A novel and well-engineered framing of biomechanical skeleton motion as a generative modality, but the fitting claims rest on a weak, asymmetrically evaluated baseline, the captioning metrics beat human references, several reported numbers (cascade runtimes, parameter count, dataset filtering) are internally inconsistent, and the closest prior architecture (LLaMo) is not acknowledged.
Soundness
2/4
Presentation
3/4
Contribution
3/4
Confidence
3/5
✓ 12 confirmed✕ 3 discrepancy◐ 2 inconclusive
Summary
The paper proposes OmniMM, a single autoregressive model that treats three modalities jointly: text, SMPL-H parametric motion (77-D per frame), and OpenSim-style BSM biomechanical joint coordinates (57-D per frame). It is a GPT-2-small Mixture-of-Transformers with one tower per modality and shared self-attention. Each motion stream is encoded by a CausalTAE into continuous 2.5 Hz latents and decoded with per-token flow-matching heads. One model covers seven tasks: T2M, T2B, M2T, B2T, M2B, B2M fitting, and synchronized T2BM generation (Sec. 5, Eq. 4).
To get training data, the authors place synthetic surface markers on SMPL meshes from six datasets and fit BSM with AddBiomechanics. The result is 26,253 paired clips (51 h, 152,935 text labels; Table 1). The paper reports state-of-the-art FID for T2M/T2B (Table 3), captioning that beats MotionGPT-style baselines (Table 4), and learned M2B/B2M fitting that is "comparable or better" than optimisation and 4–17x faster (Table 5, Table 9). It also reports that SMPL motion violates anatomical joint limits much more often than BSM motion, mostly through off-axis rotation (Tables 6–7).
Strengths
Biomechanical skeleton motion as a first-class generative modality
Sec. 5.2, Eq. 4–6, Eq. 8
Treating OpenSim/BSM joint coordinates as a third modality next to SMPL and text is a new and useful framing. One model covers generation, captioning, cross-representation fitting and synchronized generation (Eq. 4, Fig. 4). The factorisation for joint generation (B_k before M_k, Eq. 4 / Eq. 8) is clear. The flow-matching objective is correct: check 12 confirms symbolically that ε−z is the velocity of zt=(, and a toy recovers the target distribution.
Weaknesses
Fitting claim overstated; M2B is worse than the baseline on every metric
major · Table 5, Table 9, Sec. 6 l.431, Sec. 6.2 l.517–520
Sec. 6 (l.431) says OmniMM gives "comparable or better fitting accuracy". For M2B it is worse on all three metrics in Table 5: MPJPE 0.080 vs 0.078 m (+2.6%), PA-MPJPE 0.054 vs 0.051 (+5.9%), Accel 5.280 vs 4.200 (+25.7%). It is also worse on all three in Table 9 (OpenCap): +13.1%, +7.7%, +24.3% (checks 01, 02). Only B2M is better. None of these numbers has a confidence interval, and OpenCap has n = 10 sequences. Fix: reword the claim per direction, and report CIs or per-sequence distributions.
Weak and asymmetrically evaluated fitting baseline
major · App. B.3.1–B.3.2 (Eq. 12–21), Table 5, App. B.5
The optimisation baseline runs only 20 L-BFGS iterations per 64-frame window with no temporal prior. It is ~192x cheaper than the AddBiomechanics pipeline that defines the ground truth (24 min per 10 s; check 15). So the claimed speed-up of 4–17x is measured against a low-budget proxy, not against the method that produced the targets. The evaluation is also asymmetric (App. B.3.1–B.3.2). In M2B, the reference and OmniMM's output both pass through the same BSM→SKEL fit GB (~14 mm residual), but the baseline does not. In B2M, the baseline uses SKEL's joint regressor while GT uses SMPL FK. A toy (check 14, synthetic only) shows that a perfect baseline would still score ~13 mm MPJPE under this protocol, so Table 5 may favour OmniMM. The size of that bias cannot be measured without code. Fix: evaluate every method through the same mapping, add a converged/AddBiomechanics baseline, and report time vs accuracy curves.
Questions for the authors
How exactly are the Table 8 runtimes measured (clip length, hardware, batch size)? How can T2M-GPT → OmniMM(B2M) (1.06 s) be faster than B2M alone in Table 5 (1.700 s)?
If the optimisation baseline is evaluated through the same BSM→SKEL mapping GB as the reference and OmniMM, and run to convergence (or replaced by the AddBiomechanics pipeline that produced the GT), does OmniMM's M2B accuracy remain comparable?
Why do generated captions retrieve motions better than the human references in Table 4? What are the M2T/B2T metrics with the templated FineDance/TRUMANS/100STYLE subsets excluded?
How is the angular residual in Table 2b computed when no ground-reaction forces are available and inverse dynamics is omitted?
Which parameters are modality-specific in each tower: are QKV/output projections shared? The stated ~238 M matches shared attention projections, not the A.1.2 description.
Was the 20–200-frame filter applied before the Table 1 counts and the 8:1:1 split? How are AMASS text labels counted (are mirrored HumanML3D captions included)?
How does OmniMM's architecture differ from LLaMo (modality-specific MoT, causal VAE tokens, per-token flow heads), and which results depend on those differences?
Verification
Only the PDF was available: no code, data, checkpoints or videos. So no experiment could be rerun, and every check is table arithmetic, cross-table consistency, a symbolic/toy test of the method, or a literature lookup. Of 17 checks, 12 confirmed what they tested. Several of those confirmed that the numbers are internally consistent while showing the accompanying text overclaims: M2B is worse than the baseline on every metric in Tables 5 and 9, and generated captions beat human references. Three found discrepancies: cascade runtimes in Table 8 contradict Table 5 fitting times; the ~238 M parameter count does not match the described three-tower design; and the 100STYLE clip lengths and exact 80/10/10 splits contradict the stated 20–200-frame filter. Two were inconclusive: the Table 2b angular residual, and the size of the fitting-evaluation asymmetry, which a toy only illustrates. The flow-matching objective, representation dimensions, Table 1 totals, anatomical-gap tables and the BioAMASS reference values all held.
Liang et al. 2024b and Liang et al. 2024c, 'Mixture-of-transformers: A sparse and scalable architecture for multi-modal foundation models', arXiv:2411.04996
The same paper is listed twice (p.12, l.653-657) and cited under both keys (l.074, l.247, l.352). It exists and supports the MoT design claim; the duplicate entry should be merged.
Werling et al. (2023), 'AddBiomechanics: Automating model scaling, inverse kinematics, and inverse dynamics ...', PLoS ONE 18(11):e0295152
Table 2b says its AddBiomechanics reference values follow 'Table 2 of Werling et al. (2023)'. The values (2.17±2.44 cm, 0.046±0.027 BW, 0.11±0.02 BW·h, Hicks 0.05/0.1) match Table 2 of a different paper: Werling et al., 'AddBiomechanics Dataset: Capturing the Physics of Human Motion at Scale', ECCV 2024 (arXiv:2406.18537). That paper is not in the bibliography. The cited PLoS ONE paper reports no such table.
Kang et al. (2025), 'BioMoDiffuse: Physics-guided biomechanical diffusion for controllable and authentic human motion synthesis'
Malformed entry ('arXiv e-prints, pp. arXiv–2503') with no full identifier. The work exists (arXiv:2503.06151, Kang, Wang, Mu) and supports the related-work statement it is cited for.
Li et al. (2026), 'LLaMo: Scaling pretrained language models for unified motion understanding and generation with continuous autoregressive tokens', CVPR 2026
The work exists (arXiv:2602.12370) but is cited only for continuous tokens / CausalTAE and the 272-D representation (l.264, l.278). Its architecture is a modality-specific Mixture-of-Transformers on a pretrained LLM with a causal VAE and a per-token flow-matching head, which is essentially OmniMM's backbone design. That overlap is not acknowledged in Related Work or the contributions, so the citation understates the closest prior work.
Suggestions
Evaluate all fitting methods through the same evaluation mapping, and add a strong baseline (converged optimisation with temporal priors, or the AddBiomechanics pipeline itself) with an accuracy-vs-time curve.
Reword the fitting claim per direction (B2M better; M2B slightly worse, about 26% higher acceleration error), and report CIs or per-sequence distributions for Tables 5 and 9.
Report captioning results per dataset and with templated subsets excluded, and add a human or external-evaluator study for M2T/B2T.
Fix and document the runtime measurements in Tables 5 and 8 (clip length, hardware, batch size, and whether generation time is included).
Discuss LLaMo explicitly in Related Work and in the contributions, and isolate what is new (the biomechanical modality, data, fitting/synchronized tasks).
Correct the parameter count or the tower description in A.1.2, and report the flow-head size.
Report pre- and post-filter clip counts, and explain the label counting for AMASS and 100STYLE.
Remove or properly define the angular residual in Table 2b, and cite Werling et al. (ECCV 2024) for the reference values.
Report multiple training seeds for the main tables and ablations, and run the tokenizer ablation (Table 19) on more than M2B.
Release code, the paired dataset and evaluators, and complete the AI-use statement.
Ethics and integrity
No ethical or integrity concerns beyond the following. No text in the paper attempts to instruct the reviewer. The AI-use statement appears to be an unfilled template (all options listed), so it discloses nothing. Dataset licence terms for redistributing the derived biomechanical fits were not checked. The inconsistencies found (runtimes, parameter count, split counts) look like reporting errors, not signs of fabrication.
Scope of this review
Only the PDF was reviewed. No LaTeX source, code, trained models, derived dataset, evaluators or supplementary videos were available, so no experiment was rerun and no qualitative result could be inspected. The evaluation-asymmetry concern is supported by the protocol text and a synthetic toy only. Its effect on Table 5 is not quantified. Reference checks used Crossref/arXiv plus manual lookups of the Table 2 source papers.
Substantial paired dataset with quality comparison
Sec. 4, Table 1, Table 2a, App. B.5
Six datasets are refitted with AddBiomechanics (about 7,300 CPU-hours by check 15), giving 26,253 paired clips. All Table 1 totals and durations recompute exactly (check 08). Marker errors are 9–40% lower than BioAMASS on all three shared subsets, and the BioAMASS reference values are transcribed correctly from Keller et al. (check 10).
Baselines retrained under a common protocol
Table 3, App. B.1
All generation baselines (T2M, TM2T, T2M-GPT, MoMask, MotionGPT3) are retrained on the same 77-D/57-D features and splits, with motion length predicted from text rather than given as an oracle. The paper reports both FID wins and retrieval losses (OmniMM R@1 0.480 vs T2M-GPT 0.529 in T2M), and its "competitive" wording fits those numbers (check 05).
Careful anatomical-gap analysis
Sec. 6.1, Tables 6–7, Table 18, App. C
Sec. 6.1 separates HSMR joint-limit violations into off-axis rotation and hyperextension. Tables 6, 7 and 18 pass every monotonicity, logical-bound and median-vs-exceedance check we ran (check 09). This supports the claim that off-axis rotation, not hyperextension, explains most violations.
Out-of-pipeline validation and candid limitations
Table 9, App. B.4, Sec. 7
The OpenCap experiment (Table 9, App. B.4) tests the fitting on independently recorded data, and both methods degrade there (MPJPE x1.41–1.73, check 02). Sec. 7 openly states that the parametric stream of T2BM still violates anatomy and that the biomechanical data are SMPL-derived.
Detailed, internally consistent method appendix
App. A.1, B.2–B.3, Table 13
App. A–B give the tokenizer and backbone hyperparameters, the curriculum (Table 12, whose stage times sum to 57.0 h), the evaluator, and the fitting evaluation equations with a correspondence table (17 pairs = 14+2+1). All 14 dimensional identities we tested hold (check 13), and the GT rows of Tables 3 and 4 match exactly (check 17).
Captioning metrics exceed the human references
major · Table 4, Sec. 6 l.417–423, App. B.2, B.5, Table 17
In Table 4, generated captions retrieve their motions better than the human ground-truth captions: M2T R@1 0.682 vs 0.612, B2T 0.690 vs 0.605. MMDist is also better than GT (check 06). That points to evaluator or template effects rather than better-than-human captioning. 15.5% of evaluated clips (FineDance and TRUMANS) carry template-generated captions, and 22.3% if 100STYLE anchor captions are included. FineDance uses two fixed templates per dance, which inflates BLEU/CIDEr (96.46 vs 50.60) for a model that learns the templates. Fix: give per-dataset results, exclude templated subsets, and add an external evaluator or a human study.
Cascade runtimes inconsistent with fitting times
major · Table 8, Table 5, Sec. 6.2 l.485
Sec. 6.2 (l.485) defines cascade runtime as generation plus fitting. Yet T2M-GPT → OmniMM(B2M) totals 1.06 s in Table 8, less than B2M fitting alone in Table 5 (1.700 s), which implies −0.64 s of generation. Both OmniMM cascades total exactly 3.23 s although M2B and B2M fitting differ by 1.26 s (check 03, discrepancy). Runtime is part of the case for both learned fitting and synchronized T2BM (the slowest row at 4.40 s), so the timing evidence is unreliable as reported. Fix: state clip lengths, hardware and batch size for every timing, and recompute.
Closest prior architecture not acknowledged
major · Sec. 2, Sec. 5.3, contributions p.2, references
LLaMo (Li et al., CVPR 2026, arXiv:2602.12370) combines a modality-specific Mixture-of-Transformers on a pretrained LM, a causal VAE with continuous tokens, and per-token flow-matching heads, which is essentially OmniMM's backbone. The paper cites LLaMo only for CausalTAE and the representation (l.264, l.278). The novelty therefore lies in the biomechanical modality, the data and the fitting/synchronized tasks, not in the architecture, and the contribution list (p.2) should say so. Fix: discuss LLaMo in Related Work and make the architectural differences explicit.
Biomechanical ground truth is SMPL-derived; anatomical gap is partly structural
minor · Sec. 4, Sec. 6.1, Table 6, Sec. 7
BSM targets come from synthetic markers placed on SMPL meshes, not from optical markers or force plates. All generation and fitting metrics therefore measure agreement with a deterministic SMPL→BSM pipeline rather than with real biomechanics. The anatomical-gap result (Table 6) partly follows from the representation: BSM elbows and knees have no off-axis DoF, so off-axis violations are near zero by construction (check 09). GT biomechanical motion still violates HSMR limits in up to 2.09% of frames, which is not explained. Fix: frame Sec. 6.1 as a representation comparison, and add real-marker validation beyond the 10 OpenCap sequences.
No uncertainty over training runs
minor · Tables 3–5, 8, 19, 20
FID, MMDist, every NLG metric, every fitting metric and every ablation (Tables 8, 19, 20) are single numbers from a single training run. The ± values in Table 3 reflect only evaluation resampling. Several conclusions depend on small gaps, such as the T2BM vs standalone T2B drop (R@1 0.495 vs 0.511, z = −4.0 from evaluation noise alone; check 05) and T2M-GPT→M2B beating T2BM on pair MPJPE (82.8 vs 89.9 mm; check 04). Fix: report multiple seeds or bootstrap CIs.
Parameter count inconsistent with the described architecture
minor · App. A.1.2 (p.17, l.886–892)
App. A.1.2 describes three GPT-2-small towers, each with modality-specific LN, QKV/output projections and MLPs, totalling "approximately 238 M" parameters. Exact arithmetic gives 293.8 M before flow heads (255.2 M without the token embedding). 238 M matches (237.1 M) a variant with shared attention projections instead (check 07, discrepancy). Either the description or the count is wrong, which matters for reproducing the model and for comparing model sizes against the baselines.
Dataset filtering and label counts do not add up
minor · Table 1, App. B.5–B.6, Table 17
The 100STYLE mean clip length is 517,519/2,062 = 251 frames, above the 20–200-frame retention cap (App. B.6). Yet its split is exactly 1,650/206/206 = 80/10/10 of Table 1, and CombatMotion train is exactly 0.8 x 7,740 (check 08, discrepancy). So either the filter was not applied or Table 1 counts are taken before filtering. AMASS has 8.28 labels per clip versus ~3.08 per motion in HumanML3D, close to the mirrored total (ratio 0.972). Fix: give pre- and post-filter counts and explain how labels are counted.
Unexplained angular residual and wrong source citation in Table 2b
minor · Table 2b, footnote 3 (p.4), Sec. 3 l.197–198
Table 2b reports an angular residual of 0.08 ± 0.12 BW·h and places it next to the Hicks 0.1 threshold. Residuals require measured external forces, but footnote 3 says there are no force plates and Sec. 3 (l.198) omits inverse dynamics (check 11, inconclusive). The AddBiomechanics reference column is attributed to Werling et al. (2023, PLoS ONE), but its values come from Table 2 of the AddBiomechanics Dataset paper (Werling et al., ECCV 2024), which is not in the bibliography (check 10).
The MoT paper is listed twice (Liang 2024b/2024c). The Kang et al. 2025 entry is malformed ("pp. arXiv–2503"). There is a broken reference to "Fig. 5.3" (A.1.2), and λKL in Table 10 is split across lines. A.1.2 uses σ where Eq. 5 uses t. The root velocity frame is the pelvis frame in Sec. 5.1 but the heading frame in A.1.1. The AI-use statement appears to be the unedited template, listing every option (including a typo "LMM-generated"), so it says nothing. No code or data release is stated.
Table 2 reference values follow Table 1 of Keller et al. (2023) (BioAMASS) and Table 2 of Werling et al. (2023) (AddBiomechanics); our marker errors are lower than BioAMASS
(a) BioAMASS values match Keller Table 1 exactly (DFAUST 1.54/2.00, CMU 1.70/2.37, MPI Limits 1.70/2.37 cm). Ours is lower by 17-37% (bony) and 9-40% (soft). (b) The AddBiomechanics column (2.17±2.44 cm, 0.046±0.027 BW, 0.11±0.02 BW·h; Hicks 0.05/0.1) matches Table 2 of the AddBiomechanics Dataset paper (Werling et al., ECCV 2024, arXiv 2406.18537). The cited Werling et al. (2023) PLoS ONE tool paper has no such table, so the citation points to the wrong Werling paper. Ours 1.97 vs 2.17 cm compares synthetic SMPL markers with real optical markers, so the two are not like-for-like (the footnote acknowledges this).
Transcribed source tables fetched on 2026-11-28 (Keller et al. TOG 2023 via arXiv 2509.06607 Table 1; Werling et al. ECCV 2024 via arXiv 2406.18537 Table 2; PLoS ONE 2023 article page) and compared in script; relative improvements computed
Angular residual 0.08 ± 0.12 BW·h is reported for the derived data and is below the Hicks 0.1 threshold
The residual definition requires measured ground-reaction forces. The paper states it has no force-plate data (footnote 3) and omits the inverse-dynamics stage (Sec. 3, l.198). Yet it reports an angular residual (0.08 ± 0.12 BW·h, sd/mean 1.5 vs 0.18 for the reference) without saying how it was computed. The number cannot be interpreted or reproduced from the paper, and putting it next to the Hicks threshold may mislead readers.
Compared with the residual definition in the source paper (Werling et al. 2024, Table 2 caption): residuals are RMS discrepancies against measured external forces
Flow-matching objective: with z_t=(1-t)z+tε the regression target ε−z is the velocity, and integrating from t=1 to 0 (25 Euler steps) samples the data distribution
dz_t/dt = ε − z symbolically, so Eq. 6 regresses the correct velocity. With the exact field, 2000 Euler steps recover mean 1.5008 / std 0.3995 (target 1.5 / 0.4). 25 steps give 1.5001 / 0.3751, a 6% std shrinkage from discretisation in this toy. The formulation is correct. A.1.2 writes σ (from 1 to 0) where Eq. 5 uses t, a minor notation inconsistency.
sympy derivative; 1-D Gaussian toy with exact conditional velocity integrated backwards with 25 and 2000 Euler steps (400k samples, seed 0)
Representation dimensions, token rates, coordinate counts, correspondence counts and curriculum time are internally consistent
All 14 arithmetic identities hold: 10 = 6+1+3; 77 = 10+63+4; 57 = 10+43+4; 8x compression gives 2.5 Hz; 49 = 3+3+43; SKEL 46 = 3+43; 24 = 2+4+18; 14+2+1 = 17 pairs; 7 unsupervised SKEL joints; Table 12 stage times sum to 57.0 h. Minor wording inconsistency: root linear velocity is in the pelvis frame in Sec. 5.1 but in the heading frame in A.1.1.
Arithmetic
The M2B/B2M comparison in Table 5 uses a common evaluation space that treats OmniMM and the optimization baselines equally
By the text, the M2B reference and OmniMM output both go through the same BSM->SKEL fit G_B (residual ~14 mm, up to 300 L-BFGS iterations), while the baseline is SKEL fitted directly to SMPL joints with 20 L-BFGS iterations per 64-frame window and is never mapped through G_B. For B2M the baseline uses SKEL’s SMPL regressor, whereas GT and OmniMM use SMPL FK. In the toy, a baseline that recovers the anatomical joints exactly still scores 12.9 mm MPJPE against the G_B reference, while a predictor sharing G_B scores 0 at zero pose error. The baseline also never sees the AddBiomechanics marker pipeline that defines the GT. The bias in Table 5 cannot be quantified without code or data.
Documented the protocol from the text; toy simulation (synthetic, not the paper data) of a systematic ~14 mm evaluation-mapping residual applied to the reference and to one predictor only
Fitting a 10-s sequence with the data pipeline takes ~24 min; OmniMM reduces fitting time relative to optimization (Table 5)
The arithmetic is consistent: 51.00 h of motion at 24 min per 10 s is about 7,344 CPU-process-hours. The AddBiomechanics pipeline that produced the GT (24 min per 10 s) is ~192x slower than the Table 5 optimization baseline (7.501 s) and ~3,273x slower than OmniMM M2B (0.440 s). So the substantial time reduction in Table 5 is measured against a deliberately low-budget baseline (20 L-BFGS iterations per window, no temporal prior), not against the fitting method that defines the targets. Neither the clip length behind the Table 5 timings nor the hardware for OmniMM vs the baseline is stated.
Arithmetic of pipeline cost and time ratios
Bibliography entries exist and are correctly cited
53/60 resolved by arXiv ID or DOI. Fieraru 2021, Guo 2022a and Xu 2020 resolve by Crossref bibliographic match. Kang 2025 (arXiv:2503.06151) and LLaMo (arXiv:2602.12370) exist. AnimationGPT (GitHub) and GPT-2 (OpenAI report) cannot be checked through these services. No non-existent references were found. Issues: the MoT paper is listed twice (Liang 2024b/2024c); the Kang 2025 entry is malformed; Table 2b cites Werling et al. 2023 (PLoS ONE) for values that come from the 2024 AddBiomechanics Dataset paper; LLaMo, the closest architectural prior work, is cited only for tokenization. See work/ref_issues.json.
tools/check_refs.py (Crossref/arXiv) over 60 entries, summarised by script; manual web lookup for unresolved entries and for the load-bearing Table 2 sources
Human-caption GT retrieval rows are consistent between Table 3 and Table 4; R@k is monotone
Table 4 GT rows match Table 3 GT rows exactly: M2T/T2M 0.612 / 0.873 / 0.943; B2T/T2B 0.605 / 0.863 / 1.151. R@1 <= R@2 <= R@3 holds for all eight Table 4 rows. This supports the paper’s statement that the same evaluators and evaluation clips are used in both tables.
Cross-table equality and monotonicity
OmniMM achieves comparable or better fitting accuracy than optimization-based fitting while substantially reducing inference time
Speed-ups confirmed: M2B 7.501/0.440 = 17.0x, B2M 6.966/1.700 = 4.1x. B2M: OmniMM better on all metrics (MPJPE -2.5%, PA-MPJPE -31.9%, Accel -49.0%). M2B: OmniMM worse on all three metrics: MPJPE 0.080 vs 0.078 (+2.6%), PA-MPJPE 0.054 vs 0.051 (+5.9%), Accel 5.280 vs 4.200 (+25.7%). The claim holds as worded only if a 26% worse acceleration error counts as comparable; better holds only for B2M. No uncertainty is reported, so the M2B differences cannot be tested for significance.
Table arithmetic: relative difference per metric and speed-up factors
On OpenCap OmniMM achieves accuracy comparable to optimization-based fitting; MPJPE increases for both methods relative to Table 5
Both methods degrade relative to Table 5 (MPJPE x1.41-1.73), so the statement that the difficulty is not specific to the learned model is consistent with the numbers. M2B: OmniMM worse on all three metrics (MPJPE 0.138 vs 0.122, +13.1%; PA-MPJPE 0.084 vs 0.078, +7.7%; Accel 9.060 vs 7.286, +24.3%). OmniMM M2B MPJPE degrades more than the baseline (x1.73 vs x1.56). B2M: OmniMM better on all three. comparable holds for B2M; for M2B it is a generous reading. Evidence rests on n=10 sequences from 9 subjects with no CIs, and Table 9 reports no timing.
Relative differences and Table 9 / Table 5 degradation ratios
Cascade runtimes in Table 8 are the sum of generation and fitting time (l.485) and are consistent with Table 5 fitting times
T2M-GPT -> OmniMM(B2M) total 1.06 s is smaller than the B2M fitting time alone in Table 5 (1.700 s), which implies a generation time of -0.64 s. The analogous M2B cascade implies +0.68 s for T2M-GPT generation. Both OmniMM cascades total exactly 3.23 s although M2B (0.440 s) and B2M (1.700 s) fitting times differ by 1.26 s. A possible explanation is that generated clips are shorter than GT clips, but that would need a B2M time 38% below Table 5. The paper does not explain this, so the runtime columns of Tables 5 and 8 are not consistent as reported.
Implied generation time = cascade total minus Table 5 fitting time
Synchronized T2BM achieves the best generation quality in both representations and better pair consistency than the OmniMM cascades; T2BM and ablation rows are consistent across tables
T2BM is best on all six generation columns of Table 8, and its pair MPJPE/PA-MPJPE (89.9/55.3 mm) beat both OmniMM cascades (142.3/82.9 and 122.5/83.9). The T2BM row matches Table 3 exactly and Table 5 within rounding (0.090 m vs 89.9 mm, 0.055 m vs 55.3 mm, 4.40 s). Table 19 CausalTAE = Table 5 M2B OmniMM; Table 20 flow matching = Table 3 OmniMM T2B. Caveats: T2M-GPT->M2B has a lower pair MPJPE (82.8 vs 89.9 mm, 8.6% better), which the text calls comparable alignment. T2BM is also the slowest row (4.40 s). OmniMM standalone T2B (Table 3, R@1 0.511) beats T2BM (0.495) but is not in Table 8.
Column ranking of Table 8; cross-table equality within rounding
OmniMM achieves competitive text-to-motion quality in both spaces; T2BM performs comparably to its standalone counterparts
OmniMM has the best FID in both spaces (0.117 T2M, 0.063 T2B). On retrieval it is not best. T2M: R@1 0.480 ranks 3/6, behind T2M-GPT 0.529 (z=-11.3) and MoMask 0.511 (z=-7.8); R@3 0.744 ranks 3/6; Diversity ranks 4/6 by distance to GT. T2B: R@1 0.511 ties MoMask, behind T2M-GPT 0.528 (z=-3.6); best MMDist and MModality. competitive is fair wording but does not mean best. T2BM vs standalone: T2M is indistinguishable (R@1 -0.001, z=-0.2). T2B shows a small but significant drop (R@1 0.495 vs 0.511, z=-4.0; R@3 0.747 vs 0.764, z=-4.7). The ± reflects only evaluation resampling, not training seeds, and FID/MMDist have no uncertainty.
Per-column ranking (Diversity by distance to GT); z-tests on R@1/R@3 treating the undefined ± as a 95% CI half-width over 20 replications
OmniMM achieves strong M2T/B2T performance; its generated captions reach R@1 0.682 (M2T) and 0.690 (B2T)
The numbers are internally consistent and OmniMM beats both baselines on all metrics (CIDEr 96.46 vs 50.60, 1.91x). But generated captions retrieve better than the human reference captions: M2T R@1 0.682 vs 0.612 (+0.070), B2T 0.690 vs 0.605 (+0.085), and MMDist is also better than GT. That is a validity flag for the author-trained evaluator rather than evidence of super-human captioning. 15.5% of evaluated clips (FineDance 275 + TRUMANS 188 of 2,995) carry template-generated captions, or 22.3% including 100STYLE anchor captions. FineDance has 2.00 labels per clip, two fixed templates per dance. These inflate n-gram metrics for a model that learns the templates. No per-dataset breakdown or NLG uncertainty is given.
Differences vs human-caption GT rows; template-caption share of the evaluation set from Table 17; labels per clip from Table 1
OmniMM (GPT-2-small backbone, three towers with modality-specific LN, QKV/output projections and MLPs) has approximately 238 M parameters; each CausalTAE has ~27 M
Three full GPT-2-small layer stacks (3 x 85.05 M) plus the text embedding (38.6 M) and input projections give 293.8 M before flow heads, 23.5% above the claimed ~238 M. Even without the token embedding it is 255.2 M. The claimed 238 M matches almost exactly (237.1 M) a variant where QKV/output projections are shared and only LN and MLPs are modality-specific, which contradicts the A.1.2 description. With two flow heads (~20 M each under an assumed MAR-style layout) the described model would be ~334 M. CausalTAE estimate 26.2-26.3 M is consistent with ~27 M.
Exact GPT-2-small parameter arithmetic (reproduces 124.44 M), variants of which parts are modality-specific; flow-head and CausalTAE estimates under stated layout assumptions
Dataset statistics (Table 1 totals, durations; FineDance 3,341 x 200 frames, 6,682 labels; Table 17 splits 21,091/2,995; 8:1:1 split; clips retained only if 20-200 frames; 100STYLE 2-4 annotations per clip)
Confirmed: all Table 1 column sums (26,253 / 3,672,138 / 51.00 h / 152,935); every duration = frames/20/3600; FineDance 3,341 x 200 = 668,200 and 2 x 3,341 = 6,682; Table 17 sums 21,091 / 2,995; 100STYLE 3.78 labels/clip is consistent with 2-4. Inconsistent: 100STYLE mean clip length is 517,519/2,062 = 251.0 frames, above the 200-frame retention cap of B.6. Yet its split is exactly 1,650/206/206 = 80/10/10 of Table 1 with nothing removed, and CombatMotion train is exactly 0.8 x 7,740 = 6,192. So the 20-200-frame filter either was not applied as described or Table 1 counts precede filtering, and the text does not say which. AMASS has 8.28 labels/clip, while HumanML3D has ~3.08 descriptions per motion (44,970/14,616). 87,384 is close to the mirrored HumanML3D total (89,940; ratio 0.972), which suggests mirrored captions are counted against non-mirrored clips (unverified).
Recomputed sums, durations at 20 fps, mean clip length, labels per clip, split fractions
Anatomical-gap tables are internally consistent with the App. C definitions; the HSMR gap mainly reflects off-axis rotation rather than hyperextension
No monotonicity violations. Every elbow satisfies viol(tau) >= off-axis(tau), with small gaps (e.g. GT L elbow 41.2 vs 40.93 at 10 deg, gap 0.27, close to hyperextension>10 = 0.27). All knee bounds hold, and all Table 18 medians agree with the exceedance rates of Table 7. The tables are consistent with the claim that off-axis rotation, not hyperextension, explains most violations. Unexplained: GT biomechanical motion still violates HSMR limits in up to 2.09% of frames (R elbow, >10 deg) while its hyperextension is 0/0/0. The off-axis gap is largely structural, since BSM has no off-axis DoF to violate.
Monotonicity in threshold; logical bounds between HSMR violations and off-axis/hyperextension rates (elbows: viol >= off-axis; knees: viol <= off-axis + hyperextension + over-flexion, viol(10) >= off-axis(20)); median-vs-exceedance and Markov bounds against Table 18