A clean, well-documented architecture whose segmentation tables are internally consistent, but the grounding comparison is not like-for-like and its text overstates Table 2. Two of the headline segmentation leads are within plausible noise, and nothing is released to reproduce the results.
Soundness
2/4
Presentation
3/4
Contribution
3/4
Confidence
3/5
✓ 12 confirmed✕ 3 discrepancy◐ 1 inconclusive
Summary
The paper proposes S4VY, a model that produces class-agnostic, identity-persistent instance masks ("4D masks") over an unordered set of RGB observations of a static or dynamic scene. A VGGT-Ω-1B geometry backbone (LoRA-adapted) feeds a Mask2Former-style Space-Time Query Decoder whose 400 learnable object queries are shared across all frames, so each query binds one entity in every observation without temporal memory or frame ordering. A prompt encoder turns point/box prompts from one or more frames into an extra query, isolated from the learnable queries by a unidirectional attention mask (Eq. 10). The model is trained on a curated corpus of 19 datasets (33,220 scenes, ~6.05M frames) that mixes exhaustive, partial and pseudo-labelled supervision.
For language grounding the paper adds an "agentic harness": Active Tree Search (ATS) chooses which 8-frame windows to inspect, a dual-stream Qwen3-VL-4B Grounder predicts either boxes or a matching object query, and a Qwen3-VL-2B Critic picks between the two candidates.
The paper claims state-of-the-art exhaustive 4D instance segmentation on ScanNet, DAVIS-17, LVOS and VIPSeg (Table 1), as well as on ScanNet200, HOI4D, VISOR and KITTI-STEP (Tables 5–6), with the lowest latency. It also claims robustness to shuffled and sparse observations (Table 7) and the best language grounding on ScanRefer, a ScanNet++ split built by the authors, Ref-DAVIS and MeViS (Table 2).
Strengths
Simple, principled architecture for order-free 4D identity
§3.1–3.2, App. A.1 Eq. (9)–(11), Table 13(b)
Each of the 400 object queries is shared by all observations, so identity persistence comes from the representation itself rather than from memory propagation (App. A.1, Eq. 9–11). The unidirectional mask in Eq. (10) lets prompted and exhaustive segmentation share one decoder without the prompt leaking into the learnable queries. The ablation supports the decision to drop frame-order embeddings: removing positional encodings changes AP by +0.004/+0.006/−0.001, while sinusoidal encodings are consistently worse by 0.022–0.032 (check 13).
Broad segmentation evaluation, and the tables agree with the text
Table 1 (p.8), Tables 5–6 (p.27)
S4VY is evaluated against 9–10 image, video and feed-forward baselines on four main benchmarks and three further ones. It is best in all 11 columns of Table 1, all 9 columns of Table 5 and all 3 of Table 6. Every number quoted in the text matches its table (checks 01, 10). Some margins are large: LVOS J&F leads by +0.158, and on the full 312-scene ScanNet200 S4VY beats IGGT4D by 2.9/4.6/2.8 points. Under any reasonable per-scene variance these gains are not noise (check 15).
Robustness experiment directly tests the central selling point
Table 7 (p.27), App. C.1 l.1432–1442
Table 7 evaluates shuffled and sparse ("hard") observation sets under a protocol defined in App. B.4. The quoted ranges reproduce exactly: video baselines drop 0.6–2.8 J&F (DAVIS) and 1.3–2.0 (LVOS) after shuffling and lose 9.8–16.1 in the hard setting. S4VY's 0.588 is 12.6 points above GLEE (check 04). This is the right experiment for a method that claims to need no temporal ordering.
Candid reporting of unfavourable results
Table 8 (p.28), Table 2, Table 3(c)
The paper states that SAM 2 is stronger with clean box prompts once several observations are prompted (Table 8; check 05 confirms that this holds for every K≥2 and also at K=1 on DAVIS). It also bolds Z3D(GT) where Z3D wins on ScanNet++ [email protected] (Table 2), and Table 3(c) reports ATS's negative ΔQ. Reporting these cases makes the remaining claims more credible.
Detailed and arithmetically consistent data and training documentation
The 19-row corpus table sums exactly to 33,220 scenes and 6,052,440 frames, and every group total matches Fig. 3(c) (check 03). The 79,856 grounding records and the ~5,000-update schedule are also consistent (check 13). Training counts for DAVIS, LVOS, VIPSeg, MeViS and KITTI-STEP equal the official splits, including frame counts, and evaluation counts equal the official splits (check 14). This is good evidence against train/test overlap on these benchmarks.
Weaknesses
Language-grounding comparison is not like-for-like, and the text overstates Table 2
The S4VY Grounder is fully fine-tuned on ≈80k expressions drawn from the training splits of all four evaluation benchmarks (App. A.4). VLM-Grounder, VLM+SAM 2 and Z3D are zero-shot pipelines. On static scenes SAM 3 receives only category prompts (App. B.3 l.1346), which cannot separate same-class instances in ScanRefer. MVGGT scores 0.005/0.003 J&F on Ref-DAVIS/MeViS, which suggests an out-of-scope or broken configuration rather than a meaningful baseline. The ScanNet++ test expressions come from the authors' own Qwen3-VL-32B generation pipeline, so they are in-distribution for S4VY's Grounder only.
The text also misstates the table (check 02, discrepancy). "Z3D approaches our performance only when supplied with benchmark GT point clouds" is contradicted on ScanNet++ [email protected]: Z3D (recon.) scores 31.1 and Z3D (GT) 33.7, both above S4VY's 30.4. The claimed ScanNet++ mIoU gap is 2.8 but the table gives 0.293−0.266 = 2.7. "Despite VLM+SAM 2 using a much larger Qwen3-VL-30B-A3B" overlooks that this is an MoE with ≈3B active parameters, comparable in per-token compute to S4VY's 4B+2B.
Fix: add a zero-shot S4VY Grounder (trained without the target benchmark) or fine-tuned baselines, give SAM 3 full expressions, explain or drop MVGGT on video, add a human-written ScanNet++ test set, and correct the sentences in §5.3.
Segmentation protocol favours S4VY: in-domain training and GT built with its own backbone
major · Table 1, App. A.3 Table 4, App. B.3–B.4
S4VY is trained on the train splits of DAVIS, LVOS, VIPSeg, KITTI-STEP and ScanNet++ (Table 4; disjointness from the val splits is confirmed in check 14). Several feed-forward baselines in Table 1 (PanSt3R, IGGT, SegVGGT, SAM-V) were never trained on video data, and IGGT is a sliding-window re-implementation by the authors (App. B.3). In addition, the 4D ground truth for the video benchmarks is obtained by lifting 2D masks with VGGT-Ω depth and cameras, the same backbone S4VY builds on, and the 4D-IoU/4D-SR metrics are the authors' own (App. B.4, Eq. 16). All methods are lifted through the same geometry, but the paper never tests whether the rankings depend on this choice.
Fix: separate in-domain from zero-shot baselines in Table 1, report S4VY trained without each video benchmark's train split (or retrain the strongest baseline on the same corpus), and report the 4D metrics with an alternative geometry, e.g. sensor depth on ScanNet.
Several headline leads are within plausible noise; no variance reported anywhere
Questions for the authors
What grounding accuracy does S4VY achieve when its Grounder is not trained on the target benchmark's training split (e.g. trained without ScanRefer and evaluated on ScanRefer)? This is the comparison that matches the zero-shot baselines in Table 2.
Can you provide per-clip results for ScanNet (10 clips) and DAVIS (30 videos) in Table 1, with paired bootstrap CIs against IGGT4D and GLEE?
Why does the query-vs-box ordering on ScanRefer reverse between Table 9 (160 queries) and Table 3(b)/13(c) (700 queries)? Do the two use different checkpoints, prompts or decoding?
Which output does the final Table 3(a) row (0.407 mIoU, 46.0 [email protected]) correspond to?
How was step 13,500 of the prompt-encoder run chosen, and on which data?
What stride does the sliding-window baseline in Table 3(c) use, and how do accuracy and window count compare with a non-overlapping stride of 8? What is the ATS depth limit D?
How do the Table 1 rankings change if the 4D ground truth on ScanNet is built from sensor depth and poses instead of VGGT-Ω reconstructions?
How does SAM 3 perform on ScanRefer/ScanNet++ when given the full referring expression rather than the category? Why does MVGGT score near zero on Ref-DAVIS/MeViS?
What is the end-to-end latency of the grounding harness per query (ATS + Grounder + Critic) compared with VLM+SAM 2 and Z3D?
Verification
Only the PDF was available (no code, data or checkpoints), so no model result could be rerun. Sixteen scripted checks tested internal consistency, arithmetic, split hygiene, statistical robustness and references. Twelve were confirmed. Table 1 is best in every column, the corpus and training arithmetic is exact, the robustness and prompt studies reproduce their quoted numbers, and the train/val split sizes match the official splits. Three found discrepancies, all in the text built on the grounding and efficiency tables: the Z3D statement contradicts Table 2's ScanNet++ [email protected] column and gives 2.8 instead of 2.7; Table 9 reverses the stream ordering reported in Tables 3(b)/13(c); and the claim that the efficiency gap widens fails for two baselines. A noise analysis was inconclusive because no per-clip data are reported, but under plausible variances the DAVIS (+0.005) and ScanNet (+0.022, 10 clips) leads in Table 1 are not distinguishable from noise. 123 of 124 references resolved to the cited works.
[61] OpenAI. GPT-5.6 System Card, July 2026 (URL deploymentsafety.openai.com/gpt-5-6)
Not indexed on Crossref or arXiv and could not be verified with the available tools; it is a web-only system card. It is cited only to identify a baseline tool in Table 9 (not load-bearing).
[3] Bai et al., Qwen3-VL technical report, arXiv:2511.21631
The reference exists, but it is cited in §5.3 l.428-429 to describe VLM+SAM 2 as using 'a much larger Qwen3-VL-30B-A3B'. The report's abstract lists 30B-A3B as a mixture-of-experts variant (≈3B activated parameters, per the 'A3B' naming). Per-token compute is therefore comparable to the 4B Grounder plus 2B Critic used by S4VY, so 'much larger' is misleading as a fairness argument. Table 2 also lists 30.5B for VLM-Grounder and Z3D without noting the MoE structure.
Suggestions
Split Table 2 baselines into zero-shot and benchmark-fine-tuned groups, and add a zero-shot S4VY Grounder variant.
Rewrite §5.3 l.426–431: acknowledge that Z3D (both GT and recon.) beats S4VY on ScanNet++ [email protected], correct 2.8 to 2.7, and describe Qwen3-VL-30B-A3B as an MoE with ~3B active parameters.
Report per-clip/per-query results with bootstrap CIs for Tables 1–3, and enlarge the ScanNet evaluation beyond 10 clips (e.g. use the ScanNet200 setup of Table 6 as the main static benchmark).
Mark in Table 1 which baselines were trained on each benchmark's train split, and add a leave-benchmark-out S4VY run for at least one video benchmark.
Report 4D metrics with an independent geometry source on ScanNet (sensor depth and poses) to show that rankings do not depend on VGGT-Ω-lifted GT.
Reconcile Table 9 with Tables 3(b)/13(c), fix the Table 9 caption, and state which stream Table 3(a) reports.
State the sliding-window stride and ATS depth D, and report ATS against a non-overlapping baseline, including the static-scene ΔQ losses in the main text.
Report end-to-end grounding latency and the number of VLM calls per query.
State the checkpoint-selection rule for the prompt encoder, and add the separate-vs-joint training numbers referred to in App. B.1.
Release code, weights, the curated corpus manifest, the pseudo-labels and the ScanNet++ grounding split.
Ethics and integrity
No integrity concerns were found: all checked tables are internally consistent, and the training/evaluation split sizes match the official splits. The ScanNet++ grounding expressions are machine-generated (Qwen3-VL-32B); the paper should state whether any were human-verified. The PDF carries the venue's standard reviewer-policy banner, which is not an instruction aimed at the review and was not acted upon.
Scope of this review
Only the PDF was provided; there is no LaTeX source, code, checkpoints, curated corpus or evaluation outputs. No reported model number could be reproduced, so all checks are internal-consistency, arithmetic, split-size and reference checks. The noise analysis (check 15) uses assumed per-clip standard deviations because per-clip results are not reported. Official DAVIS split sizes come from the reviewer's knowledge rather than a fetched source. The GPT-5.6 system card [61] could not be verified with the available tools. Disjointness of the 80 held-out ScanNet++ grounding scenes from the training scenes could not be checked.
A single forward pass handles 100 observations in 10.1 s, faster than every baseline in Table 1 (next best OMG-Seg at 13.7 s). Table 1 latencies match the LVOS column of Table 11, and all Table 12 hardware-scaling ratios reproduce (check 11).
major · Table 1, §5.3 l.420–424, Table 13(a,b), App. B.4
No table reports seeds, per-clip spread or confidence intervals. The DAVIS 4D-IoU lead is 0.715 vs 0.710 over 30 videos, and the ScanNet T-mIoU lead is 0.803 vs 0.781 on only 10 clips × 8 views. Under assumed per-clip SDs of 0.10–0.20 these margins are 0.3 and 0.7 SE (null p ≈ 0.49–0.89; check 15, inconclusive because per-clip data are not available). The claim "S4VY leads every benchmark" (l.421) therefore rests partly on differences that cannot be separated from noise. Ablations such as Table 13(a,b) also differ by 0.004 AP with single runs.
Fix: report per-clip scores with bootstrap CIs or paired tests, evaluate ScanNet on more than 10 clips, and give seed variance for the ablations.
Nothing is released, and key choices are unspecified
No code, checkpoints, curated corpus or pseudo-labels are available (Reproducibility Statement p.10 promises a future release). The results depend on a ~6M-frame corpus with self-distilled pseudo-masklets (App. B.1), so they cannot currently be reproduced. The grounding pipeline uses the prompt-encoder checkpoint "at step 13,500" of 15,000 without a selection criterion, which raises the possibility of test-set selection (App. B.1 l.1285). The statement that separate vs joint training gives "only marginal differences" comes without numbers. The ATS depth limit D is not given.
Fix: release code and weights, state the checkpoint-selection rule and the data it uses, and add the joint-training table.
Contradictory evidence on which output stream is stronger
On 160 ScanRefer queries, Table 9 has the query stream ahead of the box stream (0.468 vs 0.424 mIoU). On the 700-query ScanRefer set, Table 3(b) and Table 13(c) show the reverse (0.406 vs 0.434), and App. C.3 says "The box stream is stronger on ScanRefer" (check 07, discrepancy). The 0.072 swing is 2.1–3.5 SE under assumed per-query SDs, so subset sampling is an unlikely explanation. Separately, the final Table 3(a) configuration (0.407 mIoU, 46.0 [email protected]) matches none of the Table 13(c) rows (check 06). The Table 9 caption says "Both configurations predict boxes", which does not describe the query stream. These inconsistencies weaken the empirical basis for the dual-stream + Critic design.
Fix: state the protocol and subset for each table, and reconcile them or explain the difference.
ATS savings rest on an undocumented baseline, and static accuracy loss is not mentioned
minor · §5.4 l.472–475, Table 3(c), App. C.2
The "roughly 60% fewer windows" claim reproduces (64.3 % / 66.0 %; check 08). However, the sliding-window baseline's 28.5 windows for ~80 views implies a stride of about 2.6 observations for 8-view windows. With a non-overlapping stride of 8 the baseline would need about 10 windows, comparable to ATS's 9.7. The stride is never stated. The text also mentions only the video-side gains, although on ScanRefer/ScanNet++ ATS lowers query-stream accuracy (ΔQ −1.9/−1.7). ScanRefer presence is given as 27.9 % in Table 3(c) and 28.6 % in App. C.2.
Efficiency text overstated; grounding cost not reported
minor · App. C.2 l.1545–1552, Tables 11–12
"The absolute efficiency gap therefore widens as the number of observations increases" does not hold for DEVA (gap 25.7 s at 71 obs vs 22.2 s at 100 obs; DEVA reports an identical 32.3 s for both) or for SAM 2 (176.4 s vs 164.9 s) (check 11, discrepancy). The GB200 figure of 40.63 frames/s quoted in the text does not appear in Table 12. The latency of the full grounding harness (several VLM calls per window, ATS, Critic in both orders) is not reported, although the paper's efficiency argument would apply to it too.
Unexplained behaviour in the robustness and prompt studies
minor · Table 7, Table 8, App. C.1
S4VY is described as order-free, yet its scores change after shuffling (−0.7 DAVIS / +1.1 LVOS; check 04). Its hard-setting loss (−5.7) is also larger than that of feed-forward baselines (IGGT4D −2.0, SegVGGT −3.3). In Table 8, S4VY's clean box prompts score below its point prompts on ScanNet for K≥2 and do not improve with more prompted views (check 05). The paper discusses none of these observations, although they bear on the claimed multi-frame prompt fusion.
Novelty is mainly systems integration
minor · §1 l.101–107, §2 l.118–144
The components follow known designs: Mask2Former queries and losses (Eq. 4) on a VGGT-family backbone with LoRA, and a VLM grounder with a pairwise VLM critic. The closest feed-forward instance-level works (IGGT4D, SegVGGT, SAM-V, FAST3DIS) appeared months earlier and are cited (§2). The contribution is the unified system and training corpus rather than a new technique. The paper should say this plainly and state more precisely what each component adds over IGGT4D/SAM-V.
Presentation slips
minor · Fig. 3(a), §5.3 l.430, Table 9 caption
The Fig. 3(a) pie (32.7/38.0/29.3 %) is reproduced only when computed by scene count. By frames the unlabelled share is 58.0 %, and the caption does not give the unit (check 03). Table 2 reports the ScanNet++ gap as 2.8 instead of 2.7. The Table 9 caption is inaccurate (see above).
S4VY leads every reported metric on HOI4D, VISOR and KITTI-STEP (Table 5); on full ScanNet200 S4VY 0.517/0.376/0.454 improves over IGGT4D by 2.9, 4.6, 2.8 points (Table 6)
S4VY is best in all 9 Table 5 columns and all 3 Table 6 columns. The ScanNet200 gaps over IGGT4D are exactly 2.9 / 4.6 / 2.8. Coverage is incomplete: IGGT4D is omitted on HOI4D (training overlap, as stated), GLEE is missing on VISOR, and GLEE and PanSt3R are missing on KITTI-STEP.
Transcribed both tables; per-column argmax; recomputed gaps
Efficiency: Table 1 latency equals Table 11 LVOS(100) column; 'the absolute efficiency gap therefore widens as the number of observations increases'; 0.5 s (ScanNet 8 obs) and 10.2 s (HOI4D 100 obs); GB200/A100 ratios 2.44x-3.62x
Table 1 latency equals the Table 11 LVOS column for all 8 methods. The quoted 0.5 s and 10.2 s match. All seven Table 12 ratios reproduce within rounding (e.g. 42.11/11.64 = 3.618 -> 3.62). However, 'the gap widens as the number of observations increases' fails for 2 of 7 baselines. For DEVA the gap is 25.7 s at 71 obs and 22.2 s at 100 obs (DEVA reports an identical 32.3 s for 71 and 100 obs). For SAM 2 it is 176.4 s at 71 obs and 164.9 s at 100 obs, because SAM 2 is slower on DAVIS(71) than on LVOS(100). Minor overstatement; per-clip timing variance is not reported. The GB200 single-clip figure of 40.63 frames/s quoted in the text does not appear in Table 12.
Cross-checked Table 1 against Table 11; computed S4VY's absolute latency gap to each baseline across columns ordered by observation count (8, 41, 71, 100); recomputed the Table 12 ratios
Stream decomposition: box stream stronger on ScanRefer, Ref-DAVIS, MeViS; on ScanNet++ box 0.271 vs query 0.268 mIoU but query better at both thresholds; Critic raises 0.434->0.461, 0.271->0.293, 0.744->0.755, 0.543->0.573 and consistently improves over either stream; J&F = (J+F)/2
All six J&F values equal (J+F)/2 within rounding (e.g. Ref-DAVIS +Critic 0.7555 -> 0.755). All stream-ordering statements hold, all four quoted Critic gains match, and the Critic beats both streams on every metric in all four benchmarks. The +Critic rows match the S4VY row of Table 2. Table 9 contradicts the ScanRefer ordering; see check 07.
Recomputed J&F means (tolerance 0.0006 for rounding), stream orderings, quoted Critic gains and dominance; cross-checked against Table 2
Grounding training data 79,856 records = 30,352 + 31,764 + 16,888 + 435 + 417 ('approximately 80k'); 4 epochs ≈ 5,000 updates at effective batch 64; Table 13(a,b) text statements (LoRA largest gain at AP75; no frame PE preserves quality; sinusoidal consistently degrades)
The sources sum to exactly 79,856. 79,856×4/64 = 4,991 updates, consistent with ≈5,000. LoRA minus full fine-tuning is +0.010/+0.001/+0.027, so the largest gain is at AP75 as stated. Sinusoidal minus learned is -0.022/-0.026/-0.032 (consistently worse). None minus learned is +0.004/+0.006/-0.001, consistent with 'preserves'. All of these differences are single-run values without variance. The segmenter schedule (50k steps × batch 64) amounts to about 96 passes over the 33,220 training scenes.
Arithmetic
Benchmark evaluation splits are disjoint from the training data (DAVIS 60/30, LVOS 120/50, VIPSeg 2,806/343, MeViS 1,662 train vs 47-video eval, KITTI-STEP 12/9)
Training counts equal the official training splits exactly, including frame counts: VIPSeg 2,806 clips / 66,767 frames, KITTI-STEP 12 sequences / 5,027 frames, LVOS 120, MeViS 1,662 and DAVIS 60. Evaluation counts equal the official validation splits (VIPSeg 343, LVOS 50, KITTI-STEP 9, DAVIS 30). This is strong evidence of no train/val overlap for these benchmarks. Caveats: (i) the paper does not name the MeViS evaluation split (47 videos fits valid_u, which has 50); (ii) disjointness of the 80 held-out ScanNet++ grounding scenes from the 907 training scenes is asserted but cannot be checked; (iii) S4VY is trained in-domain on every evaluated video benchmark, while several feed-forward baselines are not.
Compared Table 4 training counts and App. B.4 evaluation counts with official split sizes found by web search (VIPSeg CVPR'22 paper, LVOS repo, deeplab2 KITTI-STEP guide, TRoVE frame counts, MeViS repo); the DAVIS split is from reviewer recollection
Main-table margins (e.g. ScanNet T-mIoU 0.803 vs 0.781 on 10 clips; DAVIS 4D-IoU 0.715 vs 0.710 on 30 videos) support 'leads every benchmark' despite no reported variance
Under every assumed SD, DAVIS 4D-IoU (+0.005, n=30) is within 0.3 SE (null p ≈ 0.79-0.89) and ScanNet T-mIoU (+0.022, n=10) is within 0.7 SE (p ≈ 0.49-0.72). These leads are therefore not distinguishable from noise without per-clip results. LVOS J&F (+0.158, ≥5.6 SE) and ScanNet200 T-mIoU (+0.029 on 312 scenes, ≥2.6 SE) are robust. The result depends on these assumptions because the paper reports no per-clip scores, seeds or CIs.
Analytic SE and Monte-Carlo null simulation (seed 0, 20k draws) under assumed per-clip SDs of 0.10-0.20 and paired correlation 0.5
References exist and match the bibliography (124 entries; load-bearing 2026 preprints VGGT-Ω 2605.15195, SAM-V 2609.25490, IGGT4D 2607.19228, MVGGT 2601.06874, SegVGGT 2603.19926, IGGT 2510.22706, FAST3DIS 2603.25993, Z3D ACL 2026)
123 of 124 references resolve to a work with the cited title. All arXiv IDs given for load-bearing baselines resolve to the cited titles. The 6 Crossref misses (SAM 2, SAM 3, π3, Molmo 2, G2VLM, Uni3R) resolve on arXiv by title. Only the GPT-5.6 system card [61] could not be checked (web-only). The paper's descriptions of SAM-V (VGGT features integrated into SAM for prompted multi-view instance segmentation) and IGGT4D (feed-forward 4D instance-grounded reconstruction) agree with their abstracts. One citation nuance is listed in work/ref_issues.json: the Qwen3-VL report gives 30B-A3B as an MoE, so the paper's 'much larger' overstates its compute.
Ran tools/check_refs.py on all 124 entries (Crossref + arXiv). For the low-overlap matches, ran arXiv title queries and fetched the abstracts of IGGT4D, SAM-V, VGGT-Ω and Qwen3-VL to compare with how the paper characterises them
S4VY leads every benchmark in Table 1 (all 11 segmentation columns on ScanNet/DAVIS/LVOS/VIPSeg) and has the lowest latency; text quotes 0.803 T-mIoU, 0.792 T-SR, 0.803 and 0.602 J&F
S4VY is best in all 11 metric columns and has the lowest latency (10.1 s vs 13.7 s OMG-Seg). The four quoted values match the table exactly. Margins vary widely: DAVIS 4D-IoU 0.715 vs GLEE 0.710 (+0.005); ScanNet T-mIoU 0.803 vs IGGT4D 0.781 (+0.022, on 10 clips). Elsewhere margins are 0.044-0.158. The check covers only internal consistency. The model results cannot be rerun because no code or checkpoints are released.
Transcribed Table 1; per-column argmax and runner-up margin; compared text-quoted values to table
S4VY consistently outperforms VLM-segmenter and end-to-end families on all four grounding benchmarks; 'Z3D approaches our performance only when supplied with benchmark GT point clouds, and still trails our 3D mIoU by 3.0 points on ScanRefer and 2.8 points on ScanNet++'
The family claim holds: S4VY beats VLM-Grounder, VLM+SAM 2, Sa2VA, SAM 3 and MVGGT in all 8 columns. The ScanRefer gap is 0.461-0.431 = 3.0 as claimed. The ScanNet++ gap is 0.293-0.266 = 2.7, not 2.8 (minor). More substantively, on ScanNet++ [email protected] S4VY (30.4) is beaten by Z3D(GT) at 33.7 and also by Z3D(recon.) at 31.1. Z3D(recon.) uses no GT point clouds, so 'approaches our performance only when supplied with GT point clouds' is contradicted for that column. The quoted reconstruction drops 0.431->0.114 and 0.266->0.157 match the table.
Transcribed Table 2; compared S4VY with the best of each family per column; recomputed Z3D gaps; searched for columns where Z3D beats S4VY
Corpus: 19 datasets, 33,220 scenes / 6,052,440 frames ('around 6M frames from 33k scenes'); Fig. 3(c) group totals; Fig. 3(a) pie 32.7/38.0/29.3 %; 3.51M unlabelled frames
Totals are exactly 33,220 / 6,052,440. All four group totals match Fig. 3(c) within rounding (e.g. 3,347 vs 3.35k; 958,588 vs 958.6k). The Fig. 3(a) shares are reproduced only when computed by scene count (32.7/38.0/29.3 %). By frame count they would be 26.1/15.8/58.0 %, and the caption does not state the unit (minor). Fig. 3(b) shares sum to 100.0 %. Unlabelled frames total 3,511,251, matching '3.51M'.
Summed the 19 rows of Table 4 overall and by supervision group; computed pie shares by scene count and by frame count
After shuffling, propagation-based video baselines decline 0.6-2.8 J&F (DAVIS) and 1.3-2.0 (LVOS); on LVOS-hard they lose 9.8-16.1 vs sparse; S4VY 0.807->0.800, 0.645->0.656 and 0.588 hard, 12.6 points above the strongest video baseline
Ranges reproduce exactly: DAVIS 0.6-2.8, LVOS 1.3-2.0, hard 9.8-16.1. The margin of 0.588 over GLEE (0.462) is 12.6. The §5.4 text values match Table 7. S4VY is not exactly order-invariant (-0.7 / +1.1 pts after shuffling), which the paper does not explain. Feed-forward baselines show smaller hard-setting losses (IGGT4D -2.0, SegVGGT -3.3) than S4VY (-5.7), although their absolute scores are lower.
S4VY consistently strongest with clean point prompts; SAM 2 generally stronger with boxes once multiple observations are prompted; at K=8/50% corruption S4VY exceeds SAM 2 by 41.2/25.1 (ScanNet box/point) and 11.9/31.6 (DAVIS)
With clean point prompts, S4VY is best in all 9 rows. With boxes, SAM 2 is better for every K≥2 on both datasets, and also at K=1 on DAVIS (0.809 vs 0.790). The gaps reproduce exactly: 41.2/25.1/11.9/31.6. With clean prompts, S4VY's own box prompts score below its point prompts on ScanNet for K≥2 (0.804/0.800/0.801 vs 0.825), and S4VY's box score does not improve with more prompts. The paper does not discuss either observation.
Grounding ablation: register tokens +17.0 [email protected], multi-view +2.6, CoT +0.8, Critic raises 3D mIoU 0.434 -> 0.461; Table 3(b) consistent with Table 2 and Table 13(c)
The quoted gains reproduce exactly: +17.0, +2.6 and +0.8 [email protected], and 0.434 -> 0.461 for the Critic. Table 3(b) '+Critic' equals the Table 2 ScanRefer row, and Table 3(b) matches Table 13(c). One inconsistency remains: the final Table 3(a) configuration 'Multi + CoT' (0.407 mIoU, 46.0 [email protected]) matches none of the Table 13(c) rows (Query 0.406/45.0, Box 0.434/47.6, +Critic 0.461/50.5). It is therefore unclear which output Table 3(a) reports or under which protocol (minor).
Recomputed differences from Table 3(a,b); cross-checked Table 3(b) against Table 2 and Table 13(c); tested whether the final Table 3(a) configuration equals any output stream
Table 9: Qwen3-VL declines 0.316 -> 0.202 single -> multi-view; Molmo 2 strongest external tool at 0.432; the dual-stream Grounder reaches the best results; consistency with App. C.3 'The box stream is stronger on ScanRefer'
Quoted values match: 0.316 -> 0.202 and Molmo 2 at 0.432. The query stream is best in all three columns. However, on the 160 ScanRefer queries the query stream beats the box stream (0.468 vs 0.424, +0.044). On the 700-query ScanRefer set (Table 13(c) / Table 3(b)) the box stream wins (0.434 vs 0.406, -0.028), and the text says 'The box stream is stronger on ScanRefer'. The swing of 0.072 is 2.1-3.5 SE under assumed per-query difference SDs of 0.3-0.5, so subset sampling is an unlikely but not impossible explanation. Table 9's caption also says 'Both configurations predict boxes', which does not fit the query stream.
Transcribed Table 9; per-column best; compared Query-minus-Box mIoU on the 160-query subset with the 700-query set of Table 13(c); computed how many standard errors the swing is under assumed per-query SDs
Active Tree Search uses 'roughly 60% fewer windows' on ScanRefer/ScanNet++; on video benchmarks fewer windows with query-stream accuracy preserved or improved
Reductions are 64.3 % (ScanNet++) and 66.0 % (ScanRefer), consistent with 'roughly 60%'. On the video benchmarks ATS uses fewer windows (11.4 < 15.5, 15.8 < 17.6) with ΔQ of +0.7 and +3.7. The text omits that on the static benchmarks ATS lowers query-stream accuracy (ΔQ -1.9 / -1.7). The sliding baseline implies a stride of about 2.6 observations for 8-view windows (a stride of 8 would give 10.0 windows, comparable to ATS's 9.7). The stride is never stated, so the size of the saving depends on an undocumented baseline. ScanRefer presence is 27.9 % in Table 3(c) but 28.6 % in the App. C.2 text.
Recomputed window reductions and the signs of ΔQ/ΔB; inferred the sliding-window stride from the mean view count (80.3, App. C.2) and Nw = 8
Table 10 frame localisation: Ours P 0.708, R 0.535, F1 0.573, IoU 0.455, selected 21.6 % with presence 28.6 %; highest F1 and IoU
For Ours, the implied selection is 0.535×0.286/0.708 = 21.6 %, matching the reported 21.6 %. Other rows agree within 0.1-0.6 pt, except LensWalk (15.1 % implied vs 12.6 %), which is acceptable for per-scene averages. All rows satisfy the IoU/F1 bounds. In the Select-all row P = IoU = 0.286 = presence and R = 1. Ours has the highest F1 and IoU. The table is internally coherent.
Tested the identity selected ≈ recall×presence/precision for each row; tested the Jensen bounds g(mean F1) ≤ mean IoU ≤ mean F1 with g(f) = f/(2-f); checked the Select-all row