A useful, physically grounded benchmark whose ranking machinery reproduces exactly from the printed tables, but the yield numbers in Table 4 do not follow the paper's own definition, two run HRMC arms are missing from the results, and the data-scaling and 'diffraction within MD variability' conclusions go beyond the evidence.
Soundness
2/4
Presentation
2/4
Contribution
3/4
Confidence
3/5
✓ 14 confirmed✕ 5 discrepancy○ 1 not checkable
Summary
The paper introduces AmorphBench, a protocol for judging how well generative and structure-fitting methods sample the melt-quench ensemble of an amorphous system at a given density or composition. Five systems (a-C, a-Si, a-SiO2, CuZr, Zr–Ni–Al) and 14 conditions are generated with classical MD (50 structures per condition, split 35/5/10). Generated structures are scored on 21 metric rows in six families (short-range order, topology, diffraction, energetics, mechanics, phase-space coverage). Each row is normalised by the MD leave-one-out error, so a score of 1.0 means "as good as an independent MD sample".
Eight methods are compared: RMC, HRMC and CRN as structure-fitting baselines; GLASS, DM2, AMDEN, CDVAE and MatterGen as generative models, most with and without PDF guidance. GLASS-c ranks first overall (mean rank 2.00) and first in every system on average. CDVAE and DM2-c tie for second, and RMC/HRMC come last. The authors argue that structural metrics alone make the task look solved, while energetics, mechanics and phase-space coverage do not. They also argue that validity and quality decouple (CDVAE is 24–30% invalid), that the ranking is robust to dropping metric families and to more reference or training data, and that GLASS's validation loss follows a power law in data size, so the models are "data-limited".
Strengths
Broad, physically grounded metric suite
Sec. 2.2; Tables 1–2
The 21 rows go well beyond structural fingerprints. They include per-atom energy and force distributions under the reference potential, bulk/shear/Young moduli, yield and ultimate tensile strength, relaxation distance and QUESTS phase-space overlap. Structural agreement alone would hide many failure modes, as the CuZr energetics in Table 2 show (no method is within MD error on energy; the best is 4.0×). The family count adds up: 5 + 4 + 2 + 2 + 6 + 2 = 21.
Interpretable MD noise-floor normalisation and no cherry-picking of samples
Sec. 2.2 'Scoring and validity'; Sec. 3.4
Normalising every row by MD leave-one-out variability gives a common '×MD' unit across very different observables. Methods are scored on their first ten structures in filename order, invalid ones included. This stops methods with a high rejection rate from looking better than they are, and the paper explicitly keeps yield and quality as separate claims.
Ranking machinery is internally consistent
Tables 1–4, 11–17, 25
Recomputing from the printed tables reproduces all 14 Overall values of Tables 1 and 2 exactly as row medians, and all 14 of Table 13. Mean-rank sums are correct in 17 tables. All eight Table 3 mean ranks agree within rounding (e.g. GLASS-c 1.980 vs 2.00). All 69 validity counts agree, and all 13 family-ablation τ values agree to two decimals (checks 01–04, 08).
Headline ranking is robust and not driven by guidance with the scoring potential
Sec. 3.3; App. E.8, Table 25; Tables 11, 13, 24
With any one metric family removed, GLASS-c stays first (min τ = 0.857, Table 25). The NCBS settings give τ = 1.00 for all 21 pairs (Table 24). An obvious concern is that GLASS-c uses energy guidance with the same potential used for scoring on a-C and SiO, but this does not explain the lead. GLASS-u has energy error than GLASS-c in both systems (a-C 8.2 vs 9.1; SiO 1.1 vs 4.4). Fully unguided GLASS-u also ranks ahead of every non-GLASS arm in 4 of 5 systems (check 19).
Weaknesses
Table 4 'rate' is not the yield the paper defines; cost figures do not follow
major · Sec. 3.4; Table 4; Table 17; App. C.9–C.10, Table 9
Sec. 3.4 defines yield as the fraction of draws both delivered at the requested condition and valid. Table 4's 'Drawn' column, however, counts only density-accepted draws for the filtered models. Under the stated definition, MatterGen-c's yield is 104/734 = 14.2%, not the 100% printed. AMDEN-c's yield is at most 103/330 = 31.2% (printed 76%), and at Zr–Ni–Al 1:1:3 AMDEN-c delivers 6/200 = 3% (Table 17: 6/6). The cost claims inherit the problem. 108 GPU-h of MatterGen-c generation over 104 accepted structures is about 62 min per structure, and per-draw medians divided by the 14.2% acceptance give 38–92 min, so the lower end of the stated '9 to 94 GPU-min' cannot be reproduced. 'CDVAE costs 1.4× more' is relative to CDVAE's own per-draw cost; per valid structure it is about 3.2× GLASS-c's slowest per-draw time. These numbers feed the paper's conclusion about generative sampling versus MD cost. Fix: report the yield as defined (raw draws in the denominator) per condition, and derive the costs from it (check 05).
Data-scaling conclusion overstated
major · Abstract; Sec. 3.5, Fig. 2; Sec. 4 Conclusions; App. E.7.4, Table 24
The abstract says performance improves with training data, and Sec. 3.5 and the Conclusions say the models are 'data-limited rather than capacity-limited'. The fit itself reproduces (slope −0.1439, R² 0.892, 28.2% per decade; check 06). But the local log-log slope shrinks from −0.270 to −0.108 to −0.060, and a saturating law with floor ≈ 0.79 fits the four means about 200× better (RSS 9.6e-5 vs 1.9e-2; indicative only). That pattern looks like diminishing returns toward a floor, not data limitation. On the benchmark metrics themselves, 10× more NCBS data barely moves GLASS-u (Overall 2.73 → 2.68), worsens CDVAE (2.53 → 4.13) and widens the CDVAE–GLASS-u rank gap (check 07). The only evidence of improvement is GLASS validation loss, measured at a fixed epoch count that confounds data size with optimizer steps (acknowledged). Fix: show benchmark scores against data size at a fixed number of optimizer steps, fit a saturating alternative, and reword the abstract and Conclusions.
HRMC liquid-start arms on a-Si and CuZr were run but not reported
Table 9's HRMC-L total of 52,147 core-h can only be reproduced (52,130, −0.03%) if it includes 30 liquid-start runs each on a-Si (504 h) and CuZr (410 h). The liquid arms in Table 6 (a-C, SiO, Zr–Ni–Al) account for only 24,710 core-h. These 60 structures (27,420 core-h, 53% of the HRMC-L cost) are absent from Table 6, from the 220-structure HRMC count in Tables 4 and 16, and from the full results in Tables 12 and 14 (check 11). Leaving out results of a baseline arm that was actually run makes it impossible to judge whether HRMC's last place reflects its best configuration. report these arms, or explain why they were excluded and correct Table 9.
Questions for the authors
Were HRMC liquid-start runs performed on a-Si and CuZr (Table 9 costs imply 30 structures each)? If so, what did they score, and why are they missing from Table 6 and Tables 12/14? Better HRMC numbers would change the baseline comparison.
Using the Sec. 3.4 definition (raw draws in the denominator), what are the per-condition yields of MatterGen-c and AMDEN-c? How was the lower bound of '9 to 94 GPU-min' per accepted MatterGen structure obtained?
Were test structures used at any point to select MatterGen-c guidance settings for a-C, a-Si and silica (App. C.1), or only validation references (A.7, D.1, D.4)?
Does GLASS still rank first if it is trained per condition on 35 structures on a-C, a-Si, CuZr and Zr–Ni–Al, as DM2 and CDVAE are? Does DM2-c close the gap when trained to convergence?
On NCBS, how do the benchmark scores (not validation loss) of GLASS change with 30/100/300/1000 training structures at a fixed number of optimizer steps? Does a saturating fit describe Fig. 2 better than the power law?
How large are the low-q truncation artefacts in the finite-cluster Debye XRD/ND, compared with a periodic calculation on a few MD structures? Do they affect the diffraction rows' ability to separate methods?
What does the ranking look like with equal weight per metric family instead of per row?
Verification
Only the PDF was available, so all checks are recomputations and internal-consistency tests on the printed numbers. Tables were parsed directly from the extracted text rather than transcribed by hand. Of 20 checks, 14 confirmed, 5 found discrepancies and 1 was not checkable. The core ranking machinery holds: Overall = median of rows, Table 3 mean ranks, rank sums in 17 tables, all 69 validity counts, family-ablation and NCBS τ values, Fig. 20 summaries, guidance effects, AMDEN capacities and budget arithmetic. A supplementary check shows that GLASS-c's lead does not come from energy guidance with the scoring potential. The discrepancies are: the Table 4 yield/cost figures do not follow the paper's own yield definition (05); unreported HRMC liquid-start arms behind the Table 9 total (11); text, figure and conclusion statements that disagree with the tables, including 'diffraction within MD variability' (13); the asterisk rule (14); and contradictory statements on test-set use (16). The power-law fit (06) reproduces, but the data saturate, which weakens the 'data-limited' reading. 70 of 71 references resolve.
○Not checkableReproducibility Statement (p. 11); App. B ('Every per-system constant is specified in the scoring code')
References
71 references checked
Malik et al. MADE: Benchmark environments for closed-loop materials discovery. ICML 2026.
Could not be located on Crossref (best match an unrelated review) or by arXiv title search; no DOI/arXiv ID given. Existence and venue unverified; cited only as an example of materials benchmarks (Sec. 1), so not load-bearing.
Chiang et al. MLIP Arena ... NeurIPS 38, 2026.
Crossref record (doi 10.52202/085713-4410) dates the NeurIPS 38 proceedings paper to 2025; the year 2026 in the citation appears to be wrong (minor).
Kai Yang and Daniel Schwalbe-Koda. A Generative Diffusion Model for Amorphous Materials. npj Computational Materials 12(1):29, 2026.
Resolves correctly (DM2), but Crossref gives publication year 2025 (online) against the cited 2026 volume year; minor.
Jiawei Guo and Daniel Schwalbe-Koda. Generative Inversion of Spectroscopic Data for Amorphous Structure Elucidation. arXiv:2603.23210, 2026.
Exists and its abstract matches the GLASS description (score-based prior with differentiable spectral/PDF guidance). It is load-bearing: GLASS's training defaults and guidance hyperparameters (App. C.5, D.2) are taken from it without re-tuning, and it is an unrefereed 2026 preprint. Not a citation error, but the source of the winning method's tuned settings is not peer reviewed.
Suggestions
Recompute Table 4 with the yield as defined in Sec. 3.4 (raw draws in the denominator), per condition, and derive all per-structure costs in Sec. 3.4 and App. C.10 from it.
Report the HRMC liquid-start a-Si and CuZr arms in Table 6 and Tables 12/14, or remove them from the Table 9 totals and explain why.
Reword the data-scaling claims in the abstract, Sec. 3.5 and Conclusions. Add benchmark-score-vs-data curves at fixed optimizer steps, and compare a saturating fit with the power law.
Replace 'diffraction within MD variability' in the Conclusions with a per-family, per-system statement that matches Tables 11–15.
Add a matched-budget control: GLASS trained per condition, and DM2 trained to convergence. Also either use the same kind of guidance target for all methods or justify the difference.
Delete or correct the last sentence of App. C.1 so that all appendices agree on how test structures were used.
Fix the cross-references: Fig. 13 / App. E.1 should cite Table 12; App. E.3 should say that main tables show single conditions; correct the Sec. 3.3 statement about CRN and AMDEN-c on SiO2.
State the asterisk rule as actually applied (relative to MD's own row value), and fix the two inconsistent cells.
Add a family-equal-weight ranking and bootstrap confidence intervals on mean ranks obtained by resampling structures.
Make the scoring package, reference datasets and generated structures available to reviewers (e.g. an anonymised archive), since they are the core contribution of a benchmark paper.
Scope of this review
Only the PDF was available. No LaTeX source, code, scoring package, datasets, checkpoints or generated structures were provided, although the Reproducibility Statement mentions supplementary material. No metric was recomputed from atomic structures, no model or MD simulation was rerun, and the physical adequacy of the reference potentials was not tested. All verification is recomputation and cross-checking of numbers printed in the paper's tables, figures and text. References were checked against Crossref and arXiv.
RMC is run for 72 h with documented χ² schedules (Table 5). HRMC is run in several arms with convergence traces (Figs. 3–6), and CRN is built with WWW + Keating relaxation. The appendices openly list the paper's own limitations, including DM2's probable under-training (C.6.1), CDVAE's checkpoint at a transient validation minimum (C.7.1) and the MatterGen scratch-training failure (C.8.1).
Validity separated from quality, with exact bookkeeping
Sec. 3.1, 3.4; Tables 16–17; App. C.7.2
Tables 16–17 break down validity failures by gate and condition. They show that CDVAE has good conditional quality but 24% (covalent) and 30% (metallic) invalid draws, mostly foreign elements (15 + 21 = 36 of 140). This is a concrete illustration of why crystal-style validity metrics do not carry over to amorphous matter.
2
Fix:
'Leading models reproduce diffraction within MD variability' is not supported
major · Sec. 4 Conclusions; Tables 11–15 (XRD, ND rows)
The Conclusions say structural agreement alone would declare the problem solved: leading models reproduce 'coordination, packing, rings, and diffraction within the MD variability'. In the full tables, GLASS-c's XRD/ND errors are ≤ 1.0×MD in only 2 of 10 system cells (a-C only), reaching 2.5× on Zr–Ni–Al. Across all structural rows, GLASS-c is within MD variability in only 16 of 40 cells (check 13). This statement frames the paper's central message, so it should be stated per family and per system as the tables actually show.
Training and tuning budgets are not matched across methods
GLASS, the winner, is trained per system on pooled conditions (105–140 structures), with defaults and guidance settings taken from its own preprint without a sweep. DM2 and CDVAE are trained per condition on 35 structures, and DM2 is stopped at about 27k effective updates with its loss still falling (C.6.1). Guidance targets also differ: the training-mean PDF for GLASS and DM2, but a single validation structure for MatterGen-c and AMDEN-c (A.7, C.9, D.1). Check 19 rules out the energy guidance as the source of GLASS's lead. Unguided GLASS-u also leads on silica, where GLASS trains on 35 structures like the others (mean rank 3.4 vs CDVAE 4.2). Pooled training remains an uncontrolled advantage on the other four systems, and DM2-c beats GLASS-c at Cu50Zr50 (1.8 vs 2.3). Fix: add a per-condition GLASS arm and a matched training budget for DM2, or state clearly that the comparison is between methods 'as recommended' rather than at matched effort.
Contradictory statements about use of test structures
minor · App. C.1 (last sentence); App. A.7, D.1, D.4
App. C.1 ends: 'No method was trained on the test structures, although MatterGen-c's guidance settings for a-C, a-Si, and silica were selected using them (Appendix A.7).' A.7, D.1 and D.4 instead say these settings were chosen on validation references only, and that a test-referenced pilot was discarded (check 16). For a benchmark paper, train/test hygiene must be stated without ambiguity. The impact on the headline ranking is small because MatterGen-c is not a leading method.
Text and figure references do not match the tables
minor · App. E.1, E.3, Fig. 13; Sec. 3.3; Tables 1–3, 12, 14
(i) Fig. 13B reproduces the system-averaged Table 12 Overall row in 8/8 methods, but App. E.1 cites Table 1, which matches in only 1/8 (CRN 7.2 vs 2.8; RMC 8.9 vs 14). (ii) App. E.3 says a cell is 'the same number in the main and full tables', but 156/168 cells differ between Tables 1 and 12, and 115/126 between Tables 2 and 14, because the main tables show single conditions. (iii) Sec. 3.3 says CRN and AMDEN-c are tied for a-Si and SiO2, but on SiO2 Table 3 gives 4.1 vs 5.5. (iv) 'First in every system' holds only for system averages (Cu50Zr50, Table 2). Checks 02, 13.
Significance markers do not follow the stated caption rule
minor · Table 1 caption; Tables 11–15 captions
The captions say asterisks mark cells below one minus MD's bootstrap band. Read literally, 36 unstarred cells qualify, mostly CN-outlier and ring-outlier rows where MD's own value is 0.0–0.5 (e.g. 10 SiO2 ring-outlier cells at 0.0 vs threshold 0.88). A rule relative to MD's own row value fits all but 2 cells (check 14). The caption should describe the rule actually used.
Equal row weighting over-counts mechanics
minor · Sec. 2.2; App. E.8, Fig. 20, Table 25
Every row carries equal weight, but the rows are strongly correlated. Shear and Young errors have ρ = 0.99, and the 21 rows behave like about 2.9 independent dimensions (participation ratio from Fig. 20). As a result mechanics gets 6/21 = 29% of the weight, against 10% each for diffraction, energetics and phase space (check 09). The family ablation shows the top of the ranking is robust, but CRN's place depends on mechanics. Reporting a family-equal-weight ranking would make this explicit.
Small samples give unstable medians for some methods
minor · Sec. 3.3, Sec. 4 Limitations; Tables 1, 11
With n = 10 per condition, 28 cells (2.1%) have bootstrap SE larger than the value. Thirteen of these are CDVAE cells, mostly on a-C (Table 11: energy 7.6 ± 1050, g(r) 3.0 ± 211), and HRMC's bulk modulus is 40 ± 206 (Table 1). No GLASS-c cell is affected (check 18). CDVAE's 'statistically tied' second place (2.88 ± 0.11) therefore rests partly on poorly determined medians. Reporting rank uncertainty from resampling structures would make the tie statement testable.
Reference ensemble and diffraction proxy limit what the scores mean
minor · Sec. 2.1–2.2; App. B; Sec. 4
Every score measures agreement with one classical potential per system, e.g. Tersoff (1989) for a-C, a potential with known limitations for sp²/sp³ bonding. Energy and force rows are evaluated with that same potential. XRD/ND are computed with the Debye equation on finite clusters without periodic images, which is prone to low-q truncation artefacts. The authors acknowledge the first point (Sec. 4), but neither choice is validated against experimental data or periodic calculations.
No artefacts available for verification
minor · Reproducibility Statement (p. 11); App. B
The Reproducibility Statement says an anonymised package is provided as supplementary material, but only the PDF was available for this review. Generated structures, datasets and checkpoints are promised upon acceptance. No metric could be recomputed from raw structures (check 20). For a benchmark paper the scoring code and reference data are the contribution, so they should be available to reviewers.
Guidance improves DM2 and AMDEN on all five systems and GLASS on four (a-C exception 1.93 vs 1.81); worsens MatterGen on four of five (silica 6.00 vs 3.48; a-Si exception 4.46 vs 4.74); Tables 19-23 cells equal Tables 11-15; relaxed-fraction statements
0 of 880 shared cells differ between Tables 19-23 and 11-15. Guided arm better on 4/5 systems for GLASS (a-C 1.9 vs 1.8), 5/5 for DM2 and AMDEN, 1/5 for MatterGen (a-Si 4.5 vs 4.7; silica 6.0 vs 3.5); the two-decimal values in the text round to the printed one-decimal cells. Table 18 confirms that guidance lowers the silica relaxed fraction for AMDEN, GLASS and DM2 but not MatterGen (4/10 both), and at a-C 1.9 for MatterGen and GLASS only.
Parsed Tables 19-23 and 11-15 from the paper text; compared all 880 shared cells; counted guided-vs-unguided mean-rank improvements per model; recomputed relaxed fractions from Table 18.
Compute-cost totals (Table 9): RMC 9,945, HRMC 22,922, HRMC-L 52,147, HRMC-w80 3,986, MD 172 core-h; HRMC arms as listed in Table 6 (220 structures; liquid starts only for a-C, SiO2, ZrNiAl)
Totals reproduce within 5% (RMC 71 h x 140 = 9,940 vs 9,945; HRMC 22,590 vs 22,922; w80 3,990 vs 3,986; MD 164 vs 172; CRN 24.8 vs 23). But the HRMC-L total of 52,147 core-h is only reproduced (52,130, -0.03%) if it includes 30 liquid-start runs each on a-Si (504 h) and CuZr (410 h); the Table 6 liquid arms (a-C, SiO2, ZrNiAl) give only 24,710 (-53%). These a-Si and CuZr liquid-start arms (60 structures, 27,420 core-h, 53% of the HRMC-L cost) are missing from Table 6, from the 220-structure HRMC (all arms) count in Tables 4 and 16, and from the full results Tables 12 and 14, so results of a run baseline arm are not reported.
Recomputed each total as per-structure median x number of structures (10 replicas per condition); recomputed the HRMC-L total with and without liquid-start runs on a-Si and CuZr.
AMDEN ghost-capacity ceilings (0.159938, 0.066042, 0.072767, 0.072835, 0.075408 atoms/A3) equal 1.10 x each system's maximum training number density
All five constants reproduced to within 2.5e-5 relative (C 0.159942 vs 0.159938; Si 0.066043 vs 0.066042; SiO2 0.072767; CuZr 0.072836 vs 0.072835; ZrNiAl 0.075408, set by the Zr1Ni3Al1 6.7 g/cm3 condition); remaining differences are within atomic-mass conventions. This also confirms that the densities and compositions in App. B match the per-system constants.
Converted the nominal densities and compositions of App. B to number densities with standard atomic masses; 1.10 x per-system maximum.
Narrative statements about Tables 1, 2, 11-15 and Figs. 13-14 (CN histogram vs mean CN; GLASS-c energy 3.7x -> 10x; AMDEN-c best moduli; E.1 0.3-1.0x rows; Fig. 13B values; E.3 identical cells in main and full tables; conclusion that leading models reproduce coordination, packing, rings and diffraction within MD variability)
Consistent: Fig. 14 histogram sums to 100.00% with mean CN 4.146 (4.15); GLASS-c energy 3.7 -> 10; in Table 2 AMDEN-c has the lowest bulk (1.8), shear (1.6) and Young (1.6) errors and ties GLASS-c on forces (1.5); no method is within MD error on energy (minimum 4.0); E.1 rows all lie in [0.3, 1.0]. Inconsistent: (i) Fig. 13B values match the system-averaged Table 12 Overall row in 8/8 methods but Table 1 (which E.1 cites) in only 1/8 (e.g. CRN 7.2 vs Table 1 2.8, RMC 8.9 vs 14). (ii) E.3 states a cell is the same number in the main and full tables, but 156 of 168 cells differ between Table 1 and Table 12 and 115 of 126 between Table 2 and Table 14 (main tables are single conditions, full tables are condition averages). (iii) The conclusion that leading models reproduce diffraction within MD variability: GLASS-c XRD/ND are <= 1.0x MD in only 2 of 10 system cells (a-C only; up to 2.5x on ZrNiAl), and 16 of 40 structural cells overall. (iv) At Cu50Zr50 (Table 2) DM2-c, not GLASS-c, has the best mean rank (1.8 vs 2.3); first in every system holds only for system averages (Table 3).
Parsed tables from the paper text and tested each statement programmatically.
Asterisks mark cells below one minus MD's bootstrap band
24 cells are starred. The literal caption rule (A) is violated by 36 cells, all unstarred cells that are definitely below 1 - SE_MD, almost all on the CN-outlier and ring-outlier rows where MD's own value is 0.0-0.5 rather than 1.0 (e.g. SiO2 ring outliers: 10 cells at 0.0 vs threshold 0.88). Reading (B), relative to MD's own row value, fits all but 2 cells: a-Si CN outliers CRN 0.0 (threshold 0.17; the same cell is starred in Table 1) and ZrNiAl rings MatterGen-c 0.6 (threshold 0.68). The caption therefore misdescribes the rule on outlier rows, and the markers are not applied fully consistently. This is minor and does not affect rankings.
For all 1,128 non-MD cells of Tables 11-15 with a printed value, tested whether the star pattern is consistent with (A) value < 1 - SE_MD (literal caption) or (B) value < MD row value - SE_MD, allowing for rounding of the printed digits; only definite violations counted.
Budget and data-weight arithmetic: Table 5 chi2/nq start values 0.029, 11.69, 73.1, 292 at sigma 1, 0.05, 0.02, 0.01; ~9 vs ~2 at sigma 0.01 vs 0.02; DM2 30,000 updates = 107 epochs, ~27,000 effective; GLASS splits 105/15, 35/5, 140/20; 25,000 and 3M environments; 294 metric-condition pairs
0.029/sigma^2 gives 11.6, 72.5, 290 vs 11.69, 73.1, 292 (within 1%); the 1/sigma^2 ratio of 4 is consistent with the approximate ~9 vs ~2; 30,000 x 16 / (35 x 128) = 107.1 epochs; 0.9 x 30,000 = 27,000; GLASS pooled splits 105/15, 35/5, 140/20 follow from 35/5 per condition; 50 x 500 = 25,000; 1,000 x 3,000 = 3M; 21 x 14 = 294.
Checked 1/sigma^2 scaling of chi2 from the sigma = 1 start value; recomputed epochs and split sizes and the counting statements.
Test structures were not used for model or guidance selection (MatterGen-c settings selected on validation references only)
App. C.1 states: No method was trained on the test structures, although MatterGen-c's guidance settings for a-C, a-Si, and silica were selected using them (Appendix A.7). App. A.7 states those settings were selected using the validation sweep; D.1 states all MatterGen settings were selected against validation references only and test-split structures were used solely for final scoring; D.4 says an earlier test-referenced pilot was discarded. The paper contradicts itself on whether test data informed MatterGen-c's hyperparameters. The likely explanation is a leftover sentence from an earlier draft, but it needs correcting. The impact on the headline ranking is limited because MatterGen-c is not a top method.
Regex search of the paper text for every statement on which split was used to select MatterGen-c guidance settings.
References exist and match their bibliographic details (71 entries)
70 of 71 references resolve to the cited work (47 by DOI, 13 by Crossref query, 11 via arXiv; the two textbooks Elliott 1990 and Frenkel & Smit 2002 are not indexed by Crossref but are well-known books). Not located: Malik et al. MADE (ICML 2026), which is not load-bearing. Minor year mismatches: Chiang et al. MLIP Arena (Crossref 2025 vs cited 2026) and Yang & Schwalbe-Koda DM2 (2025 online vs 2026 volume). The GLASS arXiv abstract matches the paper's description of the method. Details in work/ref_issues.json.
tools/check_refs.py on all 71 entries (Crossref by DOI or bibliographic query, arXiv by ID); flagged title, year and first-author mismatches; fetched arXiv abstracts of the load-bearing GLASS preprint (2603.23210) and AMShortcut (2603.29812). (output in work/refs_checked.json and work/verify/17_refs.log)
Supplementary: with n = 10 structures per condition, bootstrap errors carry the sampling uncertainty (Sec. 4); how stable are the printed medians?
The SEs are reported as stated, and the instability is localized: 28 cells (2.1%) have SE > value and 4 have SE > 10x value, all but 2 in non-GLASS columns. CDVAE accounts for 13 of the 28, mostly on a-C (Table 11: energy 7.6 ±1050, g(r) 3.0 ±211, CN outliers 0.3 ±7.6, ND 2.3 ±19), and HRMC bulk K 40 ±206 (Table 1). No GLASS-c cell has SE > value. CDVAE's a-C medians, which feed its tied-second standing, are therefore poorly determined, whereas GLASS-c's are not.
Counted cells whose printed bootstrap SE exceeds the cell value across all 1,349 non-MD cells with a positive value and an SE.
Supplementary fairness check: GLASS-c's lead does not come from energy guidance with the scoring potential (a-C, SiO2) or from pooled training
Energy guidance does not lower GLASS-c's energy error: GLASS-u is better on energy in both guided systems (a-C 8.2 vs 9.1; SiO2 1.1 vs 4.4) and on SiO2 forces (4.7 vs 6.0). Fully unguided GLASS-u ranks ahead of every non-GLASS arm in 4 of 5 systems (a-C 2.1 vs CDVAE 4.0; a-Si 3.0 vs 3.8; SiO2 3.4 vs 4.2, where GLASS also trains on only 35 structures like DM2/CDVAE; CuZr 3.5 vs 3.8) but not in ZrNiAl (4.8 vs DM2-c 4.6). The first place is therefore not explained by access to the scoring potential. Pooled training (105-140 vs 35 structures) remains a possible advantage except on silica.
Compared GLASS-c with the unguided GLASS-u (same checkpoint) on the energy and force rows where Tersoff guidance is applied, and GLASS-u's mean rank with the best non-GLASS arm in each full table.
The AmorphBench package, scoring code, models, generated structures and datasets reproduce the reported tables (Reproducibility Statement)
No code, data, checkpoints or generated structures were available; the paper says they will be released upon acceptance. No metric value could be recomputed from raw structures. Checking would need the scoring package and the generated structures for at least one condition (e.g. a-Si 2.3 for Table 1). All other checks are internal-consistency recomputations from printed numbers.
Looked for released artifacts in the review materials (only the PDF was supplied; no code URL, source or supplementary archive).
Overall ×MD is the median over a method's 21 metric rows (Tables 1, 2, 11-15)
All 14 Overall values of Tables 1 and 2 are reproduced exactly as medians of the printed rows (e.g. Table 1 GLASS-c 1.1, CDVAE 1.0, RMC 14; Table 2 GLASS-c 1.5, DM2-c 1.6). Table 13 (silica, a single condition) matches exactly for all 14 columns. For the condition-averaged Tables 11, 12, 14, 15 the median of averaged rows differs from the printed value by >15% in 17 of 52 cells (e.g. a-C DM2-u 9.4 vs 5.8), as expected if Overall is averaged per-condition medians; this is consistent with, but not a test of, the caption.
Parsed every metric row of Tables 1, 2, 11-15 from the paper text and took the median over the rows each method carries (fail cells excluded); compared with the printed Overall (×MD).
Cross-system mean ranks (Table 3): GLASS-c 2.00, CDVAE 2.88, DM2-c 2.91, MatterGen-c 4.0, CRN 4.8, AMDEN-c 4.9, RMC 5.7, HRMC 6.6; mean ×MD row; GLASS-c first in every system; CRN and AMDEN-c tied on a-Si and SiO2
All eight mean ranks are reproduced within rounding (e.g. GLASS-c 1.980 vs 2.00, CDVAE 2.880 vs 2.88, DM2-c 2.920 vs 2.91, MatterGen-c 3.940 vs 4.0/3.96). GLASS-c is first in all five per-system rows. Mean ×MD row matches to within 4% (CDVAE 1.64 vs 1.7; HRMC 12.7 vs 13 excludes the CuZr w80 arm, 15.3 if included). Normalising by the number of competitors swaps only the tied CDVAE/DM2-c pair. One textual statement does not hold per system: Sec. 3.3 says CRN and AMDEN-c are tied for a-Si and SiO2, but on SiO2 Table 3 gives CRN 4.1 vs AMDEN-c 5.5 (gap 1.4); they are tied on a-Si (5.5 vs 5.4) and in the cross-system mean (4.80 vs 4.87).
Averaged the per-system Table 3 rows over the systems each method covers and compared with the printed mean-rank row and Table 25 (within the ±0.05 rounding envelope); averaged Overall ×MD of Tables 11-15; recomputed the order with a scale-free normalised rank r/(k+1).
Mean ranks in every table are proper average places (sum to k(k+1)/2 per condition, accounting for arms missing at some conditions)
All 17 tables or table rows agree within rounding: e.g. Table 1 35.9 vs 36, Table 11 (a-C, MatterGen arms at 2/3 and 1/3 conditions) 70.7 vs 70.77, Table 12 76.0 vs 76.0, Table 3 a-C (MatterGen-c missing at C 2.9) 26.6 vs 26.7, Table 22 35.8 vs 36.0. The ranking machinery is internally consistent and the presence pattern in Table 18 is consistent with it.
Summed the printed mean ranks of each table and compared with the closed-form expectation derived from the per-condition presence pattern (Table 18, App. A.3/A.7); tolerance 0.05 per column for one-decimal rounding.
Validity and draw accounting: Table 4 rates, Table 16 gate failures, Table 17 per-condition counts, CDVAE 24% (covalent) and 30% (metallic) failures with 15 foreign + 2 overlaps, MatterGen 104/101 accepted in 13/11 conditions, filled 9 of 14, 5 of 14 below ten
69 of 69 comparisons agree exactly, e.g. CDVAE 205/280 = 73%, DM2-u 140/250 = 56%, AMDEN-c 103/136 = 76%; AMDEN-c overlaps 10+8+5+10 = 33 and AMDEN-u 39 (Table 16); CDVAE foreign 7+6+2 = 15 covalent and 10+11 = 21 metallic (36 total); 17/70 = 24% covalent, 21/70 = 30% metallic; MatterGen-c 104 accepted over 13 conditions with 9 filled; MatterGen-u 101 over 11 conditions with 5 of 14 below ten. The paper's validity bookkeeping is internally consistent.
Recomputed column sums and rates of Table 17 against its total row and Table 4; Table 16 arithmetic; AMDEN overlap failures from Table 17; CDVAE foreign counts parsed from Tables 11-15; MatterGen accepted counts and condition coverage from Table 18; relaxed-n totals of Tables 11 and 13 against Table 18.
Yield is the fraction of draws both delivered at the requested condition and valid (Sec. 3.4), reported in Table 4 (MatterGen-c 100%, AMDEN-c 76%, AMDEN-u 72%)
Table 4 Drawn counts only density-accepted draws for the density-filtered models (AMDEN-c Drawn 136 = 13x10 + 6). Under the Sec. 3.4 definition, MatterGen-c yield is 104/734 = 14.2% (Table 4: 100%) and AMDEN-c yield is at most 103/330 = 31.2% (Table 4: 76%); at ZrNiAl 1:1:3 AMDEN-c delivers 6/200 = 3% (Table 17: 6/6 = 100%). Cost: 108 GPU-h of MatterGen-c generation / 104 accepted = 62 min per accepted structure (per draw 8.8 min); per-draw medians divided by the overall 14.2% acceptance give 38-92 min, so the lower end of the stated 9-94 min range is not reproducible from reported numbers. The CDVAE 1.4x factor (1/0.73 = 1.37) is relative to its own per-draw cost; per valid structure CDVAE costs about 122 s, 3.2x GLASS-c's slowest per-draw time.
Computed yield under the paper's own definition from the raw-draw counts given in the text (104 of 734 MatterGen-c draws; AMDEN-c 6 of 200 draws at ZrNiAl 1:1:3 plus at least 10 draws at each other condition); recomputed cost-per-usable-structure figures from Table 9.
GLASS validation loss falls 1.36 -> 0.81 (30 -> 1000 structures) following a power law with exponent -0.144 (R2 = 0.89), about 28% per decade; models remain data-limited rather than capacity-limited
Slope -0.1439 (claimed -0.144), R2 0.892 (0.89), 28.2% per decade (about 28%): the reported fit is reproduced. However the local log-log slope shrinks from -0.270 (30->100) to -0.108 (100->300) to -0.060 (300->1000), and a saturating law with asymptote c = 0.79 has residual sum of squares 9.6e-5 against 1.9e-2 for the power law (3 parameters on 4 points, so indicative only). The data show diminishing returns approaching a floor near 0.8, which does not support the stated reading that the models are data-limited rather than capacity-limited; with a fixed epoch budget, larger sets also get more optimizer steps (acknowledged in the paper).
Log-log OLS on the four plotted means (1.3619, 0.9837, 0.8733, 0.8124); per-decade reduction; local slopes; comparison with a saturating law a N^-b + c (numpy/scipy).
Neither 6-10x more reference structures nor 10x more training data reorders the methods: Kendall tau = 1.00 for every pair of NCBS settings; max rank shift 0.10 (10->60 refs) and 0.12 (10->100 refs)
All 21 pairwise tau = 1.00; max shift 0.10 in-distribution and 0.12 held-out, exactly as claimed; rank sums 9.99-10.01; Fig. 19 labels equal Table 24. Context for the abstract's statement that performance improves with training data: on the benchmark metrics, 10x more data changes GLASS-u Overall x MD by only -1.8% (2.73 -> 2.68), worsens CDVAE by +63% (2.53 -> 4.13) and widens the CDVAE-GLASS-u rank gap from 0.10 to 0.61; DM2-u (-12%) and AMDEN-u (-6%) improve but remain at about 25x MD. The improvement with data is therefore shown only by GLASS validation loss (check 06), not by the benchmark scores.
Kendall tau (scipy) over all 21 pairs of Table 24 rows; maximal rank differences between reference-count settings; rank sums; comparison of Fig. 19 labels with Table 24; relative changes of the E.7.4 Overall x MD values.
Metric-family ablation: removing any family keeps GLASS-c first with tau >= 0.86; printed tau values; diffraction alone puts CRN last, mechanics alone fourth, energetics alone MatterGen-c level with DM2-c, phase space alone GLASS-c third
All 13 tau values reproduced to two decimals (e.g. without SRO 0.857 vs 0.86, diffraction only 0.571 vs 0.57, phase space only 0.714 vs 0.71); GLASS-c is first in all six leave-one-family-out rows (minimum tau 0.857); the only swaps are CDVAE/DM2-c and CRN/AMDEN-c; diffraction alone puts CRN 8th of 8, mechanics alone 4th; energetics alone gives MatterGen-c 3.27 vs DM2-c 3.38; phase space alone puts GLASS-c 3rd behind DM2-c (2.22) and CDVAE (2.23).
Kendall tau-b (scipy) of each Table 25 row against the All-families row; checked each textual statement against the row orders.
Row rank correlations: shear vs Young 0.99, XRD vs ND 0.87, mean 0.61 within families and 0.51 between, CN-outlier and mean-CN rows correlate with no other row above 0.68
Within-family mean 0.611 (34 pairs; claimed 0.61), between-family mean 0.510 (176 pairs; 0.51), shear/Young 0.99, XRD/ND 0.87; the maximum for CN outliers is 0.56 and for mean CN 0.68 (with rings), equal to the stated bound, not above it. Context for W6: the 21 rows behave like about 2.9 independent dimensions (participation ratio), and equal row weighting gives mechanics 6/21 = 29% of the weight versus 10% each for diffraction, energetics and phase space, with shear and Young nearly duplicated.
Parsed all 210 printed Spearman values of Fig. 20 from the paper text, assigned rows to the six families of Sec. 2.2, recomputed the summary statistics; computed the eigenvalue participation ratio and the family weights implied by equal row weighting (numpy).