Elegant, correct closed-form corrective drift that we reproduced on the GMM benchmark, but none of the main experiments isolates its benefit: in our rerun a Langevin-only guidance baseline (absent from Tables 1–3) matches IPG on the 256-D GMM, and the image/protein evidence rests on diversity and best-of-N metrics that do not measure posterior calibration.
Soundness
2/4
Presentation
3/4
Contribution
3/4
Confidence
4/5
✓ 15 confirmed✕ 1 discrepancy◐ 1 inconclusive○ 1 not checkable
Summary
The paper targets inference-time steering of pretrained flow and diffusion models, i.e. sampling p1∝q1exp(R). Starting from the Feynman–Kac PDE of the tilted path (Eq. 3), it adds a transport term ut whose Stein-operator contribution Spu cancels the reweighting term g−Epg (Eqs. 8–11). Choosing ut in an RKHS and adding Tikhonov regularisation gives a closed-form drift from an N×N linear solve (Eq. 13), after which the residual log-weight increment is exactly −λφi (Eq. 14). For small λ the weights are dropped, giving an unweighted interacting-particle sampler (IPG); a control-variate variant (IPG-CV, Eqs. 15–16) treats Epg as a free parameter.
Experiments compare IPG/IPG-CV with FKC (SMC) and DriftLite on a 256-D Gaussian mixture with an exact posterior (Table 1), AFHQ-Cat inpainting with N=16 (Table 2) and Proteina-based protein structure inference from sparse distances (Table 3). The paper reports large gains on the GMM, much higher sample diversity than the collapsing SMC baselines on images and proteins, better best-of-N scores, and wall-clock overhead below 1% relative to FKC.
Strengths
Correct, compact derivation with an elegant weight identity
Sec. 2.2–3.1, Eqs. (3), (13)–(16); App. A–C
Every derivation we tested holds to machine precision: the Feynman–Kac PDE (Eq. 3; check 05, rel. error 1.7×10−25), the closed-form minimisers (13), (15), (32) (check 02, ≤3×10), the Stein-kernel Gram matrix (33) (check 04), the identity that the residual weight increment equals (Eq. 14/16; check 03, ), the diffusion-reweighting reduction (App. C; check 13) and the gradient-field Euler–Lagrange equation (Eq. 19; check 15). The identity in Eq. 14 makes a clear knob between pure transport and SMC.
Weaknesses
The main experiments do not isolate the corrective drift
major · Tables 1–3; Sec. 5; App. E l.853–855
The method's contribution is the drift ut, but Tables 1–3 compare only against SMC baselines. App. E (l.853–855) admits that on the 256-D GMM a Langevin-only guidance with no drift 'performs nearly as well as IPG'. Our rerun makes this sharper: the heuristic gives 0.847/0.0110/0.0931 vs IPG 0.863/0.0112/0.0935, i.e. identical within noise (check 01), because the exact posterior sits on a single component in every instance (max weight 1.000000 in 20/20 instances; check 10). On images and proteins, the diversity gap with FKC/DriftLite may come simply from not resampling with N=16. The drift's value is shown only on the 2-D toy (Table 6, reproduced in check 17), where FKC with resampling is as good or better. Fix: add the Langevin-only heuristic (and standard DPS/FlowDPS-style guidance) to Tables 1–3, and use a high-dimensional benchmark with a genuinely multimodal posterior.
Best-of-N claim overstated and not a posterior-quality measure
Questions for the authors
How does Langevin-only guidance (no drift, no weights) perform on the image and protein tasks? If it matches IPG there as it does on the 256-D GMM, what is the practical benefit of the drift?
Can you report a high-dimensional experiment with a genuinely multimodal posterior (e.g. the 256-D GMM with weaker observations or fewer observed dimensions) where the drift's contribution is visible?
How do the errors of IPG behave as N grows and λ→0 on the GMM? Does the gap to the exact-sample floor shrink?
Why does IPG (122.1°) show a significant orientation bias in the protein task while IPG-CV (126.9°) does not?
Is the FKC/None row in Table 4 a copy of Table 1, or were the numbers regenerated under noisy SVGD dynamics?
Do FKC/DriftLite with adaptive (ESS-triggered) resampling still collapse at N= on images and proteins?
Verification
We ran 18 checks: 15 confirmed, 1 discrepancy, 1 inconclusive, 1 not checkable. All core derivations (Eqs. 3, 13–16, 19, 33, App. C, OU setup) were verified numerically or symbolically to machine precision. An independent numpy reimplementation reproduced Table 1 and the 2-D Table 6 qualitatively and largely quantitatively, but also showed that a Langevin-only baseline matches IPG on the 256-D GMM, whose posterior is unimodal in every instance. The best-of-N claim in Sec. 5.2 is not uniform across Table 2 and best-of-N is not a proper score. IPG's Rot. div. is 5.1 sd below the uniform null. Image and protein results could not be rerun (no code); test-protein metadata were confirmed against the PDB.
15Confirmed
1Discrepancy
1Inconclusive
1Not checkable
✓ConfirmedTable 1, Section 5.1, Appendix D (Eqs 37-40), Appendix E l.853-855
Kalaivanan, Zhao, Sjölund, Lindsten. ESS-Flow: Training-free guidance of flow-based models as inference in source space. arXiv:2510.05849, 2025.
Minor bibliographic mismatch: arXiv:2510.05849 currently resolves to 'ESS-Flow: Training-free guidance as Bayesian inference in source space' (same authors and work, title differs from the one cited).
Millard, Lindsten, Zhao. Particle-guided diffusion models for partial differential equations. ICML 2026 (cited as 'Appendix A.6').
Cited (Sec. 1, l.045-046) for SMC reweighting/resampling being interpreted as 'local best-of-N search'. Appendix A.6 of arXiv:2601.23262 is titled 'Tempered ESS and Genetic Algorithms' and frames collapsing-ESS SMC as an evolutionary algorithm (selection ~ resampling). This broadly supports the point, but it is a paraphrase rather than the 'best-of-N' framing the citation implies.
Suggestions
Add a Langevin-only (no drift, unweighted) baseline and at least one standard guidance method (DPS/FlowDPS/ΠGDM) to Tables 1–3.
Replace or complement the 256-D GMM with a high-dimensional benchmark whose posterior is multimodal, so the drift's effect on mode weights can be measured.
Report calibration-sensitive metrics (coverage, energy score/CRPS, or comparison with a long-run reference sampler) alongside best-of-N, and qualify the claim at l.373–374.
Give standard errors or bootstrap intervals for Tables 2–3 and include adaptive-resampling baselines.
Add an error-vs-N and error-vs-λ study, and discuss (or bound) the bias introduced by dropping the −λφ weights.
Clarify which MMD quantity is tabulated and the exact RBF parameterisation in Eq. (39).
Check the FKC/None row of Table 4 and release code to make Tables 2–3 reproducible.
Scope of this review
Only the PDF was available: no LaTeX source, code, model checkpoints or generated samples. The image-inpainting (Table 2) and protein (Table 3) results could not be rerun; for these we checked only internal arithmetic, the statistical reference for Rot. div., runtime ratios and PDB metadata. The GMM experiments were reproduced with our own implementation written from the paper's description, so small numerical differences may reflect unstated implementation choices. No instructions aimed at reviewers were found in the paper.
The GMM headline numbers reproduce from the text alone
Sec. 5.1, Table 1; App. D
An independent reimplementation from App. D gives IPG mean error/MMD/SWD 0.863/0.0112/0.0935 vs the reported 0.841/0.012/0.093, and FKC (every step) 3.07/0.147/0.229 vs 3.685/0.148/0.260, with the same ordering of all methods (check 01). App. D is detailed enough to make this possible.
Negligible computational overhead
Sec. 5.2 l.375–377; Sec. 5.3 l.466–467; Algorithm 1
The extra cost is one Gram matrix and an N×N solve using quantities already computed. Reported overheads are 0.66% (images) and 0.24% (proteins) vs FKC, while DriftLite is 3.6× slower (check 09); our CPU timing of the extra linear algebra at the paper's sizes is consistent with this being small.
Clear diversity gains over resampling-based SMC at small N
Sec. 5.3, Table 3; Sec. 5.2, Table 2
With N=16, FKC and DriftLite collapse (Rot. div. 0.6°/0.7°, near-zero covariance trace), while IPG/IPG-CV keep diverse samples; IPG-CV's Rot. div. of 126.9° is statistically consistent with uniform orientations (z = +0.49 under a Monte Carlo null; check 07). Using rotational invariance as a built-in diversity test with an analytic reference is a nice design.
Honest positioning and candid negative results
Sec. 3.1, Sec. 4.2; App. D.2, E, G
The paper credits Stein transport, NETS (Eq. 17 equivalence), DriftLite and kernel Fisher–Rao flows, and itself reports that FKC wins on the 2-D GMM (Table 6), that neural drifts beat IPG on mean error (Table 5), and that heuristic guidance is near IPG on the 256-D GMM (App. E l.853–855). The test proteins were carefully chosen after the Proteina release (all 15 Table 7 entries verified in the PDB; check 16).
major · Sec. 5.2 l.369–374, Table 2; Table 3
Sec. 5.2 (l.373–374) states that best-of-N metrics 'show that IPG and IPG-CV produce samples that fit the ground truth better'. This is not uniform in Table 2: Box-mask Best SSIM is 0.6708 (IPG) and 0.6711 (IPG-CV) vs 0.6739 (FKC) and 0.6750 (DriftLite); IPG variants win 10 of 12 best-of-N cells and none of the 6 average-metric cells (check 08, discrepancy). More fundamentally, best-of-N rewards spread rather than calibration: in a Gaussian toy an under-dispersed sampler beats the exact posterior at d≥16 and an over-dispersed one wins at d=1 (check 08). The same caveat applies to 'Any designable' in Table 3. Fix: qualify the claim and add calibration-sensitive measures (e.g. coverage of the ground truth within sample quantiles, energy score / CRPS, or comparisons to a reference sampler on a smaller problem).
No consistency analysis; near-uniform weights hold by construction
major · Sec. 3.1, Eq. (14); Sec. 5.1 l.311–313
Eq. 14 holds only at the particles (in-sample): an N-dimensional RKHS fit can always drive the in-sample residual to −λφ, so ESS/N ≈ 1 (Table 1) is not evidence that particles track pt (check 03; the paper concedes this at l.312–313). Once weights are dropped, IPG is a biased interacting system and nothing is said about its limit as N→∞, Δt→0, λ→0. Empirically IPG stays well above the finite-N exact-sample floor on the GMM (MMD 0.0112 vs 0.0012; check 01). A mean-field or bias analysis, or at least an empirical study of error vs N and λ, is needed to support the framing as a principled alternative to SMC.
Image and protein results cannot be checked and lack uncertainty
major · Sec. 5.2–5.3, Tables 2–3; Reproducibility statement l.502–503
Tables 2–3 report single numbers over 50 images / 15 proteins with no standard errors or per-instance spread, and no code, samples or per-instance results are released (l.502–503), so none of these numbers could be verified (check 18). Baselines resample at every step with N=16 here, whereas adaptive resampling was used on the GMM; an adaptive-resampling FKC would be the fairer baseline. Fix: report standard errors or bootstrap intervals, include adaptive resampling, and release code.
IPG orientations are measurably non-uniform
minor · Sec. 5.3 l.422–431, Table 3
Sec. 5.3 describes Rot. div. as close to 126.5° for both variants. Under perfectly uniform orientations, the reported statistic (16 particles, 15 proteins) has mean 126.47° and sd 0.86°; IPG's 122.1° is 5.1 sd below (tail probability <5×10−5), while IPG-CV's 126.9° is consistent (check 07). The text should say IPG retains a measurable orientation bias, which also points to a difference between IPG and IPG-CV worth explaining.
MMD reported is not the quantity described
minor · App. D, Eq. (39), Table 1
App. D describes the unbiased MMD² estimator, but our reproduction matches the Table 1 values only when taking the square root of the unbiased MMD² (check 01). Please state precisely which quantity is tabulated and the kernel parameterisation (Eq. 39 gives σk2=median2/logN but not whether the kernel is exp(−r2/2σ2) or exp(−r2/σ2)).
Possibly duplicated row between Tables 1 and 4
minor · Table 1 (p.6) vs Table 4 (App. D.1)
The FKC/None row of Table 4 (noisy SVGD dynamics) is identical in all 8 numbers to Table 1 (Langevin dynamics), whereas the DriftLite/None row and every other non-trivial cell change (check 12, inconclusive). This looks like a copy error; please confirm or correct.
Hyperparameters vary across tasks without sensitivity study
minor · App. D, F, G
λ is 10−3, 10−1 and 10−2 in the GMM, image and protein tasks, and σt changes schedule too (App. D, F, G). Since λ trades conditioning against the size of the discarded weights (Eq. 14), a sweep reporting ESS and sample quality vs λ and the cost scaling O(N3+N2d) beyond N=16/256 would make the method easier to apply.
Weak prior limits what the protein task shows
minor · Sec. 5.3, Table 3
Average RMSDgt is 7.5–8.1 Å for every method (Table 3), so the protein conclusions rest mostly on diversity and best-of-N, see the weakness above.
16
The 256-D GMM exact posterior is concentrated on one mixture component, so Table 1 does not test multimodality
max component weight is 1.000000 in all 20 instances (second-largest about 1e-33 to 1e-44); effective number of components 1.0000. The Table 1 posterior is a single Gaussian, so the main high-dimensional benchmark cannot show whether IPG handles posterior multimodality
Generated 20 instances following the Appendix D recipe and computed exact posterior component weights by Gaussian conjugacy
Without resampling FKC and DriftLite have one to three effective particles out of 256 (ESS/N 0.006±0.002 and 0.011±0.004)
FKC 1.54 (1.02-2.05 within ±1 sd), DriftLite 2.82 (1.79-3.84); means fall in the stated 1-3 range
Arithmetic ESS = (ESS/N) x 256
Table 4 (noisy SVGD in place of Langevin) reports results from different dynamics than Table 1, yet the FKC None row is identical
FKC/None row is identical in all 8 numbers (0.006±0.002, 7.593±1.337, 0.876±0.165, 0.682±0.112), whereas DriftLite/None changes (5.691±1.194 -> 5.973±1.857) and every other non-trivial cell changes. Exact agreement across two different stochastic dynamics is very unlikely, which suggests a copy error, but the paper alone cannot show this; authors should confirm
Transcribed both tables and compared all mean±sd cells row by row
div div(D p) = p A_p D with A_p D as in Eq (34), and div div(D p) = -div(u p) for u = -D grad log p - div D, so diffusion-reweighting reduces to drift-reweighting
both residuals simplify exactly to 0; the variant without the factor 2 leaves a nonzero residual
sympy in 2-D with symbolic symmetric D(x) and symbolic log-density; simplified both differences; power check removing the factor 2
OU setup a=3, b=sqrt(6): probability-flow drift v_t = a x + (b^2/2) grad log q_t (Eq 38) transports the OU marginals q_t; stationary variance 1 matches the GMM total variance; q_0 close to N(0,I)
max relative continuity residual 1.1e-12 (tolerance 1e-10; sign-flipped drift gives residual 1.67); b^2/(2a) = 1.0; at t=0 means shrink by exp(-3)=0.0498 and component variance is 0.9987, so q_0 is close to but not exactly N(0,I)
sympy: exact 1-D two-component Gaussian-mixture OU marginal, continuity residual dq/dt + d(vq)/dx at 15 random (x,t); sign-flipped power check; closed-form shrink and variance at s=1
The gradient-field objective (19) has minimisers satisfying the corrective-drift PDE (11) with u = grad psi
(a) EL + p(S_p grad psi + g - c) simplifies to 0 exactly; (b) max residual 6.3e-3 in the bulk of p against max|g - Eg| = 8.9 (0.07%, within discretisation error)
(a) sympy Euler-Lagrange equation of the 2-D integrand vs -p(S_p grad psi + g - c); (b) 1-D finite-difference minimisation of (19) for a bimodal p and then the residual of Eq (11)
Table 7 test proteins were deposited after the Proteina weights release, have 100-250 residues and resolution <= 2.5 A, are X-ray except 9ZKD (EM), with the listed modeled/deposited counts and resolutions
all 15 IDs exist as single-protein-entity entries; resolution, deposited length and modeled count match Table 7 exactly for every entry; all are X-ray except 9ZKD (electron microscopy); deposit dates 2025-08-25 to 2026-09-01, after the early-2025 public Proteina release
Queried the RCSB PDB Data API for all 15 entries (deposit date, method, resolution, entity length, modeled count) and compared with Table 7
Table 6 (2-D multimodal GMM): Langevin-only heuristic guidance is much worse (mean error 1.635, MMD 0.207, SWD 1.462) than IPG (0.269, 0.029, 0.433) and FKC every step (0.212, 0.041, 0.401)
heuristic 1.555±0.191 / 0.198 / 1.431 (paper 1.635/0.207/1.462), putting 23.7% of particles near the (3,3) component vs exact weight 6.2%; FKC every step 0.270 / 0.050 / 0.476 (paper 0.212/0.041/0.401); IPG ESS/N 0.986, 0.406±0.240 / 0.045 / 0.523 (paper 0.968, 0.269/0.029/0.433), 9.8% near (3,3). The corrective drift clearly matters here, and IPG does not beat FKC with resampling on mean error or SWD (our IPG is somewhat worse than the paper reports, within its large seed-to-seed sd)
Same independent implementation as check 01 specialised to the Appendix E 2-D setup; 20 seeds; heuristic, FKC every-step and IPG
Image-inpainting and protein results (Table 2 PSNR/SSIM/LPIPS/diversity; Table 3 RMSD, Rot. div., designability), including the effect of the missing Langevin-only guidance baseline in these tasks
Rerunning would need the authors code plus the 1-rectified-flow AFHQ-Cat and Proteina 60M checkpoints, the 50 test images and masks, and GPU time. Only internal arithmetic (check 08) and test-set metadata (check 16) could be checked
None possible: no code, generated samples or per-image/per-protein results are released (Reproducibility statement l.502-503)
Table 1: on the 256-D GMM, IPG reaches mean error 0.841±0.051, MMD 0.012±0.002, SWD 0.093±0.002 with ESS/N 1.000, far better than FKC (every step 3.685/0.148/0.260; adaptive 4.485/0.184/0.311; none 7.593/0.876/0.682); App. E says Langevin-only heuristic guidance performs nearly as well as IPG
Reproduced (mean±sd, 5 instances): IPG ESS/N 1.000, mean error 0.863±0.031, MMD 0.0112±0.0013, SWD 0.0935±0.0014 (paper 0.841/0.012/0.093); IPG-CV 0.858/0.0126/0.0939 (paper 0.842/0.013/0.093); FKC every step 3.069/0.147/0.229 (paper 3.685/0.148/0.260); FKC adaptive 4.427/0.215/0.317 (paper 4.485/0.184/0.311); FKC none ESS/N 0.004, 8.486/0.964/0.750 (paper 0.006, 7.593/0.876/0.682). Tolerance 25% on IPG plus same ordering: met. Caveats: (1) the Langevin-only heuristic, absent from Table 1, gives 0.847/0.0110/0.0931, the same as IPG within noise, so Table 1 does not isolate any benefit of the corrective drift; (2) the paper numbers match sqrt(unbiased MMD^2), while App. D says MMD^2 is reported; (3) the finite-N exact-sample floor is mean error 0.532, MMD 0.0012, SWD 0.0831, so IPG remains clearly above it (MMD about 9x the floor)
Independent numpy reimplementation from the paper text (exact OU-GMM scores, Eq 38 drift, Eq 33 Gram, solves (13)/(15), Algorithm 1, 500 steps, N=256, sigma_t=3, lambda=1e-3, median-heuristic RBF), FKC with none/adaptive/every-step systematic resampling, plus a Langevin-only heuristic baseline and an exact-posterior-sample floor; 5 random instances as in the paper
Closed forms (13) [IPG], (15) [IPG-CV] and (32) [weighted particles] are the unique minimizers of the empirical objective (12)/(25)/(26) over H_k^d
max |u_ridge - u_closed| between 1.4e-15 and 2.9e-15 for all five variants (drift scale 0.52, tolerance 1e-8); dropping the grad-k term gives an error of 0.19, so the test can detect a wrong formula
Used a kernel with an explicit finite feature map (40 random Fourier features), so the RKHS problem becomes a ridge regression solved directly with numpy; compared the ridge solution with the closed forms built from the Eq (33) Gram matrix at test points (d=3, N=8, non-Gaussian target, lambda=0.05, uniform and random weights; IPG-CV also as a joint minimisation over (u, mu))
Under the closed-form drift the log-weight increment reduces exactly to -lambdaphi_i (Eq 14), and to -lambdaphi_i for IPG-CV after subtracting the optimal mu_t (Eq 16)
max |increment + lambdaphi| <= 4.8e-11 for both IPG and IPG-CV at every lambda (relative 2.4e-11, tolerance 1e-6); residual lambda|phi| scales linearly from 0.2 (lambda=0.1) to 2.4e-4 (lambda=1e-4) relative to max|g|=2.0. The identity holds only at the particles (in-sample), so near-uniform weights are by construction and do not by themselves show the particles follow p_t
Computed S_p u(X_i) by central finite differences of the closed-form RBF drift (no use of the Gram identity), added the centred g, and compared with -lambda*phi for lambda = 1e-1 ... 1e-4 (d=4, N=12, non-Gaussian target)
Stein-kernel Gram entries [xi]_ij (Eq 33) equal S^Xi S^Xj k(Xi,Xj) for the basis functions of Eq (13)
max relative difference Eq (33) vs finite differences 3.5e-20 (tolerance 1e-8); sign-flipped variant differs by up to 9.9 (relative), so the test can tell a wrong formula apart; Gram matrix symmetric
Applied the Stein operator to the Eq (13) basis field by 30-digit central finite differences (mpmath) for an RBF kernel and a non-Gaussian 3-D target, 20 random point pairs; power check with a sign-flipped term
The tilted path p_t ∝ q_t exp(r) satisfies the Feynman-Kac PDE d_t p = -div(v p) + p (g - E_p g), g = d_t r + <v, grad r>
max relative difference LHS vs RHS 1.7e-25 (tolerance 1e-8); omitting the -E_p[g] term gives relative error 1.62
1-D exact OU-mixture prior with v_t from Eq (38), non-Gaussian reward, r = tR; p_t with Z_t by 25-digit mpmath quadrature; both sides of Eq (3) evaluated at 6 random (x,t) using numerical differentiation
2-D GMM posterior component weights are 0.572, 0.366 and 0.062
Closed-form Gaussian conjugacy: w_k ∝ N(y; A mu_k, A Sigma A^T + sigma_obs^2)
Expected angle between two independent uniform orientations is 126.5 deg; IPG (122.1) and IPG-CV (126.9) are close to this value
reference value 126.476 deg (claimed 126.5, tolerance 0.05). Under the uniform null the reported statistic has mean 126.47, sd 0.86, 95% range [124.71, 128.07]. IPG-CV 126.9 is consistent (z=+0.49), but IPG 122.1 is 5.1 sd below (MC tail prob < 5e-5). So IPG orientations are measurably not uniform, and calling 122.1 close to 126.5 needs qualifying
Analytic Haar mean pi/2 + 2/pi plus quadrature; Monte Carlo (20,000 replicates) of the reported statistic under perfectly uniform orientations: 16 Haar rotations per protein, mean over 120 pairs, averaged over 15 proteins
Best-of-N metrics show that IPG and IPG-CV produce samples that fit the ground truth better, while baselines only marginally win on averages
IPG variants win 10 of 12 Best-of-N cells, but not Box-mask Best SSIM: IPG 0.6708 and IPG-CV 0.6711 vs DriftLite 0.6750 and FKC 0.6739. On averages the baselines win all 6 mask x metric cells (e.g. Half Avg PSNR 15.99 vs 15.74). Toy: best-of-16 separates an exact sampler from a collapsed one (d=16: 1.065 vs 2.000), but it is not a proper score: an under-dispersed sampler (scale 0.5) beats the exact posterior for d>=16 (d=256: 1.135 vs 1.738), and an over-dispersed one wins at d=1 (0.047 vs 0.071). So best-of-N shows the samples are diverse, not that they are calibrated posterior samples
Tabulated all mask x metric Best-of-N cells of Table 2 against the better baseline; toy Gaussian simulation of best-of-16 squared error for exact, collapsed, over- and under-dispersed samplers in d_eff = 1..256
IPG has negligible overhead vs FKC (122.9 s vs 122.1 s per image; 126.0 s vs 125.7 s per protein) while DriftLite is much slower (444.3 s; 460.6 s)
overhead 0.66% (image) and 0.24% (protein); DriftLite/FKC = 3.64x and 3.66x. Extra IPG linear algebra costs 62 ms/step on CPU for N=16, d=196,608 (12.4 s per 200-step run; a GPU would be far faster, consistent with the reported 0.8 s), 0.46 ms/step for the protein size, 7.4 ms/step for the GMM (N=256). Wall-clock numbers themselves cannot be reproduced without code and hardware
Recomputed relative overheads; timed a numpy implementation of the extra IPG work (Eq 33 Gram, N x N solve, drift) at the paper sizes on 2 CPU cores