A well-engineered, reproducibly scored harness whose numbers check out, but the headline win over GPT-6 Astra is a mean effect driven by a few baseline failures (Astra is better on more parts), the baselines get no simulator feedback, the LLM adds only 0.35 pp, and the released 'benchmark' omits the target parts and misstates where the materials come from.
Soundness
3/4
Presentation
3/4
Contribution
3/4
Confidence
4/5
✓ 12 confirmed✕ 4 discrepancy
Summary
The paper presents MillBill, a system that turns a B-rep part, a stock and a material into G-code for indexed three-axis milling. The design principle is a strict division of labour: a language model (Qwen3.8-27B, run locally) only revises a rule-based reference plan of operations, tools and cutting parameters, while a geometric harness does everything numerical: AAGNet feature recognition, reach-aware setup selection among the six axis directions (Eq. 2), FreeCAD and height-map toolpaths, an exact swept-cutter material-removal simulation (Eq. 3), and a surface-accuracy metric Accτ (Eq. 5). Simulator feedback drives up to three builds per setup, and the best build is kept.
On 100 GrabCAD parts drawn from a collection of 4,294 parts with authored stocks, MillBill reports 97.4% of the target surface within 0.1 mm, against 94.3% for a code-writing GPT-6 Astra agent, 83.0% for a Claude Opus 5.5 agent, 7.9% for a Qwen3.8-27B code-writing agent and 42.3% for CNC-Net (Table 1). The paper candidly shows that the reference plan without any LLM already reaches 97.0% (Table 2), that reach-aware setup planning is essential (fixed +z setup: 66.4%), and that at τ = 0.05 mm the Astra agent is slightly ahead (Table S4). The code and the stocks are released.
Strengths
Clear design principle with an honest ablation
Sec. 1; Sec. 4.3, Table 2
Separating machining decisions (LLM) from geometric execution (harness) is stated precisely and tested. The no-LLM ablation (97.0 vs 97.4, paired CI [0.09, 0.68], 43 better / 23 worse) openly shows that the harness carries most of the result; we confirmed these numbers are mutually consistent (sign test p = 0.019, check 06). Few agent papers report such a deflating ablation so plainly.
Common, simulation-based scoring of real G-code
Sec. 3.5; Sec. 4.1 'Metrics'; Table 1; Table S5
All systems' G-code is simulated and scored by one metric, with gouge and excess reported separately (they matter differently in practice), and per-part scores are released (Table S5). This made the headline means fully recomputable: 97.395, 94.324, 83.020, 7.863 and 42.269 match Table 1 within 0.04 pp (check 01).
Exact and correctly specified swept-volume simulator
Sec. 3.5, Eq. (3)–(5); Supp. S1 'Simulation and metric'
The removal test is described in enough detail to reimplement. Our reimplementation of Eq. (3) and the profile functions agreed with brute force on 20,000 random moves for flat, ball, bull-nose and conical cutters, with no convexity violations (check 10); the released numba kernel also agreed on 59,941 queries (check 14). The arc-chord rule and the 0.065 pp sampling-error bound hold (check 11).
Reach-aware setup planning is sound and matters
Sec. 3.2, Eq. (2); Table 2
Eq. (2) is correctly presented as a necessary condition; on synthetic height maps the dilation implementation matched brute force exactly, dominance pruning lost nothing, and no truly reachable voxel was rejected (check 13). The fixed +z ablation (66.4%) shows the component's large effect.
Detailed, internally consistent reporting
Tables 1, 2, S3, S4, S5; Fig. 4; Supp. S1
Table arithmetic (Acc + gouge + excess, boundary bands, Table S4 vs Table 1 and Sec. 4.4), setup counts (90 multi-setup parts, 430 setups, Fig. 4b 35+260+135), long-part subset means and the cutting-data formulas all check out (checks 03, 05, 09, 12). Knowledge-base counts match the released files.
Specific limitations section
Sec. 5
The paper names concrete gaps (no workholding or travel checks, holder test only necessary, no deflection, taps and thread mills not simulated, one run per method) rather than generic caveats.
Weaknesses
Headline win over GPT-6 Astra is a mean effect, not per-part superiority
major · Abstract; Sec. 1; Sec. 4.2; Table 1; Table S5
From Table S5 (99 parts scored for both) the mean paired difference is +3.05 pp with 95% bootstrap CI [+0.80, +5.76], so the mean advantage is real. But Astra is better on 52 parts and MillBill on 42 (sign test p = 0.35, Wilcoxon p = 0.26), the medians are identical (98.80 vs 98.80), and 7 parts where Astra scores below 80% contribute 263.7 of the 301.6 summed difference; dropping Astra's five worst parts shrinks the gap to +0.85 pp (check 02). The abstract's 'outperforms' should be qualified: MillBill is more robust (no catastrophic failures) rather than more accurate on a typical part. Report paired CIs, win/loss counts and medians in Table 1. By contrast, the advantage over Opus 5.5 is robust (+14.4 pp, 76 wins / 23 losses).
Asymmetric feedback between MillBill and the frontier baselines
major · Sec. 3.6; Sec. 4.1 'Baselines'; Sec. 4.4; Fig. 4a; Table S4
MillBill uses the evaluation simulator and the same Accτ to drive refinement and to pick the best of up to three builds, and its rest finishing is tuned to the evaluation tolerance (scallop τ/4); the GPT-6 Astra and Opus agents get no feedback on their programs (only the much weaker Qwen agent does). With one build MillBill reaches 95.6% (Fig. 4a) against Astra's 94.3%, a 1.3 pp mean gap that, given the per-part picture above, may not be significant. At τ = 0.05 mm Astra is ahead (90.2 vs 89.3, Table S4), and MillBill loses 8.1 pp from τ = 0.1 to 0.05 versus 4.1 pp for Astra (check 03), consistent with tuning to τ = 0.1. A fair comparison needs either a frontier agent given the same simulator feedback and build selection, or a paired test of MillBill's one-build result against Astra.
Questions for the authors
What is MillBill's per-part comparison against GPT-6 Astra with a budget of one build (no simulator-based selection)? Is the paired difference still significantly positive?
How does a GPT-6 Astra or Opus agent perform when given the same simulator feedback and best-of-three selection that MillBill uses?
What happens if a frontier model, or a much smaller model, replaces Qwen3.8-27B inside MillBill? Does the LLM ever matter beyond the 10 single-setup parts?
Which tool library (75 or 79 cutters) and which commit produced the reported results, and which library did the baselines receive?
Where do MillBill's ~19 mm mean maximum gouge depths come from, and on how many parts does a gouge exceed 1 mm in depth?
Was the workpiece material taken from the GrabCAD author (Supp. S2) or assigned from the knowledge base (dataset README)? If assigned, how?
How many candidate parts did the ≤0.5% unreachable-volume filter remove, and how do the baselines score on them?
Was the p02203 failure for GPT-6 Astra in its program or in the evaluator? If the latter, why is it excluded rather than fixed?
Verification
We ran 16 scripted checks (12 confirmed, 4 discrepancies, 0 inconclusive, 0 not checkable). All headline means, scored counts, table arithmetic, setup counts, long-part subset means, the ablation statistics' internal consistency, the swept-cutter simulator, the reach test, the arc and sampling bounds and the cutting-data formulas were confirmed by recomputation or reimplementation. A paired analysis of Table S5 shows that MillBill's advantage over GPT-6 Astra is significant in the mean but not per part (Astra wins 52 vs 42 parts; equal medians). The four discrepancies are secondary: different blank construction for MillBill vs the agents (negligible effect on Acc), a contradiction between Supp. S2 and the dataset README on where the materials come from, minor paper-vs-code constants, and a released tool library of 79 cutters instead of 75. The full pipeline could not be rerun end to end because the target parts and the GPU-hosted model are not available.
12Confirmed
4Discrepancy
✓ConfirmedAbstract; Sec. 1; Table 1 (p.7); Table S3; Table S5 (p.18); Sec. 4.4; Fig. S2 caption
[40] qwen38: Qwen Team. Qwen3.8-Max: A new bar for coding and cowork. https://qwen.ai/blog?id=qwen3.8, 2026.
Cited for the model that MillBill and the Qwen baseline actually run, Qwen3.8-27B in FP8 (Sec. 1, Sec. 4.1 'Implementation', Supp. S1), but the entry is the launch post of a different model, Qwen3.8-Max (a large MoE). According to web search, that post only announced the 27B, whose open weights were released separately (Qwen/Qwen3.8-27B and Qwen/Qwen3.8-27B-FP8, Aug. 2026). The static HTML of the cited page does not contain '27B' (work/verify/16_refs.log, section d), though it may be rendered client-side. For reproducibility the citation should name the exact checkpoint, e.g. the Qwen3.8-27B-FP8 model card with its revision.
Suggestions
Add paired statistics (bootstrap CI of the paired difference, win/tie/loss counts, medians) for every method pair in Table 1 and qualify the abstract's 'outperforms' accordingly.
Run a feedback-matched frontier baseline (same simulator feedback, same number of builds, same best-build selection) to isolate harness design from feedback access.
Swap the LLM inside MillBill (frontier model, small model, no model) and report per-part scores to substantiate the 'local open model suffices' claim.
Correct the material provenance statement in Supp. S2 and describe the released dataset accurately; provide target-file checksums or a script that fetches and verifies the GrabCAD parts.
Use one blank-construction path for all systems in the scorer, or quantify the difference explicitly.
Report gouge-depth distributions (e.g. fraction of parts with gouges > 0.5 mm and > 1 mm) next to gouge area.
State the exact commit, tool library and model checkpoint (Qwen3.8-27B-FP8 revision) used; reconcile the arc tolerance and stick-out constants with the code.
Repeat at least the frontier-agent runs a few times on a subset to estimate run-to-run variability.
Report wall-clock, GPU-hours and dollar-equivalent cost per part for MillBill alongside the baselines' $2 budget.
Ethics and integrity
No integrity concerns about the results: all recomputed numbers matched the paper. The material-provenance statement in Supp. S2 contradicts the authors' own dataset README; this looks like an error in the paper, not misconduct, but should be corrected. The released stocks are derived from GrabCAD models; the authors defer licensing to GrabCAD's Terms of Use, which the venue may want confirmed. Disclosure: one baseline (Claude Opus 5.5) belongs to the same model family as the reviewing system; it was treated like any other baseline. No instructions aimed at reviewers were found in the paper, source or code.
Scope of this review
The full pipeline could not be rerun: it needs FreeCAD, numba, an LLM server with Qwen3.8-27B on GPUs, AAGNet weights, and the target part STEP files, which are not released. Verification therefore relied on the per-part results in Table S5, the LaTeX source, the released stocks and evaluation list, reimplementations of the simulator, reach test and cutting-data model, and direct inspection and partial execution of the released code. The no-LLM ablation's bootstrap CI and the refinement curves (Fig. 4a) could not be recomputed because per-part data for them are not released. Baseline agent runs were not repeated.
The LLM contributes little, so the 'local open model suffices' claim is weakly tested
major · Sec. 1; Sec. 4.3; Table 2; Supp. 'Example plan and feedback'
The reference plan without any LLM reaches 97.0% vs 97.4% (Table 2). The LLM's whole gouge benefit comes from the 10 single-setup parts (implied mean gouge 1.26% vs 3.65%; multi-setup 0.46 vs 0.45), roughly 24 pp summed over 10 parts, one of which is the worked deburring example p02334 (check 06). The comparison that matters is therefore 'rule-based harness vs code-writing agent', and the claim that a mid-sized local model 'suffices' is untested because no stronger or weaker model is swapped into MillBill. Add a run with a frontier model and a small model inside the harness, and release per-part no-LLM scores (the reported bootstrap CI could not be recomputed).
Released 'open benchmark' omits the targets, and material provenance is contradicted
major · Sec. 1 contribution (ii); Sec. 4.1 'Parts'; Supp. S2 'Materials'; repo dataset/README.md
The repo contains 4,294 blank.step stocks and part.json files (counts confirmed exactly, check 07) but no target part STEP files; tasks can only be rebuilt by downloading each model from GrabCAD, and the dataset README says 21 links are reconstructed and unverified. Supp. S2 states the workpiece material 'is the one specified by the author of the model on GrabCAD', whereas the authors' own dataset/README.md says 'It is not a material stated by the GrabCAD author' but one assigned from MillBill's knowledge base (check 08). This also makes the candidate filter 'material in the knowledge base' vacuous. Correct Supp. S2, describe the contribution as a stock collection plus links, and provide checksums of the target files so third parties can verify they score the same parts.
Benchmark filtered with the method's own reach analysis
minor · Sec. 4.1 'Parts'; Supp. S2
Candidates are kept only if at most 0.5% of the removal volume is unreachable from the six directions using MillBill's own reach test, and stocks come from the authors' rules. This aligns the benchmark with the method's assumptions (axis-aligned setups, its tool library) and may disadvantage approaches with different assumptions. Report how many candidates the filter removed and baseline scores on a sample of excluded parts.
Scoring path differs in how the stock is represented
minor · Sec. 3.5; Sec. 4.1 'Metrics'; Table S3 caption; cam_agent/evaluate.py:173, tools/exact_metric.py:82-91
Sec. 3.5 and 4.1 say the same function scores all systems, but the uncut-stock rows of Table S3 differ for MillBill and Opus on the same parts and stocks: excess proxy 503.28 vs 503.56 cm³ and mean max gouge depth 0.00 vs 0.40 mm. The released code builds the blank differently (session mesh/box for MillBill vs re-tessellated exported STEP for the agents) (check 04). The within-tolerance, gouge and excess areas agree, so the effect on Acc is < 0.05 pp, but the claim should be stated precisely and one blank path used for all.
Deepest gouges are worst for MillBill but undiscussed
minor · Table S3 'Final workpiece'
MillBill has the smallest gouge area (0.54%) but the largest mean per-part maximum gouge depth, 19.40 mm (Table S3), close to the 20 mm probe cap and above every baseline (16.17–17.98 mm). In practice a deep gouge scraps a part regardless of its area. Explain where these come from (e.g. holder/fixture-free plunges, wrong setup side) and report the number of parts with gouges deeper than, say, 1 mm.
The released tool library has 79 cutters (32 flat, 8 ball, 4 chamfer) against the 75 listed in Supp. S1; the four extras (three 1 mm end mills, one 3 mm chamfer mill) are appended at the end, so it is unclear which library the experiments and the baselines used (check 15). The metric linearises arcs at 0.0005 mm in code vs ε = 0.01 mm in Supp. S1/Table S2, and stick-out uses 30 mm vs a 25 mm clamped length (check 14). None changes the conclusions, but the paper should state the commit and library used.
Single run per method; no run-to-run variance
minor · Sec. 5; Supp. S1
Each method is run once per part (Sec. 5). The 0.065 pp sampling bound covers only point sampling, not planner stochasticity; frontier agents in particular can vary a lot between runs, and the per-part catastrophic failures that drive the Astra comparison may not recur. Report at least a few repeated runs on a subset.
Unsupported or loosely worded statements
minor · Sec. 4.2; Fig. S2 caption; Sec. 4.1; Supp. S4; Table S3 caption
Sec. 4.2 says code-writing agents err 'mainly in the transformations of ±x/±y setups' without numbers. The Fig. S2 caption lists 'three of the parts on which MillBill scores lowest (64.5, 78.3, 86.5)' while p04382 (79.3) is lower than 86.5. Sec. 4.1 says 90 parts 'require' more than one setup, whereas Table S5 counts setups executed. The p02203 Astra case is called a failure of the agent in Supp. S4 but an 'evaluation failure' in the Table S3 caption; if the scorer failed, excluding the part should be justified.
Cost and hardware comparison missing; model citation imprecise
minor · Sec. 4.1 'Implementation'; Ref. [40]
MillBill runs a 27B model in FP8 on four H100 80 GB GPUs for 16.1 min per part, while the frontier agents are capped at $2; a 'locally hosted, mid-sized' framing should come with a compute/cost comparison. The citation for the model [40] is the Qwen3.8-Max launch post, not the Qwen3.8-27B-FP8 checkpoint actually used; cite the exact model card and revision.
The simulator's removal test (Eq. 3, Supp. S1) is exact: quadratic interval for d(t) <= R, closed forms for vertical/horizontal/flat moves, convex edge height c_z(t)+eta(d(t)) minimised by golden-section search; stated profiles eta for flat, ball, bull-nose and conical cutters
0 disagreements beyond the grid error bound for all four cutter types (flat, ball, bull-nose, cone; 5,000 moves each); 0 convexity violations on 422 inclined profiled moves; bull-nose profile continuous at d = R - r_c (eta = 0) and reaching r_c at d = R; golden-section bracket after 60 steps 2.9e-13. The stated formulas are correct and the convexity argument (convex d(t) composed with convex non-decreasing eta) holds.
Implemented the test exactly as written in the paper and compared with brute force (20,001-point t grid plus exact interval endpoints) on 20,000 random moves (5,000 per cutter type; inclined, vertical, horizontal) with query points within ~0.05 mm of the swept boundary; numerical convexity check by second differences
Arc chord count n = max(2, ceil(dtheta/(2 arccos(1-eps/r)))) gives sagitta <= eps = 0.01 mm; sampling error of Acc ~ 100 sqrt(p(1-p)/N) <= 0.065 pp for N = 600,000
Max sagitta 0.0100 mm, 0 violations over 10^6 arcs; formula is undefined (NaN) for r < eps/2 = 0.005 mm, harmless if guarded. 100*sqrt(0.25/600000) = 0.0646 pp <= 0.065. Monte Carlo SE of the stratified estimator: 0.060 pp at p=0.46 and 0.018 pp at p=0.98, at or below the simple bound. This bounds only point-sampling noise; it says nothing about run-to-run variability of the planners (one run per method and part).
Exact sagitta on 10^6 random arcs (r log-uniform 0.005-1000 mm); bound evaluation and Monte Carlo of the face-stratified, area-weighted estimator (2,000 reps)
Cutting-data model: n = 1000 v_c/(pi D); chip-thinning factor D/(2 sqrt(a_e(D-a_e))) for a_e < D/2 capped at 2.5; f_z = kD clamped to [0.005, 0.25]; k_c = k_c1.1 h_m^-m_c; P_c = a_p a_e v_f k_c/(60e6) kW; long tools above 5D
Paper's factor equals the standard 1/sqrt(1-(1-2a_e/D)^2) identically (sympy difference 0), equals 1 at a_e = D/2, and reaches the 2.5 cap at a_e/D = 0.042; after compensation the maximum chip thickness equals the nominal f_z. P_c units: mmmm(mm/min)*(N/mm^2)/60e6 = kW. Example (10 mm, 3 flutes, 6061, a_e = 2 mm) gives n = 9,549 rpm, P_c = 1.18 kW, plausible. All six formulas and the constants (cap 2.5, l/d 5) are present in the code. Minor paper-code difference: the code computes stick-out as overall length - 30 mm, while Supp. S1 and Table S2 state a clamped length of 25 mm.
sympy identity against the standard chip-thinning factor; unit analysis of P_c; numeric example; regex comparison with the released implementation and materials.json constants
Reach test Eq. (2) with rho_t = r_h - r_t is a necessary condition for holder clearance; dominated (rho, L) pairs can be dropped without changing the reachable set; one grey-scale dilation per pair evaluates Eq. (2) for all voxels.
Dilation vs brute force: 0 mismatches. Pruned vs full set: 0 mismatches. Necessity: 0 voxels reachable with a clear holder that Eq. (2) rejects. As expected for a necessary-only test, Eq. (2) accepts 29,447 of 571,008 voxels (5.2%) where every holder placement collides, so it over-approximates reach; the paper describes it as necessary, which matches.
numpy/scipy on 12 random 64x64 height maps (1 mm cells, blocks, walls, narrow channels) with random 6-tool sets and r_h = 20 mm: brute-force Eq. (2) vs scipy grey_dilation; pruned vs full tool set over 571,008 free voxels at 14 heights; 'true' holder clearance computed as existence of an axis position within r_t of the voxel whose r_h holder disk clears z + L_t.
The released code implements the described method and parameters: exact swept-cutter test, <=3 builds, rest scallop tau/4, fusion weights, reach thresholds, holder 40 mm / clamped 25 mm, N = 600,000, probe set {tau/4, tau/2, 3tau/4, tau}, arc sagitta eps = 0.01 mm.
12 of 14 items match exactly (N=600000; 1+2 repair rounds = 3 builds; probe ladder starts tol/4, tol/2, 3tol/4, tol; scallop sqrt(8 r tol/4); weights (0.35,0.5,0.15) and (0.6,0.1,0.3); 0.8/0.5; max(30 mm3, 0.003 part vol); 0.9 for +z; holder 40 mm; rho = r_h - r_t; temperature 0, 8192 tokens). The released kernel _removes agrees with brute force on all 59,941 queries (59 boundary queries skipped). Two minor mismatches: (1) the metric linearises arcs at ARC_TOL = 0.0005 mm (exact.py:45), not the eps = 0.01 mm stated in Supp. S1 and Table S2 (0.01 is only gcode.parse's default); the code is stricter, so scores are not inflated. (2) stick-out = overall length - 30 mm (cutting_data.py:72) vs 25 mm clamped length in Table S2. The entry point loads (python -m cam_agent --help works), but check/run fail without openai, numba, FreeCAD, an LLM server and the AAGNet weights, and the target part STEP files are not released, so no end-to-end rerun was possible.
Parsed constants from the released source (commit 4959adb) and compared them with the paper; extracted _h/_removes from exact.py (numba decorator stripped) and compared with a dense brute-force swept test on 59,941 random queries over flat, ball, bull-nose and cone cutters; tried the CLI entry point.
The paper's breakdown sums to 75, and everything else matches exactly: 17 materials, 26 rules, 37 thread specs, 55 feature-material rows, 23 guideline sections, 103 triples, 12000 rpm / 10000 mm/min / 11 kW / travel 600x400x450, and 24 MFInstSeg classes (Table S1 lists 24; the code has 25 including stock). But the released tool_library.json has 79 cutters: 32 flat (paper 30), 8 ball (7) and 4 chamfer mills (3). The 4 extras are appended after position 75 (EM1-U2, EM1-U2-L, BEM1: 1 mm; CH90-3: 3 mm), so the 1 mm cutters were probably added after the reported runs. It is unclear which library the experiments (and the baselines, who receive 'the tool library of Table S2') used. Minor: entry EM2-N3 is named '3-flute' but has flutes = 2.
Summed the paper's breakdown; parsed tool_library.json, materials.json, rules.json, kg.json, feature_material.csv, guidelines.md, machine.json and the AAGNet CLASSES list from the released repo (commit 4959adb).
Bibliography entries exist and support the claims they are cited for, in particular qwen38, cncgen (arXiv:2609.39738), designtoplan, aagnet (MFInstSeg, 24 classes) and cncnet.
All 16 arXiv ids resolve to the cited titles and first authors, including cncgen 2609.39738 (published 2026-09-30) and designtoplan 2608.24039. One flag (lee2026gcode) is a parser artefact: its sole author, Yeonseok Lee, matches. aagnet (RCIM 86:102661, 2024) and cncnet (CVPR 2024, pp. 9816-9825) match Crossref exactly. All other journal entries match Crossref titles. cadcodeverify = arXiv 2410.05340 and react = arXiv 2210.03629 exist. The opus55 and gpt6astra pages load with matching titles. The abstracts support the citing sentences: Design-to-Plan has orchestrated agents for feature recognition, drawing analysis, context fusion, knowledge retrieval, sequencing, tool selection and reports, evaluated without toolpaths; CNCGEN trains on ~50k synthetic machining flows; CNC-Net is self-supervised from a 3D model. Kienzle 1952 and Doi & Koide 1991 are not indexed and could not be verified automatically. One problem is recorded in work/ref_issues.json: qwen38 cites the Qwen3.8-Max launch post for Qwen3.8-27B-FP8.
Ran tools/check_refs.py (57 entries -> work/refs_checked.json). Queried the arXiv API by id for all 16 arXiv-cited entries and compared title and first author; looked up the aagnet and cncnet DOIs on Crossref; ran arXiv title searches for cadcodeverify and react; fetched the three model/system-card URLs; read the abstracts of designtoplan, cncgen and cncnet against the sentences that cite them.
Table 1 headline Acc_0.1 means and scored counts (MillBill 97.4 100/100; Astra 94.3 99/100; Opus 83.0 100/100; Qwen 7.9 82/100; CNC-Net 42.3 99/100), unscored parts, p05451 35.5% excess
Recomputed means: MillBill 97.395 (claimed 97.4), Astra 94.324 (94.3), Opus 83.020 (83.0), Qwen 7.863 (7.9), CNC-Net 42.269 (42.3); all within 0.04 pp. Scored counts 100/99/100/82/99 match; unscored IDs match Table S3 caption (Astra p02203, CNC-Net p04119, 18 Qwen parts). p05451 = 64.5 so 35.5% out of tolerance. Medians: MillBill 98.80 = Astra 98.80. Minor: Fig. S2 caption '(64.5, 78.3, 86.5)' omits p04382 (79.3), so 86.5 is the 4th-lowest, not among the three lowest.
Parsed per-part Table S5 from LaTeX source and recomputed means, scored counts and unscored part IDs
MillBill outperforms the best code-writing frontier agent: 97.4 vs 94.3 for GPT-6 Astra (no uncertainty reported); 97.4 vs 83.0 for Opus 5.5
Mean paired difference vs Astra +3.05 pp, 95% bootstrap CI [+0.80, +5.76], so the mean advantage is statistically supported. However, per part Astra is better on 52 parts and MillBill on 42 (5 ties; sign test p=0.35; Wilcoxon p=0.26); medians are equal (98.80 vs 98.80; median paired diff -0.10). 7 parts where Astra scores <80 contribute 263.7 of the 301.6 summed difference; dropping Astra's single worst part (p00531, 1.1%) cuts the gap to +2.13 pp and dropping its 5 worst to +0.85 pp. The headline is a mean effect driven by Astra's occasional catastrophic failures, not per-part dominance; the paper does not report this. Vs Opus the advantage is robust: +14.4 pp, CI [+10.7, +18.3], 76 wins/23 losses, sign test p=8.5e-8.
Paired analysis on Table S5 (99 parts scored for both): paired bootstrap CI (20k, seed 0), win/loss counts, sign and Wilcoxon tests, medians, trimmed means, leave-worst-out sensitivity
Internal arithmetic of Table 1, Table 2, Table S3 (Acc+gouge+excess, boundary band), Table S4 vs Table 1 and Sec. 4.4 text, p02334 example
All rows satisfy Acc+gouge+excess = 100 within rounding except Qwen agent in Table 1 (7.9+38.99+53.5 = 100.39, +0.28 pp beyond rounding); Eq. (5) allows a point to be both excess and gouged (e.g. a shifted part), so this is an undisclosed overlap rather than an error. Boundary band = within band - within tolerance for all 10 cells (within rounding). Table S4 tau=0.1 column equals Table 1; all six Sec. 4.4 tolerance numbers match Table S4. MillBill loses 8.1 pp from tau=0.1 to 0.05 vs 4.1 pp for Astra. p02334: 92.46+7.51 = 99.97 <= 100; 99.92 rounds to Table S5 99.9.
Rounding-aware table arithmetic (tolerance = half a unit in the last digit of each term)
The same scoring function evaluates MillBill and the baselines (Sec. 3.5, Sec. 4.1 Metrics); hence the uncut-stock rows of Table S3 should coincide for MillBill and the Opus agent (same 100 parts, same stocks)
For identical uncut stocks the table gives different values: excess proxy 503.28 (MillBill) vs 503.56 cm^3 (Opus), and mean per-part max gouge depth 0.00 vs 0.40 mm, i.e. the agents' blank lies inside the target on some parts while MillBill's never does. Within-tolerance (9.3), gouge area (0.00) and excess area (90.7) agree, so the effect on Acc at the uncut stage is < 0.05 pp; the difference is disclosed only in the Table S3 caption (tessellated vs analytic/mesh stock). In the released code both paths go through exact.blank_solid (exact box if the tessellation has 8 vertices, otherwise ray parity on a 0.05 mm mesh) but obtain the blank differently (session stock.mesh_raw / stock box for MillBill vs re-tessellating the exported stock.step for answers). The statement that the same function scores all systems is therefore true of the metric but not of the blank; the magnitude on headline Acc appears negligible.
Parsed Table S3 initial-stock block and compared MillBill vs Opus columns; grepped the two scoring paths in the released code for blank handling
90 of 100 parts require more than one setup; the 100 parts use 430 setups; Fig. 4b histogram of builds per setup
Table S5: 10 single-setup parts and 90 multi-setup parts (claimed 90); sum of setups 430 (claimed 430); distribution 1:10, 2:3, 3:10, 4:34, 5:10, 6:33. Fig. 4b bars 35 + 260 + 135 = 430 setups, 960 builds in total (2.23 per setup). Note the wording: Table S5 counts 'setups executed, including failed and discarded ones', while Sec. 4.1 says 90 parts 'require' more than one setup.
Counted Table S5 Setups column; extracted Fig. 4b bar labels with pdftotext
LLM ablation: reference plan (no LLM) 97.0/0.77/2.2 vs MillBill 97.4/0.54/2.1; paired diff 0.35 pp, 95% bootstrap CI [0.09, 0.68]; better on 43 parts, worse on 23; multi-setup gouge 0.46 vs 0.45, so the gouge reduction comes from the 10 single-setup parts
MillBill mean from Table S5 97.395 implies no-LLM mean 97.045, consistent with 97.0; 0.35 lies within the rounding interval [0.30, 0.50] of 97.4-97.0. Sign test 43 vs 23 (34 ties): p = 0.019, consistent with a CI excluding 0. Implied single-setup mean gouge: 1.26% with LLM (range 1.16-1.36) vs 3.65% without (3.55-3.75); the with-LLM value is below the Table S5 upper bound 4.62% (mean of 100-Acc on the 10 single-setup parts). So the whole gouge effect of the LLM rests on 10 parts (~24 pp summed), one of which (p02334, 7.51% gouge from a deburring pass) is the worked example. Per-part no-LLM scores are not released, so the bootstrap CI itself could not be recomputed.
Rounding-interval consistency, exact sign test, 90/10 decomposition of the gouge means checked against Table S5 single-setup rows
Collection of 4,294 parts = 1,396 turned (694 + 702) + 2,898 prismatic in eight kinds; released as an 'open benchmark of 4,294 GrabCAD parts paired with milling stocks'
All eight prismatic kind counts match the repo exactly (593/409/158/658/203/457/134/286, sum 2,898); turned 1,396 (=694+702; the shaft/solid-of-revolution split is not separable in the tree); total 4,294. However, each part directory contains only blank.step and part.json (4,294 each); 0 target part STEP files are released on GitHub, and the Hugging Face card also states 'The part STEP file is not included'. Since a task is defined as part + stock + material, the released 'benchmark' cannot be run without re-downloading each model from GrabCAD (21 links unverified per dataset/README).
Arithmetic; counted blank.step per kind directory in the GitHub git tree (commit 4959adb, not truncated); listed file types; checked the Hugging Face dataset card
100-part draw: 10-13 parts of each of nine stock kinds; 11 turned; materials AL 6061-T6 22, C45E/AISI 1045 21, S235JR 16, EN AW-7075 12, AISI 304 10, Ti-6Al-4V 10, POM-C 9; 'the workpiece material is the one specified by the author of the model on GrabCAD'
Counts confirmed: seed 2026, 100 parts whose IDs equal Table S5; kinds 10-13 each over 9 kinds (turned 11, sheet 13, casting 10, plate strip 10, others 11-12); materials match exactly when C45E (8) and AISI 1045 (13) are merged as in the paper (21). But the provenance statement contradicts the authors' own dataset/README.md: Supp. S2 says the material 'is the one specified by the author of the model on GrabCAD; candidates whose material is not in the knowledge base are not drawn', while the README says 'The material is the workpiece material assigned for MillBill from its knowledge base. It is not a material stated by the GrabCAD author.' The candidate filter 'workpiece material from the knowledge base' (Sec. 4.1) is then vacuous, and the materials are a design choice of the authors.
Downloaded evaluation.json and the 100 part.json files from the repo; tallied stock kinds and materials; compared IDs with Table S5; quoted both provenance statements
Six parts are longer than a 600x400x450 mm travel; on them MillBill 98.8, Astra 99.5 (5 parts; fails on the longest, 1,840 mm), Opus 82.3, CNC-Net 27.3; parts range 5.08-1,840 mm
Exactly six stocks exceed 600 mm and none fits 600x400x450 in any orientation: p02203 (1847.9 mm stock), p03553 (1507.5), p05541 (1007.0), p04710 (1007.0), p04726 (760.8), p04831 (706.7); next largest 519-561 mm. Subset means from Table S5: MillBill 98.78 (claimed 98.8), Astra 99.50 on 5 (99.5), Opus 82.30 (82.3), CNC-Net 27.30 (27.3). The longest stock (p02203, 1847.9 mm) matches the 1,840 mm part plus allowance; the smallest stock longest edge 7.08 mm (p05451) matches the 5.08 mm part plus 2 mm. Note: Supp. S4 says Astra 'fails on' p02203, while the Table S3 caption calls it an 'evaluation failure'; if the failure lies in the scorer, excluding the part (rather than imputing) is a choice that is not discussed.
Downloaded the 100 released blank.step stocks, computed bounding boxes from STEP vertex points (upper bound with circle radii), identified stocks > 600 mm, recomputed subset means from Table S5