A valuable and well-engineered 3D-stitching montage cryo-ET workflow with an impressive dataset, but several quantitative biological claims do not hold as stated: the barbed/pointed-end profile is produced by the polarity rule itself, the ~1 mM concentration depends on an unreported hull volume that implies a network half as thick as stated, and the branch-density figures cannot be reproduced. All of this rests on two cells, with code and most data withheld.
Soundness
2/4
Presentation
2/4
Contribution
3/4
Confidence
3/5
✓ 7 confirmed✕ 8 discrepancy◐ 2 inconclusive
Summary
The paper presents a montage cryo-ET workflow for very large fields of view. Tilt series are acquired as overlapping tiles (PACE-tomo, square-cropped K3, 10-15 % overlap). Each tile is reconstructed and denoised on its own (AreTomo3 plus cryo-CARE, or a WarpTools/IsoNet2 branch), and the tomograms are then stitched in 3D with the connectomics optical-flow tool SOFIMA. Applied to membrane-extracted, glutaraldehyde-fixed and phalloidin-stabilised zebrafish keratocytes and keratocyte fragments, it yields five montages of 23-80 tiles covering ~37-127 µm² at a 1.35 nm voxel size. A 3.6 Å in situ-derived F-actin map supports the claim that the preparation preserves structure.
From Amira filament traces in four montages from two cells, the authors report an F-actin concentration of ~0.9-1.0 mM and a length distribution dominated by short filaments (>90 % <0.5 µm) that also contains filaments up to ~4.8 µm long. They find no vertical two-layer segregation, barbed-end enrichment within ~300 nm of the edge, and lateral heterogeneity in density and orientation, which they relate to local edge curvature. On one montage, template matching finds 6,954 Arp2/3 branch junctions (~92 % precision), reported as ~189/µm² and one per 0.92 µm of filament. Junction geometry links filaments into multi-generation trees alongside long unbranched filaments. One montage is shared through webKnossos.
Strengths
Modular 3D stitching of independently reconstructed tiles
Fig. 1; Results p7-8; Methods p27-28
Each tile is reconstructed and denoised before SOFIMA optical-flow stitching in 3D. This sidesteps the per-tilt 2D projection stitching used by e.g. Peck et al. 2022, and any per-tile tool (cryo-CARE, IsoNet2) can be dropped in. The Methods give concrete parameters (CLAHE clip 0.02, coarse 50-voxel patches, fine mesh stride 20 voxels, search radii), so the pipeline is in principle reimplementable.
Large, high-resolution volumes with coherent bookkeeping
Fig. 1D; Table S2; Table S3
The five montages (23-80 tiles) cover 37.4-~127 µm² at 1.35 nm voxels, large for cellular cryo-ET. Every reported area lies within the geometric bounds set by its tile count, FOV and overlap, and throughput (3.38-3.39 min/tile) is consistent across datasets (check 08). Table S3 counts, lengths, subunits and concentrations reproduce to within 0.11 % (check 01).
Careful template-matching and connectivity pipeline with explicit validation
Fig. 4, S10-S12; Methods p31-34
Branch junctions are detected with a sub-tomogram-average reference and grid-searched filters. Precision is checked on 250 manually inspected hits (230/250, 95 % CI 0.879-0.950) and connections on 200 (198/200, CI 0.964-0.999), all consistent (check 12). Geometric connections are filtered on STA orientation consistency (≤25°), which is a principled way to build mother-daughter trees.
In situ-derived 3.6 Å F-actin map supports sample preservation
Fig. S1; Table S1; Methods p24-25
Single-particle analysis of filaments from the same extracted keratocytes gives a 3.6 Å map and model. Table S1 bookkeeping is coherent: residues 6-372 = 367, Ramachandran 100.00 %, all-atom count within 0.84 % of a recomputed value with hydrogens (check 13). This is a stronger preservation control than is usual for extracted-cell tomography.
First network-scale view of long filaments interwoven with branched arrays
Fig. 2B-F; Results p9-11
Tracing over tens of µm² recovers filaments up to ~4.75 µm and shows that the ~2.2 % of filaments >1 µm carry ~16.5 % of the polymer. The stated fractions are mutually consistent (check 06), and they are interwoven in z with short filaments rather than layered. This kind of observation needs the large contiguous FOV this method provides.
Interactive data resource and explicit limitations paragraph
Fig. 5; Data availability p21; Discussion p20
Weaknesses
Barbed/pointed-end distribution is an artefact of the polarity rule
major · Results p11; Fig. 2G-H, S6-S8 G-H; Methods p30
Polarity is assigned by labelling the filament end closer to the leading edge as barbed (Methods p30). In a Monte Carlo null model with no polarity information and the Cell1 length mixture, this rule alone gives barbed fractions of 0.740, 0.556 and 0.533 in the first three 100-nm bins and 0.500 from 1-5 µm. That is exactly the reported 'enrichment in the first ~300 nm, then homogeneous and equal distribution' (p11). A strongly polarised network gives a near-identical profile (check 03), so Fig. 2G-H and S6-S8 G-H carry no information on filament polarity or turnover. Fix: drop or reframe these panels, or assign polarity from structure (e.g. subtomogram averaging along filaments, or Arp2/3-defined pointed ends as the Discussion itself suggests) and compare against the null model.
F-actin concentration depends on an unreported hull volume that implies a ~2x thinner network
Concentrations of 895-1036 µM (Table S3) divide subunit counts by the mean of an alpha-shape volume and a Gaussian-isosurface volume around the traced filaments. Their parameters (alpha, blur sigma, iso-level) are not given. These volumes imply a mean thickness of only 78-116 nm (check 02), whereas the paper describes the network as ~200 nm thick (p11) and lamellipodia as 150-200 nm (p2). A slab of area × 200 nm gives 405-521 µM, and × 150 nm gives 540-695 µM. Both lie outside the Aroush 2017 value (1200±300 µM) that the paper presents as agreement. Koestler et al. 2009, cited in the Discussion (p19) as cross-validating the concentration, actually reports ~500 µM F-actin (check 15). Because the hull is built from the traced points, it shrinks to fit them, so the 'agreement' is partly circular. The counting rise of 2.7 nm is also 4.7 % below the paper's own SPA rise of 2.833 nm (check 11). Fix: report hull parameters, give concentrations with explicit thickness assumptions (e.g. from the measured local membrane-to-membrane thickness), and correct the Discussion's cross-validation statement.
Branch-density figures cannot be reproduced and are not corrected for detection errors
major · Results p14; Fig. 4C-E; Methods p32-33; Table S3
'~189 branch junctions per µm²' (p14): 6,954/37.4 µm² = 185.9 and 6,920/37.7 = 183.6. Correcting for the measured ~8 % false positives gives ~170/µm² (95 % CI 162-175) (checks 04, 12). 'One junction per 0.92 µm' cannot be reproduced: the only reported filament length for this montage (Table S3, 5,512 µm) gives 0.79 µm. The Fig. 4 analysis uses IsoNet2 traces whose total length (~6,400 µm implied, +16 %) is never reported, so tracing output depends on the denoiser. Recall is not estimated at all. The 'agreement' with Vinzenz 2012 (0.75-0.8 µm) is therefore not a validated cross-check. Reproducing the 0.92 average together with the zone values (1/0.5 µm within 1.5 µm, 1/4-8 µm beyond) needs about half of all filament length within 1.5 µm of the edge, which cannot be checked without stripe data (check 05). report the IsoNet2 trace length, per-stripe lengths, areas and junction counts, FP-corrected densities and a recall estimate (e.g. from a manually annotated sub-volume).
Questions for the authors
What alpha value, Gaussian blur sigma and iso-level define the two hull volumes in Table S3? What concentration do you obtain with a volume defined by the measured membrane-to-membrane thickness of each lamellipodium?
What is the total traced filament length of the IsoNet2 vectorization used in Fig. 4? Does 6,954 junctions divided by that length give 0.92 µm? How many filaments and junctions per µm² does each denoising branch give for the same montage?
Can you show that the barbed/pointed-end profiles in Fig. 2G-H differ from those produced by applying the same 'closer to the edge = barbed' rule to filaments with randomised orientation?
What is the recall of branch-junction detection, e.g. against a fully manually annotated sub-volume, and how many filaments >1 µm have zero detected junctions after correcting for it?
What is the measured residual misregistration at tile seams (in nm) after SOFIMA stitching, and how does tracing continuity at seams compare with tile interiors?
Was the beam diameter 1.38 µm (text) or 1.96 µm (Table S2)? Does filament STA resolution differ between regions exposed once and regions exposed up to 4-6 times?
Do the lateral-heterogeneity and branch-density trends hold in Cell1 and the second Cell2 montage? Were the Arp2/3 analyses run on them?
Verification
Only the PDF was available: no code, no traces beyond one browsable montage, and the EMDB/PDB entries are still on hold. Verification was therefore limited to recomputation, internal-consistency checks, simulations of the analysis rules and literature look-ups (17 scripted checks). Seven were confirmed: Table S3 arithmetic, montage area and tile geometry, length-distribution feasibility, template-matching precision CIs, Table S1, z-filter bias and data availability. Eight showed discrepancies. Two of these bear on main claims: a polarity-free null model reproduces the reported barbed-end profile, and the hull volumes behind the ~1 mM concentration imply a 78-116 nm thick network against the stated ~200 nm, while a cited source (Koestler 2009) reports ~500 µM. The others concern the overstated area comparison, beam geometry and several small numerical slips. Two were inconclusive: the 0.92 µm per junction figure cannot be reproduced from reported lengths, and the branch-profile consistency needs unreported stripe data. None of the filament tracing, template matching or stitching itself could be rerun.
Koestler, S. A. et al. (2009). F- and G-Actin Concentrations in Lamellipodia of Moving Cells. PLOS ONE 4(3), e4810.
Discussion (p19) cites this work with Aroush 2017 as cross-validating the measured F-actin concentration (0.8-1 mM) and branch density. Its abstract reports F-actin ~500 uM and G-actin ~150 uM, about half the paper's 895-1036 uM. Its G/F ratio (~0.3) also contradicts the 2-fold soluble pool behind 'up to 2-3 mM'. It does not support the stated agreement (work/verify/15_refs_summary.log).
Manhart, A., & Schmeiser, C. (2017). J. Math. Biol. 74(1-2), 169-193.
The printed DOI 10.1007/s00285-0161027-z lacks a hyphen; the correct DOI is 10.1007/s00285-016-1027-z (Crossref resolves the corrected form; published online 2016).
Wu, M. et al. (2025). The WAVE complex forms linear arrays at negative membrane curvature ... bioRxiv 2024.07.08.600855.
Cited as 2025, but Crossref dates the preprint to 2024. Minor bibliographic inconsistency.
Vinzenz, M. et al. (2012). Actin branching in the initiation and maintenance of lamellipodia. J Cell Sci.
Load-bearing for the claimed agreement (one branch per ~0.75-0.8 um of filament, 'mouse fibroblasts', p14). The abstract does not state these figures, and the full text could not be checked here, so the specific values and cell type remain unverified rather than contradicted.
Suggestions
Replace the edge-proximity polarity rule with structural polarity (e.g. subtomogram averaging along filaments) or Arp2/3-defined pointed ends, and always plot the rule-only null model alongside.
Report the hull parameters and give F-actin concentrations under explicit, measured thickness assumptions. Correct the Discussion's claim of agreement with Koestler et al. 2009.
Tabulate per-montage and per-denoiser trace lengths, junction counts, FP-corrected densities and a recall estimate. Provide the stripe-wise data behind Fig. 4C-E.
Quantify stitching accuracy (seam residuals in nm, seam-vs-interior trace continuity) and benchmark against 2D-projection montage reconstruction on at least one dataset.
Increase biological replication, or explicitly frame the biological findings as observations from two cells. Add statistical tests for the regional orientation and density comparisons.
Tone down kinetic and state claims (debranching vs depolymerisation; protrusive/pausing/retracting) unless supported by correlative live imaging.
Harmonise the headline area (100 / 120 / 127 µm²) and support the 'larger than published montages' statement with a table of prior fields of view.
Release the SOFIMA configuration and analysis code, all five stitched volumes with traces, and the raw tilt series (EMPIAR) with the preprint rather than after acceptance.
Correct the beam-diameter description and add a quantitative test of dose effects in multiply exposed regions.
Ethics and integrity
No integrity concerns found. The numbers checked are internally consistent apart from ordinary slips, and the paper contains no text directed at reviewers. Generative-AI use (ChatGPT, Claude, Gemini for scripts and text) is declared. Animal work is described as following institutional guidelines, but no permit or protocol number is given; one should be added.
Scope of this review
Only the PDF (main text and supplement) was examined. The analysis code is withheld until acceptance, four of five montages, all raw tilt series and the filament traces behind Table S3 and Figs. 2-4 are not available, and EMD-100760 / PDB 35PI are not yet public. The SOFIMA stitching, filament tracing, template matching and connectivity analyses could not be rerun, and the webKnossos volume was not inspected beyond confirming that the link resolves. Full texts of Aroush 2017, Vinzenz 2012, Hylton 2026 and Brown 2026 could not be retrieved, so the specific values attributed to them were checked only against abstracts.
A webKnossos link to Cell2 montage#1 with its traces resolves (check 17), which lets readers browse a stitched volume directly. The Discussion openly lists the main caveats: membrane extraction, truncation at montage borders, polarity uncertainty and missed junctions in crowded regions.
Fix:
Biological generalisations rest on two cells, with no statistics
major · Results p8-17; Figs. 2-4, S9; Discussion p20
All filament analyses come from four montages of two cells (the fragment montage is used for templates). The Arp2/3 and connectivity analysis uses a single montage of one cell. Claims that the network is 'markedly heterogeneous', that branch distribution varies with density and distance, and the orientation differences between regions (Fig. 3C/F/I) are shown without variability estimates or tests. The Discussion's 'reproducible network-scale trends' (p20) is not backed by replicates. Fix: add cells (or at least run the Arp2/3 analysis on all montages), report per-cell values with dispersion, and test the regional comparisons.
Protrusive/pausing/retracting states and kinetics are inferred from static snapshots
major · Results p12-14; Fig. 3, S9; Fig. 4A-C
Regions are labelled 'protrusive-like' or 'pausing-like' from edge curvature alone (Fig. 3 legend). Yet the text claims 'a continuous structural view of locally protrusive, pausing, and retracting states' (p12). Likewise, 'de-branching occurs faster than filament de-polymerization' (p14) is a kinetic statement drawn from a single fixed spatial profile and an unstated retrograde-flow assumption. The Discussion (p19-20) concedes that correlative live imaging would be needed. Fix: soften these statements to correlations with edge geometry, or add pre-fixation live imaging of the same cells.
Stitching accuracy is validated only qualitatively; the size claim is inconsistent and overstated
major · Abstract; Results p7-8; Methods p29; Fig. S3-S5
Stitching is validated by annotators tracing filaments across seams (Fig. S3, S4). The Methods (p29) state that no quantitative similarity metric was used, and no residual misregistration in nm, no seam-vs-interior tracing statistics and no comparison with 2D-projection stitching on the same data are given. The maximum area is stated three ways: ~100 µm² (abstract), 120 µm² (p8) and ~127 µm² (p7, Fig. 1D). '2-3 times larger than published montage attempts' (p8) is 1.85-1.95x against the only cited prior work whose abstract states an area (Chua et al. 2026, 65 µm²) (check 09). Fix: report seam displacement statistics (e.g. from the SOFIMA flow residuals or fiducial features), harmonise the area figure, and back the comparison with a table of prior FOVs.
'Long unbranched' filaments are not quantified
minor · Results p15-17; Fig. 4F-H, S12, S13
Only 2,236 of 6,954 junctions (≤32 %) end up in connected trees (check 12), and detection recall is unknown. So a filament with no assigned junction is not shown to be unbranched, and tree sizes and generation depths are lower bounds. Fig. S13A shows seven examples, but no count or fraction of >1 µm filaments without junctions is given. The claim that long filaments are 'previously underappreciated' (p11) also sits uneasily with Small et al. 1995 and Svitkina et al. 1997, which the paper cites on p9 and which described long filaments in keratocyte lamellipodia. Fix: report the distribution of junctions per filament by length class, with recall-based uncertainty.
Beam geometry and dose bookkeeping are misdescribed
minor · Results p5, p7; Methods p26; Table S2
The text says the beam was matched to the 1.38 µm FOV / K3 short axis (p5, p26), but Table S2 lists 1.96 µm, which is the square diagonal or K3 long axis. A 1.38 µm beam would leave 6-11 % of the grid unexposed (check 07). With 1.96 µm the maximum cumulative dose of ~400 e/Ų holds, but >200 e/Ų covers 53-72 % of the area rather than small corners, and the multiplicity reaches 6 at 50° tilt for 15 % overlap. 'No observable beam damage' is qualitative. Fix: correct the description and add a quantitative damage test, e.g. STA resolution of filaments from single- vs multi-exposed regions.
Reproducibility: code withheld and most data unreleased
minor · Data and code availability p21-22
Analysis code is to be released 'after the final acceptance' (p22). Only one of five montages is shared, raw tilt series are not listed, and EMD-100760 / PDB 35PI are deposited but still on hold (check 17). None of the Table S3 or Fig. 2-4 quantification can currently be rerun. For a paper whose main contribution is a workflow, this is a significant limitation. Fix: release the SOFIMA configuration, the analysis scripts, all stitched volumes with traces, and the raw tilt series (EMPIAR).
Discussion '0.8-1 mM' vs Table S3 0.895-1.036 mM. Subunit counts 3.23/3.44 M where the table (3,239,038; 3,449,019) rounds to 3.24/3.45 M (check 14). '~25-fold' pixel-to-filament ratio is 20.7-23.7 (check 10). '36 nm ... equivalent to the crossover' vs 39.5 nm from the paper's own helical parameters (check 11). Junctions outside the outline 0.489 % reported as 0.48 %. Fig. S9 legend defines long filaments as both '>500 nm' and '<500 nm' (main text: >1 µm). Immunofluorescence incubation '1 to 2 hours' vs 'after 1 hour'. 'Z from 250 to 220' is garbled. The contact e-mail domain differs between the title page (ista.ac.at) and p22 (ist.ac.at). The DOI of Manhart & Schmeiser 2017 is malformed.
11 of 13 conversions agree within 3 % (FOV 1.379 um, overlap 409/614 px, 13.48 A, 540/692 nm, 16.2/27.0 nm, 27.04 nm). The ~25-fold ratio is 20.7-23.7 for a 7-8 nm filament (25-fold would need 8.45 nm). This is minor and does not affect conclusions. Note: slices are labelled 1.352 nm while 4 x 3.371 A = 1.348 nm (0.3 %).
Recomputed 13 conversions, tolerance 3 %
36 nm minimum filament length is equivalent to the crossover distance; 2.7 nm axial rise used for subunit counting; SPA helical rise 28.33 A, twist -167.09 deg
The paper own SPA parameters give 13.94 subunits and 39.5 nm per crossover; 36 nm is 8.9 % shorter (canonical values give ~37 nm). The counting rise (2.7 nm) differs from the SPA rise (2.833 nm) by 4.7 %, so subunit counts and concentrations would be 4.7 % lower with the paper own value. The SPA rise of 28.33 A is ~3 % above the usual ~27.5-27.8 A for F-actin, which may point to a pixel-size calibration issue (0.9551 A/px) worth checking. Minor; does not change conclusions.
Crossover = rise x 180/(180-|twist|) for the paper SPA parameters and canonical values; sensitivity of counts to the rise
Template-matching precision ~92 % (250 inspected); 99 % of 200 retained connections correct; 2,236 of 2,690 geometric connections retained; trees represent the Arp2/3 network
230/250 = 0.920 (95 % CI 0.879-0.950), i.e. ~556 false positives (345-840) among 6,954. 198/200 = 0.990 (CI 0.964-0.999). 2,236/2,690 = 83.1 % retained. The percentages are consistent. Two consequences the paper does not state: (i) the headline density is not corrected for false positives (FP-corrected: 6,398/37.7 = 170/um2, CI 162-175, vs ~189); (ii) at most 2,236/6,954 = 32 % of junctions (35 % of the estimated true ones) are linked into trees, so tree sizes and generation depths are lower bounds. Recall is not estimated.
Exact Clopper-Pearson CIs; expected false positives; fraction of junctions linked into trees
Table S1: 367 residues (6-372), Ramachandran percentages, 28,905 atoms for 5 actin + 5 ADP + 5 phalloidin; SPA bookkeeping and 3.6 A resolution
Residues 6-372 = 367. Ramachandran 0 + 2.47 + 97.53 = 100.00. Computed all-atom model with H = 29,150 vs 28,905 reported (-0.84 %, within the spread expected from protonation choices); heavy-only would be 14,705, so the table count includes hydrogens. Particle bookkeeping is coherent (386,378 -> 204,916 -> 129,656), and 3.61 A is reported as 3.6 A.
Atom count from the UniProt A8WG05 sequence (residues 6-372) with hydrogens at pH 7 plus ADP and phalloidin; arithmetic on the micrograph/particle counts
Text subunit counts 3.98/2.04/3.23/3.44 million; Discussion F-actin ~0.8-1 mM; total actin up to 2-3 mM
3,239,038 and 3,449,019 round to 3.24 M and 3.45 M; the text gives 3.23 M and 3.44 M (truncated). The Discussion range 0.8-1 mM does not match Table S3 (0.895-1.036 mM): the lower bound is 10.6 % below the smallest value and the upper bound is below the largest. F + 2F = 2.68-3.11 mM, slightly above 'up to 2-3 mM'. Presentation-level only.
Rounding and arithmetic against Table S3
All 95 references exist; load-bearing citations support the statements (Aroush 2017: 1200+-300 uM F-actin and ~2-fold soluble pool; Vinzenz 2012: one branch per 0.75-0.8 um; Discussion: agreement with Aroush 2017 and Koestler 2009 cross-validates concentration and branch density)
All 95 references resolve: 93 via Crossref; SOFIMA (Zenodo 10.5281/zenodo.10534541) and cryo-CARE (arXiv 1810.05420) via DataCite. Four year differences are online-first vs issue years, and the Manhart 2017 DOI in the printed list lacks a hyphen (s00285-0161027-z). Aroush 2017 abstract: about two-thirds of lamellipodial actin is diffusible, consistent with the 2-fold assumption; the 1200+-300 uM value is not in the abstract (not checked). Vinzenz 2012 abstract does not state a 0.75-0.8 um branch spacing (not checked). Koestler 2009, which the Discussion (p19) cites alongside Aroush as cross-validating the concentration, reports F-actin of ~500 uM (G-actin ~150 uM): about half the paper's 895-1036 uM, close to the slab-volume estimates of check 02 (405-695 uM), and its G/F ratio (~0.3) contradicts the 2-fold soluble pool used for 'up to 2-3 mM'.
tools/check_refs.py (Crossref/arXiv), DataCite lookups for Zenodo/arXiv DOIs, Europe PMC abstracts of Aroush 2017, Vinzenz 2012, Koestler 2009
Excluding traces within 0-20 deg of the z axis (missing-wedge clean-up) does not bias the z-distribution used to reject a two-layer organisation
Unconstrained isotropic fraction within 20 deg of z = 6.03 %. In a 100/200 nm slab the filter removes 2.3 %/3.8 % of short (<0.5 um) filaments and 0 % of long (1-2 um) filaments. Midpoint-z SD changes by +0.7 % (short) and 0 % (long). The filter is length-dependent but too small to create or hide a two-layer separation. This tests only the filter, not missing-wedge effects on tracing itself.
Monte Carlo (seed 2): isotropic filaments confined to a 100 or 200 nm slab; fraction removed per length class and change in midpoint-z spread
F-actin map and model deposited as EMD-100760 / PDB 35PI; Cell2 montage#1 and its traces available on webKnossos; code after final acceptance
Both deposits exist but are not public: EMD-100760 status PROC (title still suppressed, updated 2026-11-06), and PDB 35PI is UNRELEASED/HOLD FOR RELEASE (deposited 2026-11-06). The webKnossos link returns HTTP 200 (application page; volume content not inspected). Only 1 of 5 montage volumes is shared, no raw tilt series are listed, and the analysis code is withheld until acceptance, so none of the quantitative network analyses (Table S3, Figs 2-4) can be reproduced at present.
HTTP queries to the EMDB API, RCSB holdings API and the webKnossos link
Table S3: subunits = cumulative length/2.7 nm; mean F-actin concentration 1035.59/960.59/894.93/944.14 uM = N/(N_A*mean(V_iso,V_alpha)); mean filament length 0.200/0.245/0.217/0.235 um
Subunits x 2.7 nm = 1.0756/0.5512/0.8745/0.9312 cm (table 1.08/0.55/0.87/0.93 cm, consistent with rounding). Recomputed C = 1035.23/961.66/894.93/944.31 uM vs table 1035.59/960.59/894.93/944.14 (max |rel| 0.11 %, explained by volumes rounded to 2 decimals; tolerance 0.5 %). Mean length 0.2006/0.2453/0.2175/0.2355 um vs 0.200/0.245/0.217/0.235 (<=0.28 %). The table is internally consistent; this does not validate the volume definition (see check 02).
Recomputed subunits, concentrations and mean lengths from the Table S3 entries
The hull volumes used for the ~895-1036 uM F-actin concentration correspond to a network ~200 nm thick (p11) and the result agrees with Aroush et al. 2017 (1200+-300 uM)
Mean of the two hull volumes / montage area gives 78, 94, 116, 109 nm (V_alpha/A 65-101 nm; V_iso/A 92-132 nm). The paper describes the network as ~200 nm thick (p11) and lamellipodia as 150-200 nm (p2). With a slab of A x 200 nm the concentrations would be 405-521 uM, and with 150 nm 540-695 uM; both fall outside Aroush 1200+-300 uM. For Cell2 m1 the filament-defined outline (37.7 um2, Methods p33) is about the same as the montage area (37.4 um2), so the thin implied thickness is not caused by empty montage area. Using the SPA rise 2.833 nm lowers every C by 4.7 % (e.g. 1035.6 -> 987 uM). The concentration and its agreement with the literature therefore depend on the unreported alpha/isosurface parameters, which hug the traced filaments.
Implied mean thickness V/A per montage; concentration recomputed for a slab A x 150/200 nm; sensitivity to the axial rise (2.7 nm vs the paper SPA rise 2.833 nm)
Barbed ends (end closer to the leading edge) are enriched in the first ~300 nm, and barbed and pointed ends are otherwise homogeneously and equally distributed up to 5 um
With no polarity information, the rule gives barbed fraction 0.740+-0.008 in 0-100 nm, 0.556 in 100-200 nm, 0.533 in 200-300 nm and 0.500 mean over 1-5 um; a polarized network gives a near-identical profile (0.848, 0.603, 0.549, then ~0.50). So the reported pattern (enrichment within ~300 nm, then equal) follows from the definition plus the boundary and carries no information on filament polarity; it cannot support the inference of a balanced barbed/pointed distribution. The criterion was changed after the first run from f[0]>0.8 to z>5 above 0.5 (disclosed in the script).
Monte Carlo null model (seed 1, 200k filaments): uniform positions in a half-plane bounded by the edge, isotropic or polarized (+-35 deg) orientation, length mixture matched to Cell1 m1 (mean 0.195 um, 91.9 % <0.5 um, 2.1 % >1 um, 16.1 % of length in >1 um filaments); paper rule applied
Cell2 montage#1: ~189 branch junctions per um2, one junction per 0.92 um of filament (close to Vinzenz 2012, 0.75-0.8 um); 34 of 6,954 junctions (0.48 %) outside outline
6,954/37.4 um2 = 185.9/um2 (-1.6 % vs 189); 6,920/37.7 = 183.6 (-2.9 %); 189/um2 would need 36.8 um2. The only reported filament length for this montage (Table S3, cryo-CARE traces, 5,512 um) gives 0.793 um per junction, not 0.92. 0.92 would need ~6,370-6,400 um of IsoNet2 traces (+15.5 %), which is not reported, so the 0.92 value cannot be reproduced. 0.79 would be even closer to Vinzenz 0.75-0.8. 34/6,954 = 0.489 % (reported 0.48 %, truncated rather than rounded).
Arithmetic from the junction count, montage/outline areas and the Table S3 cumulative length
Branch density ~1 per 0.5 um filament within 1.5 um of the edge, ~1 per 4-8 um beyond, together with the global average of 1 per 0.92 um
Reproducing a global 0.92 um/junction needs f = 0.48-0.51 of all filament length within 1.5 um (back zone 4-8 um/junction), with 88-94 % of junctions in that band; with 0.79 um/junction (Table S3 length), f = 0.58-0.61. If the 0-1.5 um band were ~25 % of the analysed area (equal-area stripes to 6 um, an assumption), filament density there would have to be ~3x the rear. Fig 4C stripe values are not tabulated and stripe areas are not given, so this cannot be decided; the paper should report per-stripe lengths, areas and junction counts.
Two-zone mixing equation solved for the fraction f of filament length within 1.5 um
Cell1 m1: N=53,632, mean 0.200 um, range 36 nm-4.75 um, ~91.6 % <500 nm, ~2.2 % >1 um containing ~16.5 % of F-actin
Total length 10,756 um, mean 0.2006 um. Implied mean of the 1,180 filaments >1 um = 1.504 um (feasible within 1-4.75 um). Implied mean of the 49,127 filaments <0.5 um = 0.115-0.149 um (feasible). The 36 nm floor equals the Amira minimum length 360 A. The stated fractions are mutually consistent. This is a feasibility check only; the histogram itself cannot be recomputed without the traces. Note: >1 um filaments are 2.2 % of filaments and 16.5 % of polymer.
Feasibility bounds: implied class means from N, total length (Table S3) and the stated fractions
Beam diameter matched to the 1.38 um camera field ('fit the short axis of the K3') to minimise beam overlap; ~100 e/A2 per tile, max ~400 e/A2 in 4-fold overlap regions
Table S2 beam 1.96 um equals the K3 long axis (5760 px x 3.371 A = 1.942 um) or the square diagonal (1.951 um), not the 1.38 um short axis stated on p5/p26. A 1.38 um beam would leave 6-11 % of the tile grid unilluminated, so 1.96 um is presumably what was used. Per-tile dose 51 x 1.96 = 99.96 (and 51 x 1.76 = 89.76) e/A2 matches 100/90. With D = 1.96 um the max cumulative dose is 400 e/A2 (349 with cos dilution), so the ~400 ceiling holds. But the dose-elevated area is not confined to small corners: >200 e/A2 covers 53 % (10 % overlap) to 72 % (15 % overlap) of the area and >300 e/A2 covers 12.5-23 %, versus a detector-overlap area of 22-33 %. At 50 deg tilt the multiplicity reaches 6 for 15 % overlap. The text understates beam overlap; the no-damage claim is qualitative.
K3 geometry; dose map on a 9x9 tile grid (10 %/15 % overlap, beam D = 1.38 or 1.96 um, 51 tilts x 1.96 e/A2, tilt-elongated elliptical footprint, with/without cos dilution)
Montage areas 81.6/37.4/51.6/55.4/~127 um2 consistent with 54/23/31/35/80 tiles, 1.38 um FOV, 10-15 % overlap; ~78-270 min for 23-80 tiles
All five reported areas lie inside their bounds (e.g. Cell1 m1 81.6 in [74.2,102.8]; Fragment1 127 in [124.0,153.1] um2); area per tile 1.51-1.66 um2. Throughput 3.39 vs 3.38 min per tile (~4 s per tilt image), consistent between the smallest and largest datasets.
Area bounds nstep^2 to nFOV^2 per montage; minutes per tile
Largest reconstructed area: up to ~100 um2 (abstract), up to 120 um2 and 2-3 times larger than published montage attempts (p8), ~37-127 um2 (p7, Fig 1D)
The paper gives three different maxima for the same datasets: ~100 um2 (abstract), 120 um2 (p8) and ~127 um2 (p7, Fig 1D). Among the cited prior works, the only abstract that states an area is Chua et al. 2026 (fields of view up to 65 um2). Against that, 120 um2 is 1.85x and 127 um2 is 1.95x, below the claimed 2-3x. Brown et al. 2026 report whole-cryo-FIB-lamella montages (>10 um FOV) and Hylton et al. 2026 give no area in the abstract; full texts could not be retrieved (HTTP 403/redirect), so these comparisons are open. The retrieved abstracts confirm that Peck 2022 stitches 2D projections at each tilt before reconstruction; Hylton 2026 (MontageMaker merging overlapping tilt series) and Yang 2023 (tiles can be processed individually) are less clear-cut cases of the p7 characterisation.
Extracted the in-paper statements; fetched abstracts of the cited montage cryo-ET papers (Europe PMC/Crossref) and extracted reported fields of view