Summary
The paper releases S-OH, a clinical electronic-nose dataset: 1,234 patients in nine diagnostic groups (eight disease groups plus healthy), each recorded as a 17-channel metal-oxide sensor time series (358 steps, 895 s). Recordings span 13 weeks at two sites, and every sample carries its collection week. On top of the dataset it defines Breath-Dx, a benchmark of nine one-vs-rest screening tasks with week-disjoint ("temporal") train/test splits (Table II). It evaluates 10 methods (gradient-boosted trees and random forests on hand-crafted features, a CNN and ResNet18 on feature images, Graphormer, LSTM, InceptionTime, TS2Vec) plus a logistic-regression baseline, using ROC AUC averaged over 16 seeds (Tables III–IV).
The paper makes three headline claims. (1) Temporal validation lowers AUC by 0.05–0.12 compared with random cross-validation for all methods, so random CV should be abandoned (Table V). (2) No method dominates: LSTM is the most consistent (mean AUC 0.598, top-3 in 5/9 tasks), and InceptionTime and Graphormer reach about 0.75 on lung cancer and COPD. (3) Demographics are strong confounders. Age alone gives AUC 0.967 (healthy), 0.678 (lung cancer) and 0.803 (tuberculosis), while sensors add independent value for liver disease and gastritis (Table VI).
Strengths
A sizeable public clinical eNose dataset whose metadata match the paper
Sec. IV, Table I, Fig. 1, Sec. IV-E (data link)
S-OH is downloadable from HuggingFace (metadata.csv with 1,234 rows plus the sensor dictionary). Every cell of Table I (N, age mean/SD, %male per group) matches the released metadata within rounding (check 10). All 117 week×diagnosis cells of Fig. 1 match exactly (check 11). All 1,234 records have 17 sensor channels with 357–359 steps, except one 226-step record (check 15). Patient-level age, sex, site and collection week are rarely released for clinical breath data, and they enable exactly the confound and drift analyses this field lacks.
Sensor drift treated as a first-class evaluation problem, and the drift signal is real
Sec. III-B, Sec. V-G, Table II
The paper puts week-disjoint evaluation at the centre of the benchmark (Sec. III-B, Table II), and the split lists in the code match Table II for all nine groups (check 11). The underlying premise is strongly supported. In our rerun the measurement day is predictable from raw sensor levels with a median absolute error of 0.74 days (median-day baseline: 21 days). Error rises to 1.47 days once per-series levels are removed, which confirms that the temporal signal sits mostly in baseline shifts, as Sec. V-G states (check 09).