list; grepped release docs for [PENDING]
The released package's test suite passes (default selection, excluding real_model tests)
Default suite: 319 passed, 89 skipped (optional extras), 7 deselected, 0 failed. The repo's real-model test test_real_model_one_tower_pass (tests/test_pretrained.py:722-736) FAILS on the pinned release weights with 'assert [1, 1] == [1]': two audio-tower passes for a 1 s input with mixed questions. This independently confirms the single-pass discrepancy in check 07.
Ran pytest in a fresh /tmp venv (torch 2.8.0 CPU, transformers 4.57.6; optional pipecat/livekit/datasets extras not installed); also ran the repo's own real-model test test_real_model_one_tower_pass with the pinned weights
CochlScene: every head at chance; four-way accuracy 0.24-0.29 (n=492, chance 0.25), binary AUROC 0.48-0.54 (n=963), all 95% intervals include chance
Of the counts that round to 0.29, only k=141 (0.2866) has an i.i.d. Wilson interval containing 0.25 ([0.2484, 0.3281]); k=142-145 exclude it (e.g. 142/492: [0.2503, 0.3302]). AUROC 0.54 with balanced classes gives [0.504, 0.576], which excludes 0.5; with 25% positives it gives [0.498, 0.583]. The statement can hold only with clustered intervals, k=141, or an unbalanced binary set; none of these is reported (exact counts, class balance and interval method for this table are missing). The '150 clips per class' design also does not obviously give n=492 and n=963. The substantive conclusion, that there is no useful transfer, is unaffected.
Wilson intervals for every count k/492 that rounds to 0.24 or 0.29; Hanley-McNeil intervals for AUROC 0.535-0.545 at n=963 with 50% or 25% positives (i.i.d.)
The references exist and support the related-work and data statements they are cited for
All 17 arXiv IDs resolve and their titles match the bibliography. Crossref fuzzy matches are irrelevant because no DOIs are given. All 5 URLs return HTTP 200. Attributions supported: ASOM [5] (frozen speech and text encoders, emotion, MSP-Podcast, one pass without generation); NDM [3] (block attention for option order, open architecture); UniJev [21] (text, image and video); JevAdvBench [10] (adversarial benchmark); TypedBench [17] (calibration and cost in the abstract, framing in the title); Laya [8] (modernbert-large and mmbert-base, RLCD, apache-2.0); Jev docs [20] ('does not natively accept audio or video (yet)'). First authors match arXiv for all named-author preprints. Minor issues are in work/ref_issues.json: Smart Turn is cited as v3 but v3.2 is used, with no pinned version; ICSI and AMI are cited by web page only. No reference is nonexistent or misattributed.
Ran tools/check_refs.py (results in work/refs_checked.json). Fetched arXiv API metadata and abstracts for the 6 load-bearing preprints and the 5 URL-only references, then searched each for the attributes the paper ascribes to it.
Layer-18 turn-end readout reaches AUROC 0.930 [0.906, 0.951] on 500 Smart Turn v3.2 test clips, with ECE 0.041 after Platt calibration
Claimed 0.930 [0.906, 0.951]; obtained 0.953 [0.935, 0.970] (n=500, 255 positives); diff +0.023; two-sample z = +1.58, under the |z| < 1.96 threshold. ECE 0.037 vs claimed 0.041. Caveats: (1) 0.930 lies just outside our own CI. The decision rule was changed after the first run from 'claimed value inside our CI' to a two-sample test, because the subsets differ; this is disclosed. (2) Only 1 of 10 shards was used. (3) The released model revision may differ from the one evaluated in the paper. The released model is at least as good as reported on in-distribution data. Smart Turn v3.2 itself (0.982) was not rerun.
Ran the released model (charcot-ai/marimba@ad374b4e, CPU float32) with Question.score('Has the speaker finished?') on 500 clips sampled with seed 42 from shard 00000 of the public pipecat-ai/smart-turn-data-v3.2-test. Each clip's last 8 s was used; the label is endpoint_bool. Computed Mann-Whitney AUROC, a percentile bootstrap CI (1,000 reps) and 10-bin ECE. Compared to the paper with a two-sample z test, because the paper's 500-clip subset is not identified.
Abstract/Conclusion headline lexical numbers match Table 1: private AUROC 0.80-0.92, public read speech 0.92-0.97, Speech Commands 4-way acc 0.93, binary ECE <= 0.08; held-out >= seen AUROC on every private test; 4-way accuracies are feasible fractions
Private AUROC 0.801-0.915 (claimed 0.80-0.92); CV/FLEURS 0.923-0.970 (claimed 0.92-0.97); max ECE 0.08 (src comment 0.0762); SC acc 0.93; held-out minus seen = +0.009 (ID), +0.015 (OOD), +0.003 (Curated), +0.114 (Gold); all 12 accuracies GRIM-feasible. Noteworthy: Gold seen (reviewed subset) 0.801 [0.770,0.833] does not overlap Curated seen 0.896 [0.881,0.909] or Gold held-out 0.915 [0.865,0.962]; the cleanest-label subset is the worst row and the ID/OOD/Curated held-out vs seen gaps are within CIs.
Transcribed Table 1 from main.tex; recomputed ranges, max ECE, held-out vs seen comparisons, GRIM feasibility of each 4-way accuracy (tol 0.005)
Lexical questions use exact normalized token matching over greedy + 4-beam hypotheses, mapped to probability by a fitted Platt/logistic map; term choice = argmax exact score with fuzzy tie-break; the released package implements this
Exact matching matches the paper for Latin text ('coloca' vs 'colocar' negative; accents/case removed). But the release differs from the evaluated lexical system: term kinds = ('noul',) (no term choice, so Table 1's 4-way column has no released counterpart); pretrained.py:99-100 rejects any manifest whose term calibration is not 'none' and docs/capabilities.md:30-31 says the 'historical decoder study's calibrated lexical scores must not be substituted for this package's uncalibrated raw fractions'; no fuzzy tie-break code exists. The released score takes only 6 values {0,0.2,...,1.0}. Also, 'non-Latin letters kept' is only partly true: Devanagari vowel signs (category Mc) are treated as separators and the virama is stripped ('हिन्दी' -> 'ह नद'); unsegmented CJK text cannot match a term as a token; Cyrillic 'й' folds to 'и'.
Loaded released lexical.py and tested normalize/exact_fraction on paper examples and multi-script terms; AST/text inspection of capability kinds, manifest guard and fuzzy-matching code
Turn-end: readout 0.930 [0.906,0.951] vs Smart Turn v3.2 0.982 [0.973,0.990] (n=500), paired gap -0.052 [-0.075,-0.032]; ICSI 0.716 [0.669,0.756] vs 0.712 [0.649,0.770] (n=1,728), paired gap +0.004 [-0.046,+0.054]; Platt raises ECE 0.034 -> 0.041
Gaps -0.052 and +0.004 reproduce exactly. Implied correlations rho=0.30 (Smart Turn) and 0.58 (ICSI) are valid and plausible, so the paired CIs are coherent with the marginal CIs. Smart Turn gap is ~4.7 paired SEs from zero. ICSI paired CI half-width is 0.05 (27 meeting clusters), so the 'tie' cannot exclude a 0.05 AUROC difference either way, as the paper itself notes. Text and table ECE values agree.
Recomputed gaps from point estimates (tol 0.001); derived SEs from CI widths and the implied correlation between paired bootstrap AUROCs; Hanley-McNeil SE as reference
Table 1 public lexical results (FLEURS binary AUROC 0.970, 4-way 1.00 of 477; CV 0.923, 0.97 of 456) and the paired audio-LLM comparison for the same zero-shot lane (FLEURS binary 0.901 n=138, term choice 0.855 n=62; CV 0.907 n=107, 0.976 n=41) describe the same system on comparable questions
FLEURS term choice: Table 1 reports 1.00 (477 questions, i.e. >= 475 correct) but Fig. 3/README report 0.855 = 53/62 for the same lane; P(X<=53 | n=62, p=0.995) = 3.1e-11, so the two evaluations cannot be samples of the same question distribution. FLEURS binary AUROC 0.970 vs 0.901: z = 1.7-2.7 (p = 0.087-0.008 depending on class balance). CV and Speech Commands rows agree (p > 0.6). Neither the paper nor the README explains how the paired questions differ (e.g. distractor construction or clip length). The abstract's 'public read speech 0.92-0.97' uses only the Table 1 numbers, while the head-to-head reports FLEURS 0.901 and CV 0.907.
AUROC: z-test of difference with Hanley-McNeil SE for the paired-set AUROC (20-80% positives) and the Table-1 CI-derived SE; choice accuracy: exact binomial tail of the paired-set count under the Table-1 accuracy at the favourable end of its rounding interval
Audio-LLM comparison on 1,000 public questions: Marimba beats both LLMs on FLEURS binary term (0.901 vs 0.791/0.682) and turn end (0.935 vs 0.786/0.476); Qwen3-Omni better on Speech Commands (0.991 vs 0.926; 1.000 vs 0.933) and CV LID (1.000 vs 0.904); 'matches or beats Qwen3-Omni on 6 of 9 tests'
Slice sizes sum to 1,000; all 15 accuracies are feasible k/n; figure values match README within rounding; 6 of 9 = 3 wins (CV binary, FLEURS binary, turn end) + 3 exact ties (FLEURS LID 1.000, CV choice 0.976, FLEURS choice 0.855); stated directional claims hold. Minor: paper text gives Qwen3-Omni Speech Commands binary AUROC 0.991, README 0.992. Of the 3 wins, CV binary has a paired CI including zero (Sec. 6.1) and turn end is in-distribution for Marimba only, so the only zero-shot win that is statistically supported is FLEURS binary term detection.
Transcribed README table and figure text (pdftotext); summed n; GRIM integrality of all accuracies; recounted wins/ties; cross-compared paper text, README and figure
Speaker readouts meet the preregistered criterion (<= 0.05 below baseline, calibrated ECE < 0.035); speaker change exceeds ECAPA on both sets and pyannote 3.1; speaker count exceeds pyannote; same speaker on par with ECAPA (AMI: 32 different-speaker pairs)
All six differences are positive (+0.001 to +0.042 vs ECAPA/pyannote), so the -0.05 criterion holds; max ECE 0.034 < 0.035 (speaker change AMI, a 0.001 margin). Five of six baselines lie outside Marimba's marginal CI (VoxConverse same-speaker does not: 0.995 in [0.994,0.998]). The Hanley-McNeil CI for 0.998 with 32 negatives, [0.995, 1.000], is consistent with the reported [0.993, 1.000]. Caveats: no paired Marimba-minus-baseline intervals are reported, so 'exceeds' ignores baseline sampling variability; VoxConverse 3+ recall is at most 0.408 (395/667 predicted as 2).
Arithmetic on Table 4; whether each baseline lies outside Marimba's marginal 95% CI; Hanley-McNeil CI for AMI same-speaker AUROC with 348/32 pairs; bound on 3+ recall from 395/667
A frozen Qwen3-ASR encoder processes each 8-second window once; all questions about a window share one encoder pass. Also: smoke run of the released model on its example clips
On a full 8 s input the four mixed questions (turn end, VAD, language, term) share 1 audio-tower pass, as claimed. On shorter inputs, which the API left-pads, the same questions trigger 2 passes (1 s silence: 2; 4.46 s speech: 2) because the decoder lane re-encodes a left-shifted snapshot (decoder_snapshot). The repo's own real-model test (tests/test_pretrained.py:736, assert calls == [1] for a 1 s input) would therefore fail. Smoke run: 7 of 8 example clips matched their scene labels (turn end 0.975 vs cut-off 0.004; 'marimba' 0.6 vs 0.0 on the near-term clip; es/pt LID p=1.0; speaker change 0.893 with count '2'). The three-speaker clip was counted as '2' (p=0.85), consistent with the undercounting the paper reports. On 1 s of digital silence LID still answers 'pt' with p=0.668, because there is no abstention, although App. A.1 says out-of-distribution input 'should produce an explicit abstention'.
Installed the release (torch 2.8.0 CPU, pinned weights ad374b4e + Qwen3-ASR-0.6B@5eb14417), ran it on CPU float32, counted audio-tower forward calls via a hook for mixed encoder+decoder questions on a 1 s input, an 8 s file, and its 4.46 s unpadded speech; ran the 8 Space example clips with task-appropriate questions
End-to-end L4 bf16 p95 latency per question: 13 ms turn end, 16 ms VAD, 161 ms LID, 2.35 s term (docs: p50 12.23/14.40/153.67/1399.44 ms; p95 13.31/15.77/160.80/2349.14 ms with bootstrap CIs)
All 16 values (p50, p95, CI bounds for 4 paths) reproduce to 0.01 ms; the paper's rounded p95s (13 ms, 16 ms, 161 ms, 2.35 s) match. Caveats: the benchmark used package 0.1.0 and model revision bc980b4e, not the pinned release revision ad374b4e/0.1.2; each call times a single question, so the claimed benefit of sharing one encoder pass across questions is not measured; term latency ranges from 800 to 2,664 ms.
Recomputed p50/p95 (numpy linear) and the documented percentile bootstrap (1,000 resamples, default_rng(42) per path) from the 1,100 released per-call latencies
PII on 200 synthetic pt-BR clips: P 0.966, R 0.850, F1 0.904 (95% CI 0.856-0.945), 3/100 negatives flagged; per-type recall 0.95/1.00/1.00/0.70/0.60; end-to-end F1 0.975 (0.949-0.995) with 1/100 negatives flagged
Per-type TPs 19+20+20+14+12 = 85 give P = 85/88 = 0.9659, R = 0.850, F1 = 0.9043, matching to 3 dp. End-to-end F1 0.975 with 1 FP requires exactly TP = 96 (F1 0.9746). Bootstrap CIs from the reconstructed data, [0.854, 0.945] and [0.951, 0.995], match the reported [0.856, 0.945] and [0.949, 0.995]. Counts are internally consistent. The PII detector itself is private, so the result cannot be reproduced from the release.
Reconstructed integer counts (20 clips per type, FP = flagged negatives); recomputed P/R/F1; solved for end-to-end TP; clip bootstrap (seed 42, 1,000 reps) of reconstructed data