Summary
The paper proposes MS-HVED, a super-resolution network for clinical brain MRI acquired as thick-slice 2D stacks. Each available axial, coronal and sagittal stack, first resampled to a common grid, gets its own variational encoder that outputs multi-scale Gaussian posteriors. These are fused by a Product-of-Gaussians (PoG) with an prior, and each stack's precision is down-weighted outside its field of view (FOV) by a smoothed mask (Eqs. 8–10). A shared decoder produces a 1 mm isotropic volume. Training uses physics-informed domain randomisation: oblique slice prescription, partial FOV, variable slice thickness and artefacts. The design is a direct transfer of U-HVED (multi-modal segmentation) to multi-orientation super-resolution.
Evaluation has four parts: synthetic benchmarks on an internal meningioma T1 set (MEN) and IXI-T1/T2 against ECLARE, TripleSR and SegResNet trained per input configuration (Tables 1–3); a geometry ablation (Table 4); downstream SynthSeg segmentation (Table 5); and 7 paired LR–HR healthy cases (Table 6). The headline evidence is a blinded study in which 7 neuroradiologists rated MS-HVED against SegResNet on 44 real cases (30 Nigerian, 7 meningioma, 7 paired healthy). MS-HVED is preferred for overall quality in 187/210 Nigerian assessments, and the full-input overall score is 5.93 vs 4.49 () (Tables 7–9).