A clear idea with arithmetically consistent main tables, but small margins (often <0.15 DSC for Flumina-S), single-seed ablations whose reference row matches no reported model, an overstated significance claim and a mislabelled strongest CNN baseline leave the central empirical case only partly supported.
Soundness
2/4
Presentation
3/4
Contribution
3/4
Confidence
3/5
✓ 14 confirmed✕ 2 discrepancy◐ 1 inconclusive○ 1 not checkable
Summary
The paper argues that Transformer-based 3D segmenters face a representation–structure dilemma. U-shaped skip connections preserve fine structure but let the decoder bypass the Transformer. Skip-free ViTs such as Primus make the Transformer indispensable but lose structural detail. The proposed fix is to keep structure as state rather than skip.
Flumina, the proposed model, projects the four outputs of a residual CNN tokenizer (widths 32–256) onto a common D/8 grid. It keeps them as k=4 persistent residual streams inside a single plain ViT, with an identity residual mapping (Hres=I, unlike the mixing used in HC/mHC). Feature-wise gates read the streams into one length- sequence, and token-wise gates in write the shared sublayer update back into each stream. The decoder sees only the final states. App. C shows that doubly stochastic mixing contracts the differences between streams, while the identity mapping preserves them.
Experiments cover AMOS-22 (CT/MRI), LiTS, KiTS-23, BraTS-25-GLI and MAMA-MIA on the authors' own 7:1:2 splits. Four model sizes (27–214 M params) are compared with 12 baselines over 3 seeds. Every Flumina size has the best average DSC, e.g. 82.95 vs 81.48 (MedNeXt) on the 4-dataset mean (Table 3), and the paper reports Wilcoxon significance. Single-seed ablations (Tables 4/5) and latency studies with efficient attention kernels (App. H) complete the evaluation.
Strengths
Crisp conceptual framing that leads directly to the design
Sec. 1, Fig. 1, Sec. 4.3, Table 4
The paper separates the task requirement (preserve structure) from the U-Net mechanism (skips), which makes the design space explicit. The 2×2×2 ablation grid of Table 4 (tokenizer × skips × multi-state, with Transformer vs identity) tests the hypothesis directly. All 13 verbal claims of Sec. 4.3 hold on the printed numbers (check 05). Example: the Transformer adds +7.80 DSC on average to Flumina but only +0.51 / −0.25 to the semantic-encoder variants.
Reimplementable and internally consistent architecture description
Sec. 3.2, Table 1, App. B, App. H.1
Widths, kernel/stride choices, gate ranges, normalisation placement and the 3D RoPE split are all specified. Table 1 dimensions are mutually consistent: dhead divisible by 6, and 8C and are integers (check 10). The reported parameter and MAC counts (27.3–213.5 M, 0.42–1.56 T) imply a near-constant fixed tokenizer/decoder part, 4.22–4.70 M and 0.252–0.257 T (check 09). Eq. 36–38 reproduce the quoted 29.381 G / 1.887 G / 0.063 G for Flumina-B exactly (check 08).
Weaknesses
Ablation reference row matches no reported Flumina model; ablations are single-seed with sub-noise deltas
major · Tables 4, 5; Sec. 4.3; l. 429
Tables 4/5 support the Q2–Q4 claims (multi-state, no skips, identity mapping, RMSNorm, gating). Their Flumina row (88.19 / 85.30 / 86.32 / 82.10 / 77.03) matches none of the four variants in Tables 2/3. The closest, Flumina-B, deviates by up to 0.58 pp, and KiTS 86.32 and MAMA 77.03 exceed every variant in Table 3 (max 86.25 / 76.83; check 06). The paper does not state which variant, which split, or how AMOS CT/MRI are combined. All ablations use one seed (l. 429), and 9/35 per-dataset deltas in Table 5 are below 0.30 pp, including every Q3/Q4 AMOS delta (−0.14 to −0.27; check 05). The claim that identity beats mHC rests on a 0.47 pp mean difference, and mHC actually wins on LiTS (85.46 vs 85.30). Fix: name the variant and split, run ≥3 seeds for Tables 4/5, and report standard deviations or paired tests.
Significance claim overstated relative to the paper's own per-dataset tests
The Table 2/3 notes state that all four variants are significantly better than the baselines (Wilcoxon, p<0.05). Table 13 has 10/240 per-dataset cells with p≥. On LiTS no variant is significant against MedNeXt (0.258–0.363) or Primus-V2 (0.134–0.317), and on BraTS Flumina-S is not significant against U-Net (0.081) or MedNeXt (0.203). With Holm correction within each dataset, 26/240 comparisons fail (check 07). The blanket statement rests on pooling four datasets with very different case counts, where BraTS's 578 cases dominate, and no multiplicity correction is applied. Table 13 also orders its columns S, B, L, M, unlike every other table. report per-dataset corrected tests and soften the wording to what they support.
Questions for the authors
Which Flumina variant, seed and split (validation or test) produced the reference row of Tables 4/5, and how are AMOS CT and MRI combined into the single 'AMOS-22' column? Do the identity-vs-mHC and gating conclusions survive 3 seeds?
Was the MedNeXt baseline MedNeXt-B (10.5 M / 0.17 T, matching Table 3) or MedNeXt-L as stated in App. H.4? If B, how does MedNeXt-L (or another CNN of size comparable to Flumina-L) compare?
How many AMOS-MRI test cases are there, and how many gallbladder cases receive the empty-mask diagonal penalty for each model? Does Flumina-B's gallbladder advantage persist across all three seeds?
Why does the default nnU-Net score below your PlainConvUNet on LiTS and KiTS-23? Which nnU-Net configuration (3d_fullres or cascade) and fold structure was used?
How much hyper-parameter search was done for Flumina compared with the baselines, and was it done on the validation split only?
Are the column labels of Table 13 (S, B, L, M) correct, or should they be S, B, M, L as in all other tables?
Verification
Only the PDF was available. No code, data or checkpoints were supplied, and the anonymous repository returned a bot challenge (check 18), so no segmentation result was regenerated. Instead, 18 checks tested internal consistency and arithmetic. Fourteen confirmed: every table average (336 cells), the DSC/IoU Jensen bounds (736 cells), the ablation deltas and verbal claims, the MAC/parameter formulas, the latency tables, the theory in App. C and the references. They also exposed fragility: the MRI lead halves without one organ, the MRI HD95 lead disappears without it, and many ablation deltas are below 0.3 pp. Two discrepancies were found: the ablation reference row matches no reported variant, and the 'MedNeXt-L' baseline has MedNeXt-B's size. The significance claim was inconclusive, because the pooled tests cannot be recomputed and the per-dataset p-values do not uniformly support it. These checks concern reporting consistency only. They are no evidence that the underlying DSC values are reproducible.
Zhang, Jiang, Gao, Willett, Maire. Residual connections harm generative representation learning (cited as Zhang et al., 2026b; arXiv 2404.10947)
Cited in Sec. 1 (l. 88-90) for the claim that U-shaped skip connections make segmentation predictions less dependent on Transformer representations. Its abstract concerns identity shortcuts in residual networks for MAE and diffusion representation learning. It does not mention skips, U-Nets, segmentation or Transformers, so the support is indirect at best. The paper actually argues for down-weighting unit-gain identity paths with depth, while Flumina deliberately keeps 'an unmodified, unit-gain path' (App. C, Eq. 32). The tension is not discussed.
Song et al. Uni-encoder meets multi-encoders: Representation before fusion for brain tumor segmentation with missing modalities. CVPR 2026 (Song et al., 2026b; arXiv 2604.22177)
Exists. Cited alongside Zhang 2026b for skips reducing reliance on Transformer representations. The abstract describes a two-stage ViT plus CNN fusion method for missing-modality brain tumour segmentation and makes no such claim. Support could only be checked at abstract level.
Heller et al. The KiTS21 challenge: Automatic segmentation of kidneys, renal tumors, and renal cysts in corticomedullary-phase CT. 2023 (arXiv 2307.01984)
Cited as the source of the KiTS-23 dataset (Sec. 4.1, App. D). The reference is the KiTS21 challenge paper, which describes a different, smaller release. The KiTS-23 dataset (489 cases) should be cited through its own challenge description or repository.
The arXiv record is titled 'Spectral-Sphere-Constrained Hyper-Connections'. The cited title adds a prefix that is not in the arXiv metadata, which is minor and possibly from a different version.
Aboian et al. MICCAI 2025 Lighthouse Challenge: Brain Tumor Segmentation Cluster of Challenges (BraTS). Zenodo 2025, doi 10.5281/zenodo.15094823
The DOI resolves to a Zenodo record (a challenge proposal document), not a peer-reviewed dataset paper. It is acceptable as a data source, but the 2,872-exam annotated subset and the 'full cohort of 3,279 examinations' (App. D) cannot be traced to this reference.
Suggestions
Rerun the Table 4/5 ablations with ≥3 seeds on the same variant and split as the main results. Identify that variant, and report mean ± std or paired tests.
Replace the blanket significance note with per-dataset, multiplicity-corrected tests, and state explicitly where Flumina is not significantly better (LiTS vs MedNeXt and Primus-V2).
Clarify the MedNeXt configuration and add a size-matched strong CNN baseline, e.g. MedNeXt-L or a scaled nnU-Net ResEnc-L.
Report results on at least one official benchmark test set (e.g. AMOS-22 or KiTS-23) so the numbers can be compared with the literature.
Report the AMOS-MRI test size, per-organ case counts and the number of empty-mask HD95 penalties. Give HD95 with and without the penalty.
Quantify the motivating dilemma, e.g. how much the decoder output changes when Transformer blocks are ablated with and without skips, rather than relying on Fig. 1 alone.
Reframe App. C as a motivating observation about the carried component, or extend it to the learned updates Δt.
Discuss HRNet-style parallel multi-resolution networks and multi-scale ViTs in Sec. 2, and cite KiTS-23 through its own dataset description.
Release the split lists and per-case predictions alongside the code so the tables and Wilcoxon tests can be reproduced.
Ethics and integrity
No concerns. The study uses public datasets only, and the AI-assistance statement (GPT-5.5, GPT-5.6 Sol, GPT-6 Astra, Codex) is disclosed. No hidden or injected instructions were found in the PDF text. The detected inconsistencies (ablation reference row, MedNeXt size) look like reporting errors, and nothing suggests fabrication.
Scope of this review
Only the PDF was available. No LaTeX source, code, data, split lists or checkpoints were supplied, and the anonymous repository (https://anonymous.4open.science/r/Flumina) was blocked by a Cloudflare challenge. None of the DSC/IoU/HD95, ablation or latency numbers could be regenerated. Checks were limited to internal arithmetic consistency, analytic complexity formulas, numerical tests of the theory, comparison with the MedNeXt paper's configuration table and reference lookups. The citation-support checks were done at abstract level. Figures 3 and 14 could not be read reliably from the extracted text.
The benchmark spans five datasets, 12 recent baselines, 3 seeds, a uniform 250k-iteration budget, per-baseline hyper-parameters (Table 7) and DSC/IoU/HD95. All 96 AMOS and 240 multi-dataset average cells recompute within 0.015 (checks 01, 02). All 736 DSC/IoU cell pairs satisfy the Jensen bounds implied by Eq. 33 (check 03), so the IoU and DSC tables are consistent with coming from the same segmentations.
Practical efficiency study
App. H, Tables 14–16
Read/write overhead is accounted analytically, and wall-clock latency is measured with several attention kernels and a fused Triton upsample. All ratios and summary ranges in Tables 14–16 recompute exactly, e.g. attention speed-ups of 10.04–28.25× and case-level speed-ups of 1.85–2.80× (checks 11, 12). The paper also reports that the Vanilla-attention variants are slower than U-Net.
Correct, if standard, theory for the carried component
App. C Eq. 17–31; App. B Eq. 11
The non-expansiveness of doubly stochastic mixing, the Dobrushin contraction of the state diameter and the convergence to the mean all hold numerically over 3,000 random instances with no violation (check 10). The RoPE identity, Eq. 11, holds to 10−14.
0.05
Fix:
Strongest CNN baseline is mislabelled or its complexity is misreported
major · Table 3 MedNeXt row; App. H.4 l. 1698–1700; Table 16
App. H.4 and Table 16 call the MedNeXt baseline 'MedNeXt-L'. Table 3 lists it at 10.5 M params / 0.17 TMACs, which exactly matches MedNeXt-B (k=3) in Roy et al. 2023. MedNeXt-L is 61.8 M / 0.50 T (check 15). Either the second-strongest baseline (81.48 avg DSC) is a model about 6× smaller than named, which weakens the 'beats strong CNNs' conclusion given Flumina-L is 213.5 M, or the complexity columns are wrong. The latency claim that Flumina-L is 'comparable to MedNeXt-L' inherits the ambiguity. Fix: state the exact configuration and, if it was MedNeXt-B, add MedNeXt-L (or a size-matched CNN).
Margins over the best baseline are small and partly driven by one organ
The weakest variant, Flumina-S, leads the best baseline by only +0.07 (MAMA-MIA), +0.11 (AMOS-MRI) and +0.13 (BraTS) DSC (check 17). Flumina-B's best MRI average depends heavily on gallbladder DSC 84.12, against ≤76.01 for 14 other models. Without that organ, its lead over Primus-V2 halves from 1.08 to 0.49 pp (check 04). The App. G.2 claim that B has the lowest MRI HD95 does not survive removing the gallbladder: Primus scores 5.66 mm vs B's 5.85 mm. Its 8.85 mm vs 39–84 mm for the others likely reflects the empty-mask diagonal penalty (App. F) in a test subset of roughly 12 cases, whose size is not reported. Fix: report the AMOS-MRI test size and per-case distributions, and give HD95 with and without empty-mask penalties.
Baseline strength and protocol fairness are hard to assess
major · Sec. 4.1; App. D Table 6; App. E Table 7; App. G.4 Table 12
All results use custom 7:1:2 splits rather than the official AMOS/KiTS-23/BraTS evaluation, so they cannot be compared with published numbers. The default nnU-Net in Table 12 scores at or below the authors' own PlainConvUNet on LiTS (−0.54), KiTS (−0.51) and BraTS (−0.01) (check 13), which is unusual and suggests the protocol rather than the architectures limits the baselines. nnU-Net also beats Flumina-S and Flumina-L on AMOS-MRI (83.77 vs 83.59 / 83.65). Baselines are trained for 250k iterations at batch 2 with their original recipes, while Flumina uses its own cosine recipe (Table 7). The tuning budget for each is not reported. Fix: add results on at least one official test set, report the tuning effort, and explain the nnU-Net result.
'Theoretical justification' does not justify the identity choice
minor · Sec. 1 contributions l. 113–120; App. C
App. C proves standard Dobrushin/Seneta facts: doubly stochastic mixing contracts the diameter of the carried component, and the identity mapping preserves X0. These results ignore the learned updates Δt, so they cannot explain why identity should outperform mHC in trained networks, and the paper's own Table 5 shows mHC ahead on LiTS. The exact bound ∥H∥2≤1 is also an idealisation: with 20 Sinkhorn iterations, ∥H∥2 exceeds 1 by up to 1.5×10⁻² (check 10). Contribution (2) should be presented as a motivating observation, or extended to include Δt (e.g. an analysis of the gate-weighted update subspace).
Unsupported citations for the core motivating claim
minor · Sec. 1 l. 88–92; Sec. 4.1; References
The statement that skips make predictions 'less dependent on Transformer representations' (l. 88–90) cites Zhang et al. 2026b and Song et al. 2026b. At abstract level neither makes this claim. Zhang 2026b instead argues against unit-gain identity paths, which Flumina deliberately keeps (App. C, Eq. 32), and the tension is not discussed. KiTS-23 is cited through the KiTS21 paper. Apart from Fig. 1, which is qualitative, the dilemma has no quantitative support such as a measured decoder dependence on Transformer features.
Missing related work on parallel multi-resolution streams
minor · Sec. 2; App. A.1
Keeping several resolutions as parallel persistent streams with repeated exchange is the core idea of HRNet, and of multi-scale ViTs such as MPViT and CrossViT. Skip redesigns (UNet++, UNet 3+, UCTransNet) are also relevant. None is discussed in Sec. 2, which leaves the novelty relative to these designs unclear.
Small internal inconsistencies in the efficiency tables
minor · Tables 3, 14, 15
For Flumina-L, the Table 3/9 BraTS scores (82.12 / 76.00) match the SDPA run in Table 14 (82.122 / 76.000), not the Vanilla reference (82.112 / 75.990). The Flumina-M 'Original' latency in Table 15 (0.2737 s) differs from Table 14 (0.275 s) (check 11). U-Net params are given to two decimals (90.31). These do not change the conclusions.
App. C Eq. 17-31 (non-expansiveness of doubly stochastic mixing, Dobrushin contraction, convergence of carried states to the mean, identity preserves diameter) and App. B RoPE identity Eq. 11; m=d_head/6 integral
0 violations of Eq. 17-19, 21 (two tau formulas agree), 22, 25, 26, 28, 29 and 31. The worst LHS/RHS ratio is 1.0 for Eq. 22/26 (tight) and 0.63 for Eq. 29. RoPE Eq. 11 holds to 1e-14 and equals the real dot product of the rotated pairs. d_head = 48/48/66/72 gives m = 8/8/11/12, and 8C/3 and C/8 are integers for all variants. The statements are correct but standard (Dobrushin/Seneta). They concern only the carried component, not the learned updates Delta_t, so they do not show that identity outperforms mHC. Side observation: with 20 Sinkhorn iterations, ||H||_2 exceeds 1 by up to 5e-3 (logit scale 3, 39% of draws) or 1.5e-2 (scale 5). The exact non-expansiveness in Eq. 17-19 is therefore an idealisation of mHC as implemented.
Monte Carlo, 3000 trials, seed 0, k=2..6, depth T up to 29. Converged Sinkhorn-normalised exp(Gaussian) matrices and exactly doubly stochastic Birkhoff mixtures, including near-permutations. 10,000 random RoPE instances. Side check of mHC's finite (20-iteration) Sinkhorn
Table 14 speedups and summary ranges (attention 10.04x-28.25x, crop 1.79x-2.71x, case 1.85x-2.80x, DSC/IoU within 0.06 pp); Table 15 speedups and memory reductions
0 mismatches. Ranges recomputed exactly: attention 10.04-28.25x, crop 1.79-2.71x, case 1.85-2.80x, max |dDSC|,|dIoU| = 0.06 (Flumina-L SageAttention3: -0.059/-0.060). Table 15 speedups (1.225/1.173/1.119/1.103x) and memory reductions (57.57/54.87/50.01/46.64%) match. Minor inconsistencies: for Flumina-L, Table 3/9 BraTS (82.12/76.00) matches the SDPA run (82.122/76.000) rather than the Vanilla reference (82.112/75.990, which rounds to 82.11/75.99). The Table 15 'Original' latency for Flumina-M (0.2737 s) differs from the Table 14 SDPA entry (0.275 s).
Parsed 20 Table 14 rows and 4 Table 15 rows from the PDF. Recomputed ratios, throughputs, deltas and ranges, and cross-checked against Tables 3/9
Table 16: Total = s/case x N, speedup vs U-Net. Flumina-S/B are faster than U-Net on all five datasets with every efficient kernel. With SageAttention3, Flumina-L is comparable to MedNeXt-L and faster than SegMamba-V2
0 arithmetic mismatches over 115 cells. N matches the Table 6 test splits (72/578/98/26/301). With every efficient kernel, S and B are faster than U-Net on all five datasets (S 1.70-1.92x, B 1.30-1.42x). With SageAttention3, L is faster than SegMamba-V2 everywhere and takes 0.97-1.00x the latency of MedNeXt-L; M reaches 0.94-0.98x U-Net speed. Without an efficient kernel (Vanilla), every Flumina variant is slower than U-Net (S 0.76-0.77x). Context: the U-Net reference is the authors' 'fixed' PlainConvUNet with 90.31 M params / 1.91 TMACs (Table 3), much heavier than typical, and 'MedNeXt-L' is listed as 10.5 M params (see check 15).
Parsed 23 rows x 5 datasets from the PDF. Recomputed totals and speedups (speedups from totals, because s/case is rounded to 3 dp), evaluated the verbal claims, and cross-checked N against Table 6 and the BraTS entries against Tables 14/15
Table 12 nnU-Net comparison: averages correct, Flumina columns match Tables 2/3, 'all four variants attain higher average DSC, with the largest gains on KiTS-23 and LiTS'
Averages match (nnU-Net 81.49, S 83.39, B 83.85, M 83.90, L 84.02; recomputed 81.492/83.390/83.853/83.900/84.022). All 24 Flumina cells are identical to Tables 2/3. For every variant the largest gains are LiTS (+4.66 to +6.39) and KiTS-23 (+3.40 to +4.08). nnU-Net beats Flumina-S (83.77 vs 83.59) and Flumina-L (83.65) on AMOS-MRI. On LiTS/KiTS/BraTS/MAMA, the default nnU-Net scores at or below the authors' own PlainConvUNet baseline (LiTS -0.54, KiTS -0.51, BraTS -0.01, MAMA +0.03). This is unusual for nnU-Net and suggests the planned configuration or split, not the architecture, limits these numbers. No seeds or significance tests are reported for nnU-Net.
Parsed Table 12 from the PDF; recomputed averages; compared Flumina columns cell by cell with Tables 2/3; computed per-dataset gains
Bookkeeping: Table 6 splits sum to the Sec. 4.1 dataset sizes at ~7:1:2; Table 7 warmup ratios; 1,000 x 250 = 250,000 updates; stride 8 gives L=4096 for 128^3 (512 at stride 16); projector kernels 8/2^(i-1) map all stages to D/8
All five split sums match (360, 131, 2,872, 489, 1,506), with ratios 69.9-70.2 / 9.7-10.0 / 19.8-20.1%. Warmup 41,666 = 16.67%, 2,500 = 1.00%, 12,500 = 5.00%; nnU-Net 1,000 x 250 = 250,000. 128^3 at stride 8 gives 4096 tokens (512 at stride 16), and every projector maps to 16^3. The AMOS-MRI test subset size is not reported (12 cases if proportional), and the 64x160x192 crops give 3,840 tokens. BraTS uses 1,830 patients across the splits (1.57 exams per patient).
Arithmetic
The MedNeXt baseline is 'MedNeXt-L' (App. H.4, Table 16), yet Table 3 lists 10.5 M params / 0.17 TMACs
Roy et al. Table 3 lists MedNeXt-S 5.6 M/130 GFLOPs, B 10.5 M/170, M 17.6 M/248, and L 61.8 M/500 (k=3). The 10.5 M / 0.17 T in the Flumina paper matches MedNeXt-B (k=3) exactly, not MedNeXt-L (61.8-63.0 M, 0.50-0.56 T). Either the strongest CNN baseline was MedNeXt-B, about 6x smaller than the name says, or the complexity columns are wrong. Either way the text calls it 'MedNeXt-L' in App. H.4 / Table 16, and the 'comparable to MedNeXt-L' latency claim inherits the ambiguity.
Downloaded Roy et al. 2023 (arXiv 2303.09975) and parsed its configuration table (params and GFLOPs for a 128^3 patch, kernel 3/5)
References exist and match their citations, especially the 2026 arXiv/venue items, the KiTS-23 dataset citation and the Primus-V2 attribution
All 69 references resolve to real works: 55 by automatic title match and the other 14 by manual follow-up (CROWn has an official repo stating CVPR 2026 acceptance; FlashAttention-4 is arXiv 2603.05451; SageAttention2++ is arXiv 2505.21136; the Aboian DOI resolves to a Zenodo record; the OpenAI system cards are found by web search). Primus-V2 is introduced in the Primus paper (abstract: 'termed Primus and PrimusV2'), so the attribution to Wald et al. 2026 is correct. Issues, listed in work/ref_issues.json: KiTS-23 is cited through the KiTS21 paper. The two citations for 'skips make predictions less dependent on Transformer representations' (Zhang 2026b, Song 2026b) do not make that claim in their abstracts, and Zhang 2026b argues against unit-gain identity paths of the kind Flumina keeps. The Liu 2026 title differs from the arXiv record. Follow-up scripts: work/verify/16b_refs_followup.py, work/verify/16c_ref_support.py.
tools/check_refs.py (Crossref + arXiv) on all 69 references. Title-similarity triage (16_refs_summary.py). Follow-up arXiv title searches, DOI resolution and abstract fetches (16b, 16c). Web search for CROWn (CVPR 2026) and the GPT-6 Astra system card
App. G/J claims: all variants beat all baselines in mean IoU on AMOS CT/MRI; Flumina has the highest mean IoU on each dataset; four-dataset HD95 decreases S->L (22.78 vs Primus-V2 33.07); L/B have the lowest AMOS CT/MRI HD95; scaling S->B improves DSC on all five datasets
13/13 statements hold on the printed tables. IoU CT: min Flumina 80.94 > max baseline 79.92. IoU MRI: 75.46 > 75.24. HD95 4-dataset S->L: 28.59 > 27.18 > 24.77 > 22.78 (Primus-V2 33.07). S->B DSC gains: +0.37 CT, +0.97 MRI, +0.80 LiTS, +0.25 KiTS, +0.25 BraTS, +0.14 MAMA. Context: the weakest variant (S) leads the best baseline by only +0.07 (MAMA), +0.11 (AMOS-MRI) and +0.13 (BraTS) DSC. On KiTS HD95, Primus (31.31 mm) beats Flumina-S/B/M (32.34-33.95 mm).
Parsed Tables 2, 3, 8-11 from the PDF and evaluated 13 statements programmatically
All three requests returned HTTP 403 with a Cloudflare 'Just a moment...' bot challenge, so the repository content could not be listed or inspected from the review environment. No code was supplied with the request. Consequently, none of the DSC/IoU/HD95, latency or ablation numbers could be regenerated. Checking them would need the code, the fixed 7:1:2 split lists and the checkpoints or per-case predictions.
Read-only HTTP requests to the repository page and the anonymous-github file-listing API (nothing executed)
AMOS-22 Avg. columns (Tables 2, 8, 10) equal per-organ means; Flumina-L best CT DSC 88.66, Flumina-B best MRI DSC 84.56 vs Primus-V2 87.58/83.48
96/96 Avg. cells match recomputed organ means within 0.015. Rankings as stated: CT DSC Flumina-L 88.66 > Flumina-B 88.55, best baseline Primus-V2 87.58; MRI DSC Flumina-B 84.56 > Flumina-M 84.26, best baseline Primus-V2 83.48. HD95: CT Flumina-L 11.23 (Primus-V2 11.82), MRI Flumina-B 6.08 (best baseline Primus 9.22).
Parsed all 96 rows from the PDF, recomputed means of 15 CT / 13 MRI organs, recomputed rankings
Tables 3/9/11 dataset means and 4-dataset Avg. arithmetic; Flumina-L 4-dataset DSC 82.95 vs best baselines 81.48 (MedNeXt) / 81.40 (Primus-V2)
240/240 recomputed cells match within 0.015 (0.02 for chained average). DSC Avg ranking Flumina-L 82.95 > M 82.66 > B 82.50 > S 82.14 > MedNeXt 81.48 > Primus-V2 81.40; IoU Flumina-L 75.76 vs MedNeXt 73.86; HD95 Flumina-L 22.78 vs Primus-V2 33.07.
Parsed 48 rows from the PDF, recomputed LiTS/KiTS/BraTS region means and equal-weight 4-dataset average
Every mean IoU cell satisfies f(mean DSC) <= mean IoU <= mean DSC, f(x)=x/(2-x) (consequence of Eq. 33 + Jensen)
0/736 violations at tolerance 0.01 pp; slack IoU - f(DSC) ranges -0.01 to 11.19 pp. The IoU tables are consistent with being computed from the same per-case segmentations as the DSC tables.
sympy: f''(x)=-4/(x-2)^3>0 and x-f(x)>=0 on [0,1]; checked all 736 paired DSC/IoU cells parsed from the PDF
Flumina-B's best AMOS-MRI average (84.56 DSC, 6.08 mm HD95) is not driven by the single gallbladder column (84.12 DSC / 8.85 mm vs <=76.01 / >=39.30 mm for the 14 other models except Flumina-M)
DSC: without gallbladder Flumina-B stays first (84.60 vs Flumina-M 84.41, Primus-V2 84.11), but its margin over the best baseline halves (1.08 -> 0.49 pp) and its margin over Flumina-S drops from +0.97 to +0.30 pp; B is the best Flumina variant on only 2/13 organs. HD95 (not robust): without gallbladder Primus (5.66 mm) beats Flumina-B (5.85 mm), so the App. G.2 statement that Flumina-B has the lowest MRI HD95 rests on one organ (8.85 mm vs 39.30-83.71 mm for 14 models). The MRI test subset size is not stated (about 12 cases if the 72-case test split is proportional); one empty-mask case with diagonal penalty D shifts an organ mean by D/12.
Recomputed MRI averages without the gallbladder for all 16 models; per-organ wins; leave-gallbladder-out ranking
Ablation Tables 4/5 arithmetic (deltas, Overall Mean) and the verbal claims of Sec. 4.3
0 arithmetic mismatches (tolerance 0.015). All stated comparisons hold on the printed numbers: multi-state vs single-state w/o skips (Tr) +1.91..+3.03 on all five; adding skips to Flumina lowers all five (-0.38..-2.55); Transformer gain +7.80 mean for Flumina vs +0.51 (b) and -0.25 (c) for semantic-encoder variants; mHC > HC on all five (+0.07..+1.70); identity best mean 83.79 vs mHC 83.32 / HC 82.75 (but mHC beats identity on LiTS, 85.46 vs 85.30); P-Norm removal and uniform read lower all five; shared write has the smallest mean drop (-0.58). Caveats: single seed; 9/35 Table 5 per-dataset deltas are below 0.30 pp, including all five Q3/Q4 AMOS deltas (-0.14..-0.27); the d-vs-e 'removing skips improves average' holds on the mean (+0.69) but only on 3/5 datasets (BraTS -0.56, MAMA -0.99).
Parsed 20 ablation rows from the PDF, recomputed deltas vs Flumina and 5-dataset means, evaluated 13 verbal claims programmatically
The Flumina reference row of Tables 4/5 (88.19, 85.30, 86.32, 82.10, 77.03) corresponds to a reported Flumina variant
No variant matches: the smallest maximum deviation is Flumina-B at 0.58 pp (S 0.75, M 1.10, L 1.32). KiTS 86.32 and MAMA-MIA 77.03 exceed every variant in Table 3 (max 86.25, 76.83). AMOS 88.19 is closest to the Flumina-S CT average (88.18), but no AMOS combination fits the other variants. The most likely explanation is a single-seed run (l. 429) of an unspecified variant, possibly on an unspecified split. The paper does not say which variant or split the ablations use, or how the AMOS CT and MRI scores are combined, so the ablations cannot be tied to the main results.
Compared the row with all four variants in Tables 2/3, trying CT, MRI, plain, organ-weighted and case-weighted AMOS combinations
Tables 2/3 notes: all four Flumina variants significantly better than the baselines (Wilcoxon, p < 0.05)
The pooled tests behind the Table 3 note cannot be recomputed without per-case DSC. Table 13 is consistent with the Table 2 (AMOS) note, where all 48 cells are < 0.001. 10/240 per-dataset cells have p >= 0.05: on LiTS no variant is significant against MedNeXt (0.258-0.363) or Primus-V2 (0.134-0.317), and on BraTS Flumina-S is not significant against U-Net (0.081) or MedNeXt (0.203). With Holm correction within each dataset, 26/240 comparisons are not significant (LiTS 19, BraTS 5, MAMA 2). No multiplicity correction is reported. Table 13 orders its columns S, B, L, M, while every other table uses S, B, M, L. Correlating DSC gaps with p-values does not settle which order is correct (concordance 35/52 vs 29/52). The blanket 'over the baselines' wording in the Table 3 note rests on pooling four datasets, which the per-dataset results do not uniformly support.
Parsed all 240 per-dataset p-values of Table 13; counted p >= 0.05; Holm correction within each dataset (48 tests, '<0.001' taken as 0.001); minimal attainable exact Wilcoxon p; column-order consistency test against DSC gaps
App. H.1 Eq. 36-38: Flumina-B block = 29.381 G MACs, reads 1.887 G (6.42%), writes 0.063 G (0.21%)
Eq. 36 simplifies to (k/4)LC^2 and Eq. 37 to k^2 LC. Flumina-B: 29.381 G / 1.887 G (6.42%) / 0.063 G (0.21%), all exact matches. The read share grows with width: S 4.70%, M 8.20%, L 8.50% of block MACs. The paper quotes only the B figure, so the 'modest overhead' statement understates the L case slightly.
sympy simplification of Eq. 36-38; exact evaluation at L=4096, C=480, k=4 and for the other variants
Table 1/3 params (27.3/66.1/147.9/213.5 M) and MACs (0.42/0.69/1.15/1.56 T) agree with the described architecture
Implied fixed part: 4.22/4.35/4.50/4.70 M params (spread 0.48 M = 1.8% of Flumina-S) and 0.253/0.252/0.257/0.255 T MACs (spread 0.005 T, below the 0.01 T rounding). The small parameter drift grows with depth x width and fits per-block bias, norm and LayerScale vectors (about 40C per block). The reported sizes are consistent with the described design.
Analytic count of the width/depth-dependent parts (blocks with reads/writes, projectors with kernel=stride 8/4/2/1, transposed-conv restorers, positional embedding; MACs via Eq. 38 and per-token projector cost). Then checked that the implied fixed part (tokenizer and decoder) is the same across variants