An original reconstitution with a robust core result (length-proportional partitioning, Fig. 4G), but there is no Methods section. Several quantitative claims are contradicted by the paper's own figures: the single central minus-domain, the domain size tracking the motor ratio, hysteresis "at any ratio", Fig. 5 statistics, and the Fig. 2 centroid metric. The link to cells is correlative only.
Soundness
2/4
Presentation
2/4
Contribution
3/4
Confidence
4/5
✓ 5 confirmed✕ 12 discrepancy○ 1 not checkable
Summary
The authors bind a plus-end kinesin (KIF5B) and a minus-end kinesin (NCD) to a supported lipid bilayer. They restrict the bilayer to micropatterned discs, ellipses and bars and add stabilized microtubules (MTs). Polarity sorting produces bands of aligned MTs that split the confinement into steady domains, each enriched in one motor. Domain number and arrangement depend on confinement area and shape, on the NCD:KIF5B ratio, and on MT number and length. The resulting organizations are radial, polar, bipolar or multipolar (Fig. 1–4). Small discs respond asymmetrically to the two motors, which the authors attribute to unequal motor strength and support with cytosim simulations (Fig. S1). They also report that sequential motor addition reaches states that mixing cannot (history dependence).
In near-linear confinements the domain size saturates at about 15 µm, and the number of MT bands then grows linearly with length (Fig. 4F,G, S3). In Taxol-stabilized PtK2 cells on 12 µm lines, MTs form regularly spaced bands with the Golgi on alternate domains, and the band number scales with cell length (Fig. 5). The authors read this as the same motor-based partitioning mechanism acting in cells.
Strengths
Original, well-controlled reconstitution geometry
Fig. 1A–C, Fig. 4A,C; p.4
Two opposing motors diffuse in a micropatterned supported lipid bilayer, so the confinement boundary is set by the motors, not by walls. This separates the effect of boundaries from bulk active-nematic dynamics. The images in Fig. 1B, 4A and 4C show clean, reproducible partitions.
Systematic scan of area × motor ratio
Fig. 1C,D
Fig. 1D covers 4 areas (250–8000 µm²) × 6 NCD:KIF5B ratios (1–20) with roughly 20–29 confinements per condition. The motor ratio sets which motor forms central vs peripheral domains, and this inversion is visible directly in the integer-count scatter (check 15 digitized the ratio-1/2 columns).
Wavelength selection in bars is quantitatively consistent
Fig. 4F,G; Fig. S3
Fig. 4G is internally consistent. The mean domain length for L≥43 µm is 14.9 µm vs the stated 15 µm. Band numbers 1.10–6.76 grow with N/L≈0.056– µm⁻¹ (intercept ≈0, spacing 16.6 µm) and match within +0.03 to +0.53 bands (check 06). Fig. S3 is linear with R² ≥ 0.96 for 4 of the 5 ratios (check 05). This is the paper's strongest quantitative result.
Weaknesses
No Materials and Methods; results are not reproducible as posted
major · Whole manuscript; Fig. S1 caption (p.25)
The preprint has no Methods, yet Fig. S1 refers to "Materials and Methods" twice. Protein constructs and purification, motor surface densities, lipid composition, MT preparation and lengths, imaging, the segmentation and domain definition, the centroid computation, the cytosim modifications and parameters, statistical procedures and how n was counted are all missing. Movies S1–S23 are cited but not provided. Several of the discrepancies below (domain counting in Fig. 4D, centroid pooling in Fig. 2) cannot be resolved without these details. Fix: add a full Methods section, release the analysis and simulation code, and deposit raw image data.
"Single central minus-domain" and opposite-trend claims contradicted by Fig. 4D
major · p.6; Fig. 4C–E
p.6 states that adding NCD reduces minus-domains "eventually down to a single central minus-domain (Fig. 4C, bottom row)". In Fig. 4D at 20:1, NCD counts span 4–11 (mean ≈6.3, n = 20), and no ellipse has one domain. The mean NCD length is ≈63 µm in a ≈385 µm ellipse (check 01). From 6:1 to 20:1 the NCD count halves (12.5 → 6.3) while the KIF5B count stays at ≈14 (|ΔN| up to 7.6). This is impossible for alternating 1D partitions (check 02) and contradicts the "opposite trend" wording. Either the representative image is atypical, or the counted KIF5B "domains" at high ratio are not partitions. Fix: correct the text and define how domains are segmented and counted.
Domain sizes do not "accurately reflect" the motor ratio at low ratios
major · p.6; Fig. 4E
From the digitized Fig. 4E means, L = 0.06, 1.02, 1.17, 4.24, 10.3, 19.9 for ratios 1, 2, 3, 6, 10, 20 (check 03). Size tracks the ratio from 6:1 upward but misses by factors of 15.5, 2.0 and 2.6 at 1:1–3:1. At 2:1 and 3:1 NCD and KIF5B domains are nearly equal (15.0 vs 14.7 µm; 20.9 vs 17.9 µm). This also sits uneasily with the p.4 argument that the weaker NCD needs larger domains. Fix: restrict the claim to the range where it holds, or present a model that predicts the full curve.
Questions for the authors
How are domains segmented and counted in Fig. 4D? At 10:1 and 20:1 the KIF5B count (≈13–14) far exceeds the NCD count (≈6–8). Are many KIF5B "domains" small spots within or along NCD domains rather than alternating partitions?
Are the Fig. 2 violin values one pooled centroid per confinement or one per domain? What are the per-domain radial distances and domain counts for the radial vs polar states in Fig. 2C?
What confinement area was used in Fig. 2D–G (the discs measure ≈36–40 µm across)? Were mixing-from-the-outset controls done at that area with the final motor concentrations, and which configurations did they give?
Which MT concentrations correspond to the four columns of Fig. 3B, and what were the measured MT length distributions before and after tubulin addition?
How were the 13 ± 5 and 77 ± 33 µm² values computed (per domain or per cell, n), and are the Fig. 5G and 5H cell populations the same?
Does inhibiting dynein (e.g. ciliobrevin/dynarrestin, or p150 overexpression) or depleting kinesin-1 abolish the Taxol-induced banding, and does EB3 or hook decoration confirm alternating MT polarity between bands?
Which cytosim parameters (motor stall force, speed, density, unbinding, MT number and length) were used, and do the simulations reproduce the large-area inversion and the bar wavelength (~15–17 µm)?
Verification
Only the PDF was available, with no Methods, data, movies or code, so all quantitative checks used plots digitized from the 220-ppi figure rasters, OCR of axis labels, and text extraction. We ran 18 scripted checks. Five confirmed the paper: the Fig. 4G wavelength selection (≈15 µm domains, linear band number), the Fig. 4B frequencies against the stated n (GRIM-style), the Fig. 4C geometry and length budget, the Fig. 5H linear scaling, and the Fig. 2A disc size. Twelve found discrepancies. Four concern main-text claims: the single central minus-domain and the opposite trend (Fig. 4D), domain size reflecting the motor ratio (Fig. 4E), and hysteresis "at any ratio" (Fig. 1D, 4B). The Fig. 2 centroid metric is inconsistent with its caption. Others concern Fig. 5 statistics and ranges, Fig. S3 robustness and n, Fig. 3 labels, a mis-citation, and 11 text–caption inconsistencies. The simulation claim could not be checked. Digitization tolerances are stated per check. Every discrepancy is well outside them, but values read from plots remain approximate.
5Confirmed
12Discrepancy
1Not checkable
✕Discrepancyp.6 (Results, Partition depends on confinement shape); Fig. 4C bottom row, Fig. 4D, Fig. 4E
[43] R. Grover et al., Transport efficiency of membrane-anchored kinesin-1 motors depends on motor density and diffusivity. PNAS 113, E7185 (2016)
Exists. Cited on p.6 for the claim that 'the biochemistry sets the size of the domains as expected from theory (43, 44)'. It is an experimental gliding-assay study of single-motor-type transport efficiency and contains no theory of motor-domain size (abstract checked, work/verify/16_ref_43_44.py). The relevant theory is the authors' own refs 51/52.
[44] D. Inoue et al., Depletion force induced collective motion of microtubules driven by kinesin. Nanoscale 7, 18054 (2015)
Exists. Cited together with [43] for a domain-size theory, but it is an experimental study of depletion-force-induced collective MT motion and says nothing about domain size in two-motor systems.
[1] G. J. Brouhard, L. M. Rice, Nat. Rev. Mol. Cell Biol. (2018)
Exists (doi 10.1038/s41580-018-0009-y), but the volume is missing and the pages are given as the placeholder '1–13' (actual 19, 451–463).
[37] T. Sanchez et al., Spontaneous motion in hierarchically assembled active matter. Nature (2012)
Exists, but the volume is missing and the pages are given as the placeholder '1–5' (actual 491, 431–434). Similar '1–N' placeholder pages appear in [16], [36], [40], [74], [75], [79], [90].
[3] A. Yildiz, Mechanism and regulation of kinesin motors. Nat. Rev. Mol. Cell Biol. (2024)
Exists. Volume and pages are missing, and the DOI is broken by a space ('s41580-024- 00780-6').
[17] Ojakian & Schwimmer (1994); [36] Foster et al. (2015); [68] Corthésy-Theulaz et al. (1992)
All exist. In each entry the author list is duplicated (e.g. 'G. K. Ojakian, R. Schwimmer, K. G. Ojakian, R. Schwimmer'), a reference-manager export error.
[63] F. Verde et al., Taxol-induced Microtubule Asters in Mitotic Extracts of Xenopus Eggs : J. Cell Biol. 112 (1991)
Exists, but the title is truncated after the colon (full: '...: requirement for phosphorylated factors and cytoplasmic dynein').
[86] H. Liu, J. P. I. Welburn, A circle of life: platelet and megakaryocyte cytoskeleton dynamics in health and disease (2024)
No journal, volume or pages. The work is Open Biology 2024 (doi 10.1098/rsob.240041); Crossref's top hit was an author-response record of that paper.
[33] Needleman & Dogic (2017); [50] D'Souza et al. (2023); [60] Chandrakar et al. (2020)
Suggestions
Add a complete Materials and Methods section (proteins, lipids, MT preparation, motor densities, imaging, segmentation, centroid and domain definitions, simulation parameters, statistics) and deposit raw images, analysis code and the modified cytosim.
Correct the p.6 text on Fig. 4C–E: drop "single central minus-domain" or show its frequency, and restrict "sizes accurately reflect the motor ratio" to 6:1–20:1 or explain the low-ratio behaviour.
Replace the pooled centroid in Fig. 2 with per-domain radial distances plus a symmetry/polar order parameter and the domain count per confinement.
State the confinement area for Fig. 2D–G and add mixing controls at that area and the final motor concentrations before claiming hysteresis.
Fix the Fig. 3A/B concentration labels and report the MT length distributions that underlie the "MT length" claims.
Report n, the dispersion and the statistical tests for every quantitative claim, in particular the Fig. 5H regressions, the length-independence in Fig. 5G, and the Fig. S3 linearity.
Test the in-cell mechanism directly: perturb dynein and kinesin and measure MT polarity in the bands (EB comets or hook decoration).
Harmonize drug concentrations and timings between the text and the Fig. 5/S4 captions, and fix the panel letters, the axis descriptions (Fig. S1C, Fig. 5G) and the reference list (refs 43/44 → 51/52, placeholder pages, duplicated authors).
Scope of this review
Only the posted PDF was examined. It has no Methods section, the supplementary movies S1–S23 are not included, and no code, raw images or numerical data are released. All figure-based numbers were digitized from rasters and are approximate, with stated tolerances. The cytosim simulations could not be rerun. Domain segmentation could not be re-done, so the definitions behind Fig. 2 and Fig. 4D are inferred from plotted values. The in-cell experiments could not be assessed beyond the plots in Fig. 5/S4.
All 42 stacked-bar segments in Fig. 4B match a k/n fraction for the stated sample sizes within 0.6 pp (GRIM-style, check 14). The ellipse geometry of Fig. 4C (measured length 381–388 µm, ≈AR 60 at 2000 µm²) agrees with the summed domain lengths within tolerance (check 04).
Dynamic perturbations probe how steady states depend on history
Fig. 2D–G, Fig. 3E–H, Fig. S2
Adding a motor (Fig. 2D–G) or free tubulin (Fig. 3E–H, S2) to a pre-formed steady state reverses polarity or converts multipolar to bipolar/polar states. These experiments probe the dynamics of the steady state, not just endpoint morphology, which is conceptually valuable for active-matter studies.
A bridge to cells with a polarity proxy
Fig. 5F–H; p.7
PtK2 cells on 12 µm lines show regularly spaced MT bands, with Golgi mini-stacks on alternate domains. Band number rises linearly with cell length (digitized: slope 0.040 bands/µm, R² = 0.80, check 09), and domain area is independent of cell length (Spearman ρ = 0.03 and 0.11, check 07). This qualitatively parallels the in-vitro bars.
NCD
/
LKIF5B
History-dependence (hysteresis) claim contradicted by Fig. 1 and Fig. 4B
major · p.5, p.8; Fig. 2D–G, Fig. 1C,D, Fig. 4B
p.5 and the Discussion (p.8) say sequential addition gave configurations "not observed when they were mixed from the outset at any ratio, including … multiple peripheral minus domains". Yet with motors mixed at the outset, every 8000 and 2000 µm² disc at ratio 1 had ≥ 2 NCD domains (means ≈7.8 and ≈4.4), and p.4 itself describes "multiple small peripheral minus-domains". In Fig. 4B, 26/26 circular 2000 µm² confinements at 10/10 nM were multipolar (check 15). The claim could at most apply to the unstated disc size used in Fig. 2D–G. Those discs measure 36–40 µm across (≈1000–1300 µm², check 12), which is not one of the Fig. 1 sizes, so a matched mixing control is missing. Fix: state the area, run mixing controls at that area and the final motor concentrations, and rephrase.
Centroid metric in Fig. 2 cannot distinguish radial from central organizations
major · Fig. 2B,C,E,G and caption (p.17); p.4
The caption says the violins show "individual motor domain centroid positions". However, the medians (Fig. 2C KIF5B ≈2.7 µm in a 12.6 µm radius disc; Fig. 2G ≈4–5 µm in ≈18 µm discs) match pooled per-confinement centroids of 2–6 symmetric rim spots, not per-domain centroids (≈11–17 µm) (Monte Carlo, check 13). The Fig. 2C sample sizes (40 NCD vs 27 KIF5B despite several KIF5B spots per disc) point the same way. A pooled centroid near the centre cannot separate one central domain from several symmetric peripheral ones. So the Centre/Periphery annotations and the polar vs radial quantification behind the asymmetry claim (abstract, p.4) are not supported by this metric. Fix: report per-domain radial distances, or a symmetry measure such as a polar order parameter, plus the domain count.
In-cell mechanism is inferred from morphology only
major · p.7, p.8; Fig. 5, Fig. S4
The statement that "stable MTs were actually organized by motor-based polarity sorting" (p.7) and the Discussion's "same organizing mechanism" rest on similar banding and scaling. No motor was perturbed (dynein/kinesin inhibition or depletion), and polarity was never measured directly (EB comets, hook decoration, laser ablation); the Golgi position is an indirect proxy. The scaling is only qualitatively similar: band spacing is 24.9 µm (95% CI 21.3–29.9) in cells vs 16.6 µm in vitro (check 09). Fix: add motor perturbations and a direct polarity readout, or tone down the claim.
Fig. 5 statistics and ranges do not match the text
minor · p.7; Fig. 5G,H and caption
The text gives "13+/-5 and 77+/-33 µm²" for negative and positive domain areas. Digitized Fig. 5G gives positive mean 84.5, SD 68.2 µm² (n ≈ 89). A conservative SD lower bound of 41 already exceeds 33, and 9/89 points lie above mean + 3 SD. Negative: mean 14.6, SD 9.1 (check 07). Cell length is said to vary "up to twofold", but Fig. 5G spans 67–271 µm (4.1-fold) and Fig. 5H 67–229 µm (3.4-fold) (check 08). The two panels seem to use different cell sets, n is never given, the linear fits have no statistics, and the Fig. 5G caption says "length of microtubule bands" while the axis shows domain area. The ordering and the length-independence hold. Fix: report n, the exact statistics and the regression tests, and correct the text and caption.
Robustness of linear scaling overstated; Fig. S3 n mismatch
minor · p.6; Fig. S3 and caption (p.29)
p.6 says the linear increase "was robust to variations in the motor ratios (Fig. S3)". At 10/10 nM the KIF5B count plateaus at ≈2 (65→109 µm: +0.04 vs +1.55 predicted; R² = 0.72) (check 05). The panels show KIF5B domains only, although the caption says "motor domains". For 30/5 nM the in-plot label reads n = 49, but the caption says 81 (check 11).
Fig. 3 MT concentrations are ambiguous
minor · Fig. 3A,B and caption (p.19); p.5
Three labelings exist for the same experiment. The Fig. 3A images read 100/200/400/800 nM, the Fig. 3B axes 50/100/200/800, and the caption 50/200/400/800 nM (check 10). This is the axis from which "more MTs → more domains" is read, so which data column belongs to which concentration is unclear. The Fig. 3B n also differs between interface and count panels (70/58 vs 80/59). Motor concentrations, added tubulin and the resulting MT lengths are never reported, so "MT length" is never actually measured.
Simulation support is overstated
minor · p.4; Fig. S1C,D and caption (p.25)
p.4 says simulations "were sufficient to recapitulate all these observations". Fig. S1 covers R = 8–18 µm (201–1018 µm²) and ratios 0.25–10, i.e. at best 10 of the 24 Fig. 1 conditions. It does not cover the large-area inversion, ratio 20, ellipses/bars or sequential addition (check 17). No code or parameters are given, and the Fig. S1C caption states both axis assignments. Fix: give parameters and code, and limit the claim to the simulated range.
Text–caption inconsistencies in protocols and panels
minor · p.2–7; captions of Fig. 1, 3, 4, 5, S1, S4
Check 18 found 11 inconsistencies. The main ones: Taxol is 10 µM in the text and Fig. 5A but 5 µM in Fig. 5B–F/S4. Nocodazole is "overnight" in the text but 4 h in Fig. 5E,F/S4. The text's Fig. 3 panel letters are off by one relative to the caption. "Width-to-length ratio of 4" should be length-to-width. Sup. Fig. S4B is cited for an aspect-ratio series it does not contain. n differs between paired panels (Fig. 1D 8000 µm²: 6 vs 9; Fig. 4D: 20 vs 19). There are also typos ("organized mechanical forces", "can explained", "Figue S2").
Mis-cited theory and reference-list defects
minor · p.6; References (p.10–13)
"As expected from theory (43, 44)" cites two experimental papers on membrane-anchored kinesin transport and depletion-driven collective motion; neither contains a domain-size theory (check 16). Refs 51/52 seem intended. The bibliography also has placeholder page ranges ('1–13', '1–5', etc. in ≥ 9 entries), duplicated author lists (refs 17, 36, 68), a truncated title (63) and a missing venue (86).
Fig. 3A/B microtubule concentrations are 50, 200, 400 and 800 nM (caption)
Three different sets of concentrations are given for the same experiment. Fig. 3A image labels read 100, 200, 400, 800 nM MTs. Both Fig. 3B x-axes read 50, 100, 200, 800. The caption says 50, 200, 400, 800 nM, and its sample sizes (n = 84, 52, 70/80, 58/59) are attached to that set. Fig. 3C/D (100, 200, 400, 800) agree with their caption. It is therefore unclear which concentration each Fig. 3B data column represents, and this is the axis from which "more MTs → more domains" is read.
OCR (RapidOCR) of the Fig. 3 raster label strips and axis tick labels
Fig. S3 sample sizes n = 29, 53, 58, 81, 55 for 10/10, 20/10, 30/10, 30/5, 50/5 nM (caption)
In-plot labels read 29, 53, 58, 49, 55. For 30/5 nM the plot says n = 49 while the caption says n = 81; the other four agree. The caption also says each point is an individual confinement, but the panels show only means ± SD.
OCR (RapidOCR) of the (n=…) labels in the Fig. S3 plots, assigned to panel rows
Confinement areas in Fig. 2 are as stated (2A: 500 µm²), and centroid distances lie within the confinement; the Fig. 2D–G area is unstated
Fig. 2A discs measure 24.5–25.4 µm across (472–508 µm²), consistent with 500 µm². The Fig. 2D/2F discs are 36–40 µm across (≈1020–1290 µm²). That is roughly twice the Fig. 1–2A small size and matches none of the stated sizes (250/500/2000/8000 µm²), and the area is not given in text or caption. The Fig. 2G violins reach 16.9 and 16.2 µm, which fits those larger discs (R ≈ 18 µm). Open point: the Fig. 2B NCD violin extends to 13.8 µm, beyond R = 12.6 µm of a 500 µm² disc; this may be a kernel-density tail, but the plotting settings are not given.
Measured scale bars (10 µm) and the equivalent diameter of the bright disc in the raster panels. Read the violin tops from the y-axis tick calibration
Fig. 2 violins show "individual motor domain centroid positions relative to the confinement center" (caption), and the axes are annotated Centre/Periphery; the radial state has multiple peripheral KIF5B domains
Medians: Fig. 2C KIF5B (radial, 500 µm²) ≈2.7 µm; 2G-before KIF5B ≈4.9 µm; 2G-after NCD ≈4.0 µm (q1 2.3). Per-domain centroids of peripheral spots would sit at ≈11.1 µm (R = 12.6) or ≈16.9 µm (R = 18.4). The observed medians instead match pooled per-confinement centroids of 2–6 roughly evenly spaced spots: 1.3–1.9 µm (R = 12.6) or 2.0–2.8 µm (R = 18.4) with ±20° jitter, and 3.9–7.8 / 5.9–11.8 µm for uniform random angles. Fig. 2C n (40 NCD vs 27 KIF5B, despite several KIF5B domains per disc) also fits one value per confinement. The values therefore look like pooled centroids, which contradicts the caption. A pooled centroid cannot tell a central domain from symmetric peripheral domains, so the Centre/Periphery annotations in Fig. 2E/G do not show where domains are located; they show symmetry only.
Digitized the dotted median/quartile lines in the violins. Monte Carlo (seed 1, 20,000 draws): k = 1–6 rim spots in discs of R = 12.6 and 18.4 µm, comparing per-domain distance with the pooled per-confinement centroid
Fig. 4B monopolar/bipolar/multipolar frequencies are consistent with the caption sample sizes (500 µm²: n = 26, 7, 25, 7, 7, 19, 26, 7; 2000 µm²: n = 26, 26, 26, 24, 24, 28)
All 42 segments match a k/n fraction within 0.6 pp. 500 µm²: monopolar 17/26, 2/7, 4/25, 2/7, then 0 for AR ≥ 3. 2000 µm²: bipolar 0/26, 1/26, 2/26, 12/24, 15/24, 18/28. Bar heights are internally consistent with the stated n. Caveat: four 500 µm² conditions (AR 1.5, 2.5, 3, 34) rest on only 7 confinements, and the 2000 µm² bipolar fraction plateaus at ≈63% for AR 15–60. Bipolar organization is favoured but not universal even in the most elongated shapes.
GRIM-style test: read the colour-run boundaries along each bar centre against the y-axis ticks, then found the nearest k/n for each segment (tolerance 1.5 pp; 1 px ≈ 0.65 pp)
Sequential motor addition produced configurations "not observed when they were mixed from the outset at any ratio, including … multiple peripheral minus domains" (hysteresis, Discussion)
With motors mixed at the outset, every disc had ≥ 2 NCD (minus) domains at ratio 1 for 8000 µm² (levels 6–11, mean ≈7.8) and 2000 µm² (levels 3–6, mean ≈4.4), and at ratio 2 for 8000 µm² (levels 4–9, mean ≈6.1). Fig. 1C (bottom row) shows these as peripheral domains, and p.4 itself describes "a large central plus-domain with multiple small peripheral minus-domains". In Fig. 4B, 26/26 circular 2000 µm² confinements at 10/10 nM were multipolar. Multiple peripheral minus-domains therefore do form without sequential addition. The claim could hold only for the unstated ≈1000–1300 µm² discs of Fig. 2D–G (check 12), which Fig. 1 does not test. As written ("at any ratio"), the hysteresis claim is not supported.
Digitized the Fig. 1D NCD-count scatter at ratios 1 and 2 (integer dot levels and mean lines); reused the Fig. 4B 2000 µm² circle frequencies (check 14)
"Confirming that the biochemistry sets the size of the domains as expected from theory (43, 44)"
Ref 43 (Grover et al., PNAS 2016) is an experimental gliding-assay study of membrane-anchored kinesin-1 transport efficiency vs motor density and diffusivity; its abstract has no hits for domain/theory/length-scale keywords. Ref 44 (Inoue et al., Nanoscale 2015) is an experimental study of depletion-force-induced collective MT motion. Neither contains a theory of motor-domain size. Ref 51 (Utzschneider et al., PNAS 2024: "experiments on reconstituted systems and theory", opposing membrane-bound motors, segregated domains) and presumably ref 52 (Pattanayak et al., PRL 2026; abstract lookup rate-limited) are the relevant theory. The citation appears to point to the wrong references.
Retrieved titles and abstracts of refs 43, 44 and 51 from Europe PMC and searched them for domain-size, length-scale, phase-separation or theory content
Numerical simulations with motors of different strengths "were sufficient to recapitulate all these observations" (Fig. S1, movie S8)
Simulated R = 8–18 µm (201–1018 µm²) and NCD/KIF5B = 0.25–10. Only the 250 and 500 µm² experimental areas fall inside the simulated range: 10 of 24 Fig. 1 conditions, at best, and ratios 2, 3 and 6 lie between sampled values. The large-area inversion (2000/8000 µm²), ratio 20, the ellipses and bars (Fig. 4) and sequential addition (Fig. 2D–G) are not simulated. "All these observations" overstates what Fig. S1 shows. Verifying it would need the modified cytosim code, its parameters (motor force and speed, numbers, MT length) and run counts. Several Fig. S1D points have no error bars, so n is unclear.
OCR of the Fig. S1 axis labels to get the simulated radii and ratios, then computed the coverage of the experimental parameter space. The simulation itself cannot be rerun: no code, parameters or Methods section are provided
Protocol parameters, panel references and sample sizes are consistent between the main text and the figure captions
11 inconsistencies. (1) Taxol: 10 µM in the text (p.6) and Fig. 5A vs 5 µM in Fig. 5B–F and S4. (2) Nocodazole: overnight in the text vs 4 h in Fig. 5E/F and S4. (3) The text cites Fig. 3D,E and 3F,G,H for tubulin addition, but the caption places these panels at E,F and G,H. (4) Fig. 3B n: 84/52/70/58 (interface) vs 84/52/80/59 (NCD count). (5) Fig. 4D n at 20:1: NCD 20 vs KIF5B 19. (6) Fig. 1D at 8000 µm², 10/10 nM: NCD n = 6 vs KIF5B n = 9. (7) The Fig. S1C caption gives both axis assignments. (8) "Width-to-length ratio of 4" should be length-to-width. (9) Sup. Fig. S4B is cited for the aspect-ratio series but shows 12 µm lines. (10) The Fig. 5G caption says "length of microtubule bands", but the axes show domain area. (11) Fig. S1 refers to Materials and Methods, which the preprint does not contain.
Regex extraction from the paper text, printing each pair of conflicting statements with line numbers
With increasing NCD in near-linear 2000 µm² ellipses, minus-domains become larger and fewer, "eventually down to a single central minus-domain" (20:1, 50/2.5 nM)
At 20:1 the NCD domain counts in Fig. 4D span 4–11 (mean line ≈6.3, n = 20). No ellipse has a single NCD domain; the minimum is 4. The mean NCD domain length at 20:1 is ≈62.8 µm (Fig. 4E), about one sixth of the ≈380–390 µm ellipse. The text claim of a single central minus-domain is not supported by the paper's own quantification; it describes at most the one image in Fig. 4C (bottom row). Numbers fall fewer only from 6:1 (≈12.5) to 20:1 (≈6.3).
Digitized the Fig. 4D NCD-count scatter (integer dot levels, y calibrated on the 0 and 20 ticks) and the Fig. 4E NCD-length mean lines from the 220-ppi raster
Plus-domains alternate with minus-domains along near-linear ellipses, and their number follows the opposite trend to minus-domains
Mean N_NCD vs N_KIF5B: 1:1 2.56 vs 1.64; 2:1 10.00 vs 9.08; 3:1 10.56 vs 9.95, all consistent with NCD at both tips. 6:1 12.51 vs 13.95 (Δ = +1.44, marginal); 10:1 8.00 vs 12.62 (Δ = +4.6); 20:1 6.26 vs 13.90 (Δ = +7.6). From 6:1 to 20:1 the NCD count halves (12.5 → 6.3) while the KIF5B count is unchanged (14.0 → 13.9). That contradicts both the opposite-trend statement and an alternating partition. At high ratios the counted KIF5B domains cannot all be partitions that alternate with NCD domains, so the domain definition and segmentation need to be explained.
Digitized Fig. 4D mean lines for the NCD and KIF5B counts. In a 1D alternating partition the two counts in each ellipse differ by at most 1, so the condition means must satisfy |ΔN| ≤ 1 (digitization tolerance ±0.3)
"The respective sizes of plus and minus-domains accurately reflected the ratio of the corresponding motors"
L_NCD/L_KIF5B (motor ratio in brackets): 0.06 (1), 1.02 (2), 1.17 (3), 4.24 (6), 10.3 (10), 19.9 (20). The size ratio tracks the motor ratio only from 6:1 upwards. At 1:1–3:1 it is off by factors of 15.5, 2.0 and 2.6. NCD and KIF5B domains have almost equal size at 2:1 and 3:1 (15.0 vs 14.7 µm; 20.9 vs 17.9 µm). The claim holds for 6:1–20:1 only, and the low-ratio data also sit uneasily with the p.4 argument that the weaker NCD needs larger domains. Digitization uncertainty is ≈±0.5 µm (main) and ±0.3 µm (inset), far smaller than the deviations.
Digitized the Fig. 4E mean lines (NCD 0–100 µm axis; KIF5B 1:1 from the midpoint of the ±SD caps on the 0–400 µm axis; KIF5B 2:1–20:1 from the 0–30 µm inset). Computed L_NCD/L_KIF5B and compared it with the NCD:KIF5B concentration ratio; criterion: within a factor of 1.5
The Fig. 4C–E ellipses are "highly elongated" 2000 µm² confinements, and the reported domain counts and lengths are consistent with their length
The measured Fig. 4C ellipse length is 381–388 µm, consistent with a 2000 µm² ellipse of aspect ratio ≈60 (predicted long axis 391 µm, width 6.5 µm). The aspect ratio is not stated for Fig. 4C. ΣN·L = 470, 284, 399, 388, 412 and 437 µm for 1:1–20:1 vs ≈384 µm, i.e. +22%, −26%, +4%, +1%, +7%, +14%: within tolerance. The −26% at 2:1 leaves ≈100 µm unaccounted for (MT bands?). The check supports the geometry and gross internal consistency only, not the domain definition (see check 02).
Computed ellipse axes from area and aspect ratio. Measured the Fig. 4C ellipses against the 10 µm scale bar (31 px). Summed N·L for both motors from the digitized Fig. 4D/4E means (tolerance 30%)
"This linear increase of domain number with pattern length was robust to variations in the motor ratios (Fig. S3)"
Linear for 4 of 5 ratios: 50/5 R² = 0.990, 30/5 0.983, 30/10 0.996, 20/10 0.961, with slopes of 0.022–0.035 KIF5B domains/µm. At 10/10 (1:1), the means are 0.01, 0.10, 0.79, 1.68, 1.99, 2.03 for 6–109 µm (R² = 0.72). The 65→109 µm increment is +0.04 against +1.55 predicted, a plateau at 2 domains. The robustness statement does not hold at the lowest ratio. The panels also plot only KIF5B domains, while the caption says "motor domains".
Digitized the mean points of the 5 Fig. S3 panels (per-panel y calibration on 8 ticks). Fitted a line for L ≥ 12 µm and compared the observed 65→109 µm increment with the increment predicted from the 12–65 µm slope
Above a critical bar length the domain size stops growing (≈15 µm at NCD:KIF5B 3:1), and the number of MT bands increases proportionally with length
Mean domain length for L ≥ 43 µm is 14.9 µm (NCD 13.1, 14.4, 15.4; KIF5B 17.6 and 14.1 where visible) vs the stated 15 µm. NCD still creeps up by ≈2 µm between 43 and 109 µm, so the plateau is soft. N_bands = 1.10, 1.22, 1.60, 2.43, 3.60, 6.76 at 6–109 µm. N/L is 0.056, 0.055, 0.062 µm⁻¹ for L ≥ 43; a linear fit gives an intercept of −0.01 and a spacing of 16.6 µm. Predicted bands agree within +0.03 to +0.53. Three KIF5B means are hidden under NCD dots and could not be read.
Colour-segmented the cyan (NCD) and magenta (KIF5B) mean dots and the black band-number dots in Fig. 4G; calibrated on the axis ticks. Tested the plateau value, N/L, and the alternating-partition prediction N_bands ≈ L/mean domain length − 1 (tolerance ±1 band)
Negative domains are smaller than positive domains (13 ± 5 and 77 ± 33 µm²), and domain size is independent of cell length
Positive: digitized mean 84.5, SD 68.2 µm² (n ≈ 89, range 8.9–310.6). The conservative lower bound of 41.0 already exceeds the claimed SD of 33 by more than the 20% tolerance, and 9/89 points lie above 176 (claimed mean + 3 SD). Negative: mean 14.6, SD 9.1 µm² (n ≈ 101, range 0.8–42.0); the lower bound of 5.6 is compatible with the claimed 5, but the point estimate is ≈1.8× larger. SDs of per-cell means (72.6 and 6.4) do not reproduce 33/5 either. The ordering negative < positive and the independence from cell length are supported: Spearman ρ = +0.03 (p = 0.75) and +0.11 (p = 0.27). n is not reported in the paper. Overlapping dots make n and SD approximate.
Colour-segmented the pink and blue dots in Fig. 5G with both axes calibrated on ticks. Split merged blobs by area. Computed mean, SD and Spearman ρ, plus a conservative SD lower bound (isolated dots only, sum of squares about the claimed mean divided by 2× the estimated n)
On 12 µm lines cell length "varied up to twofold"
Fig. 5G cell lengths span 67–271 µm (max/min = 4.07, pink; 4.05, blue). Fig. 5H spans 67–229 µm (3.42). Both are well above the stated twofold (tolerance 2.3). The longest cells in Fig. 5G (≈271 µm) are absent from Fig. 5H, so the two panels appear to use different cell sets, which the captions do not explain.
Read cell lengths from the x-positions of the Fig. 5G dots (pink and blue) and the green Fig. 5H dots, with x calibrated on the 0/100/200/300 ticks
The number of domains and MT bands increases linearly with cell length (Fig. 5H), paralleling the in-vitro scaling (Discussion)
Bands: count = 0.63 + 0.0402·L, R² = 0.80, p = 4e-13 (≈35 digitized points). Negative domains: 0.89 + 0.0193·L, R² = 0.59, p = 2e-5. Bands ≈ 2·N_neg − 1 at 100/150/200 µm (4.65 vs 4.63; 6.67 vs 6.56; 8.68 vs 8.49), consistent with alternating positive and negative domains. A linear increase is supported, but the paper reports no statistics. Band spacing in cells is 24.9 µm (95% CI 21.3–29.9) vs 16.6 µm in vitro (Fig. 4G, 3:1), so the scaling is qualitatively, not quantitatively, similar. With the claimed mean areas, domains cover only ≈20% of the cell area; this is plausible if domains are the gaps between wide MT bands, but the paper does not define domain area, and the Fig. 5G caption calls it "length of microtubule bands".
Colour-segmented the green (bands) and blue (negative domains) dots in Fig. 5H and calibrated the axes. Ran OLS regression with slope, R² and p, then compared the band spacing with the in-vitro value (check 06)