A valuable, internally consistent diagnostic of whether proxy-conditioned video models follow the simulated object state, but the released code contradicts the paper's class-agnostic/rigid-carry simulator and main configuration, the test set is filtered by SimPWM's own calibration, and no released artifact allows the headline percentages to be recomputed.
Soundness
2/4
Presentation
2/4
Contribution
3/4
Confidence
3/5
✓ 15 confirmed✕ 3 discrepancy◐ 1 inconclusive
Summary
SimPWM builds an explicit, perturbable proxy for action-conditioned robot video generation. From the first frame and a per-episode calibrated camera, the robot is represented by its 3D model and the objects the gripper may touch by class-agnostic 3D point sets lifted from metric depth, with an action snap that rescales each object so its depth matches the end effector at gripper closure. A rule-based simulator with no trained parameters (grasp, rigid carry Pt=QRt⊤+, release, gravity onto a height map) moves the points under the recorded actions, and a fine-tuned video model (MiniMax-H3, LTX-2.3 or Cosmos-Transfer 2.5) renders the proxy into realistic video.
Strengths
A real test of whether the video follows the proxy
Sec. 4.5, Table 5, Fig. 8, App. C.4 (Table C3)
Freezing the simulated objects while the arm moves as recorded (and the no-close and arm-offset perturbations) separates following the arm from following the object state, which proxy-conditioned world models usually take for granted without testing. The test reveals a clear qualitative difference between base models (H3-C rigid lifts 42 → 10% vs LTX-C 57 → 49%). The paired difference of drops is 22 pts [12, 31]. The method is cheap, model-agnostic and reusable by other groups.
Controlled proxy ablation that credits the simulator only with what it adds
Sec. 4.4, Table 4; App. C.2 (Table C1)
Table 4 keeps base model, data and training steps fixed and varies only the proxy, including no proxy, a robot-only render (the RoFacto-style interface) and a PointWorld-driven proxy. It shows honestly that the arm-tracking gain (robot IoU 0.34 → 0.77) comes from rendering the robot, and that the simulator's contribution is confined to object-state metrics (Miss −16.5 pts [8.3, 25.6]).
Reported numbers are internally consistent across tables and text
Tables 4, 5, C1, C3; Fig. 8; Sec. 4.3–4.5
Every percentage in Tables 4, 5, C1, C3, Fig. 8 and the LTX robot-only comparison reconstructs to a unique set of integer counts on n = 293/160/133/96/37, and these counts agree across tables. Every derived number in the text (Δ row, 14 of 24, 12.8/31.6/18.8 pts, 49/90 + 13/43 = 62) recomputes exactly (checks 01–04, 13). The McNemar test (21 vs 8, p = 0.024), the binomial/bootstrap intervals and the Cohen's κ values are reproducible or attainable (checks 05–07).
Unusually candid caveats and judge validation
Sec. 4.1 (Protocol and caveats); App. A (Evaluation caveats i–v); App. C.4
Weaknesses
Released code contradicts the 'class-agnostic, cloth carried rigidly' description
major · Sec. 1 (choice i, contribution ii); Sec. 4.4 (Deformable objects); Sec. 4.5; Abstract; simpwm/sim/engine.py, simpwm/config.py
The paper says the scene has "no categories" (Sec. 1, choice i; contribution ii) and that ropes and cloth are carried rigidly. This rigid carry is the stated explanation for most remaining H3-C lifts under freezing ("14 of 24 are cloth/rope", Abstract, Sec. 4.5). The released simulator, however, contains a category-dependent soft-object rule. Deformables named by Qwen3-VL-32B (keyword match on the VLM phrase) hang from the jaws or slide as a sheet, and soft_objects=True is set in both presets that config.py calls the configuration reported in the paper (check 10). The rule fires whenever runs/vlm_objects/<idx>.json exists, and the release does not show whether such files existed for the paper runs. If they did, the deformable rows of Table 5, the deformable IoU in Table 4 and the interpretation of the remaining lifts would all change. Fix: state explicitly whether the rule was active for any proxy used in training or evaluation, and either disable it in the paper presets or describe it and report results with and without it.
Main configuration cannot be reproduced from the release
major · Sec. 4.1 caveat (ii); App. A caveat (ii); Table A1; Table 3; simpwm/config.py, docs/configuration.md, scripts/eval/proxy_ablation.sh
According to the paper, SimPWM-H3-C, the Table 4 ablation models and Table 3's 69.5% use the later simulator version, which grasps only inside the jaw volume and segments parts. In the code, those features exist only in the droid_hires preset. That preset also silently changes the simulation resolution to 640×360, rescales k from 6 to 24 points, and uses a separate camera set in which 325 cameras differ. The paper mentions none of these changes. The repo documentation says the opposite of the paper: it says these options are off in the paper configuration, maps the tables to the droid preset, and its proxy_ablation.sh omits --hires (check 11). Following the documentation therefore reproduces the earlier-version numbers, not Table 3. In addition, the main-model weights () return HTTP 401, and the list of the 293 retained test episodes, the generated videos and the judge outputs are not released (checks 09, 18). None of the headline percentages can therefore be regenerated; only their internal consistency could be checked. align the paper and the documentation, state resolution, and camera set per model in Table A1, and release the 293-episode list, per-episode judge answers and the weights.
Questions for the authors
Did runs/vlm_objects/<idx>.json files (Qwen3-VL soft-object labels) exist for any episode when rendering the proxies used to train SimPWM-H3-C / LTX-2.3-C or to produce Tables 4 and 5? If so, which deformable episodes were draped rather than carried rigidly?
Which exact preset, simulation resolution, point threshold k and camera set (cameras vs cameras_hires) produced SimPWM-H3-C, the Table 4 ablation models and Table 3's 69.5%? The repo docs currently point to the droid preset.
How do SimPWM and the baselines compare in robot IoU and trajectory accuracy on the episodes removed by the calibration filter (IoU < 0.6), using logged cameras, and on a subset whose (lab, user, date) sessions do not appear in training?
If the uncertain judge sheets are counted as lifts and then as non-lifts, how much does the H3-C rigid frozen-object rate (10%) change? Does a second human rater on the frozen-object conditions reproduce κ = 0.91?
Does the miss-rate advantage of simulated objects over the robot-only proxy survive against the full RoFacto interface (end-effector and scene depth plus static RGB context)?
Which interval method (and how many bootstrap resamples) produced the binomial CIs, e.g. [45, 82] for 14/22?
Will the main-model weights (Luffuly/SimPWM-H3-C, currently HTTP 401), the list of the 293 retained test episodes and the per-episode judge answers be released?
Verification
We ran 19 scripted checks: 15 confirmed, 3 discrepancies, 1 inconclusive. No generated videos, judge outputs or per-episode metrics are released, and the 22–33B video models cannot be run without a GPU, so the headline results could not be recomputed. Instead we tested internal consistency, statistics, splits and code against paper. Every percentage in Tables 2–5, C1–C3 and Fig. 8 reconstructs to unique integer counts that agree across tables and text, and the McNemar, κ and CI values are reproducible. The released simulator behaves as Sec. 3.2 describes on synthetic scenes, with matching thresholds. The discrepancies concern the code and the configuration, not the arithmetic. The paper presets enable a VLM-based soft-object rule that contradicts the class-agnostic, rigid-carry description (check 10). The later-version simulator the paper attributes to its main model exists only in an undocumented hi-res preset, which the repo says was not used (check 11). One rounding slip was found (1.9 vs 1.82 pts; check 05). The splits confirm that the test set is pre-filtered by SimPWM's own calibration and largely shares sessions with training (check 09). The main weights are not publicly accessible (check 18).
15Confirmed
3Discrepancy
1Inconclusive
✓ConfirmedTable 4; Sec. 4.4; App. C.2; Abstract (54% -> 38%)
kim2026rofacto (Kim et al., Robot-factored world models via robot rendering, CoRL 2026; arXiv 2607.22535)
Cited in Sec. 4.4 as the source of the 'robot-only' proxy ('The robot-only row is the robot-render proxy of prior work'). According to its abstract, RoFacto conditions on the rendered robot together with paired end-effector and scene depth and camera-aware static RGB context. The paper's robot-only row (shaded robot without the scene, App. C.2) is therefore a reduced version of RoFacto's interface, and the comparison credits the simulator against a weaker baseline than RoFacto itself. The wording should say 'RoFacto-style' or add the depth/scene context.
23 bibliography entries without arXiv ID or DOI (e.g. guo2025ctrlworld, gao2026dreamdojo, huang2026pointworld, khazatsky2024droid, carion2025sam3, ravi2024sam2, bansal2025videophy2, quevedo2026worldgym, yu2025r2r2r)
Not a correctness problem: all were found on arXiv by exact title. Without identifiers, automatic lookup (Crossref) matched unrelated works. Adding arXiv IDs/DOIs would make the bibliography verifiable.
minimax2026h3 (MiniMax H3 blog post / Hugging Face / GitHub, July 2026)
The main base model is cited only through a blog post and model pages (all return HTTP 200). There is no technical report, so the Ref2VA pretraining that Sec. 4.5 invokes to explain why MiniMax-H3 follows the object state cannot be checked against a written description.
liao2026memorizon (Liao et al., arXiv 2610.00544)
Self-citation (shared first author), cited only in a generic list in Sec. 2. The compiled bibliography entry contains a BibTeX artefact ('2026\natexlaba').
Suggestions
Add a table that maps every reported row to base model, training set (3000 / 845), simulator version, preset, simulation resolution and camera set, and make the repo documentation use the paper's table numbering and model names.
Disable the VLM soft-object rule in the presets labelled as the paper configuration, or document it in Sec. 3.2 and report Table 5's deformable rows with and without it.
Release the 293-episode test list, per-episode metrics and judge answers, and make the SimPWM-H3-C weights public, so the grasp and lift percentages can be recomputed rather than only checked for consistency.
Report Table 2's arm metrics with out-of-window calibration and on the episodes removed by the IoU ≥ 0.6 filter, and add a session-disjoint test subset.
In the abstract, report right-object pick-ups and wrong-object pick-ups next to the miss reduction (54% → 38%).
Strengthen the frozen-object conclusion with a second human rater, bounds over uncertain sheets, and if possible a third base model with and without reference-to-video pretraining.
State the CI method throughout and prefer Wilson or Clopper–Pearson intervals for n ≤ 30.
Add arXiv IDs or DOIs to the 23 bibliography entries that lack them and fix the 'natexlaba' artefact.
Scope of this review
No GPU was available, so none of the video models (MiniMax-H3 33B, LTX-2.3 22B, Cosmos-Transfer 2.5) or baselines could be run. The paper's generated videos, Claude judge answers, per-episode metrics and the list of the 293 retained test episodes are not released, and the main-model weights return HTTP 401. All grasp, lift and video-quality numbers were therefore checked for internal consistency only. The code was inspected at commit 63ebd9d in a sparse checkout without the bulk camera resources and examples; the 500 test-candidate cameras were fetched separately. The simulator was exercised only on synthetic scenes with the droid preset, without the hi-res/jaw-inside rules and without VLM soft-object files.
On 293 DROID test episodes the paper reports that every SimPWM variant tracks the commanded arm better than end-to-end world models (robot IoU .754–.777 vs at most .690, Table 2), and that a robot-only proxy already achieves this (Table 4). Against that robot-only proxy, simulated objects reduce missed pick-ups from 54.1% to 37.6%. The paper's central diagnostic (Sec. 4.5, Table 5) freezes the simulated objects while the arm moves as recorded. With this perturbation MiniMax-H3 fine-tuned on simulation-consistent episodes (SimPWM-H3-C) mostly stops lifting rigid objects (42% → 10%), whereas LTX-2.3 mostly keeps lifting them (57% → 49%). The paper reads this as LTX-2.3 inferring grasps from arm motion. It also reports that training on inconsistent data weakens object following, and gives transfer results on WorldArena (bimanual) and GR1 (humanoid).
The paper frames itself as much as a diagnostic of proxy-conditioned world models as a new model, and it is explicit about many of its own caveats.
The paper itself discloses that Ctrl-World was trained on ≥234 of the 293 test episodes, that model rows mix two simulator versions, that calibration uses test-window frames (with a refit: proxy IoU 0.787 → 0.768), that the 8-frame perturbation judge confirms only 68% of lifts, and that FVD is biased. It also validates the VLM judge against human labels (44/46, κ = 0.91). Readers can therefore weigh the evidence themselves.
Simple, documented simulator that behaves as described
Sec. 3.2, App. A (Simulator); simpwm/sim/engine.py
The grasp/carry/release rules are stated precisely, and all thresholds in the released code match App. A (close 0.12, k = 6, 8.5 cm opening, empty ≥ 0.975, snap s∈[0.35,2.5]). Running the released RuleEngine on synthetic scenes reproduces the stated behaviour: rigid carry error 1.2e-9 m, fits-opening preference, 5 vs 6 point and 0.11 vs 0.13 closure thresholds, gravity release (checks 10, 19).
Returns an explicit state alongside the video
Abstract; Sec. 1 (contribution i); Sec. 5
Because SimPWM outputs the simulated object state together with the video, disagreement between the two is observable at inference time. This makes the model's failure modes auditable, which end-to-end video world models do not offer.
Luffuly/SimPWM-H3-C
Fix:
k
Test set is filtered by SimPWM's own calibration and is not session-disjoint
major · Sec. 3 (camera); Sec. 4.1 (Data); App. A (Camera calibration); Table 2
Test candidates are restricted to episodes on which SimPWM's per-episode camera fit reaches robot IoU ≥ 0.6. All 500 shipped test cameras satisfy this (min 0.600). The fit uses 20 frames, exactly 5 of them inside the evaluated 97-step window, in all 500 episodes (check 09). This selection favours SimPWM on exactly the metrics of the headline comparison (robot IoU, trajectory accuracy), and the paper only partially acknowledges it (caveat iii; refit 0.787 → 0.768). Moreover, 354 of the 500 candidates (105 of 171 test sessions) share a (lab, user, date) session with training episodes, and one candidate (41476) is in the validation split. "Unseen setups" therefore means a new camera pose or setup, often on the same day and in the same scene. Fix: report baseline and SimPWM metrics on the episodes removed by the filter (with logged cameras), use out-of-window calibration for the main table, and add a session-disjoint subset.
Object-state conclusions rest on small counts and a weakly validated VLM judge
major · Sec. 4.5; Table 5; App. C.4 (judge validation)
The headline rigid result for H3-C (42% → 10%) is 40 → 10 lifts out of 96 episodes (check 02). The 8-frame perturbation judge confirms only 68% of whole-clip lifts. Human validation is by one rater on 46 decided sheets; 14 of 60 were uncertain, including 5 of the 10 H3-C frozen-object sheets, which is the key condition (check 06). The explanation that MiniMax-H3 follows object state because of its Ref2VA pretraining rests on one model of each behaviour type, and MiniMax-H3 has no technical report against which to check it (ref issues). Fix: add a second human rater on the frozen-object conditions, report bounds that count uncertain sheets both ways, and either test a further base model or present the Ref2VA account as a hypothesis.
The gain from simulated objects is modest and the abstract framing overstates it
major · Abstract; Sec. 4.4; Table 4; App. C.2, Table C1
Against the robot-only proxy, the gain in right pick-ups is not significant (+7.5 pts [−0.8, 15.8]), and other-object pick-ups rise by +9.0 pts (Table 4, check 01). Within the stratum where the proxy grasps the right object, 10 of the 17 added lifts (59%) are of a wrong object; the text says "about half" (Table C1, check 04). Deformation IoU worsens (.533 → .507). The robot-only baseline is also weaker than the RoFacto interface it is said to reproduce: RoFacto additionally conditions on end-effector and scene depth and static RGB context (ref issues). The abstract's "cut missed pick-ups from 54% to 38%" is accurate but, without these qualifiers, reads as a larger benefit than the data support. Fix: report right-object pick-ups in the abstract alongside misses, and compare against a full RoFacto-style proxy.
Baseline comparison in Table 2 is confounded
minor · Sec. 4.1 (Protocol and caveats); Sec. 4.2; Table 2
Ctrl-World is trained on at least 234 of the 293 test episodes (80%; 72% of the perturbation set). SimPWM-H3-C is trained on an 845-episode consistent subset with the later simulator, whereas the other variants use all 3,000 episodes with the earlier one. The H3 FVD improvement 194.1 → 85.6 mixes fine-tuning with subset selection (checks 08, 16). The paper acknowledges these issues, and the arm-tracking gap is large enough that they are unlikely to reverse it. However, the margins on PSNR/LPIPS/FVD should not be read as a like-for-like comparison.
Cross-embodiment results are uncontrolled
minor · Sec. 4.2 (Other robots); App. E, Tables E1, E2
The WorldArena baselines were copied from the leaderboard, and SimPWM was trained on the benchmark paper's test episodes. SimPWM is 3rd of 19 in trajectory accuracy but 14th of 19 in image quality (check 14). The GR1 test windows come from sessions seen in training. These results show that the pipeline runs on other robots; they do not show that it generalises better.
Proxy is wrong in roughly 30% of episodes
minor · Sec. 4.3, Table 3; Sec. 5 (Limitations)
The proxy's grasp outcome agrees with the real video in only 69.5% of decidable episodes (191/275, check 05). The "explicit state" returned with the video is therefore wrong for nearly a third of episodes even under recorded actions, which limits its use as ground truth for downstream policy evaluation. The paper acknowledges this (Limitation 2), but the 30% error rate deserves weight in the claims about the state being a useful output.
Dense presentation and version bookkeeping
minor · Sec. 3.3; Sec. 4.1; Table A1; repo docs
The prose is heavily qualified and the paper spans many model variants (Table A1), two simulator versions and two training sets. Key definitions (the consistent subset, the judge protocols) appear only in the appendix. The repo also uses an older table numbering (repo Tables 1–4 = paper Tables 2–5/Fig. 8) and calls the 845-episode model SimPWM-H3 rather than SimPWM-H3-C. A single table mapping each reported row to model, data, simulator version and preset would remove most of the confusion.
Small numerical and reporting slips
minor · App. A (Evaluation); App. C.4; App. C.2; References
The w/o-snap drop is 5/275 = 1.82 pts, not the stated 1.9 (a difference of rounded values; check 05). The lower bound 45 of the 14/22 interval sits exactly on the discrete bootstrap boundary, and the CI method is never stated; Wilson/Clopper–Pearson give 41–43 (check 07). "About half" is 59% (check 04). One bibliography entry contains a BibTeX artefact ('natexlaba'), and 23 entries lack arXiv IDs or DOIs. None of these slips changes a conclusion.
Simulator is class-agnostic (no categories) and carries ropes and cloth rigidly; thresholds c>0.12, opening drop 0.12, k=6, jaw 8.5 cm, full closure >= 0.975, snap s in [0.35, 2.5]
All thresholds match the paper: close_thr 0.12, open_drop 0.12, min_pts 6, max_open_m 0.085, empty 0.975, ratio_range (0.35, 2.5); in droid_hires, k is rescaled to 24 points (same density at 640x360), which the paper does not mention. Mismatch: the code has a category-dependent soft-object rule. Deformables named by Qwen3-VL-32B (keyword match on the VLM phrase) hang from the jaws or slide as a sheet. soft_objects=True in both presets that config.py calls the configuration reported in the paper, and the rule fires whenever runs/vlm_objects/<idx>.json exists. The paper says the scene has no categories and that cloth and rope are carried rigidly. Whether VLM files existed for the paper runs cannot be determined from the release. If they did, the deformable rows of Table 5 and the interpretation of 14 of 24 remaining lifts as rigidly carried cloth/rope would need revisiting.
Parsed defaults and presets of the released code (commit 63ebd9d) with ast/regex: RuleEngine, refine.py, franka_robotiq.json, config.py, droid/run.py, sim/pipeline.py, perception/vlm_objects.py
SimPWM-H3-C, the ablation models (Table 4) and Table 3 Ours (full) 69.5% use the later simulator version (grasps only inside the jaw volume, segments parts); all-3000 models use the earlier version (74.2%)
The later-version features (jaw_inside, parts) exist only in the droid_hires preset, which also changes the simulation resolution to 640x360 and uses a different camera set (cameras_hires, 325 cameras differ). The paper mentions neither the resolution change nor the second camera set. The repo states the opposite of the paper: config.py says these options are off in the configuration reported in the paper. docs/configuration.md and train.md map Tables 1-4 to the droid preset with LTX-2.3 on 3000 episodes. scripts/eval/proxy_ablation.sh (repo Table 2 = paper Table 3) does not pass --hires. The repo docs follow an older table numbering (repo Table 1-4 = paper Tables 2, 3, 4, Fig. 8/Table 5) and call the 845-episode model SimPWM-H3 rather than SimPWM-H3-C. Following the released docs would reproduce the earlier-version numbers, not the 69.5% of Table 3. The scripts also compute a w/o SAM 3 proposals ablation row that is absent from paper Table 3.
Extracted preset definitions, preset-to-table mapping in docs, and reproduction-script flags from the released repo
LTX-2.3 token-level loss on moved objects 0.319/0.325/0.385/0.396 => arm motion accounts for 91% of the proxy gain
(0.385-0.325)/(0.385-0.319) = 0.909 (claimed 91%); rounding range [0.894, 0.924]. Measured on 30 training episodes at a single noise level (sigma=0.9), so it describes in-distribution behaviour only.
Recomputed (none-frozen)/(none-proxy) and its range under 3-decimal rounding
LTX-2.3 robot-only vs RGB proxy (full resolution): miss 12.8% vs 20.3% (7.5 pts), other object 23.3% vs 15.0% (+8.3), right 63.9% vs 64.7%, grasp agreement 72.7% vs 73.7%, FVD 80.7 vs 93.3 (-12.6)
Unique counts: RGB 17/31/85, robot only 27/20/86 (both sum to 133); Acc 216 and 213 of 293, implying 29 and 33 false pick-ups of 160. Miss reduction 7.52 (claimed 7.5), other-object increase 8.27 (claimed 8.3), FVD difference -12.6. The robot-only LTX model has better FVD (80.7 vs 93.3).
Integer numerators on 133/293; rows must sum to 133; recomputed differences and implied false pick-ups
WorldArena: SimPWM best on 3 of 10 ranked metrics and 3rd of 19 in trajectory accuracy after GE-Sim 2.0 and GigaWorld-1; GR1: robot IoU 0.861 vs 0.815, better PSNR/SSIM, worse LPIPS/FVD
19 models (18 baselines). SimPWM best on JEPA, Depth and Sem (3 of 10); trajectory rank 3 (0.5271 after 0.5863 and 0.5427); all bold marks correct; image-quality ranks 14/19 (Image) and 11/19 (Aesth). GR1 numbers match the claims. Baseline values were copied from the leaderboard and are not re-run; SimPWM was trained on the benchmark paper test episodes (acknowledged), so the comparison is not controlled.
Parsed Tables E1/E2 from the LaTeX appendix and ranked every column
Pairwise plausibility on 24 non-rigid episodes: the H3 ablation model and SimPWM-LTX-2.3 are preferred over their proxy, DreamDojo and Cosmos-Predict 2.5 and about tied with Ctrl-World
All rows sum to 24. Against proxy/DreamDojo/Cosmos-Predict: win rates 0.78-0.91, sign-test p <= 0.011. Against Ctrl-World: 10/4/10 (p=1.0) and 11/6/7 (p=0.48), consistent with about tied. With n=24 the test cannot exclude moderate differences, and the 40-episode win rates quoted in App. C.3 are not tabulated.
Bookkeeping: 97 steps @15 fps = 6.4 s, 158 frames @24 fps = 6.5 s; 8,000 vs 16,000 samples; 763 of 3,000 disagree (a quarter); arm offset 75 = 33+29+13
96/15 = 6.400 s; 157/24 = 6.54 s (rounds to 6.5); 250x32 = 8,000 = half of 1,000x16; 763/3000 = 25.4%; 33+29+13 = 75. Ctrl-World training overlap is 234/293 = 80% of the test episodes and 96/133 = 72% of the perturbation set.
Arithmetic
The 69 bibliography entries exist; load-bearing references (RoFacto, PointWorld, Ctrl-World, DreamDojo, Agentic Real2Sim, WorldArena, LTX-2, MiniMax-H3) say what the paper attributes to them
All 66 archival references resolve to the cited works. The 23 entries without IDs were found on arXiv by exact title, after Crossref matched unrelated works for them. The three non-archival sources (MiniMax-H3 blog, HF, GitHub) return HTTP 200. Abstracts agree with the attributions: Ctrl-World is trained on DROID; PointWorld forecasts 3D point flows from RGB-D and actions; WorldArena evaluated 14 models; Agentic Real2Sim uses VLM agents for real-to-sim. One nuance (see ref_issues): RoFacto conditions on rendered robot plus end-effector/scene depth and static RGB context, so the paper robot-only row (shaded robot without the scene) is a reduced version of the RoFacto interface, not that interface itself.
tools/check_refs.py (Crossref/arXiv), then arXiv title search for the 23 entries without IDs, arXiv abstracts of 7 load-bearing references, HTTP status of non-archival links
Released artifacts suffice to reproduce key results: main-model weights (README: Luffuly/SimPWM-H3-C on Hugging Face), the 293 retained test episodes, generated videos and judge outputs
The README badge and docs/inference.md point to Luffuly/SimPWM-H3-C. Its Hugging Face API returns 401 to unauthenticated requests, which is what private or nonexistent repos return. The MiniMax-H3 base model returns 200. The repo has no list of the 293 retained test episodes (only the 500 candidates), no generated videos, no Claude judge answers and no per-episode metric summaries. Every grasp/lift percentage and every metric can therefore only be checked for internal consistency, not recomputed. The weights may be published later or need access.
HTTP status of the advertised Hugging Face repo (unauthenticated); search of the repo tree (14,116 files) for test-episode lists, judge outputs and metric summaries
Simulator rules (Sec. 3.2, App. A): grasp when closing (c>0.12) with >= 6 points between the pads, prefer an object that fits the 8.5 cm opening, rigid carry P_t = Q R_t^T + o_t, release on a drop > 0.12 then gravity onto the height map, full closure (>= 0.975) holds nothing
A 4 cm cube is grasped on the first closing step, carried through a 20 cm lift, a 10 cm shift and a 90 deg yaw with max error 1.2e-9 m against the rigid-transform formula, then released and lands on the table (min z 0.0000, height kept 0.04). A 12 cm slab loses to a 3 cm cube (fits-opening preference). 5 points: no grasp; 6 points: grasp. Closure 0.11: no grasp; 0.13: grasp. Released when the closure drops 0.13 below its maximum but not at 0.11. A 0.98 plateau is flagged as empty; a 0.7 plateau is not. Two expectation errors in the first version of the test script (tolerance 1e-9, a 0.11 drop) were fixed; the code was not changed. Only the droid preset was tested, without the hires/jaw_inside rules and without the soft-object drape rule (no VLM file).
Ran the released RuleEngine (commit 63ebd9d, droid preset) on synthetic point-cloud scenes with a mock parallel-gripper embodiment and scripted closures and arm poses
Table 4 grasp columns and Delta row (RGB vs robot-only: Acc +2.4, False +1.9, Miss -16.5 [8.3, 25.6], Right +7.5; other object +9.0; 20 false and 25 wrong-object pick-ups)
Every row of Table 4 has a unique count solution satisfying Acc=(160-False)+Right (e.g. robot only 191/17/72/48, RGB 198/20/50/58). Recomputed Delta: +2.39, +1.88, -16.54, +7.52 (claimed +2.4, +1.9, -16.5, +7.5; tol 0.05); other object 13 -> 25 = +9.02 (claimed +9.0); 20 false and 25 wrong-object pick-ups match the text; agreement gains over no proxy 11.6-14.3 match. Implied discordant pairs (Miss ~30 vs 8, False ~10 vs 7) are feasible. Only internal consistency is verified; the judge outputs are not released.
Enumerated integer numerators for every displayed % (n=293/160/133), required Acc = (160-False)+Right, recomputed Delta and other-object rates from the counts, backed out discordant pairs implied by the paired CI widths
Table 5 frozen-object rates are computed from counts (96 rigid / 37 deformable); H3-C rigid 42->10 (Rel 75%), LTX-C 57->49 (15%); 14 of 24 remaining H3-C lifts deformable; paired drop difference 22 pts; robot-only 12.8 vs RGB 31.6 -> 18.8 pts; Cosmos drop 17 pts below H3-C; SimPWM-H3 +16/+17 pts vs H3-C
Each of the 7 models has exactly one count solution consistent with Table 5 and Table C3 (e.g. H3-C rigid 40/11/10, deformable 22/10/14; LTX-C 55/37/47 and 27/22/26). Derived: Rel 75.0 (claimed 75%), 14 of 24 and 10 of 21 (exact), paired drop difference 21.8 (claimed 22), 12.78/31.58/18.80 (claimed 12.8/31.6/18.8), Cosmos 17.29 (17), SimPWM-H3 vs H3-C 15.79/16.54 (16/17), H3-C vs ablation NC 7.52 (8). Ablation RGB rigid Fz 13% needs 12/96=12.5% rounded half-up. Note the rigid H3-C Rel of 75% rests on 40 -> 10 lifts. Judge outputs not released, so only consistency is verified.
Enumerated integer counts k/96 and k/37 for every Table 5 entry, required the Rel column and the independently printed 133-episode rates of Table C3 to match, then recomputed every derived number in the text
Fig. 8 and Table C3 perturbation rates agree with each other and with Table 5 counts; simulator lifts in 90/133; H3-C lifts in 54% of these and 30% of the other 43 (LTX-C 63% / 58%); numbers without the 6 dev-inspected episodes
All 9 Fig. 8 rows equal Table C3 (e.g. H3-C 47/16/18, LTX-C 62/44/55). 90/133 = 67.7% (proxy readout 68). The only split for H3-C is 49/90 + 13/43 = 62 = Table 5 total; LTX-C 57/90 + 25/43 = 82 = Table 5 total. The 127-episode numbers (46/16/18, 46/9/17, offset 33%) are attainable by removing 0-5 lifts among the 6 episodes.
Parsed the text layer of fig/counterfactual.pdf, compared with Table C3; split recorded-action lift counts into sim-lift/no-sim-lift pairs rounding to the stated % and checked they sum to the Table 5 totals; checked feasibility of the 127-episode rates
Table C1 grasp strata (Right 69 / Other 31 / None 22 + 11) are consistent with Table 4; RGB proxy adds +24.6 pts of lifts where the proxy grasps the right object and -4.5 where it grasps none; 14/8/2/1 of the 25 wrong-object pick-ups
Unique counts for every cell (e.g. Right stratum robot only 32/4/33, RGB 39/14/16). Lift gain 24.64 (claimed +24.6), None stratum -4.55 (claimed -4.5). Residuals for the 11 excluded episodes are non-negative and sum to 11 (robot only 4/0/7, RGB 5/1/5); wrong-object split 14/8/2 (+1) matches. Note: in the Right stratum, the +17 added lifts are 7 right-object and 10 wrong-object, so more than half (59%) of the added lifts are of another object; the text says about half.
Reconstructed integer counts per cell with rows summing to n, recomputed the lift differences, and checked the 11 residual episodes against Table 4 totals from check 01
Main statistics confirmed: every % maps to a unique k/275 (191, 204, 195, 152, 188, 186, 187, 220); 204-21+8 = 191; 275-204 = 71 rejections; (204+16)/275 = 80.00%; exact McNemar p = 0.0241 (claimed 0.024). Minor rounding discrepancy: w/o action snap is 186/275, so the drop is 5/275 = 1.82 points (rounds to 1.8), not the stated 1.9 (App. A Evaluation), which is the difference of the rounded values 69.5-67.6. Does not affect any conclusion.
Integer numerators k/275 for each percentage; arithmetic 204-21+8; exact and chi-square McNemar p-values
Judge vs human: 44 of 46 decided sheets agree (96%), Cohen kappa = 0.91; first pass 41 of 50, kappa = 0.65
44/46 = 95.7%; 39 tables give kappa rounding to 0.91 (max achievable 0.913, balanced yes/no marginals ~16-30 yes). 41/50: 20 tables give 0.65 (max achievable 0.651), so both values are attainable, at the upper end, implying roughly balanced yes/no labels. Underlying labels not released; note 14 of 60 sheets were uncertain and excluded, 5 of them among the 10 H3-C frozen-object sheets.
Enumerated all 2x2 confusion tables with the stated agreement and computed Cohen kappa
Binomial intervals: H3-C lifts in 49/90 = 54% [43, 64]; on the 22 None episodes H3-C misses 14 (64%, [45, 82]) and LTX-C 4 (18%, [5, 36])
49/90: Wilson [44.2, 64.3], CP [43.6, 65.0], bootstrap [44.4, 64.4] vs claimed [43, 64] (within 1.5 pts). 4/22: bootstrap [4.5, 36.4] matches [5, 36]. 14/22: our bootstrap gives [40.9, 81.8]; the claimed lower bound 45 (=10/22) arises because P(X<=9)=0.0251 sits on the 2.5% boundary, so a bootstrap with fewer resamples gives 45.5. Intervals are consistent within one grid step; the CI method is not stated in the paper, and with n=22 a Wilson/CP lower bound (41-43) is more conservative.
Wilson, Clopper-Pearson and percentile-bootstrap (seed 0, 100k) intervals; analysis of the discrete bootstrap grid j/n
Table 2: SimPWM robot IoU .754-.777 vs at most .690 end-to-end; Cosmos-Transfer nearly doubles Cosmos-Predict 2.5 robot IoU; H3 FVD 194.1 -> 85.6, robot IoU .718 -> .777; FVD differences -6.05 (vs LTX-2.3) and -20.3 (vs Ctrl-World); fine-tuned SimPWM rows best PSNR/LPIPS; bolds correct
All 7 bold marks are on the per-column best (ties bolded for LPIPS and Robot). Fine-tuned SimPWM robot IoU range 0.754-0.777; end-to-end max 0.690. Ratio 0.754/0.398 = 1.89. FVD H3-C minus LTX-2.3 from rounded table values = -6.10 vs reported paired difference -6.05 (consistent given 1-dp rounding); vs Ctrl-World -20.30 (claimed -20.3). Every fine-tuned SimPWM row beats every other row on PSNR and LPIPS. Note: the 194.1 -> 85.6 comparison mixes fine-tuning with the consistent-subset selection. Raw per-episode metrics are not released.
Parsed Table 2 from the LaTeX source and recomputed ranges, ratios, differences and per-column best
3,000 training episodes; 845-episode consistent subset of them; 500 test candidates from setups without training episodes; calibration on 20 frames, 5 inside the evaluated window; episodes with calibrated robot IoU < 0.6 removed before drawing test candidates
train 3000, test 500, train_h3 845 (subset of train), no train/test episode overlap. All 500 test cameras have iou_after >= 0.6 (min 0.600, median 0.843), consistent with the pre-filter. With --clip-frames 241 the code fits 20 frames, exactly 5 at steps <= 96 in all 500 episodes (with the default 97 it would be 12). Caveats the paper does not state: (a) 354 of 500 test candidates share a (lab, user, date) session with training episodes (105 of 171 test sessions), so the novelty is camera pose/setup rather than scene or day; (b) one test candidate (41476) is also in the 8-episode validation split used for training-time validation renders; (c) the list of the 293 retained test episodes is not shipped, so the 293/121 selection cannot be reproduced; (d) the IoU >= 0.6 filter selects episodes on which SimPWM own calibration works.
Loaded the repo splits (commit 63ebd9d) and the 500 shipped test cameras; recomputed fit-frame positions with the formula of simpwm/droid/episode_calib.py; tabulated iou_after; compared (lab, user, date) sessions between train and test