Summary
The paper studies diplomatic transcription of handwritten Brazilian Portuguese essays: copying what the student wrote, including misspellings, line breaks, struck-out words and insertions. It extends the BRESSAY dataset into a benchmark that adds an error-preservation score (on dictionary-absent words), an invented-error rate, edit-markup precision/recall and line-structure accuracy to CER, with paired page-level bootstrap intervals. 22 open-weight baselines are evaluated (16 general VLMs, 5 OCR VLMs, the HTR-Flor line recogniser). The best zero-shot system, Qwen3-VL 235B-A22B, reaches 5.6% CER, and every VLM replaces 39–78% of likely misspellings with dictionary words.
The main contribution is Escriba-OCR-1B, LightOnOCR-3-1B fully fine-tuned (vision encoder included) for 85 minutes on the 647 training pages. It reaches 2.06% CER (2.7× lower than the best baseline, Δ −3.54 [−4.19, −2.94]), reproduces markup and line structure, and under a reconstruction of the ICDAR 2024 competition metric reaches 2.14% CER, which the paper places below the best published page-level results (2.24–2.43%). Quantised to 4 bits it runs on a CPU at about 53 s/page.
The analysis includes error decomposition, per-page behaviour, negative results for remedies against normalisation, ablations, a 40-letter out-of-domain test with WiSE-FT weight interpolation, and a teacher's review of 96 apparent corrections that attributes 45% of the judgeable ones to errors in the BRESSAY ground truth. All raw outputs, per-page scores and review verdicts are released.
Strengths
Headline results reproduce independently from released raw outputs
Table 3, Table 4, Table 5, Table 11, Table 12; Data and Code Availability
Rescoring the released predictions against BRESSAY ground truth downloaded from Zenodo with an independently written scorer gives Escriba 2.063 / 2.133 / 1.629 / 5.885 (CER / CER_case / CER_text / WER) against the paper's 2.06 / 2.13 / 1.63 / 5.9, and Qwen3-VL 235B 5.604 against 5.60 (check 01). All 18 bootstrap point estimates of Table 4 (check 02), all 188 cells of Tables 3/5 (check 03), all Table 11 BRESSAY cells (check 11), all Table 1 counts (check 14) and the seed table (check 06) match. Few applied OCR papers can be audited this thoroughly.
Benchmark measures faithfulness, not only accuracy
Sec. 4 (Handling of student errors; Markup and structure); Sec. 8.3; Figure 3a
Pairing the preservation score with an invented-error rate (§4) avoids the trap the paper itself demonstrates: HTR-Flor 'preserves' 24.6% of misspellings only because it misreads 53% of them and invents errors on 23.7% (check 03). Markup precision is reported next to recall for the empty-content type, and line structure is scored separately. The cross-system finding that all 21 zero-shot VLMs normalise 39.1–78.0% of likely misspellings is reproduced exactly.