A carefully engineered, transparently reported and largely reproducible harness whose real-robot and HiddenPhys gains hold up, but the ForceBench +17.5 pp is measured on tuned development seeds and driven by one task, and the abstract's "significantly better decisions" and "matching the expert" claims are stronger than the statistics support.
Soundness
3/4
Presentation
3/4
Contribution
3/4
Confidence
4/5
✓ 15 confirmed✕ 1 discrepancy
Summary
The paper presents ForceHarness, a tool layer that lets an API-only, frozen multimodal model (GPT-6 Astra, GPT-6.1 Sol, Claude Fable 5.2, smaller GPT-5.x models) use wrist force without demonstrations or finetuning. It has three parts: (i) force calibration from a wrist F/T sensor or from joint torques via w=(J⊤)+τext with taring (Sec. 3.2); (ii) twelve self-terminating force primitives (press, slide, search, pull, ...) that run an admittance/lead-clamped impedance loop beneath the model and return at a contact event (Sec. 3.3-3.4, Supp. A); and (iii) a physics translation layer of fixed estimators that reports quantities such as mass, CoM offset or friction with an uncertainty instead of raw traces (Sec. 3.5, Supp. B).
The authors also build HiddenPhys, seven MuJoCo tasks whose success depends on a hidden physical variable (mass, CoM, table height, latch angle, locked vs stiff door, ...), with hand-written expert controllers, a position-only controller, and Diffusion Policy / π0.5 / ForceVLA baselines trained on about 200 demonstrations per task (Sec. 4, Supp. C, G).
Headline results: on a Franka FR3 without a wrist sensor, Astra goes from 2/60 to 54/60 (Table 2); on ForceBench, 70.0% to 87.5% (Table 4), above the best trained policy (35.3%); on HiddenPhys, 87/140 to 135/140, matching the expert's 136/140 and far above learned policies (65-83/140) (Table 5). Ablations (Table 6, D2, Fig. 4c) argue that event-terminated primitives give much of the gain and that smaller models decide better from computed quantities than from raw numbers or plots.
Strengths
Every reported number we recomputed is internally consistent
Tables 2, 4, 5, 6; Supp. D (Tables D1, D2), G (Table G2), H (Tables H2, H3)
All row totals and percentages in Tables 2, 4, 5, 6, D1, D2, G2, H2 and H3 reproduce exactly from their cells (checks 01-05, 09, 11, 12). The 23 exact McNemar p-values in Table D2 reproduce, and Table 6 rates and D2 discordant pairs are jointly consistent with a unique set of integer counts. Table 4/H3 trained rows equal ForceBench Table I exactly (check 16). The expert-demonstration dataset on Hugging Face matches Table G2 to the frame (726,867 frames). This level of internal consistency across 31 pages is unusual.
Released code reproduces the non-API rows of the main benchmark
Running the released code in MuJoCo on all 7 tasks x 20 test seeds reproduced every cell of the Expert (136/140, damage 1) and Position-only (71/140, damage 6) rows of Table 5 exactly (check 15). The offline test suite passes (505 passed, 2 skipped), and the mass/CoM estimators in estimators.py match Eqs. B2, B5, B6 to the last digit on 300 random holds (check 14).
Unusually candid protocol disclosure
Sec. 5.2; Supp. C.3-C.5; Supp. H.1
The paper states things most papers omit: ForceBench tools and perception thresholds were tuned on 8 of the 10 evaluation seeds and two tasks were revised after initial runs (Sec. 5.2 "Two protocol notes"); the public evaluator omits release/clearance checks on three tasks; experts were written knowing the hidden distributions (Supp. C.3); the expert variant was selected on seeds disjoint from test seeds (Supp. C.4); and what the no-force control can still read kinematically. This makes the weaknesses below identifiable at all.
Large, statistically clear real-robot effect on a sensorless arm
Sec. 5.1, Table 2; Supp. I
Using only joint-torque-based force estimates (Supp. I), Astra rises from 2/60 to 54/60 on six contact-rich FR3 tasks (Wilson 95% CI [0.80, 0.95]); every per-task difference is significant by two-sided Fisher exact test (largest p = 0.0055 on Wipe), as claimed (check 01). Obtaining usable force primitives without a wrist F/T sensor is practically relevant.
Well-specified, stable low-level control
Sec. 3.3; Supp. A, Eqs. A1-A2, Table A2
Every primitive has pseudocode, constants per backend (Table A2) and a logged trace. The stated admittance contraction factors (0.17-0.23 real, 0.09-0.14 MuJoCo, 0.15-0.37 ForceBench), 0.2 mm/tick and 3-4 N/s ramps reproduce from Table A2, and a simulated blocked push converges without overshoot on all backends (check 08). Closing the force loop beneath a slow API model is a clean architectural idea, well argued in Sec. 1 and 3.3.
Weaknesses
ForceBench headline is measured on tuned development seeds and rests on one task
major · Abstract; Sec. 5.2, Table 4; Supp. H.1-H.2 (Table H2)
The abstract's "+17.5 percentage points on the public ForceBench suite" (Table 4) is computed on seeds 300-309, of which 8 were used to tune tools and perception thresholds and on which two tasks were revised (Sec. 5.2). Moreover, Drawer Pull (0/10 -> 10/10), a task where the no-force control cannot succeed by construction (Supp. H.2) and where the public evaluator omits the release check, accounts for 10 of Astra's net +14 and 10 of Sol's net +18 successes. Without Drawer Pull the paired tests are not significant (Astra 10 vs 6 discordant, exact McNemar p = 0.454; Sol 14 vs 6, p = 0.115; check 03). The repository (docs/forcebench.md) already contains a held-out run on seeds 320-329: 66/80 vs 50/80, p = 0.004, but again only 12 vs 6 (p = 0.24) without Drawer Pull and for Astra only (check 04). Fix: report the held-out numbers in the paper and abstract, show per-task results with and without Drawer Pull, and state explicitly that the force effect on ForceBench is concentrated on one task.
major · Abstract; Table 4 caption; Table 5; Sec. 4 (observation channels); Supp. G
On ForceBench, the trained rows are copied from the ForceBench paper (200 episodes, seeds 300-499, task sentence only), while ForceHarness rows use 10 development seeds, hand-written task details/procedural hints, suite-specific tools and calibrated cameras (Table 4 caption, Sec. 5.2; check 16). The no-force control already doubles the best trained policy, so the comparison mostly reflects the frozen-model-plus-tools setup, not force. On HiddenPhys, frozen models receive object poses as noisy text while learned policies get images (which reveal, e.g., the true Peg hole), learned rows use one training seed, and 20-seed differences between learned variants are within noise: over 50 seeds DP and DP+force are 203 vs 204/350, while the 20-seed Table 5 shows DP+force 9 lower (check 12). Fix: temper "surpassing force-aware policies" in the abstract, add CIs to Tables 4-5, and if possible evaluate ForceHarness on ForceBench's 200 seeds.
"Significantly better decisions" does not survive multiple-comparison control
major · Abstract; Sec. 5.4; Table 6; Supp. D Table D2
The abstract claims smaller models make significantly better decisions from physical quantities than raw values. This rests on L2 vs raw decisions, 18 vs 6 discordant pairs, p = 0.023 (Sec. 5.4), one of 23 paired tests in Table D2 that pool five models, three tasks and repeated seeds. All 23 p-values reproduce (check 05), but with Holm correction this comparison gives p = 0.31 (Benjamini-Hochberg 0.047); L2 vs plots on success gives Holm 0.087. Only the comparisons against no force survive Holm. L2 vs plots on decisions is p = 0.052 uncorrected. report corrected p-values or CIs on the rate differences, pre-specify the primary comparison, or phrase the result as a consistent trend rather than a significant effect.
Questions for the authors
Why are the held-out ForceBench results on seeds 320-329 (66/80 vs 50/80 in docs/forcebench.md) not in the paper, and would you replace the development-seed numbers in the abstract with them?
Excluding Drawer Pull, is there any ForceBench task where force gives a significant paired gain, on either the development or the held-out seeds?
On the real robot, what is the success rate of a control that keeps all 20-21 motion primitives (search, slide, press-turn) but suppresses force reports and force-based termination? This would separate force feedback from tool availability.
Which family of tests and which correction is the "significantly better decisions" claim meant to survive? Was L2 vs raw on decisions designated as the primary comparison before the runs?
Why does Eq. B5 use τb=0.01 N·m when Table C1 specifies a residual torque bias of 0.03 N·m per axis per episode? What empirical 2σ coverage does the CoM estimate achieve in your simulator logs?
In Supp. D.1, does "judged 15/20 correctly" for no-force Astra on Weight refer to the verdict, and how many of the 17 successes had a wrong or missing verdict?
On Wipe, 13 of 20 test seeds leave the table at nominal height. How do harness and no-force results split between seeds with and without a lowered table?
Verification
We ran 16 checks. Fifteen are confirmed: every total and percentage in Tables 2, 4, 5, 6, D1, D2, G2, H2 and H3 reproduces exactly, all claimed Fisher and McNemar p-values reproduce, the released demonstration data match Table G2, and running the released code in MuJoCo reproduces the Expert (136/140) and Position-only (71/140) rows of Table 5 cell by cell; the repository's 505 tests pass. Confirmation of the arithmetic came with context that weakens framing: the ForceBench gain is not significant without Drawer Pull (checks 03-04), the abstract's "significantly" does not survive Holm correction (05), the shift losses and the one-shot vs turn-by-turn gap are not significant (02, 09), and 50-seed scripts show learned-policy differences in Table 5 are within noise (12). One discrepancy: the CoM uncertainty uses a torque bias three times smaller than the simulator's own, under-covering at 2σ (06); it does not change Table 5. No model rows (API-only) or learned-policy rows (no checkpoints) were re-run.
✕DiscrepancySupp B Eqs. B4-B5; Supp C Table C1 (residual bias 0.03 N m per axis and episode); code forceharness/translation/estimators.py:123 vs forceharness/backends/mujoco/env.py:192-196, 317-343
No identifier, venue or URL ('Third-party evaluation report'); could not be located. It is cited (1_intro.tex:5, 2_related.tex:5) as support that GPT-6 Astra controls robots zero-shot, a claim also carried by zhang2026astra.
[14] han2026forcebench ForceBench: Benchmarking Force Integration for Robotic Manipulation (arXiv 2610.19604)
Exists and Table H3 copies its Table I exactly, but the trained rows are evaluated on 200 seeds (300-499) while the ForceHarness rows in Table 4 use 10 seeds (300-309) that were also its development seeds; the side-by-side comparison in Table 4 is therefore not on matched evaluation sets (the Table 4 caption discloses 200 vs 10 episodes per task, but not that the 10 seeds are development seeds; README/docs/forcebench.md do).
Suggestions
Replace the ForceBench development-seed numbers in the abstract and Table 4 with the held-out seeds 320-329 (already in the repository), add Sol/Fable on those seeds, and report the per-task force effect with and without Drawer Pull.
Add Wilson 95% intervals to Tables 2, 4 and 5 (Supp. C.5 already says they are used) and report rate differences with CIs rather than only p-values.
Apply a multiple-comparison correction (Holm or BH) to Table D2, or designate a single primary comparison, and rephrase "significantly better decisions" accordingly.
Add a real-robot (or at least simulated) control with the full motion-primitive set but force reporting suppressed, to separate force feedback from tool availability.
Set τb in Eq. B5 to the simulator's 0.03 N·m (or estimate it per episode), add tare noise to σ_m, and report empirical coverage of all printed uncertainties.
Report verdict accuracy separately from placement success on Weight, CoM and Lock, and score model and script rows identically on Lock.
Release per-episode model transcripts, tool calls and success logs for all API-model rows, with model version and date, so the main rows can be audited without paid API access.
Make the Wipe hidden variable active on every seed (e.g. draw the drop from a one-sided distribution without the min(0, ·) clipping) or report results separately for lowered tables.
Update the reproducibility statement (the code is public), supply an identifier for reference [27] or drop it, and fix the demo count (185/197, not 200) in Table 5.
Scope of this review
The model rows (GPT-6 Astra, GPT-6.1 Sol, Claude Fable 5.2, smaller GPT-5.x models) require paid proprietary APIs and no evaluation transcripts are released, so none of them was re-run; we checked their arithmetic and statistics only. Learned-policy rows (DP, π0.5, ForceVLA) were not retrained (no checkpoints, no GPU). Real-robot results could not be examined beyond the reported counts. ForceBench (Isaac Lab) was not run; its trained rows were checked against the ForceBench paper. The released code was run offline (tests) and in MuJoCo for the Expert and Position-only rows of Table 5. The README contains setup instructions addressed to coding agents (with safety rules for the robot); it contains no instructions aimed at reviewers and was not treated as an integrity concern.
Useful design study of how to present force to a language model
Sec. 5.4; Table 6; Fig. 4c; Supp. D Tables D1-D2
Table 6 and Table D2 compare event words, plots, raw values, signals and derived L1/L2 quantities over two model tiers with paired seeds, and Fig. 4c / Table D1 contrast one-shot Code-as-Policies with turn-by-turn use (23% -> 77% -> 91%, check 09). Independent of the headline numbers, these ablations give practitioners concrete guidance on interface design.
HiddenPhys isolates force-dependence by construction
Sec. 4, Table 3; Supp. C
Each task makes a physical variable invisible to vision (Table 3), and the task-card physics checks out (0.8 kg bar at 4 cm = 0.314 N·m; lowest Wipe table on test seeds 6.66 cm below nominal, matching "6.7 cm"; check 10). Including oracle and position-only scripts gives meaningful floors and ceilings, and a 50-seed script evaluation (Supp. C.4) is consistent with the 20-seed table (check 12).
Fix:
"Matching the expert" and "robust to shift" are point estimates at n = 20 per task
major · Abstract; Sec. 5.3, Table 5 (Shift column); Supp. C.3, C.5, D.7
135/140 vs 136/140 has Wilson 95% intervals [0.919, 0.985] vs [0.929, 0.989] (check 02): consistent with matching, but equally consistent with a several-point gap; Supp. C.5 says Wilson intervals are used but Table 5 shows none. Under shift, the paired losses of the harness are not significant (Astra 8 vs 2, exact McNemar p = 0.109; Fable 5 vs 1, p = 0.219), and over 50 seeds the expert itself loses 7.9% (190 -> 175), the same size as the 8%/5% drops presented as the harness's robustness (check 12). The expert is also built from the same primitives by the same team that authored the benchmark, so "matching the expert" partly measures whether the model invokes the right primitive. Fix: add CIs to Table 5, report the shift result as "no significant loss" rather than robustness superior to scripts, and discuss the shared-primitive design of expert and harness.
Real-robot control differs in tools, not only in force signal
major · Sec. 5.1, Table 2; Supp. I, Table I1
The Fisher tests are correct (check 01), but each cell has only 10 episodes, success is labelled by the (unblinded) operator, instructions contain procedural hints (Sec. 5.1), and the task list and tools were iterated before the final runs (Table I1). Crucially, the no-force control keeps 11 tools while ForceHarness offers 20-21 (Sec. 5.1, line "the no-force control keeps only the ten other tools and hold"), so the 3.3% -> 90.0% gap conflates force feedback with the availability of force-shaped motions (search, slide, press-turn). Fix: add a control that offers the same motion primitives with force reporting suppressed (or kinematic-only termination), and have success labelled blind or from logged criteria.
CoM uncertainty is miscalibrated relative to the paper's own noise model (discrepancy)
minor · Supp. B Eqs. B4-B5 vs Table C1; code `estimators.py:123`, `backends/mujoco/env.py:192-196`; Supp. D.7
Eqs. B4-B5 add a torque bias τb=0.01 N·m, whereas Table C1 and env.py give a residual torque bias of 0.03 N·m per axis per episode. Monte Carlo of the repository estimator under the stated simulator noise (check 06) gives 2σ coverage of 0.85-0.86 instead of 0.95, and only 65.0% of centred bars are flagged within_noise; with τb=0.03 coverage is 0.98-0.99 and 96.4% are flagged. A centred bar reads ≥ 1.1 cm 5.2% of the time, consistent with the two shift misjudgements reported in Supp. D.7. Because the decision threshold (0.12 N·m) is far from the 4 cm case, this does not threaten Table 5, but it contradicts the claim that the layer reports calibrated uncertainty. A milder version holds for mass: the printed σ_m omits tare noise (actual sd 0.036 vs printed 0.033 kg; check 07). Fix: set τb from Table C1 (or estimate it), include tare noise in σ, and report empirical coverage.
HiddenPhys success partly decouples from the physical judgement
minor · Table 3; Table 5; Supp. C task cards and "Scoring on Lock"; Supp. D.1; code `hiddenphys/tasks.py:87-93`
On Weight and CoM, success is placement in the true-class zone; the spoken verdict is not used by _ws_success/_com_success/_ls_success (check 13). This explains why no-force Astra scores 17/20 on Weight (Table 5) while Supp. D.1 says it judged only 15/20 correctly. On Lock, script rows need a correct verdict but model rows do not (Supp. C, 2_benchmark.tex "Scoring on Lock"). On Wipe, min(0, N(0, 3 cm)) leaves the table at exactly nominal height on 13 of the 20 test seeds (check 10), so the hidden-variable part of that task is often absent. Fix: report verdict accuracy alongside success, score all rows identically on Lock, and state how many seeds actually vary the hidden variable.
Turn-by-turn advantage over one-shot programs is not established
minor · Sec. 5.4 "Model in the loop"; Fig. 4c; Supp. D Table D1
Fig. 4c is used to argue for a model in the loop (91% turn-by-turn vs 77% one-shot with the force interface), but the difference is 32/35 vs 27/35, Fisher p = 0.19 (check 09); only the interface effect (8/35 -> 27/35) is clear. Fix: more seeds or a softer conclusion.
Small numerical and descriptive inconsistencies
minor · Supp. A "Force from lead"; Table 5; Table G1; Eq. 5; Supp. B Eq. B3
(a) Supp. A states real stiffness K = 0.75-1 N/mm, but "25 mm lead ≈ 18 N" and "15 mm reads 10-11 N" imply K ≈ 0.67-0.73 N/mm, and the 66 ms measured tick gives λ = 0.22-0.30, not 0.17-0.23 (check 08). (b) Table 5 lists 200 demonstrations for every learned row, but Peg has 185 and Latch 197 (Table G1, released data; check 11). (c) Eq. B3 uses the standard error of mean |F_t| while code uses the std of signed F_t (estimators.py:242), and Eq. 5's σ_μ ignores covariance of F_t and F_n (check 14). (d) The Weight zone tolerance is a square ±8 cm in code but "within 8 cm of the centre" in text.
Reproducibility of the model rows depends on proprietary APIs; some statements are out of date
minor · Reproducibility statement; Sec. 1 and 2 (ref. [27]); Supp. F
All headline rows use GPT-6 Astra, GPT-6.1 Sol or Claude Fable 5.2 through paid APIs; no evaluation logs are released (the HF dataset holds only expert demonstrations), so no model row could be independently re-run. The reproducibility statement says code "will be released upon publication" although the repository is public. Reference [27] (robocurve2026astra), cited as support for zero-shot robot control with Astra, has no identifier and could not be located. Fix: release per-episode model transcripts and success logs, pin model versions/dates, and update the statement.
Novelty of the physics translation layer relative to prior LLM-with-force work
minor · Sec. 2 (LLMs with force); Sec. 3.5
Reporting sensed physical properties to a language model as text is close in spirit to MATCHA and related work cited in Sec. 2. The paper's distinctive contribution is the integration (beneath-model force regulation + calibrated estimators + evaluation), which is valuable but should be stated as such, with a direct comparison to a raw-reading or force-code baseline from that line of work on HiddenPhys.
How many times were the real-robot tasks, tools and instructions revised before the final 10-episode runs, and were any of those runs on the same objects/initial conditions?
Task-card physics: 0.8 kg bar with 4 cm CoM offset ~0.31 N·m (2.5 cm under shift); 0.1 N·m residual ~1.3 cm; Wipe table min(0, N(0, 3 cm)), lowest top 6.7 cm below nominal, "up to about 6 cm low"; shift up to 3 cm lower
0.8x9.81x0.04 = 0.314 N·m (shift 0.196); 0.1/(0.8x9.81) = 1.27 cm; 0.12 N·m threshold < 0.157 (half). The benchmark task wipe_hard uses table_height_std 0.03, matching the card; my earlier planning note (std 0.012) referred to the unused base WIPE task. The sim table_offset matches the replicated draw exactly on 6/6 builds. Lowest nominal drop on test seeds = 6.66 cm (seed 9117), matching "6.7 cm"; 1/20 seeds is below 6 cm. Shift (mean -3 cm) lowest 9.66 cm. Observation: because of min(0, .), 13/20 Table 5 test seeds (29/50) have the table exactly at nominal height, so Wipe force dependence comes mainly from the 5-15 N pressure band rather than from table uncertainty; the shift moves 84% of tables below nominal. Shift CoM margin over the 0.12 N·m threshold falls from 0.194 to 0.076 N·m.
Closed-form arithmetic; replicated the table draw (first np.random.normal after np.random.seed(seed)) for seeds 9100-9149; confirmed the replication against the real robosuite 1.5.1/MuJoCo 3.2.7 simulator built from the released code for seeds 9100-9102 (nominal and shift)
All seven rows match the released dataset exactly (attempted, released, frames, longest episode from index.jsonl), totals 1500/1423/726,867 match the LeRobot meta, and every horizon equals floor(1.5 x longest). Minor: Table 5 lists 200 demos for every learned row, but Peg has 185 and Latch 197 saved episodes (Table G1).
Re-added Table G2 rows; downloaded released metadata (raw/attempts.json, raw/<task>/index.jsonl, meta/info.json) and compared per task; recomputed floor(1.5 x longest)
Scripted references over 50 seeds: expert 337/350 (Weight 50, CoM 48, Wipe 49, Latch 47) and DP 203/350 vs DP+F 204/350; shift over 50 seeds expert 190->175, position-only 65->59, DP 128->107 and 151->117
Implied expert Peg = 190-50-48-49 = 43 and Stack+Lock = 337-237 = 100, i.e. both 50/50, the maximum. Implied position-only Peg = 15, consistent with 31 timeouts (<= 19). Every expert, position-only and DP cell satisfies the subset constraint; 20-seed shift sums 77 and 25 match Table 5. Context: over 50 seeds DP and DP+force are equal (203 vs 204/350, +0.3 pp), while the 20-seed Table 5 shows DP+force 9/140 lower; 20-seed learned-policy differences are within noise. Over 50 seeds the expert loses 7.9% under shift (190->175), the same size as the 8%/5% FH drops presented as robustness, and DP loses 16.4%.
Derived the unstated cells from the stated sums; checked the subset constraint n20 <= n50 <= n20+30 for every cell (Table 5 seeds 9100-9119 are a subset of 9100-9149); Wilson 95% intervals; recomputed relative drops
No-force Astra scores 17/20 on Weight (Table 5) while Supp D.1 says it judged 15/20 correctly
_ws_success, _com_success and _ls_success never use the verdict: success is placement in the zone of the true class (resting <6 cm above table, |dx|,|dy|<8 cm, fingers open, no contact), matching the Weight task card. So Astra no-force Weight success 17/20 can exceed correct verdicts 15/20 by 2 without contradiction (CoM 10 vs 10). Interpretive point for readers: HiddenPhys success on Weight/CoM measures correct placement, not the spoken judgement, and on Lock model rows are scored without the verdict while script rows need it (disclosed at 2_benchmark.tex:106). The square 8x8 cm tolerance in code is described as within 8 cm of the zone centre in the paper (minor).
AST inspection of the three success functions (docstrings removed) for any use of the verdict; parsed Table 5 rows and the D.1 sentence
The released code implements the paper estimators and primitives and its offline tests pass
pytest: 505 passed, 2 skipped (exit 0, 233 s). Mass, sigma_m, CoM offset r, sigma_r and the within_noise flag agree exactly with Eqs. B2/B5/B6 (max diff 0 after rounding; 0 flag mismatches on 300 holds). Pull sigma = s/sqrt(n)+sigma_b, stiffness sigma_k, path radius rms+5 mm and sigma_tau = sqrt((sx^2+sy^2)/n)+0.01 are in code as written. Minor: Eq. B3 uses the standard error of mean |F_t|, the code uses std of signed F_t (estimators.py:242), identical only if F_t keeps its sign. The tau_b = 0.01 N·m in code and paper is the miscalibration source flagged in check 06.
Ran the repo offline test suite in a /tmp venv; compared est_payload_and_com with an independent implementation of Eqs. B2, B5, B6 and the within_noise flag on 300 random holds; located the other sigma formulas in source
The hand-written expert scores 136/140 and the position-only controller 71/140 on the HiddenPhys test seeds 9100-9119
Exact reproduction of every cell. Expert 20/19/20/20/18/19/20 = 136/140, damage 1. Position-only 10/10/0/17/5/13/16 = 71/140, damage 6. Lock: expert 20/20 correct verdicts, position-only N3 16/20. Peg position-only hits max_sim_time in 13/20, consistent with "runs out of time" (Supp C.4). These are the only Table 5 rows reproducible without API access or trained checkpoints; the model rows and learned-policy rows were not re-run.
Ran the released code in MuJoCo (robosuite 1.5.1, mujoco 3.2.7, MUJOCO_GL=disable, /tmp venv) on all 7 tasks x 2 rows x 20 test seeds (280 episodes) with the repo configs, n_episodes set to 20; compared per-task successes and handle damage with Table 5
References are real and correctly cited; trained ForceBench rows in Table 4/H3 are copied from the ForceBench paper (han2026forcebench, arXiv 2610.19604)
45/46 references resolve to the cited work. check_refs alone mis-resolved three (pi05 -> pi0, ForceVLA2 -> Force Policy, Hogan Part I -> Part II); title search finds the correct items (arXiv 2504.16054, 2603.15169, doi 10.1115/1.3140702), along with CaP-X 2603.22435, Never Too Late for Force 2607.14236 and OmniVIC 2510.17150. Unlocatable: robocurve2026astra (third-party report, no identifier). All 10 H3 rows and all 6 Table 4 trained rows equal ForceBench Table I exactly. ForceBench evaluates on seeds 300-499 (200 episodes); ForceHarness rows use 10 development seeds 300-309, so Table 4 compares unmatched evaluation sets. The zhang2026astra abstract supports LLM-as-policy without task-specific finetuning (RoboDojo, 22.48% success). Issues are in work/ref_issues.json.
tools/check_refs.py; title similarity of each bbl title against Crossref/arXiv matches (threshold 0.85); arXiv/Crossref title search for the rest; parsed ForceBench Table I from the arXiv HTML and compared numerically with H3 and Table 4; read ForceBench evaluation seeds; abstract spot-check of zhang2026astra
Real FR3 without wrist sensor: Astra 2/60 (3.3%) -> 54/60 (90.0%), Sol 47/60; for Astra every task differs at p<0.01 by Fisher exact test
Totals 2/60, 54/60, 47/60 and 3.3%/90.0% reproduced exactly. Per-task two-sided Fisher p: Wipe 0.0055, Screw 0.00012, Eggplant 0.0011, USB 0.0007, Bottles/Soft-hard 1.1e-5; all < 0.01 (Wipe 1/10 vs 8/10 is the weakest). Wilson 95% CI for 54/60: [0.80, 0.95]. Note n=10 per cell and operator-labelled, unblinded success are not addressed by the test.
Re-added per-task cells; two-sided Fisher exact per task (scipy); Wilson 95% intervals
HiddenPhys: Astra 87/140 (62.1%) -> 135/140 (96.4%, +34.3 pp), matching expert 136/140; learned 65-83/140; under shift FH drops 8%/5% vs 16-19% (no force) and 17-25% (learned, except DP images-only 5%)
All 13 row totals and all 13 in-distribution shift sums match exactly; 62.1%/96.4%/+34.3 pp reproduced. Drops: Astra+FH 8.0%, Fable+FH 5.3%, no force 15.9%/18.8%, learned 16.7-25.0%, DP images-only 4.5%, expert 11.7% - all consistent with the text after rounding. Context: Wilson 95% CIs 135/140 [0.919,0.985] vs 136/140 [0.929,0.989] overlap almost fully, so "matching" is supported but cannot be resolved at n=20/task; the paired shift losses are not significant (Astra 8 vs 2, exact McNemar p=0.109; Fable 5 vs 1, p=0.219), so "robust to shift" rests on point estimates.
Re-added every per-task cell; checked Weight+CoM+Wipe+Peg in-distribution sums against left side of Shift column; recomputed relative drops; Wilson 95% CIs; exact McNemar on paired shift counts
ForceBench: Astra 70.0 -> 87.5%, Sol 65.0 -> 87.5%, Fable+FH 75.0%; best trained 35.31%; paired exact McNemar p=0.009 (Astra) and 0.001 (Sol), mainly on Drawer Pull
All row means match (tolerance 0.006). Table 4 and Table H2 agree cell by cell and pairs are internally consistent. Exact McNemar: Astra 20/6 p=0.0094 (claimed 0.009), Sol 24/6 p=0.0014 (claimed 0.001). Sensitivity: Drawer Pull gives 10 of Astra net +14 and 10 of Sol net +18; without Drawer Pull the paired tests are not significant (Astra 10/6 p=0.454; Sol 14/6 p=0.115). The +17.5 pp headline therefore rests mostly on one task where the no-force control cannot succeed by construction (Supp H.2) and where the public evaluator omits the release check.
Recomputed all 15 row means; cross-checked Table 4 percentages against Table H2 counts and per-task discordant-pair consistency; exact McNemar (binomial) with and without Drawer Pull
ForceBench numbers in the paper are on development seeds 300-309 (tools tuned on 300-307; two tasks revised after runs); the repository reports a held-out test on seeds 320-329: Astra 66/80 (82.5%) vs 50/80 (62.5%), pairs 22/6, p=0.004; 12/6 (p=0.24) without Drawer Pull
Held-out numbers reproduce exactly from the per-task table: 66/80 (Wilson 72.7-89.3%), 50/80 (51.5-72.3%), pairs 22/6 p=0.0037, without Drawer Pull 12/6 p=0.238. The held-out test supports a force effect (gap 20.0 pp vs 17.5 pp on dev seeds) but both conditions drop 5-7.5 pp, and the gain again comes mainly from Drawer Pull; it covers Astra only. This more rigorous result is not in the paper, whose headline +17.5 pp is on tuned seeds.
Parsed the held-out per-task table from docs/forcebench.md; recomputed totals, Wilson CIs, discordant-pair consistency and exact McNemar with and without Drawer Pull
Smaller models make significantly better decisions with physical quantities than raw force (0.69 -> 0.85, McNemar p=0.023); L2 beats plots on success (p=0.005); event words lift success 0.63->0.77 (Sol), 0.18->0.54 (smaller)
Table 6 and Table D2 are mutually consistent with a unique set of integer counts per column (e.g. smaller decisions nf/events/plot/raw/signals/L1/L2 = 43/48/53/52/64/63/64 of 75). All 23 p-values reproduce (e.g. L2 vs raw decisions 18/6 p=0.0227; L2 vs plot success 28/10 p=0.0051). Arithmetic is correct, but the abstract word "significantly" is fragile: across the 23 tests, L2 vs raw decisions has Holm-adjusted p=0.31 and BH-adjusted p=0.047; L2 vs plot success Holm 0.087, BH 0.017. Only comparisons against no force survive Holm.
Integer search for counts consistent with both Table 6 rates and every Table D2 discordant-pair difference; recomputed all 23 exact McNemar p-values; Holm and Benjamini-Hochberg over the 23 tests
The CoM offset is printed as r +- sigma_r with sigma_tau = sqrt((s_x^2+s_y^2)/n) + tau_b, tau_b = 0.01 N m, and a centred bar is flagged within_noise when |r| < 2 sigma_r
With tau_b = 0.01 the printed sigma_r is too small for the paper own noise model: 2-sigma coverage 0.852 (2.5 cm) and 0.864 (4 cm) vs nominal 0.95; 1-sigma 0.53-0.55 vs 0.68. Only 65.0% of centred bars are flagged within_noise (mean spurious reading 0.56 cm). Using the Table C1 value tau_b = 0.03 restores 2-sigma coverage to 0.98-0.99 and flags 96.4% of centred bars. P(centred bar reads >= 1.1 cm) = 5.2%, consistent with the two shift misjudgements in Supp D.7. Decisions on the 4 cm/2.5 cm cases are rarely affected (expert threshold 0.12 N m), so this is an internal inconsistency in the claimed calibration rather than a threat to Table 5. Supp B does state the printed sigma covers measurement noise only. Limitation: arm dynamics during the hold are not simulated.
Monte Carlo (4000 runs per case) of the repository estimator est_payload_and_com, loaded by file path, on synthetic 20-sample lift windows drawn from the simulator noise model stated in Table C1 and env.py (0.05 N m per-tick torque noise, 0.03 N m per-episode bias, 10-tick tare); 0.8 kg bar at 0, 2.5, 4 cm; compared with tau_b = 0.03
Mass m = |mean Fz|/g with sigma_m = sqrt(s_z^2/n + sigma_b^2)/g; error mean 0.004 kg, sd 0.03 kg, matching printed sigma; 0.375 kg threshold separates 0.15/0.60 kg and 0.30/0.45 kg under shift
Closed-form printed sigma_m = 0.0326 kg (paper ~0.03). Under the stated noise model the actual error sd is 0.036 kg because the 10-tick tare adds noise that sigma_m omits; 1-sigma coverage 0.62-0.63 (slightly under nominal 0.68). Within the one-significant-figure tolerance used. Nominal classes are 6.2 sigma from the threshold (no errors); shifted classes are 2.1 sigma away, giving 1.9-2.4% misclassification per episode (about 0.4 expected errors per 20 episodes). Paper empirical mean error 0.004 kg is not reproducible without simulator logs.
Closed-form sigma_m from stated constants; Monte Carlo (5000 runs per mass) of the repository estimator with the simulator noise model; misclassification rate at 0.375 kg
Admittance contraction lambda = K k_f dt for push: 0.17-0.23 (real), 0.09-0.14 (MuJoCo), 0.15-0.37 (ForceBench), no oscillation; real K 0.75-1 N/mm, 8 mm lead <= ~8 N, 25 mm ~18 N; 0.2 mm per tick; 3-4 N/s
lambda: real 0.169-0.225, MuJoCo 0.090-0.135, ForceBench 0.150-0.369, all matching to two decimals; 0.2 mm/tick and 3-4 N/s reproduced. Simulated blocked push converges with zero overshoot for all backends (overshoot appears only for lambda > 1). Caveats: with the measured 66 ms real tick, lambda is 0.22-0.30 and the step 0.26 mm (still stable). Minor internal inconsistency: a 15 mm lead reading 10-11 N implies K = 0.67-0.73 N/mm, below the stated 0.75-1 N/mm; "8 mm <= 8 N" uses K = 1 while "25 mm about 18 N" uses K about 0.72 (K range gives 18.8-25 N).
Recomputed lambda from Table A2 constants (k_f = 0.0045, confirmed in code as 3 x 0.0015; MuJoCo push uses kp_contact = 40); KL bounds and ramp rates; simulated the discrete admittance law against a blocked spring
Code-as-Policies: one-shot programs 23% without the force interface, 77% with it; turn-by-turn 91%
Column totals 8, 27, 20, 32, 32 of 35 reproduce; 22.9%, 77.1%, 91.4% match the text 23/77/91. One-shot none vs force p=1.1e-5; but one-shot force (27/35) vs turn-by-turn force (32/35) is not significant (Fisher p=0.19), so the claim that turn-by-turn feedback adds beyond the interface rests on 5 seeds per task (n=35).
Re-added per-task cells of Table D1; recomputed percentages; unpaired Fisher exact tests between variants