The guarantees (Thms 1-2, Table 4) check out, but the central evaluator-calibration construction is always beaten by plain reference evaluation on the calibration data it already needs, the Table 2 power column cannot be reproduced from the stated design, and the Monte Carlo never tests the candidate-dependent bias it is meant to illustrate.
Soundness
2/4
Presentation
3/4
Contribution
2/4
Confidence
4/5
✓ 9 confirmed✕ 6 discrepancy◐ 1 inconclusive
Summary
The paper proposes Evidence-Governed Evolution (EGE), a framework that decides whether a self-generated change to an autonomous agent (a new prompt, memory schema, tool configuration, workflow, and so on) should become persistent. Candidate generation is kept separate from confirmatory adoption. A frozen candidate must show a practical improvement ≥δ on a prespecified primary metric against the incumbent, non-inferiority within ε on protected capabilities against a fixed versioned reference, pass mandatory governance checks, and survive a bounded canary deployment (Secs. 3-4, 7).
The statistical core (Sec. 5) is a Hoeffding lower confidence bound on operational-evaluator paired differences, minus a Hoeffding upper bound on evaluator-reference discrepancy W=DE−DR estimated from an independent, candidate-specific calibration sample (eqs. 14-16). With allocation , Theorem 1 gives simultaneous coverage over a countable, adaptively generated candidate stream. Theorem 2 bounds cumulative degradation along a reference lineage by via bridge tests (Sec. 6). Sample-size conditions (eqs. 20-21, Table 4) and a stylised Monte Carlo (Sec. 8, Tables 2-3) complete the paper.
The paper is explicit that it offers conditional guarantees and no evaluation on a real agent. It limits its novelty to the composition and formalisation of standard tools (Sec. 1, p.2-3).
The Hoeffding radii in eqs. (14)-(15) match a symbolic derivation exactly, and the allocation (17) sums to exactly α (checks 04-05). The proof of Theorem 1 (per-(j,r) conditional bound, deterministic inclusion, countable union bound) is correct. An adaptive adversarial Monte Carlo found no violation (check 03). The global, non-resettable audit index shared by candidate and bridge tests (p.8, p.10) is a design point that is often missed and is handled properly here.
Explicit reference-lineage accounting
Sec. 3 eq. (3) (p.4); Sec. 6, Theorem 2 (p.10-11)
Primary metrics are compared with the incumbent and protected metrics with a fixed versioned reference (eq. 3). Bridge tests (Sec. 6) make the cost of moving the protected baseline explicit, so drift through many small accepted steps cannot go unnoticed. Theorem 2 is a simple telescoping argument, but it is correct and was confirmed by simulation (check 12).
Candid scoping of claims
Abstract; Sec. 1 (p.2-3); Sec. 10 (p.15)
The abstract, the introduction (p.2-3), Sec. 8 and Sec. 10 repeatedly say that the guarantees depend on bounded paired scores, fresh sampling and a valid reference construct, that no real-agent validation exists, and that the novelty lies in composition rather than new concentration tools. The limitations (dependence, construct validity, rare catastrophic events, irreversible external actions) are thorough.
Weaknesses
Evaluator calibration is dominated by reference-only evaluation on the same data
major · Sec. 4.1 (p.6); Sec. 5.2 eqs. (14)-(16) (p.7); Sec. 5.4 and Table 4 (p.9, p.13)
Each calibration observation W=DE−DR needs reference scores for both the candidate and the comparator, so the m calibration instances already provide paired reference differences . A plain Hoeffding LCB on those has radius . The EGE radius is at least , so it is strictly larger for any , even . Across a 1,470-point grid the reference-only radius is at most 0.494x the EGE radius. In the Table 4 setting a reference-only gate needs = 3,674 / 7,358 / 11,042 reference-scored instances, against EGE's 67,651 / 126,597 / 185,543 plus 16,913-46,386 evaluator runs. In the Table 2 design it reaches 100% power with 0/3,000 harmful campaigns, against EGE's ~68% (check 02). With range-based bounds, then, calibrating the cheaper evaluator adds cost and gives no statistical gain, which undercuts contribution (2). compare against the reference-only gate explicitly, and switch to variance-adaptive estimators (prediction-powered / control-variate style with empirical-Bernstein or betting confidence sequences) under which the many cheap evaluator scores can actually reduce the number of reference labels needed.
Questions for the authors
Calibration already requires reference scores on m paired instances. Under what conditions, and with which estimator, does EGE need fewer reference adjudications than a reference-only LCB on those same instances? Under the Hoeffding bounds in eqs. (14)-(16) it never does (radius ratio <= 0.494 in our grid).
Can you release the simulation script for Table 2 and state R and whether j indexes candidates or tests? Our re-implementation gives EGE power of 67-68% at n=5,000, essentially flat in , not 52.6/76.2/65.7%.
Verification
16 checks were run, each with a script and log. Confirmed (9): the Hoeffding radii, the allocation sum, Theorem 1 (adaptive adversarial MC), Theorem 2 (lineage MC), eqs. (20)-(21), all 12 entries of Table 4, the mismatch experiment (Table 3), the binomial limits, and that all 25 references resolve. Discrepancies (6): the Table 2 EGE power column at n=5,000 does not reproduce (67-68% and flat in b, vs 52.6/76.2/65.7%); the calibration construction is uniformly dominated by a reference-only bound on the calibration data; the Monte Carlo uses constant bias, so it does not test candidate-specific calibration; the first power display in Sec. 5.4 is false; the promised reproducibility files are missing; and six closely related works are not cited. One check (candidate-level vs per-test acceptance bound) is inconclusive. The theorems are sound. The problems lie in the efficiency premise of the calibration construction and in the empirical illustration.
Every checked reference resolved to the cited work.
Suggestions
Add the reference-only gate (a Hoeffding LCB on DR from the calibration instances) as a baseline in Sec. 5 and Sec. 8, and state when evaluator calibration is worth its cost.
Replace the range-based bounds with variance-adaptive ones (empirical Bernstein, betting confidence sequences, or a PPI-style rectified estimator) so that cheap evaluator scores can reduce the number of reference labels needed.
Rerun Table 2 with the released script, state R and the j indexing, and add a candidate-dependent-bias condition plus a global-calibration baseline.
Publish the simulation code, seed and campaign-level JSON in a public archive, and link it from the paper.
Add a related-work subsection on prediction-powered inference, Learn-then-Test, Seldonian algorithms, ease.ml/ci, and online multiple testing, and update Table 1.
Ethics and integrity
No integrity concerns. The first-page footnote discloses that ChatGPT was used for research planning, literature discovery, drafting and revision. All 25 references were verified to exist and to match their citations. No instructions aimed at reviewers were found in the paper or its LaTeX source. The irreproducible Table 2 power column (check 01) is reported as a discrepancy. With the code unavailable, a reporting or implementation error is the most plausible explanation, and nothing beyond that is suggested.
Scope of this review
The review is based on the PDF and the full LaTeX source. No code, simulation script or supplementary JSON was available, either in the arXiv bundle or via a link, so Table 2 was checked only through an independent re-implementation of the design described in Sec. 8.1, under several readings of the unstated details. The paper has no real-agent experiments to examine. The literature comparison was limited to confirming specific suspected overlaps.
Audit-planning arithmetic is exact and exposes the cost
Sec. 5.4 eqs. (20)-(21); Table 4 (p.13)
All 12 integers in Table 4 (n = 16,913/31,650/46,386, m = 67,651/126,597/185,543, and the totals) are reproduced exactly from eqs. (20)-(21) (check 08). Eqs. (20)-(21) give 2hE+2hb=g exactly (check 07). Reporting these large numbers openly is to the paper's credit.
Concrete operational protocol
Sec. 7, Fig. 1, Algorithm 1 (p.11-12); App. D (p.19-20)
The state machine Candidate -> Audit-passed -> Canary -> Committed (Fig. 1, Algorithm 1) and the implementation checklist (App. D) are specific and useful to practitioners: an immutable canary configuration, stop authority, rollback packages, compensating actions, and risk tiers. The paper also states that a confidence bound cannot replace a permission boundary.
Mismatch stress test and binomial reporting reproduce
Sec. 8.2, Table 3 (p.13-14)
The calibration-mismatch experiment (3,000/3,000 harmful acceptances) reproduces under both readings of R (check 09). The exact binomial limits (9.98e-4 upper limit for 0/3,000; Clopper-Pearson [0.9988, 1.0000]) are correct (check 10). The experiment usefully shows that the guarantee fails when the calibration distribution differs from the audit distribution.
m
DR
DR
2ln(1/(e+c))/m
hE+hb
hb=22ln(1/c)/m
n
n→∞
m
Fix:
Table 2 EGE power column not reproducible from the stated design
major · Sec. 8.1, Table 2 (p.12-13)
Table 2 reports EGE beneficial-acceptance power of 52.6% / 76.2% / 65.7% at n=m=5,000 for b = 0 / 0.10 / 0.25. Under the DGP in Sec. 8.1, b cancels in expectation in LR (dˉE has mean Δ+b, wˉ has mean b), so power should be almost flat in b. A re-implementation with the stated seed gives 67.4 / 67.7 / 68.5% (R=2, MC SE 0.4 pp), and a normal approximation gives 67.95 / 68.07 / 68.37%. Three other readings of the unstated details (R∈{2,3}, per-candidate vs per-test index) give 45.6-63.4%, always with a spread across b of at most 1.2 pp. No reading reaches 76.2%, and none produces the claimed 23.6 pp non-monotone swing (check 01). The harmful-acceptance columns and the 100% entries do reproduce. Because the promised script and JSON are not available (check 14), the source of the difference cannot be traced. Fix: release the simulation code, state R and the indexing of j, and correct or explain the column.
Monte Carlo does not exercise candidate-dependent evaluator optimism
major · Abstract; Sec. 1 (p.3); Sec. 8.1 design (p.12-13)
The abstract (p.1), contribution 4 (p.3) and the conclusion say the Monte Carlo illustrates the importance of calibration under candidate-dependent optimism. In the design, however, one constant b applies to every candidate in a condition. In that design, a single pooled (global) calibration sample is just as safe as EGE (0/3,000 harmful campaigns) and more powerful (94.0-94.4% vs 67.4-68.5%) (check 11). The reported experiment therefore cannot show why calibration must be candidate-specific. A variant the paper did not run (harmful candidates with bias 0.60, beneficial with 0) does separate the two: EGE 0/3,000 harmful and 100% power, global calibration 2,458/3,000 harmful and 6.7% power. Fix: add a candidate-dependent-bias condition and a global-calibration baseline.
No evaluation on any agent, and sample sizes of questionable practicality
major · Sec. 8.3 (p.13-14); Table 4 (p.13); Sec. 10 (p.15)
All empirical content is a synthetic two-point-distribution simulation with 5,000-80,000 paired observations per test. Table 4 requires up to ~232k audit observations per candidate per metric, including up to 185k reference adjudications. Sec. 8.3 only describes a protocol for a future study, and itself says this study 'remains necessary'. Whether the paired design (running the incumbent and candidate on the same instances), the fresh-sample requirement and the reference construct are feasible for real prompt or tool updates is never shown. Fix: a small real-agent case study (e.g. prompt updates on a public agent benchmark with an LLM judge as E and human or gold labels as the reference).
Closely related statistical prior work is missing
major · Sec. 2 and Table 1 (p.3-4)
Six closely related works are not cited, and they overlap substantially with what the paper claims as its composition (check 16): prediction-powered inference (Angelopoulos et al. 2023), which uses the same rectifier structure as W=DE−DR; Learn-then-Test (2021), which certifies configurations with Hoeffding p-values and FWER control; Seldonian / high-confidence improvement (Thomas et al. 2019), which selects a candidate on one split and runs a held-out safety test; ease.ml/ci (Renggli et al. 2019), which gives statistically sound CI conditions for model updates; and online FDR / alpha-investing for countable streams of tests. Without them, Table 1 and Sec. 2 cannot show what EGE adds. Fix: position EGE against each of these explicitly.
Promised reproducibility files are absent
minor · Sec. 8.1 (p.13); Sec. 8.4 (p.14)
Sec. 8.1 says 'full campaign-level counts, confidence intervals, and seed are included in the reproducibility files', and Sec. 8.4 refers to a supplementary simulation script and JSON. The arXiv bundle contains only the .tex, the style file and 00README.json, and the paper gives no repository link (check 14). The paper describes the experiment as 'reproducible', but as distributed it cannot be regenerated from author material.
Incorrect intermediate inequality in the power argument
minor · Sec. 5.4, first display (p.8)
The first display of Sec. 5.4 states LR≥Δ−hE−2hb on the event {dˉ≥μ−hE,wˉ. The true minimum on that event is Δ−2hE−2hb. Counterexample: μ=0.35,b=0.10,hE=0.03,hb= gives LR=0.150<0.180 (check 06). The following 'Consequently ... ≥Δ−2hE−2hb' is correct, but it does not follow 'consequently' from the first display, because it is a weaker bound. Eqs. (20)-(21) are unaffected. Fix: delete the first display.
Acceptance-probability bound is per test, not per candidate
minor · Abstract; Sec. 5.4 (p.9)
The abstract promises 'a lower bound on acceptance probability', but Sec. 5.4 proves ≥1−e−c only for a single test. A candidate must pass the primary test and every protected test, so the guaranteed candidate-level probability is 1−∑(e+c) over the required tests. In the simulation, Hoeffding slack hid this, so it remains a presentation gap rather than a demonstrated failure (check 13).
Three-outcome rule not formalised
minor · Sec. 5.5-5.6, eq. (22) (p.9)
Sec. 5.6 distinguishes accept, reject (evidence of regression) and inconclusive, but predicate (22) only separates pass from fail. No upper-confidence test establishes a regression, so 'reject' and 'inconclusive' cannot be told apart, and the error control for a 'reject' decision is not stated.
Underspecified experiment and drafting artefacts
minor · Sec. 8.1 (p.12); Table 4 caption; Sec. 8.3 (p.13); App. C, App. E (p.18-20); Sec. 3.3 (p.5)
The number of tests R used in the Monte Carlo is not stated (p.12), and the result depends on it (check 01). The text contains revision leftovers: 'corrected sufficient-power condition' (Table 4 caption, p.13) and a study that 'remains necessary before submission to a venue' (Sec. 8.3, p.13). The 'worked decision' in App. E contains no numbers. The sentence that eq. (20) is 'four times' eq. (24) is true only if eq. (24) is read with hE=λg (check 07). The citations to PagedAttention and Sarathi-Serve in Sec. 3.3 are tangential.
b
In the Monte Carlo, the evaluator bias is constant across candidates. Have you run a design where the bias depends on the candidate (e.g. larger for harmful candidates)? In our variant only that design separates candidate-specific calibration from global calibration.
How does EGE differ technically from prediction-powered inference combined with Learn-then-Test or Seldonian-style safety tests, applied to agent configurations?
For a realistic agent update (e.g. a prompt edit evaluated by an LLM judge), how would the paired, fresh audit samples of ~17k-46k instances and the ~68k-186k reference adjudications in Table 4 be obtained?
One-sided exact 95% upper limit for 0/3,000 is about 9.98e-4; the Clopper-Pearson 95% interval for 3,000/3,000 is about [0.9988, 1.0000]; 2,997/3,000 = 99.9%
Upper limit for 0/3,000: obtained 9.9808e-4 vs claimed 9.98e-4. CP lower limit for 3,000/3,000: obtained 0.99877 vs claimed 0.9988. 2,997/3,000 = 99.90%. The count 2,997 matches E[Bin(3000, 1-2^-10)] = 2,997.07, i.e. the probability that a campaign contains at least one harmful candidate. Naive harmful acceptance is therefore essentially 'any harmful candidate present'.
The Monte Carlo illustrates 'candidate-dependent evaluator optimism' and thereby the need for candidate-specific calibration
In the paper's design, global calibration is just as safe as EGE (0/3,000 harmful campaigns for b = 0/0.10/0.25) and more powerful (94.0-94.4% vs 67.4-68.5% beneficial acceptance). The reported experiment therefore does not exercise candidate-dependent optimism and cannot show that candidate-specific calibration is needed. In the candidate-dependent variant, candidate-specific calibration does matter: EGE has 0/3,000 harmful campaigns and 100% power, while global calibration has 2,458/3,000 harmful campaigns and 6.7% power. This is the experiment that would support the paper's point.
In the paper's design (one constant b per condition for all candidates; n=m=5,000, R=2) compared EGE with a global-calibration gate that uses one pooled calibration sample per campaign. Added a variant with genuinely candidate-dependent bias (beneficial 0, harmful 0.60; n=m=20,000), which the paper did not run.
Theorem 2: on the simultaneous-coverage event, Q(A) - Q(A^(0)) >= -(eps_K + sum_k rho_k) along a reference lineage whose bridge tests share the global index
5,577 lineages were fully accepted. There were 0 bound violations on the coverage event and 0 violations overall (<= alpha). Coverage held with probability 0.9957. In the accepted lineages a single step dipped to -0.108, below its tolerance (a coverage failure), but the cumulative bound still held. The bound is attained when every step equals its tolerance (-0.50). The proof is a correct telescoping sum; the result is simple but valid.
Monte Carlo of 200,000 random lineages (K=4 bridges plus 1 candidate) using EGE bounds (n=m=2,000, rho=eps=0.1, alpha=0.5). True steps were drawn from [-0.30, 0.45], so some fall below the tolerance. The proof's telescoping argument was also read.
The audit-planning condition gives 'a lower bound on acceptance probability' (abstract); 'the test passes with probability at least 1 - e - c' (Section 5.4)
Per-test pass rates were 0.9996-0.9999 and candidate-level acceptance 0.99909, all above the per-test bound 0.8176. Hoeffding slack makes the per-test statement hold empirically here, so no violation was observed. Logically, however, the bound the paper proves applies to a single test. A candidate must pass a primary test and every protected test, so its guaranteed acceptance probability is only 1 - sum over required tests of (e+c) (here 0.4529). The paper does not state this. This is a presentation gap, not a demonstrated numerical failure.
Monte Carlo at the minimal (n,m) from eqs.(20)-(21) with alpha=0.9, R=3, g=0.8 (so the bound is not trivial) for 1 primary + 2 protected tests; compared per-test and candidate-level acceptance with 1-e-c and with the union bound 1-R(e+c).
'Full campaign-level counts, confidence intervals, and seed are included in the reproducibility files'; 'supplementary JSON'; 'The supplementary simulation script specifies the random seed, data-generating process, allocation...'
The arXiv bundle contains only the .tex, tmlr.sty and 00README.json. There is no script, JSON or CSV, and the source has no GitHub, Zenodo or OSF link; only openreview.net appears, in the style header. The request has no code URL. The reproducibility files may exist elsewhere, but they are not reachable from the paper, so Table 2 could not be regenerated from author material (see check 01 for an independent re-implementation).
Listed every file in the arXiv submission and searched the LaTeX source for repository links
All 25 bibliography entries exist and match their citations (LLM-assisted literature discovery disclosed)
25/25 resolve to works whose titles match. The 2026 EMNLP/Findings DOIs (Lin, Zhang, Gao b) resolve with matching titles and authors, and arXiv:2607.13104 matches. EvoPrompt matches its arXiv title once 'LLMs' is expanded to 'Large Language Models'. The uses of the references are consistent with their titles. PagedAttention/Sarathi-Serve (Section 3.3, p.5) are tangential but not mis-cited.
Ran tools/check_refs.py (DOIs/arXiv ids via Crossref and arXiv). For the 10 entries without identifiers, ran title searches on arXiv and Crossref plus title lookups on arXiv-id, JMLR and PMLR pages, with a similarity threshold of 0.97. Read the in-text citation contexts for the 2026 agent-evolution papers and for PagedAttention/Sarathi-Serve.
Novelty positioning: the evaluator-calibrated simultaneous LCB and candidate-wise confirmatory adoption testing are a new composition for agent-update adoption, positioned against the related work in Section 2 / Table 1
None of the six is cited, and all six exist. (1) Prediction-Powered Inference (arXiv 2301.09633) gives valid CIs by combining many ML predictions with a small gold-labelled sample via a rectifier, which is the same structure as W = D^E - D^R and mu^E - b in Section 4.1. (2) Learn-then-Test (arXiv 2110.01052) certifies configurations with finite-sample Hoeffding-type p-values and FWER control. (3) Seldonian algorithms (Science 2019, 10.1126/science.aag3311) select a candidate on one split and run a held-out high-confidence safety test. (4) ease.ml/ci (arXiv 1903.00278) gives statistically rigorous CI test conditions for ML model updates, including sample-size estimates and adaptivity. (5-6) Online FDR (Ann. Stat. 2018) and alpha-investing (JRSS-B 2008) cover a countable stream of tests. The paper limits its novelty to 'composition and formalisation', but without these works it cannot show what the composition adds beyond them.
Searched the LaTeX source for six closely related prior works, then fetched each work's title and abstract from arXiv or Crossref to confirm it exists and to establish the overlap.
Table 2: EGE harmful 0/3,000 in all conditions; naive harmful 2,997/3,000 at b=0.25 else 0; naive power 100%; EGE power 52.6% / 76.2% / 65.7% at n=m=5,000 for b=0/0.10/0.25 and 100% at 20k/80k
Harmful-acceptance columns and the 100% power entries reproduce: EGE 0/3,000 in all 36 runs; naive 2,998/3,000 at b=0.25 (claimed 2,997; expected 3000(1-2^-10)=2,997.1) and 0 otherwise. The n=5,000 EGE power column does not: obtained 67.4/67.7/68.5% (R=2, j=candidate index; MC SE 0.4 pp) vs claimed 52.6/76.2/65.7%; other readings give 61.9-63.4% (R=3), 50.6-51.7% (R=2, per-test index), 45.6-46.3% (R=3, per-test index). In every reading the spread across b is at most 1.2 pp (normal approx 67.95/68.07/68.37%), because b cancels in expectation in L^R and only enters the variance slightly. The claimed 23.6 pp non-monotone swing (52.6 -> 76.2 -> 65.7) is not consistent with the stated design; no reading reaches 76.2%.
Re-implemented the Sec. 8.1 DGP exactly (binomial sampling of {-1,+1} and {-2,+2} means, seed 20261112) under 4 readings of the unstated details: R in {2,3} and per-candidate vs per-test indexing of j; plus a normal-approximation analytic power.
The evaluator-calibrated LCB L^R = L^E - U^b (eqs.14-16), using n operational-evaluator observations plus m candidate-specific calibration observations W = D^E - D^R, is the paper's mechanism for reference-relative evidence; Table 4 sizes n and m (implicit premise: calibrating a cheaper evaluator is a sensible route to reference-relative evidence)
The reference-only radius is at most 0.494x the EGE radius at every grid point (analytically h^b alone = 2*sqrt(2 ln(1/c)/m) > sqrt(2 ln(1/(2c))/m) for any n, even n -> infinity). In the Table 4 setting the reference-only gate needs m = 3,674 / 7,358 / 11,042 reference-scored instances at j = 1/10/100, vs. EGE m = 67,651 / 126,597 / 185,543 reference-scored instances (16.8-18.4x more) plus n = 16,913-46,386 evaluator runs. In the Table 2 design at 5,000 instances the reference-only gate accepts 100.00% of beneficial candidates with 0/3,000 harmful campaigns, vs. about 67-68% for EGE. Under the paper's range-based (Hoeffding) bounds, the evaluator calibration adds cost without any statistical gain. The paper does not state an efficiency claim outright, but it never compares against the reference-only alternative.
Each W requires reference scores of candidate and comparator on the calibration instance, so the m calibration instances already give m paired D^R. Compared the EGE radius h^E+h^b with a reference-only Hoeffding radius sqrt(2 ln(1/(e+c))/m) on the same m instances: deterministic grid (1,470 points over n, m, j, R), sample sizes in the Table 4 setting, and a reference-only gate in the Table 2 design (n=m=5,000, R=2).
Theorem 1: with allocations (17), Pr{L^R_{j,r} <= Delta^R_{j,r} for all j, r} >= 1 - alpha under adaptive candidate generation; Corollary 1: FWER of false statistical acceptance <= alpha
In 5 settings, the simultaneous-coverage failure rate was 0.00026-0.0207 and the false-acceptance FWER was 0-0.0205 (SE <= 0.0003), all far below alpha = 0.3-0.9. No counterexample was found. The proof (per-(j,r) Hoeffding, then the deterministic inclusion, then a countable union bound) is correct. Both Hoeffding and the union bound are conservative, so this is a falsification test only.
Monte Carlo of an adaptive adversarial candidate stream (effect and evaluator bias chosen from the previous L^R), with worst-case two-point distributions, small n and m, large alpha (0.3-0.9), J=50, R in {1,2}, and 200,000 campaigns per setting. The proof itself was also read step by step.
e=c=3alpha/(pi^2 j^2 R); evaluation and calibration allocations each sum to alpha/2, total alpha
Symbolic sum of each family = alpha/2, total = alpha exactly; numerical partial sum to j=1e6 at alpha=0.05 is 0.04999997.
sympy symbolic summation and mpmath partial sum
Hoeffding radii sqrt(2 ln(1/e)/n) for [-1,1] observations (eq.14) and sqrt(8 ln(1/c)/m) for [-2,2] observations (eq.15)
Symbolic solutions equal the paper's radii exactly; maximal observed failure rate is 0.22x nominal (never exceeds nominal).
sympy solve of exp(-2nu^2/w^2)=a for w=2,4; Monte Carlo coverage for two-point distributions (27 settings x 2 bounds, 400k reps)
Section 5.4: on the event {dbar >= mu - h^E, wbar - b <= h^b}, L^R >= Delta - h^E - 2h^b (first display); 'consequently' L^R >= Delta - 2h^E - 2h^b; if 2h^E + 2h^b <= g the test passes with probability >= 1 - e - c
The minimum of L^R on the event is Delta - 2h^E - 2h^b (attained at the boundary), so the first display is false. Example: mu=0.35, b=0.10, h^E=0.03, h^b=0.02 gives L^R=0.150 < 0.180 = Delta - h^E - 2h^b. The second display is correct, and so is the power conclusion: the simulated pass probability at n=16,913 and m=67,651 is 1.00000, above 1-e-c=0.98987. 'Consequently' is a non sequitur because the second bound is weaker than the first. This error does not change eqs.(20)-(21).
Symbolic minimum of L^R over the event using sympy, a numeric counterexample, and a Monte Carlo of the pass probability at the minimal (n,m) from eqs.(20)-(21) (alpha=0.05, R=3, j=1, g=0.10).
Eqs.(20)-(21) are sufficient for 2h^E + 2h^b <= g; the evaluation bound is 'four times the fixed-radius requirement in (24)'
At n=(20), 2h^E = lambdag, and at m=(21), 2h^b = (1-lambda)g, so the sum is exactly g. The 'four times' statement holds only when (24) is read with h_E = lambdag (ratio 4). For the radius that (20) actually delivers, h_E = lambdag/2, the ratio is 1. The sentence is correct but potentially confusing (minor clarity issue).
Substituted (20)-(21) into the radii with sympy; computed the ratio of (20) to (24) under two readings of h_E.
3000/3000 campaigns with at least one harmful acceptance for both R=2 and R=3 (per-candidate acceptance 0.947 / 0.932; mean L^R 0.059-0.070 > delta=0.05).
Re-simulated the stated design with seed 20261112 for R in {2,3}
Formalise the reject outcome with an upper confidence bound and state the candidate-level acceptance bound 1−∑(e+c).
Replace App. E with a numerical worked example, and remove the revision artefacts in the Table 4 caption and Sec. 8.3.
Add even a small real-agent case study to show that the paired, fresh-sample audit design can be carried out.