Retain the useful mouse immunogenicity findings, but correct the primary-series comparison, substantiate or narrow the protection-ranking claim, and resolve the structural and statistical reporting gaps.
Soundness
2/4
Presentation
2/4
Contribution
2/4
Confidence
4/5
✓ 8 confirmed✕ 3 discrepancy◐ 4 inconclusive○ 1 not checkable
Summary
The paper characterizes XFG-matched mRNA vaccines in full-length spike (mRNA-1273.262) and linked RBD–NTD (mRNA-1283.262) formats, comparing them with LP.8.1-matched vaccines. It combines sequence surveillance and structural context with expression assays and mouse primary-series and preimmune-booster studies. Serum binding and pseudovirus neutralization are measured against contemporary JN.1-family variants and divergent BA.3.2.2.
The printed summaries support detectable cross-neutralization and higher post-booster XFG point estimates in both formats. They do not establish statistical superiority or human protection. One primary-series comparison contradicts the blanket within-two-fold statement, the computational claim of greatest population protection lacks the cited supplement and candidate-ranking outputs, and the stated cryo-EM symmetry conflicts with a uniquely single-RBD-up reconstruction. These issues warrant major revision rather than dismissal of the observed immunogenicity.
Strengths
Coherent comparison across formats and immune histories
Results lines 136–205; Figures 2–4
Figures 2–4 compare XFG with LP.8.1 within both full-spike and RBD–NTD designs and include naïve and previously immunized mice. This separates antigen-update comparisons from construct format and tests more than vaccine-matched neutralization; it is a useful preclinical contribution, although not a human-effectiveness study.
Central booster arithmetic is internally consistent
All eight printed post-booster XFG/LP.8.1 neutralization ratios exceed 1, ranging from 1.108732 to 6.780388 with ±0.5 integer-GMT rounding propagated. The claimed greater-than-two-fold binding advantage is reproduced as 156543/69483 = 2.252968 and 107428/50050 = 2.146414. All sixteen printed neutralization fold-rise labels also agree within ±0.05 plus propagated GMT rounding. This supports descriptive consistency, not comparative significance (checks 02, 04, 05).
Figures 3D/E and 4D/E; Results lines 167–168; Discussion lines 225–229
The inclusion of BA.3.2.2 extends the assay panel beyond JN.1-family targets. Printed XFG-vaccine BA.3.2.2 GMTs of 248 and 539 after primary immunization and 2641 and 3902 after boosting exceed the digitized Figure 3D assay LOD estimate of 38.46 (log10 uncertainty ±0.09). This supports the restrained claim of some cross-neutralization, not equivalent breadth or protection (check 03).
Plots expose useful individual-level information
Figure 3E; Figures 3D/E and 4D/E captions, lines 176–179 and 202–205
Neutralization panels display individual animals, GMTs and 95% confidence intervals rather than bars alone. A resolvable Figure 3E BA.3.2.2 subset yielded digitized GMTs of 369.62 versus printed 380 and 523.67 versus printed 539, agreeing within log10 tolerance ±0.06; approximate log-scale t-intervals also agree with the drawn caps. This is a limited plot-consistency check, not validation of every interval (check 09).
Weaknesses
Primary-series within-two-fold claim has a verified exception
major · Results lines 166–167; Figure 3D/E, particularly the mRNA-1273 LP.8.1-target pair
Results describe primary neutralization as comparable “within 2-fold” across tested variants, but Figure 3D prints LP.8.1-target GMTs of 33088 for the LP.8.1 vaccine and 14553 for the XFG vaccine. Their ratio is 2.2736205593; propagating ±0.5 rounding gives 2.2735080908–2.2737330356, entirely above 2. Seven of eight comparisons meet the stated threshold. This directly invalidates a main descriptive comparison as universally worded and contributes to the reduced overall score, but does not show vaccine failure or a statistically significant difference. Correct the statement to identify the exception and report all target-specific ratios (check 01).
Greatest-population-protection prediction is not substantiated
major · Results lines 105–108 and Figure S1 citation; Discussion lines 218–219; reference 18
Discussion calls XFG the candidate predicted to provide the “greatest protection to the population,” but the supplied PDF lacks the cited Figure S1, candidate-ranking outputs, uncertainty and population assumptions. Check 16 retrieved reference 18 passages reporting immune-escape scores against an LP.8.1-based vaccine—2.62 for XFG, 1.17 for NB.1.8.1 and 4.58 for BA.3.2.2/RE.2.2—not an explicit ranking of protection provided by alternative XFG-based vaccines. Experiments compare XFG with LP.8.1, not every plausible candidate. The prediction remains unverified, not disproved. Supply the actual ranking analysis and missing supplement or narrow the conclusion to measured preclinical immunogenicity (checks 10, 16).
Comparative inference and experimental independence are underreported
major · Results lines 137–146 and 187–193; Figures 2–4; Methods lines 322–396
Higher post-booster GMTs are reproducible as point estimates, but no between-group effect-ratio confidence intervals, hypothesis-testing plan, multiplicity procedure or equivalence margin is reported. For BA.3.2.2 in mRNA-1273, printed GMTs 2641 versus 2382 yield only 1.108732-fold (rounding bounds 1.108290–1.109175), so the word “higher” must remain descriptive. Exact group sizes, allocation/randomization, blinding, exclusions, biological versus technical replication, CI construction and LOD handling are insufficiently specified. Expression-plot similarity likewise cannot establish formal equivalence. Supply animal-level and replicate-level data with these methods, and distinguish descriptive ordering, equivalence, superiority and clinical protection. No human study is required if the claims are appropriately limited (checks 02, 08, 09, 13).
Questions for the authors
Can the authors provide Figure S1, the quantitative XFG-versus-alternative vaccine ranking, its population-immunity assumptions and uncertainty supporting Discussion lines 218–219?
For Figure 1E, was the one-up map actually refined in C1 or with focused/asymmetric processing, and where can the maps, coordinates and validation reports be inspected?
Can the authors release animal-level titers with pre/post identifiers, assay-replicate information, exact group sizes and exclusions, LOD substitution rules, and the procedure used to calculate the displayed confidence intervals?
Does Methods lines 350–351 mean 40 mice per cohort or across both cohorts, and how were animals assigned to groups and samples blinded?
Verification
Sixteen scripted checks were completed in the preceding verification step: eight confirmed narrow claims, three found discrepancies, four were inconclusive, and one was not checkable. The core evidence consists of arithmetic on independently transcribed GMT labels, selected figure digitization, a symmetry demonstration, methods cross-checks and public-reference lookups—not reruns of original experiments. Booster ordering, binding ratios, fold-rise labels and detectable BA.3.2.2 responses are supported at that scope. The primary within-two-fold exception affects a main descriptive result; the C3/single-up incompatibility affects structural reporting; omission of NB.1.8.1 from Methods is minor. Reference 9 also has a confirmed chronology error within the otherwise inconclusive bibliography check. Missing modeling outputs prevent verification of the strongest protection-ranking claim. These limitations and discrepancies justify major revision and overall 4/10, without negating observed immunogenicity or implying fabrication.
8Confirmed
3Discrepancy
4Inconclusive
1Not checkable
✕DiscrepancyResults lines 166–167; Figure 3D/E, PDF p.9
[9] FDA 2025–2026 formula; bibliography lines 433–436
Confirmed internal date-order issue: paper states publication August 12, 2025 and access May 22, 2025, which is 82 days earlier. Check16 script/log prints both dates and difference. This is a minor bibliographic chronology problem, not evidence that the recommendation was false. The cited URL returned HTTP404; access failure is not proof of a nonexistent source.
[18] Nasir et al., 10.1128/jvi.00225-26; Results105–108 and Discussion218–219
DOI/title/year match. Retrieved full-text passages describe risk of XFG, NB.1.8.1 and BA.3.2.2/RE.2.2 against an LP.8.1-based vaccine (scores 2.62,1.17,4.58), supporting the modeling framework and antigenic-grouping context. They do not provide an explicit XFG-vaccine-versus-alternative ranking of population protection in the retrieved evidence. Figure S1/model outputs are absent from the supplied paper, so the specific greatest-protection prediction remains unverified, not disproved. See check10 and check16.
[16] Jule et al., 10.1093/ve/veag011 and [17] Wu et al., 10.1016/s1473-3099(26)00349-x; Introduction65–68
Both DOIs match their cited titles/years. Reference16 abstract supports divergent BA.3.2 evolution, including 39 spike mutations relative to BA.3; full-text retrieval timed out. Reference17 title addresses neutralization by young-child plasma, which alone is not epidemiologic pediatric enrichment; its full content was not retrieved. The age-enrichment citation support could not be established from the accessible material. Do not call this a proven miscitation or nonexistent reference.
[23] Carabelli et al., 10.1038/s41579-022-00841-7; Discussion235–239
Reference exists and its abstract supports general immune escape, recombination, and changing population immunity. It is a 2023 review, so it cannot supply BA.3.2.2-specific contemporary measurements; accessible abstract does not establish the manuscript's variant-specific substantial loss of pre-existing immunity. This is a limit on how specifically the source supports the statement, not a rejection of its general contextual relevance. Full text timed out.
[20] WHO May16,2026 statement; Introduction76–79
Primary page retrieved: WHO recommends monovalent LP.8.1 and permits other antigens such as XFG/NB.1.8.1 meeting stated response criteria. This supports the manuscript's 'allowing' wording, but must not be described in the review as WHO preferring XFG. EMA reference19 explicitly recommends XFG for 2026/2027.
[13] CDC and [21] FDA 2026–2027 formula
Suggestions
Revise Results lines 166–167 to report seven of eight primary neutralization comparisons within two-fold and explicitly identify the 33088-versus-14553 exception.
Provide Figure S1 and the candidate-ranking model outputs, or remove the greatest-population-protection claim in Discussion lines 218–219.
Release machine-readable animal-level titers and assay metadata for Figures 3–4; report prespecified log-scale group contrasts with uncertainty and any multiplicity handling, keeping paired fold-rise analyses distinct from between-group post-booster comparisons.
For Figure 2, specify biological/technical replicate structure and flow uncertainty; retain descriptive similarity unless an equivalence margin and appropriate analysis are supplied.
Correct or document the Figure 1E refinement symmetry and deposit maps, coordinates, FSC curves and validation reports.
Complete Methods with NB.1.8.1 construct details, exact animal totals/group sizes, allocation/blinding/exclusions, dilution/fit settings and LOD/censoring rules.
Release surveillance count tables and grouping scripts for Figure 1C and distinguish sequenced-sample fractions from infection prevalence.
Correct reference 9 dates and provide claim-specific support for pediatric enrichment and BA.3.2.2 immunity statements; preserve the distinction between EMA recommending XFG and WHO permitting XFG while recommending LP.8.1.
Ethics and integrity
All authors list Moderna affiliation and the paper discloses Moderna funding (title page, lines 4–11; acknowledgements line 407). IACUC approval is stated in Methods lines 352–358. These disclosed interests are not evidence of misconduct; a dedicated competing-interest statement would improve transparency. No reviewer-directed instruction attempts were identified in the supplied paper, and the checks establish no fabrication or raw-data manipulation. The numerical exception, symmetry incompatibility and bibliographic date error do not establish intent.
Scope of this review
Only the uploaded 22-page PDF and request metadata were supplied. No source, executable analysis pipeline, individual-animal titers or identifiers, flow files, mass-spectrometry data, GISAID metadata, structural maps/coordinates, or Figure S1 supplement was available. The independent scripts check printed summaries and selected figure coordinates, reporting consistency, elementary symmetry and reference support; they do not reproduce the original assays, fit every GMT/CI, audit maps, infer whole-genome ancestry or measure human protection. ±0.5 integer rounding and explicit digitization tolerances apply only to the quantities tested. Expression equivalence and full-panel individual-data validation remain inconclusive. All 24 references were screened; all 15 DOI entries matched titles/years, but content checks and nine institutional-source checks were incomplete. CDC access failed and FDA pages returned 404, leaving the historical US ~68% figure and exact FDA source unverified rather than disproved. EMA explicitly supports XFG for 2026/2027; the retrieved WHO source recommends LP.8.1 while permitting XFG/NB.1.8.1 meeting response criteria, consistent with the Introduction’s permissive wording. Confidence is high in the identified arithmetic/reporting issues, not in unexamined raw experiments or the protection-ranking prediction.
Reported C3 refinement is incompatible with a uniquely single-up state
major · Figure 1E; cryo-EM Methods lines 293–297
Methods say that both RBD-down and single-RBD-up final reconstructions used C3 symmetry. The exact occupancy demonstration in check 11 takes a one-up state (1,0,0) to (1/3,1/3,1/3) under C3 averaging: a strict C3 map cannot uniquely localize one up RBD. This verifies an incompatibility in the reported procedure, not a defect in the actual unprovided maps. Explain any C1 or focused refinement or correct the symmetry statement, and provide deposition identifiers, map resolution, FSC and map-to-model validation before the Figure 1E structural result can be assessed. This issue is secondary to the immunogenicity contribution.
A tested pseudovirus is absent from the construction methods
minor · Methods lines 350–351 and 379–380; Figures 3D/E and 4D/E
Figures 3 and 4 contain four neutralization targets, including NB.1.8.1, whereas Methods list only LP.8.1, XFG and BA.3.2.2 spike genes. Check 13 confirms this reporting omission, not that an assay was not performed. Add NB.1.8.1 construct sequence/accession and preparation details, and explicitly state group sizes and whether “two cohorts consisting of 40 animals” means 40 total or per cohort; overlapping plot points do not resolve the animal total.
Surveillance plot is not independently reproducible or population-representative
minor · Results lines 100–104; Figure 1C; Methods lines 246–275
Check 14 reproduces only the displayed “>70%” XFG peak: approximately 0.7387 in October 2025 with absolute digitization tolerance ±0.011. The manuscript uses sequenced-sample fractions, not representative global infection prevalence; sequence accessions, monthly denominators and lineage-grouping code are unavailable, and May 2026 is partial. Label the quantity explicitly as the proportion of submitted sequences, give monthly counts and grouping rules, and discuss geographic sampling and reporting lag. This is not a verified error in the underlying counts.
Bibliographic chronology and claim-specific support need repair
minor · Reference 9, lines 433–436; Introduction lines 65–68 and references 16–17; Discussion lines 235–239 and reference 23
Reference 9 states publication August 12, 2025 but access May 22, 2025; check 16 computes access 82 days before publication. Correct the dates. In addition, accessible evidence did not establish epidemiologic pediatric enrichment from references 16–17, and the general 2023 review in reference 23 does not itself supply contemporary BA.3.2.2-specific measurements. Cite direct evidence or qualify these statements. DOI metadata match and inaccessible full text are not evidence of nonexistent sources or proven miscitation.
Computational risk assessment supports broad XFG coverage and the assertion that XFG was predicted to provide the greatest population protection.
Only PDF and request metadata supplied; Figure S1 is cited once but missing, as are model code/scores and rankings. Reference 18 resolves correctly; its abstract describes quantitative immune-escape grouping and XBB.1.5/JN.1/LP.8.1 selection exercises, not an explicit XFG population-protection ranking. Abstract access cannot exclude relevant full-text content. Numerical reproduction requires S1/model outputs. Follow-up check16 retrieved reference18 full text: LP.8.1-vaccine escape scores 2.62 (XFG), 1.17 (NB.1.8.1), 4.58 (BA.3.2.2/RE.2.2), not an explicit XFG-vaccine population-protection ranking; see reference_passages.json.
Check 10: Results 105–108 / Discussion 218–219, Figure S1, ref18.
Deps stdlib; inventory supplied artifacts and retrieve published Crossref metadata.
Generic User-Agent; bibliographic data only. No large downloads.
The reported single-RBD-up structure is compatible with the stated final C3-symmetric reconstruction procedure.
Exact single-up occupancy (1,0,0) has C3 invariance residual 1; enforced C3 averaging yields (1/3,1/3,1/3), residual 0, unlike a uniquely localized up RBD. All-down control invariant. Thus Figure 1E single-up description and Methods 294–296 strict C3 final reconstruction are incompatible as written. No deposition identifiers or matching EMDB query result retrieved. This establishes a reporting/method compatibility concern only, NOT invalidity of actual maps; C1/focused refinement or wording correction could resolve it.
Check 11: Figure 1E / Methods 294–296 strict C3 single-up compatibility.
Stdlib; exact rational occupancy example. Tests mathematics, not actual maps.
XFG is consistent with a mosaic of LP.8.1.2 and LF.7 RBD haplotypes separated between residues 444 and 445.
All 32 displayed sites are compatible with LF.7 on left of 444/445 and LP.8.1.2 on right (zero categorical tolerance). Informative sites: 444 matches LF.7; 445,487,493 match LP.8.1.2; zero mosaic mismatches. Ref22 title resolves, no Crossref abstract. Confirms Figure 1B internal mosaic compatibility only, not independent exact-breakpoint or whole-genome ancestry inference.
Check 12: Figure 1B; Results 96–98, mosaic around 444/445.
Stdlib. Independently transcribed all 32 displayed positions from page6 crop.
Letters are categorical, tolerance zero. Sparse sites cannot locate exact breakpoint.
The experimental description is sufficient to account consistently for cohort sizes, doses, sampling times, and all four pseudovirus targets displayed.
Figures 3D/E and 4D/E have four targets; Methods 379–380 list three and omit NB.1.8.1, a definite reporting omission (minor, not evidence the assay was not performed). Schemes agree approximately with timepoints: 50 vs ~49 days, 15 vs ~14 days. Eight resolved dots/group in Figure 3E would imply 40 per cohort with a shared PBS group if all n=8, but wording 40 across two cohorts is ambiguous; no definitive animal-total contradiction asserted.
XFG reached >70% global sequence prevalence before declining in 2026, consistent with the plotted monthly proportions.
Figure 1C digitized peak ~0.7387 in October 2025 (absolute tolerance ±0.011; conservative lower 0.7277 > paper >70%) and decline to ~0.1952 by partial May2026. Selected category sums ~0.337,1.011,0.922,0.835 (conservative ±0.088); groups are nonexhaustive, no sum-to-one requirement justified. Underlying counts/GISAID grouping and population representativeness not checkable.
Check 14: Figure1C / Results100–104 / Methods266–275. Stdlib.
Coordinates on enlarged Figure1 crop: full page resize 1546x2000,
crop(650,180,1370,640), resize 2x -> 1440x920.
Calibration y758=0, y342=0.7, monthly x=260+35*m (Oct2023 m0).
Marker localization ±3 px; y calibration conservative ±6 px -> ±0.011.
No GISAID metadata/grouping scripts supplied; only plotted sequence proportions checked.
Primary institutional sources substantiate the stated XFG strain recommendation for 2026/2027 and the ~68% US sequencing proportion for April 12–May 9, 2026.
EMA reference19 directly supports XFG for 2026/2027 (29 May2026), citing 74% global sequenced infections in October2025. WHO reference20 recommends LP.8.1 while allowing XFG/NB.1.8.1 meeting response criteria; this supports permissive wording at Introduction77 but NOT a uniform WHO XFG-preferred recommendation. CDC403 prevents checking ~68% for April12–May9; FDA404 is access failure, not evidence of a false recommendation. No US counts recomputed.
Check15: Introduction58–59,77–79; references13,19–21.
Stdlib; fetch only public cited primary URLs, generic UA, bounded reads.
Save compact relevant passages; dynamic pages cannot establish historical surveillance.
The bibliography identifies real, matching sources, and the BA.3.2 divergence/pediatric and recombination context is supported by the cited literature.
All 15 DOI titles/years match Crossref; nine institutional sources require direct lookup, not fuzzy matches. Ref16 abstract supports long-branch BA.3.2 divergence (39 spike changes vs BA.3) but does not establish pediatric enrichment. Ref17 and22 resolve correctly but full content unavailable. Ref23 abstract supports general immune escape/recombination, not BA.3.2.2-specific quantified loss. Ref18 full text retrieved: LP.8.1-based-vaccine escape scores XFG2.62, NB.1.8.1 1.17, BA.3.2.2/RE.2.2 4.58; no retrieved explicit greatest-population-protection ranking for an XFG vaccine. Ref9 dates differ by -82 days (access precedes stated publication), a confirmed minor chronology issue within this otherwise incomplete content check.
Check16: References1–24, especially16–18,22–23; lines433–436.
Stdlib. Generic UA; Crossref for titles/abstracts and Europe PMC for content.
Public bibliography only. No requester metadata. Bounded reads and timeout.
Run tools/check_refs.py work/references.json separately as prescribed.
Primary neutralization GMTs are within 2-fold for all matched comparisons.
Seven of eight comparisons satisfy <=2. Figure 3D LP.8.1 target: paper 33088 versus 14553; obtained ratio 2.2736205593 (rounding interval 2.2735080908–2.2737330356), exceeding claimed 2-fold. This is a descriptive wording exception, not a significance test or failure of immunogenicity.
Check 01: Results 166–167 / Figure 3D/E; claimed within 2-fold.
Deps: Python standard library only; no installation.
Figure labels independently read from PDF pp. 9 and 11 rendered at 2100/2400 pixels.
These scripts test printed summaries, not original measurements.
XFG boosters elicit higher post-boost neutralization GMTs than matched-format LP.8.1 boosters against every pseudovirus tested.
All eight XFG/LP.8.1 post-boost GMT ratios exceed 1 with ±0.5 rounding: range 1.108732–6.780388. BA.3.2.2 1273: paper 2641 versus 2382, obtained 1.108732 (bounds 1.108290–1.109175). Confirms point-estimate ordering only, not statistical superiority.
Check 02: Results 192–193 / Figure 4D/E; claimed higher XFG GMTs.
Deps: Python standard library only; no installation.
Figure labels independently read from PDF pp. 9 and 11 rendered at 2100/2400 pixels.
These scripts test printed summaries, not original measurements.
Both XFG vaccine formats produce detectable BA.3.2.2 cross-neutralization in primary and booster models.
Printed BA.3.2.2 GMTs are 248 and 539 (primary) and 2641 and 3902 (booster), all above digitized Figure 3D LOD estimate 38.46 (log10 uncertainty ±0.09; illustrative calibration). GMT/LOD ranges 6.45–101.46. This confirms descriptive assay detectability only; individual counts and clinical protection are unavailable.
Check 03: Figures 3D/E, 4D/E; detectable BA.3.2.2 cross-neutralization.
Deps: Python standard library only; no installation.
Figure labels independently read from PDF pp. 9 and 11 rendered at 2100/2400 pixels.
These scripts test printed summaries, not original measurements.
Booster-series binding titers are within 2-fold before boosting and more than 2-fold higher with XFG than LP.8.1 after boosting.
Figure 4B/C: paper d71 pairs 51053/31419 and 27538/29755 yield symmetric ratios 1.624908 and 1.080507 (<2). Paper d86 156543/69483 and 107428/50050 yield XFG/LP ratios 2.252968 and 2.146414 (>2); ±0.5 rounding does not change conclusions.
Check 04: Results 187–189 / Figure 4B/C; <=2 baseline, >2 post.
Deps: Python standard library only; no installation.
Figure labels independently read from PDF pp. 9 and 11 rendered at 2100/2400 pixels.
These scripts test printed summaries, not original measurements.
All sixteen fold changes printed above booster neutralization bars equal post-/pre-boost GMT ratios to the reported one-decimal precision.
All sixteen printed fold labels agree with post/pre GMT ratios to ±0.05, with propagated ±0.5 integer-label rounding. Largest point difference 0.04225 (paper 13.6, obtained 13.557752). Aggregate consistency does not verify animal-level pairing.
Check 05: Figure 4D/E sixteen printed one-decimal fold changes.
Deps: Python standard library only; no installation.
Figure labels independently read from PDF pp. 9 and 11 rendered at 2100/2400 pixels.
These scripts test printed summaries, not original measurements.
Pre-boost neutralization titers are similar (within 2-fold) across future LP.8.1 and XFG booster groups for each pseudovirus.
All eight d71 matched-format baseline symmetric ratios are <2, range 1.034202–1.684807; largest rounding upper bound 1.686330. Ratio-of-fold-rise sensitivity calculations are descriptive, not causal adjustments.
Check 06: Results 190–191 / Figure 4D/E baseline <=2.
Deps: Python standard library only; no installation.
Figure labels independently read from PDF pp. 9 and 11 rendered at 2100/2400 pixels.
These scripts test printed summaries, not original measurements.
Primary-series LP.8.1 and XFG vaccines produce binding GMTs within 2-fold in both formats.
All four primary-binding symmetric comparisons meet <=2: 1.295242, 1.464794, 1.355114, 1.370104. Paper GMTs and ±0.5-rounding upper bounds are printed in log. Confirms Wuhan S-2P binding summary arithmetic only.
Check 07: Results 160–164 / Figure 3B/C within 2-fold.
Deps: Python standard library only; no installation.
Figure labels independently read from PDF pp. 9 and 11 rendered at 2100/2400 pixels.
These scripts test printed summaries, not original measurements.
XFG antigen expression is similar to LP.8.1 within both mRNA designs by peptide abundance and near-overlapping cell-surface detection curves.
Digitized Figure 2A N=6 ratios give mean/SD 1.0081/0.2102 (1273) and 1.2013/0.1612 (1283), consistent with bar/error positions within 0.04. Approximate flow half-plateau concentrations 5.96 vs 5.65 ng (1273), 2.87 vs 2.00 ng (1283), plateaus ~98%; pixel uncertainty ±4. No equivalence margin, raw data, or flow uncertainty: descriptive similarity only.
Check 08: Figure 2A–C, Results 137–146. Stdlib only.
Method: manual coordinates from page7 rendered at 2100 pixels, cropped/rescaled
onto a 2000x581 viewing grid. All coordinates below are on that viewing grid.
Pixel uncertainty ±3 (MS), ±4 (flow). No statistical equivalence margin in paper.
Recreate view: pdftoppm -f 7 -l 7 -scale-to 2100 -png -singlefile inputs/paper.pdf /tmp/figure2
resize full page to 1546x2000; crop (210,1120,1380,1460); resize to 2000x581.
The displayed neutralization GMTs and 95% confidence intervals are consistent with the plotted individual-animal titers.
Resolved Figure 3E BA.3.2.2 sample: eight dots/group yield GMT 369.62 versus printed 380 and 523.67 versus 539, within digitization log10 tolerance ±0.06. Approximate t-CIs 229–597 and 242–1132 match digitized caps ~225–595 and 241–1140. Overlapping dots in other prespecified panels and unspecified CI formula prevent a complete validation.
Check 09: Figure 3E BA.3.2.2 individual dots and GMT/CIs.
Deps stdlib. Manual pixel centers from PDF p9: render -scale-to 2100,
resize to 1546x2000, crop(1090,1470,1250,1695), resize 2x.
Calibrate y=434 at 10^1 and y=30 at 10^4. Dot localization ±4px,
axis localization ±3px; conservative log10 error ±0.06.
Only this subset resolved reliably; other prespecified groups not fully recovered.
Access limitations only: CDC returned HTTP403 and FDA HTTP404. The historical US ~68% sequencing fraction for April12–May9,2026 and the exact FDA dated page could not be verified. These errors do not establish false claims or nonexistent publications.
[22] Guo et al., 10.1016/s1473-3099(25)00308-1