An elegant idea whose Epilepsy result reproduces, but the HAR few-label headline is contradicted by the paper's own matched 3-seed table (74.60 vs 65.73 at 1%), the released code does not implement Eq. 3 or the stated patch configuration, and the abstention and deletion claims are weaker than presented.
Soundness
2/4
Presentation
2/4
Contribution
2/4
Confidence
4/5
✓ 10 confirmed✕ 12 discrepancy◐ 2 inconclusive
Summary
ConceptTime is an interpretable time-series classifier built on a frozen autoregressive Gaussian density model. The model's per-step predictive surprise does two jobs. A length-constrained dynamic program uses it to place K patch boundaries, and each patch is then described by a hand-specified (2C+13)-dimensional signature (predictive moments, residual morphology and surprise trajectory). A diagonal GMM over the signatures forms a label-free concept vocabulary. Patches are soft-assigned to concepts, and a small supervised head classifies the resulting K×M concept tensor. The distance to the nearest concept gives a fidelity score F(, which the paper uses for abstention and OOD detection.
Strengths
Simple, unifying idea
Sec. 1, Sec. 3.2-3.4, Eq. 2, Eq. 4
One probabilistic forecaster both places the boundaries (surprise-maximising DP) and describes the patches (predictive moments, residual morphology, surprise trajectory). The signatures are hand-specified and inspectable, which is a clean way to ground concepts without annotations or language models.
Released code and checkpoint; Epilepsy headline reproduces
Table 1, Table 4; inputs/code/src/evaluate.py
Running the released evaluate.py on the shipped Epilepsy checkpoint gives 97.78 / 97.52 / 98.30 at 1% / 5% / full labels, against the claimed 97.91 / 98.01 / 98.39. All three are within one reported seed SD (check 01).
Correct and efficient segmentation algorithm
Sec. 3.3, Eq. 4; src/patcher.py `dp_segment`
The monotone-deque DP returned the optimal valid segmentation on 400/400 brute-force test instances, and its run time grows sub-linearly in T over T = 500-4000 (check 12).
Careful bookkeeping in many reported figures
Table 2, Table 6, Sec. 3.4, Appendix C-E
All six density-model parameter counts in Table 6 are exact. The signature dimension matches the code. Every Table 2 mean, win count and per-direction difference recomputes to two decimals, and all appendix differences (Tables 5, 6, 8, FD OOD) are arithmetically correct (checks 07, 09, 10, 18).
Weaknesses
HAR few-label headline contradicted by the paper's own matched protocol
major · Table 1, Table 4 vs Table 7 (tex:1102) and Table 8 (tex:1129); abstract
Table 1 reports HAR 74.60 ± 1.76 (1%) and 79.60 ± 1.31 (5%). Table 7 reports CT-FullU, which also fits the density model and vocabulary on all training inputs, at 65.73 ± 0.45 and 68.86 ± 0.31 over seeds 2021-2023. The gaps are +8.87 pp (Welch p = 0.0094) and +10.74 pp (p = 0.0034). Only the single seed-2026 split (Table 8: 74.63 / 79.88) matches Table 1. Under the matched protocol, ConceptTime on HAR trails TS-TCC-SSL (72.51 / 80.55), MiniRocket (86.34 / 94.62) and TSLANet (85.86 / 91.11). The best CT variant at 1% (69.16) is also below the Table 1 TOTEM number (73.86), so the 'beats every interpretable baseline' claim is not established on HAR at low budgets. The text says only 'MiniRocket leads'. Fix: report Table 1 under the matched multi-seed protocol (same seeds and subsets for all methods), or explain exactly how the Table 1 splits differ (check 03).
Released code does not implement the described method
major · Eq. 3 (tex:314-318), Sec. 4.1 (tex:355-357), Alg. 2; src/concept_space.py, src/patcher.py:72, src/evaluate.py, src/train_pipeline.py
Eq. 3 specifies Mahalanobis distance with temperature τ. The code (ConceptSpace.soft_assign) uses Euclidean distance with , and on Epilepsy test patches the two choices pick the same nearest prototype only 42.91% of the time. returns a hard-coded {K: 8, L_min: 16, L_max: 32} for every dataset, whereas the paper states with K chosen on validation. This configuration is infeasible for HAR (T = 127), Sleep-EDF, FD and several UEA sets: the DP returns nothing, and the patcher falls back to score-independent halving ([63, 32, 16, 8, 4, 2, 1, 1] on HAR), while raises ValueError for HAR and Sleep-EDF. also omits , which training uses. Further mismatches: the checkpoint has = 0.01 (paper 0.25) and was saved at epoch 19 (paper 50); an undocumented learned ChannelMixer precedes the density model; and the README training command trains the neural ConceptEncoder path. As released, the code cannot regenerate the HAR, Sleep, UEA or FD results as described. Fix: release the exact configurations used for each table and align Eq. 3 and Alg. 2 with the code (checks 11, 12b).
Questions for the authors
How were the Table 1 HAR few-label numbers (74.60 / 79.60) obtained, and why do they differ from CT-FullU in Table 7 (65.73 / 68.86) when both fit the density model and vocabulary on all training inputs? Do Table 1 baselines and ConceptTime share the same labeled subsets and seeds?
Which distance (Mahalanobis per Eq. 3 or Euclidean per the code and Alg. 2) and which temperature produced the reported results? Can you report Table 1 under both?
Which (K, L_min, L_max) values were used for HAR, Sleep-EDF, each UEA set and FD, given that the released get_patch_config is infeasible for most of them?
Which classifier produced Fig. 5 (0%-deletion accuracy ≈0.95 on Epilepsy and ≈0.57 on HAR), and with what K?
How does fidelity compare with the density model's own sequence NLL on the synthetic OOD tasks of Fig. 4?
Why does the default configuration give different accuracies across the three Table 3 sweeps, and why do none match Table 1?
What is the accuracy of ConceptTime with the sparse linear head, which would make the concept → label map interpretable?
Verification
We ran or recomputed 24 checks with scripts in work/verify/: 10 confirmed, 12 discrepancies, 2 inconclusive. The released Epilepsy checkpoint reproduces the headline within one seed SD (97.78 / 97.52 / 98.30 vs 97.91 / 98.01 / 98.39). The DP is optimal on 400/400 instances. Parameter counts, signature dimensions and all Table 2 and appendix arithmetic are exact. The key discrepancies are as follows. HAR few-label Table 1 numbers exceed the paper's own matched 3-seed CT-FullU numbers by 8.87 / 10.74 pp. The code uses Euclidean τ = 1 assignment (42.91% agreement with Eq. 3's Mahalanobis) and a hard-coded patch configuration that is infeasible for HAR, Sleep and FD. Fig. 5 was produced with a classifier far weaker than Table 1's, and on the released model fidelity-guided deletion is not better than random (0.940 vs 0.945). The classifier has 102,850 parameters, not ~10^3-10^4. HAR, Sleep, UEA and FD checkpoints were not evaluated, and baselines were not rerun.
Bib title 'EntroPE: Entropy-Guided Dynamic Patch Encoder for Time Series Forecasting' differs from the arXiv record (v3) 'Entropy Guided Dynamic Patch Segmentation for Time Series Transformers'. This is the authors' own prior work and is used as a forecasting model turned classification baseline (Table 1) and as the 'segmentation replacement' ablation (tex:425-430).
wickramasinghe2025smart (arXiv:2512.05402)
Cited for 'industrial telemetry' time-series classifiers (tex:168), but the work is about Bitcoin mining-hardware ROI prediction; weak support for the sentence.
sprang2025enforcing (arXiv:2410.06070)
Key says 2025 and the text says 'CKA-aligned concepts for forecasting'; the arXiv record is from 2024-10-08 (bib year 2024 is correct, only the key is off). Cosmetic.
jeon2025locality
Key says 2025, but the bib entry gives UniReps workshop 2024. Cosmetic inconsistency.
Suggestions
Re-run Table 1 for all methods under one matched multi-seed protocol (identical labeled subsets and seeds), and report per-seed numbers. Report HAR from that protocol.
Make the code match the paper (or vice versa): Mahalanobis vs Euclidean assignment, τ, per-dataset (K, L_min, L_max), λ_cal and epochs. Ship per-dataset config files and the exact commands for every table.
Pass L_max in evaluate.py, and make the patcher fail loudly instead of silently halving when the DP is infeasible.
Add density-model NLL and feature-space Mahalanobis baselines to the OOD study. Report calibration (ECE, reliability diagrams) if 'calibrated abstention' is kept as a claim.
Recompute Fig. 5 with the Table 1 classifiers and the stated K, include a random-ordering band over several seeds, and report the replacement value used by Alg. 4.
Run a single consistent ablation grid (one value per configuration), and replace the EntroPE comparison with a swap of only the segmenter inside ConceptTime.
Report per-dataset UEA results and the actual number of labeled examples per dataset and budget, for ConceptTime and baselines.
Report the sparse linear head as the interpretable variant, or show how decisions of the transformer head can be explained in terms of concepts.
Correct the text claims: the margin '1.5 points' (actual 0.74), 'trails by 2-8 points' (HAR 8.40), the EntroPE range '4.5-8.5' (actual 3.03-10.76), and '~10^3-10^4 parameters'.
Ethics and integrity
No ethical or integrity concerns requiring action. LLM use for language polishing is disclosed. No prompt-injection or hidden instructions were found in the source or code. EntroPE (Table 1 baseline and segmentation ablation) is the authors' own prior work, which should be stated explicitly. The numerical inconsistencies documented above (Table 1 vs Table 7, Fig. 5 vs Table 1, Panel A vs Panel B of Table 2) are of a kind that protocol or bookkeeping differences can explain. We do not allege intent.
Scope of this review
We evaluated only the released Epilepsy data and checkpoint (rerun on CPU). The HAR, Sleep-EDF, UEA and FD checkpoints, hosted on Hugging Face, were not evaluated because the earlier verification step was OOM-killed at the 8 GiB limit. So Table 1 numbers for those datasets, Fig. 4 on HAR and the Table 2 transfer results are checked only for internal consistency. Baselines were not rerun, and GradientSHAP/TimeX/TimeX++ deletion curves were not reproduced (a grad×input baseline was used instead). Fig. 5 values were read from figure pixels (about ±0.01). No training from scratch was attempted.
The paper claims that ConceptTime beats every interpretable baseline on UCI-HAR, Epilepsy, Sleep-EDF and a 10-dataset UEA average at 1% / 5% / full labels, and that it is competitive with black boxes (97.91% on Epilepsy with 1% labels). It also claims that F(x) detects OOD inputs and gives competitive deletion faithfulness, and that the method transfers across the four FD bearing domains.
2
C
+
13
Breadth and candid appendices
Appendix C.1-C.4, E.1-E.3 (Tables 4-9)
The paper evaluates 3 core datasets, a UEA-10 average and 12 FD transfer directions. The appendices report evidence against the method: matched-access results (Table 7), fidelity E-AURC about 9× worse than softmax (Table 9), FD FPR95 0.719, and density-size differences within seed noise. This candour makes a careful assessment possible.
Strong label efficiency on Epilepsy
Table 1, Table 4, Table 7
97.91 ± 0.96 at 1% labels beats every baseline in Table 1, including TSLANet (95.41 ± 1.19; Welch p = 0.0497 with n = 3). The matched protocol still gives 96.64 ± 0.41 (Table 7).
τ=1
get_patch_config
(Lmin,Lmax)=(8,40)
train_pipeline.py
evaluate.py
L_max
λcal
Abstention and OOD claims overstated
major · Sec. 4.3, Fig. 4, Appendix E.1-E.2 (Table 9), contribution 3 (tex:208)
The paper's own Table 9 gives fidelity E-AURC 0.01032 against 0.00117 for max-softmax (8.82× worse). Our rerun on the released model reproduces this ordering (0.00720 vs 0.00113), so for in-distribution abstention, fidelity is clearly inferior to the classifier's softmax. 'Calibrated abstention' is claimed but calibration (ECE, reliability) is never measured. For synthetic OOD, the obvious baseline is missing: on Epilepsy, the frozen density model's own NLL already reaches AUROC 0.998-1.000, matching fidelity (0.997-1.000). Softmax there is not at chance (0.523-0.827). On the realistic FD shift, fidelity AUROC is 0.666 with FPR95 0.719. Fix: add density-NLL and Mahalanobis-feature baselines, measure calibration, and frame fidelity as a complementary OOD signal rather than an abstention mechanism (checks 13, 13b, 14).
Deletion study does not use the main classifier and is not reproduced
major · Sec. 4.3, Fig. 5 (tex:526-539), Alg. 4 (tex:1297)
At 0% deletion, the Fig. 5 curves start at about 0.948 (Epilepsy) and 0.571 (HAR), well below Table 1 (98.39, 88.91). The HAR x-axis has 4 points, implying K = 3 rather than the stated K = 8. So the deletion results come from a different, weaker model. Running Alg. 4 on the released Epilepsy classifier gives fidelity AUC 0.940 vs random 0.945 and grad×input 0.900. Fidelity ordering is not better than random there, while the paper reports 0.804 vs 0.836. Fix: run the deletion study on the Table 1 models, state K and the replacement value, and add more seeds (checks 15, 15b).
Ablations are inconsistent and do not single out the proposed design
major · Table 3 (tex:552-594); Sec. 4.2 ablation paragraph (tex:425-430)
The default configuration (Surp.f signature, M = 32, surprise boundary) appears in all three Table 3 sweeps with different accuracies: HAR 85.7 / 85.7 / 82.5, Sleep 74.8 / 74.0 / 74.5. None matches Table 1 (HAR 88.91, Sleep 78.15). Predictive moments alone beat the proposed surprise signature on HAR (87.7 vs 85.7), and 'Full' beats it on Sleep (78.3 vs 74.8). This weakens the claim that the surprise-based description is what matters. The 'replace DP with EntroPE' ablation compares against a different end-to-end model (the authors' own forecaster), not a segmentation swap inside ConceptTime. Its stated range '4.5-8.5 points across benchmarks' is actually 3.03-10.76, and EntroPE wins on Sleep at 1% labels (by 0.74). Fix: run a single consistent ablation grid, swap only the segmenter, and report seeds (checks 05, 06).
Classifier head is neither small nor interpretable
minor · Sec. 3.6 (tex:328), Sec. 4.1; src/classifier.py
Sec. 3.6 claims ~103-104 parameters. The released TransformerClassifier has 101,314-104,410 parameters, and 102,850 in every Epilepsy checkpoint. More importantly, the concept → label map is a 2-layer transformer, so the explanation stops at the bottleneck; how concepts combine into a decision is not interpretable. Fix: correct the count, and report the sparse linear head (present in the code, 130-6,682 parameters) as the interpretable variant with its accuracy (check 08).
Inconsistent rows in the transfer table
minor · Table 2 (tex:439-508)
Panel A 'Source-Mθ, 5%' and Panel B 'Source-Mθ, source vocab.' describe the same configuration, yet they differ in 9 of 12 directions (e.g. A→C 75.84 vs 87.70; B→D 98.53 vs 94.27). The Panel B 'Target-Mθ, target vocab.' row is identical for every source of a given target, so it involves no transfer and should be labelled as an in-domain reference (check 07b).
Label budgets on UEA are not 1% / 5%
minor · Table 1 (UEA columns); src/train_pipeline.py `stratified_subset`
stratified_subset keeps max(1, round(n_c·f)) examples per class. On small UEA sets, '1%' therefore means 17.3% (Handwriting, 26/150), 6.7% (UWave, 8/120) or 3.3% (JapaneseVowels), and '1%' and '5%' coincide on Handwriting and UWave. Per-dataset UEA results are never shown (only a 10-dataset average), and it is not stated whether baselines received the same subsets (check 17).
Text overstates Table 1 margins and significance
minor · Sec. 4.2 (tex:420-422), Table 1, Table 4
The smallest margin over an interpretable baseline is 0.74 (HAR 1%, vs TOTEM 73.86), not '1.5 points'. The HAR full-label gap to the best black box is 8.40, outside the stated '2-8'. Results use n = 3 seeds with no tests. Several 'higher mean' statements are not significant (Epilepsy 5% vs TSLANet p = 0.058; UEA 5% p = 0.84), and several baselines are non-monotone in label budget (e.g. PatchTST Epilepsy 96.67 at 5% vs 93.65 full), which suggests under-tuned baselines (checks 04, 16).
Overclaims about the signal-to-concept path
minor · Sec. 3.4 (tex:297), Eq. 3, Eq. 5
'No neural component sits between the signal and ϕj' (tex:297) and 'non-parametric' do not hold: ϕj is computed from μt,σt produced by a 4-layer transformer and a learned channel mixer. The method may still avoid leakage from labels, which is the real point, and the wording should say so. The symbol τ is used both for the assignment temperature (Eq. 3) and for the median-distance scale (Eq. 5).
Released Epilepsy run vs reported means
minor · Table 1/4; src/evaluate.py:6; checkpoints/Epilepsy
The released artifact stores single-run accuracies 97.91 / 98.04 / 98.00. The 1% value equals the reported 3-seed mean exactly, and the full-label run (98.00) is below the reported mean of 98.39. evaluate.py claims to reproduce the stored numbers but gives 97.78 / 97.52 / 98.30. These are small differences, but releasing the per-seed checkpoints would remove the ambiguity (check 01b).
The signature dimension is 2C+13 (moments 2C+1, morphology 8, trajectory 4); 'Full' is 2C+17.
15/19/31 = 2C+13 and 19/23/35 = 2C+17. The Epilepsy artifact has D = 15.
Computed the signatures with the released code for C ∈ {1, 3, 9} and checked the Epilepsy artifact.
The method description matches the code: Eq. 3 uses Mahalanobis distance with temperature τ; (L_min, L_max) = (8, 40) with K chosen on validation; λ_cal = 0.25; 50 density epochs; the signal → concept path has no neural component.
soft_assign defaults to 'euclidean' and is called with temperature = 1.0. Euclidean and Mahalanobis nearest prototypes agree on only 42.91% of patches; mean max-probability is 0.151 vs 0.369. get_patch_config returns a hard-coded {K:8, L_min:16, L_max:32} for every dataset. Checkpoint calib_weight is 0.01 (paper 0.25) and was saved at epoch 19 (paper 50). An undocumented learned ChannelMixer precedes the density model. The README training command omits --direct_sig, so following it trains the neural ConceptEncoder path.
Inspected the code and checkpoint configs. On all 18,400 Epilepsy test patches, computed nearest-prototype assignments under Euclidean (as released) and Mahalanobis (as in Eq. 3) distance.
The length-constrained DP (Eq. 4) returns the K-1 boundaries that maximise cumulative surprise subject to L_min ≤ length ≤ L_max, in O(TK).
Optimal and valid on 400/400 instances. Run time grows sub-linearly in T over the measured range (4.0 → 10.8 ms), consistent with O(TK).
Compared with brute force on 400 random small instances. Timed T = 500-4000 with K = 16.
Selective-prediction Table 9 (Epilepsy): AURC / E-AURC values are internally consistent, and fidelity is a useful abstention signal (fidelity E-AURC 0.01032 vs max-softmax 0.00117).
The rows are internally consistent. Implied accuracies are 97.64 (CT), 93.8 (TOTEM) and 90.4 (VQShape). TOTEM and VQShape match Table 1 full-label (94.56, 90.43); CT is 0.75 pp below its Table 1 value of 98.39. Fidelity E-AURC is 8.82× worse than CT max-softmax. It beats only TOTEM/VQShape scores.
Derived the optimal AURC (AURC − E-AURC) and the implied error rate for each row, and compared them with Table 1.
Fidelity detects synthetic OOD (Gaussian noise ×0.5 / 1.0 / 2.0, shuffles) with AUROC 0.864 → 0.992 while softmax stays near chance (Fig. 4, HAR).
The HAR numbers are unverified. On Epilepsy, fidelity AUROC is 0.997 / 0.999 / 1.000 (noise) and 1.000 (global shuffle). The density-model NLL alone gives 0.998 / 1.000 / 1.000 / 1.000, a baseline the paper omits. Max-softmax gives 0.681 / 0.715 / 0.827 / 0.523, so it is not uniformly at chance.
HAR was not run (checkpoint on Hugging Face). Ran the same protocol on the released Epilepsy model and added the frozen density model's own NLL as a baseline.
Deletion faithfulness (Fig. 5, Alg. 4): fidelity-guided deletion gives the lowest AUC on Epilepsy (0.804 vs random 0.836, reverse 0.871, GradientSHAP 0.806).
Released model: fidelity AUC 0.940, random 0.945, reverse 0.950, grad×input 0.900. Fidelity is essentially tied with random and worse than a simple gradient baseline. Accuracy with all patches deleted is 0.798, versus about 0.2 in the figure. GradientSHAP itself was not rerun.
Ran Alg. 4 (zero replacement, patch order) on the released Epilepsy full-label classifier with fidelity, reverse-fidelity, random and grad×input orderings.
Seed-level results (Table 4) support 'ConceptTime has higher mean accuracy on Epilepsy at all budgets and on UEA at 1% and 5%'.
The means are higher, as stated, but several differences are not significant: Epilepsy 5% +1.73 (p = 0.058); UEA 5% +0.32 (p = 0.84). Epilepsy 1% +2.50 (p = 0.0497) and UEA 1% +6.32 (p = 0.023) are marginal with n = 3.
Welch t-tests (n = 3) from mean ± SD against TSLANet.
The 1% / 5% label budgets are what the method actually receives.
On small UEA sets, '1%' means at least one label per class: Handwriting 26/150 = 17.3%, UWaveGestureLibrary 8/120 = 6.7%, JapaneseVowels 9/270 = 3.3%. On Handwriting and UWave, '1%' and '5%' are the same budget. The paper does not say whether the baselines received the same subsets.
Applied the released stratified_subset rule (max(1, round(n_c·f)) per class) to each UEA training set's class counts.
All stated differences match (1.72, 0.03, 0.56, argmax 10%, 0.26, 0.29, 13.6%/13.4%, 0.03, 0.528 → 0.666). The density-size differences (0.26 / 0.29) are within the seed SD (0.35-3.40).
Recomputed each stated difference from the tables.
Cited references exist and match their bib entries (load-bearing arXiv entries checked against the arXiv API; all 69 entries checked against Crossref).
All 8 arXiv IDs resolve to the cited works and authors. The EntroPE bib title differs from the arXiv record ('Entropy Guided Dynamic Patch Segmentation for Time Series Transformers'). Crossref best-match misses for conference papers are lookup failures, not missing papers. See references.issues.
Ran tools/check_refs.py on 69 entries. Resolved the 8 arXiv IDs via the arXiv API and compared titles and authors.
The released Epilepsy pipeline reproduces the Table 1 ConceptTime-Dynamic accuracies 97.91 / 98.01 / 98.39 (1% / 5% / full labels; 3-seed means, SD 0.96 / 0.71 / 0.35).
Released evaluate.py: 97.78 / 97.52 / 98.30 (macro-F1 96.57 / 96.22 / 97.37). With L_max: 97.87 / 97.52 / 98.35. All within 0.5 pp of the claimed means and within one seed SD. Tolerance: one reported SD.
Ran the released src/evaluate.py on the shipped Epilepsy test split (2300 samples) with the shipped density model and pipeline artifact. Also ran it once more with L_max from get_patch_config passed to the patcher, as train_pipeline.py does.
evaluate.py 'Reproduces the numbers stored in the checkpoint'.
Stored: 97.91 / 98.04 / 98.00. evaluate.py: 97.78 / 97.52 / 98.30, a gap of up to 0.52 pp. One cause is that evaluate.py builds SurprisePatcher without L_max, unlike training. Also, the stored single-run 1% value (2252/2300 = 97.91) equals the Table 1 '3-seed mean' exactly, and the stored full-label run (98.00) is below the reported mean of 98.39. Minor.
Compared the accuracies stored in the artifact with the output of the released evaluate.py from check 01.
The HAR and Sleep-EDF checkpoints reproduce Table 1: HAR 74.60 / 79.60 / 88.91, Sleep-EDF 70.21 / 71.92 / 78.15.
No evidence either way.
Not run. These checkpoints are hosted on Hugging Face, and the earlier verification step was OOM-killed at 8 GiB before reaching them.
The few-label headline numbers are consistent with the paper's own 3-seed matched protocol, which also fits the density model and vocabulary on all training inputs (CT-FullU).
HAR 1%: 74.60±1.76 (Table 1) vs 65.73±0.45 (Table 7), +8.87 pp, p = 0.0094. HAR 5%: 79.60±1.31 vs 68.86±0.31, +10.74 pp, p = 0.0034. Epilepsy: +1.27 / +1.05 pp, not significant. The single seed-2026 split (Table 8) gives 74.63 / 79.88, matching Table 1. Under the matched protocol on HAR, CT-FullU trails TS-TCC-SSL (72.51 at 1%, 80.55 at 5%), MiniRocket (86.34 / 94.62) and TSLANet (85.86 / 91.11). The paper does not reconcile Table 1 with Table 7.
Compared each Table 1/4 entry with its Table 7 CT-FullU counterpart using a Welch t-test from mean ± SD with n = 3. Also compared CT-FullU with the baselines under the matched protocol.
ConceptTime-Dynamic is the best interpretable method in all 12 benchmark × budget columns, with margins 'from 1.5 points (Epilepsy full-shot) to over 30'. At full supervision it 'trails by 2-8 points' the best black box.
Best interpretable in 12/12 columns: confirmed. Colour marks: 0 mismatches. But the smallest margin is 0.74 (HAR 1%, 74.60 vs TOTEM 73.86), not 1.5. The Epilepsy full margin is 1.48. The HAR full-label gap is 8.40 (97.31 MiniRocket vs 88.91), which is outside '2-8'. Minor text errors.
Parsed Table 1 from LaTeX and recomputed ranks, margins and gaps. Checked the colour/bold marks.
Ablation paragraph: Static loses 5.64 (HAR) and 2.92 (Epilepsy); 'replacing DP segmentation with EntroPE loses 4.5-8.5 points across benchmarks'; catch22 loses about 30 points (HAR) and 28 points (UEA).
Static 5.64 / 2.92: exact. catch22 30.04 / 28.53: exact. EntroPE full-label gaps are 4.50 (HAR), 8.45 (Epilepsy), 3.03 (Sleep) and 10.76 (UEA), so the range is 3.03-10.76, not 4.5-8.5. At 1% labels on Sleep, EntroPE beats ConceptTime (-0.74).
Recomputed the differences from the Table 1 values.
Table 3 statements (Mom. 87.7 vs Morph. 42.7; M=128 best; M=32 within 2.2 points; boundary signals within 1.8 points), and consistency of the default configuration across sweeps and with Table 1.
Text arithmetic is correct (45.0; M=128 best on all three datasets; gaps 1.1 / 0.5 / 2.2; boundary ranges 1.8 / 0.7 / 1.2). But the same default configuration gives different values: HAR 85.7 / 85.7 / 82.5, Sleep 74.8 / 74.0 / 74.5. None matches Table 1 (HAR 88.91, Sleep 78.15). The proposed Surp.f signature is not the best on HAR (Mom. 87.7 vs 85.7) or Sleep (Full 78.3 vs 74.8).
Recomputed the text statements. Compared the default configuration (Surp.f, M=32, surprise boundary), which appears in all three sweeps, across the sweeps and with Table 1 full-label accuracy.
FD transfer Table 2 summaries: Panel A means 67.61 / 91.09 / 94.37 / 90.76 and #1st counts 0 / 2 / 7 / 3; +3.28 pp; Panel B means 91.38 / 91.74 / 90.48; 7 of 12 directions improved; A→D +4.67, B→A -2.75.
Every summary statistic was reproduced to two decimals (e.g. 94.367 → 94.37, +3.28, 7/12, +4.67, -2.75).
Parsed both panels and recomputed means, win counts and per-direction differences.
Panel A 'Source-Mθ, 5%' and Panel B 'Source-Mθ, source vocab.' describe the same configuration and should agree.
They differ in 9 of 12 directions, e.g. A→C 75.84 vs 87.70, C→A 96.66 vs 89.74, B→D 98.53 vs 94.27. The Panel B 'Target-Mθ, target vocab.' row is identical for every source of a given target (A 88.34, B 90.86, C 87.66, D 95.06), so it is a no-transfer reference, not a transfer result.
Compared the two rows direction by direction.
The classifier g_ψ is lightweight with ~10^3-10^4 parameters for M ∈ {8, 16, 32}.
101,314-104,410 parameters (~10^5). The Epilepsy checkpoints have 102,850 for each label budget. Only the unused SparseLinearClassifier (130-6,682) falls in the claimed range.
Instantiated the released TransformerClassifier for M ∈ {8, 16, 32} and 2-26 classes. Counted the parameters in the Epilepsy checkpoint state dicts.
Density-model parameter counts in Table 6 (Epilepsy 110,149 / 810,629 / 1,204,357; UCI-HAR 108,597 / 807,413 / 1,201,141); Tiny has 'about 14%' of Default's parameters.
All six counts are exact (density model + C·C+2C mixer parameters). Tiny/Default = 13.6% (Epilepsy) and 13.4% (HAR).
Instantiated the released GaussianDensityModel and ChannelMixer for each configuration and counted parameters. Inspected the checkpoint.
The released patch configuration is feasible for the evaluated datasets, and the released training pipeline runs for them.
K·L_min = 128 and K·L_max = 256 are feasible only when 128 ≤ T ≤ 256. They are infeasible for HAR (T=127), Sleep-EDF (2999), FD (5119), FaceDetection, JapaneseVowels and UWave. There the DP returns no boundaries, and SurprisePatcher falls back to halving the last patch, giving score-independent lengths [63, 32, 16, 8, 4, 2, 1, 1] on HAR. train_pipeline raises ValueError('Infeasible patch configuration') for HAR and SLeep-EDF.
Ran dp_segment with the hard-coded config at each dataset length. Called the train_pipeline configuration path for HAR and SLeep-EDF.
On the released model, fidelity-based abstention is inferior to max-softmax in-distribution (direction of Table 9).
Fidelity E-AURC 0.00720 vs max-softmax 0.00113 (paper: 0.01032 vs 0.00117). The ordering is reproduced.
Computed AURC/E-AURC with the released Epilepsy full-label classifier on the test split, using F(x) with τ = median train nearest distance (2.031).
The Fig. 5 deletion curves are computed on the classifier whose accuracy is reported in Table 1.
At 0% deletion the accuracy is ≈0.948 (Epilepsy) and ≈0.571 (HAR), versus Table 1 full-label 98.39 and 88.91 (pixel-reading tolerance about ±0.01). The HAR x-axis has 4 points (0, 1/3, 2/3, 1), which implies K = 3 rather than K = 8.
Located the axis gridlines in the figure PNG and read the 0%-deletion point of the fidelity curve from the pixels.