A fast, openly released phone-NPU mesh regressor whose speed and accuracy tables are internally consistent. However, three claims go further than the evidence: the 3DPW “match” with NLF-S comes from the crop, not the fit; the 23 mm commercial-data gap is confounded with augmentation and schedule; and the released benchmark cannot reproduce the fit rows.
Soundness
3/4
Presentation
3/4
Contribution
3/4
Confidence
4/5
✓ 10 confirmed✕ 6 discrepancy◐ 1 inconclusive
Summary
The paper presents InstantHMR, a family of four single-image human mesh regressors (N/T/S/M). Each uses an HGNetV2 backbone and a small DETR-style decoder, predicts the Momentum Human Rig (MHR), and is trained only on the public SAM 3D Body pseudo-annotations. The design goal is phone NPUs. InstantHMR-M runs at 5.49 ms per person on a Galaxy S23 NPU, which the paper reports as 12× faster than NLF-S and 23× faster than NLF-L. It reaches 48.8 / 40.0 / 41.7 mm PA-MPJPE on EMDB-1 / 3DPW / RICH.
The second contribution is an optional kinematic fit inside the exported graph: one fp16 Levenberg–Marquardt step over 68 body unknowns, driven by the network's own 2D keypoints, with the normal equations inverted by 10 Newton–Schulz iterations. Optionally a second crop is fused in. The paper reports that the fit brings M to NLF-S accuracy on EMDB-1 and 3DPW at 6.40 ms, 10.6× faster than NLF-S.
The third contribution is a matched evaluation protocol. Eleven competitors are re-scored with Meta's MHR→SMPL conversion and timed on eight hardware targets. The supplement quantifies each protocol choice, compares strided with full-frame scoring, checks reproductions against published numbers, and reports a sustained on-device run with power measurements.
Strengths
Strong, practically relevant speed result, consistent across tables
Abstract; Sec. 1; Sec. 5 'Speed'; Table 1
Every headline ratio recomputes from Table 1: 67.97/5.49 = 12.38 (12×), 125/5.49 = 22.77 (23×), 67.97/6.40 = 10.62 (10.6×) and 67.97/10.22 = 6.65 (6.7×). All S23 grey speed factors match to the nearest integer (check 01). Only InstantHMR and SMPLer-X-S32 are real time on the phone NPU among the methods that run there, and InstantHMR is 22 mm more accurate on EMDB-1 (check 06). The NPU analysis in Sec. 5 (71% of NLF's NPU time in gathers, reductions and transposes) explains why the architecture choice matters, which is useful beyond this paper.
Unusually broad and honest latency measurement
Table 1; Sec. 5 'Android app'; Supp. 'On-device' (tab:supp-device-latency, tab:supp-device-runs)
Latency is reported on eight targets: TensorRT, ORT GPU/CPU, two phone NPUs and two phone CPUs. It is complemented by a real Android app with crop/model breakdown, a sustained 5-minute replay and a 342 s live run with power draw and battery drop. Our recomputation of the on-device bookkeeping agrees closely: 7.41 − 6.40 = 1.01 ms overhead, 1.66 W/30 = 55.3 mJ per frame, and battery drops implied by mean power within integer-reading tolerance (check 14).
Careful, quantified evaluation protocol
Sec. 4; Supp. tab:supp-protocol, tab:supp-stride, tab:supp-as-published
Competitors are re-scored under one protocol. The supplement then quantifies what each choice does. Detector boxes vs GT boxes move every size by 1.7–2.3 / 0.7–1.4 mm, stride-10 vs every frame by at most 0.30 mm, and reproductions sit within 1.3–4.5 mm of the published numbers. Methods trained on 3DPW or RICH are flagged. All of these deltas recompute exactly from the LaTeX tables (check 11). This kind of protocol accounting is rare in the HMR literature and makes the cross-method comparison more trustworthy.
Fully specified, correctly implemented kinematic fit
Sec. 3.3; Supp. 'Kinematic fit'; training/kinematic_fit.py; Table 3
The constants in Sec. 3.3 and the supplement match training/kinematic_fit.py exactly: prior 30/0.01, μ = 1e-3, 10 NS iterations, 68 unknowns, J of size 60×68. The analytic Jacobian agrees with finite differences to 4.9e-7. The 1/16 and 1/256 fp16 scaling leaves the exact step unchanged, and without it overflows fp16 at the σ floor. The released fp16 graph matches an fp64 re-implementation to ≤ 0.0062 rad, and the fit reduces reprojection error from 2.8–4.5 px to ≈ 0.85–0.96 px on real crops (checks 04, 08). The added cost is 0.91 ms on the S23 and 0.14 ms on TensorRT (check 15).
Weaknesses
The 3DPW “match with NLF-S” is produced by the crop rescale, not the kinematic fit, and the EMDB-1 match is a single-run sub-mm difference
major · Abstract; Sec. 5 'Accuracy' (5_experiments.tex:27); Table 2; Table 4
The abstract and Sec. 5 credit the fit with matching NLF-S on EMDB and 3DPW (45.2 vs 45.0; 39.4 vs 39.4). Table 4, however, shows the 0.9 crop without the fit already reaches 39.2 mm on 3DPW, which is better than crop + fit (39.4). On top of the crop, the fit is 0.2 mm worse on 3DPW (checks 02, 03). NLF-S also remains better on 3DPW MPJPE (62.2 vs 63.2) and PVE (74.6 vs 75.1), and on RICH by 6.1–6.9 mm. All of these differences are single-run and sub-millimetre, with no seeds or confidence intervals. The crop scale was also selected on 3DPW validation data. Fix: attribute the 3DPW gain to the crop, state the per-metric picture, and report variance over seeds (or bootstrap CIs over sequences) before calling 0.2 mm a match.
The conclusion that “training images matter more than any architectural change” is confounded
major · Sec. 5 'The family' (5_experiments.tex:36); Sec. 6; Table 3; Supp. tab:supp-design
The 23.4 mm EMDB-1 gap between M and M-C is correct (72.2 − 48.8). But the released run configs show that M-C also differs in other respects. It used window_mode 'standard', with no 75 % framing mix, and training/README.md says it stopped at epoch 532 of 600 (check 05). The paper's own design ablation (tab:supp-design) attributes 10.0 mm on EMDB-1 (58.8 vs 48.8) to standard-crop-only training with the same data, about 43 % of the gap. The headline lesson repeated in Sec. 6 is therefore not supported as stated, and the differences are not disclosed. Fix: retrain M-C with the same framing mix and schedule, or restate the gap as data + augmentation + schedule and disclose the differences.
The released benchmark cannot reproduce the fit and 0.9-crop rows of Tables 2 and 4
major · Tables 2 and 4; Sec. 4; benchmark/evaluate.py; instanthmr/inference.py:16–21,170–178
benchmark/evaluate.py has no --fit or crop-scale option, and resolve_model defaults to fit = 0. When a fit graph is passed by path, InstantHMR.predict always enlarges the given box by DETECTOR_TO_GT_BOX = 1/0.866 (inference.py:176), including ground-truth boxes. We instrumented the crop. The effective scales are 1.039 (fit1) and 1.039/0.808 (fit2) instead of the 0.9 and 0.9/0.7 the paper evaluates (check 09). The paper's own validation sweep shows that framing changes 3DPW PA-MPJPE by ~1.5 mm, which is larger than the fit-vs-NLF-S differences being claimed. The network-alone rows (48.8 / 40.0) are reachable with the release, but we could not rerun them (no EMDB/3DPW/SMPL data). add fit and crop-scale options that bypass the detector factor for GT boxes, and document the exact commands for every row.
Questions for the authors
Was M-C trained with the same crop-framing mix and full 600-epoch schedule as M? If not, how large is the gap when only the training images differ?
With the fit and 0.9 crop on 3DPW, does any setting of the fit (e.g. a different prior weight) improve on the 39.2 mm of the crop alone, or does the fit only help on EMDB-1 and RICH?
How much do the Table 2 numbers vary across training seeds? Is the 0.2 mm EMDB-1 gap to NLF-S within that variation?
Which exact commands and box handling produced the fit rows of Tables 2 and 4, given that InstantHMR.predict enlarges GT boxes by 1/0.866 for fit graphs?
Were the crop scales (0.9, 0.7) and the checkpoint chosen on any split overlapping the 3DPW or EMDB test sequences?
How were the 342 s and 10,409 frames of the live run measured, and does the count include the warm-up?
Verification
We ran 17 checks with 18 scripts. Confirmed (10): headline speed ratios; accuracy gaps and the fit-vs-NLF-S inequalities; the fit-ablation deltas; the family trends; the PA-MPJPE implementation (matches Umeyama to 1e-11 mm); the protocol and stride tables; the training mix and all 11 loss weights; the oracle and fit-cost numbers; and the kinematic fit. For the fit, we ran the released code with Meta's MHR rig and the released fp16 ONNX graph on real crops. Its constants, Jacobian and fp16 scaling are correct, but 10 NS iterations give only an approximate inverse. Discrepancies (6): the M-C attribution is confounded by augmentation and schedule; the released benchmark crops GT boxes at 1.039× instead of 0.9 for fit graphs; 'no added latency' contradicts the 13 ms lag stated in the supplement; the live-run frame count and duration disagree by 1.4 %; the README and paper differ in small latency values and box factor; and three references have metadata issues. Inconclusive (1): the benchmark numbers themselves (EMDB/3DPW/SMPL data unavailable), though the released model runs end to end and parameter counts match (tiny 20.36 M printed as 20.3). Most discrepancies are small; the two that matter qualify secondary conclusions and the reproducibility of the fit rows, not the core speed/accuracy result.
10Confirmed
6Discrepancy
1Inconclusive
✓ConfirmedAbstract; Sec. 1 (sec/1_intro.tex:20); Sec. 5 Speed/Accuracy; Table 1 (tab_speed.tex); Table 2 latency columns
[24] Jiefeng Li et al. GEM: A generalist model for human motion. In ICCV, 2025.
Title mismatch: the ICCV 2025 paper (arXiv 2505.01425, DOI 10.1109/iccv51701.2025.01094) is titled 'GENMO: A GENeralist Model for Human MOtion'. 'GEM' is the later name of its code repository (renamed Dec 2025). The paper also names the same work inconsistently: 'GEM' in sec/2_related.tex:33 and 'GENMO' in tables/supp_as_published.tex.
[51] Yanis Zaoui, Valentin Begel, and Mohamed Adjel. Rhythmic fitness beat 'em all using real-time monocular human pose estimation. In ICEC, 2026.
Venue not verifiable: only an arXiv preprint (2611.09228, Nov 2026) was found, with no ICEC 2026 proceedings record (Crossref best match is an unrelated paper). It is a self-citation (NaturalPad, the organisation that hosts the InstantHMR code) and is cited only as an application example, so it is not load-bearing.
[29] Soroush Mehraban, Andrea Iaboni, and Babak Taati. FastHMR: Accelerating human mesh recovery via token and layer merging. In WACV, 2026.
Truncated title: the WACV 2026 paper (DOI 10.1109/wacv61042.2026.00651) is 'FastHMR: Accelerating Human Mesh Recovery via Token and Layer Merging with Diffusion Decoding'. Minor.
Suggestions
Rephrase the abstract and Sec. 5 so the 3DPW parity with NLF-S is credited to the crop rescale. Give the full per-metric comparison (MPJPE/PVE on 3DPW and RICH favour NLF-S).
Report mean ± std over at least three training seeds, or bootstrap CIs over sequences, for the rows that are compared at sub-millimetre resolution (Table 2 fit rows vs NLF-S/NLF-L).
Retrain M-C with the same framing mix and schedule as M, or restate the 23 mm gap as data + augmentation + schedule. Disclose the configuration differences in Table 3.
Add --fit {0,1,2} and --crop-scale options to benchmark/evaluate.py, skip the detector-to-GT enlargement when GT boxes are given, and list the command for every table row.
Describe the 10-iteration Newton–Schulz solve as an approximate inverse, and report its residual ∥I−X10 or the step deviation from the exact LM step on the benchmarks.
Ethics and integrity
No integrity concerns were found. All recomputed values agree with the tables apart from the small inconsistencies listed. The paper discloses use of an LLM coding assistant. Reference [51] is a self-citation to a work from the code-hosting company (NaturalPad) listed as ICEC 2026, for which only an arXiv preprint was found. It is not load-bearing. No embedded instructions to reviewers were found in the source, PDF or code.
Scope of this review
We could not rerun the EMDB-1, 3DPW, RICH or EgoHumans benchmarks: the datasets and the SMPL model files need registration and were not available. Numbers in Tables 2–4 were therefore checked for internal consistency and against the released configs, not regenerated. We did not retrain any model, so the M-C confound is shown from the released configs and the paper's own ablation, not from a controlled retraining. Device latencies (Qualcomm AI Hub, S23/S24 NPUs, TensorRT) and the on-device power runs could not be re-measured. Our CPU timings on a 2-core runner are not comparable. Competitor reproductions were taken from the paper's tables.
Open, runnable release that matches the paper's specification
Sec. 3; Supp. tab:supp-losses; README.md; HF momolesang/InstantHMR
The repository runs end to end on CPU with the released ONNX graphs, and outputs are finite and correctly shaped (check 08). Parameter counts match for N/S/M/M-C. The training mix (43/26/14/13/4 %) and all 11 loss weights in tab:supp-losses agree with the released run_config.json files and train.py at printed precision (check 12). A commercially usable variant (M-C) is also released.
Limitations are stated and partly quantified
Sec. 6; Sec. 5 'Crop scale and kinematic fit'; Supp. tab:supp-oracle
The paper names the missing hand branch, the Qualcomm-only deployment and the M-C accuracy gap. The EgoHumans oracle (+0.4/+0.7 mm with the network's own 2D keypoints vs +17.1/+6.1 mm with GT 2D keypoints) shows where the fit's ceiling is (check 15).
Fix:
Newton–Schulz with 10 iterations is an approximate, not exact, inverse
minor · Sec. 3.3; Supp. 'Kinematic fit' (NS iteration)
The method reads as one exact LM step. Measured on the released code, the Jacobi-scaled H has a condition number of ~700. The NS(10) step deviates from the exact LM step by 5.7 % median (max 8.5 %) on 12 real crops and by 8 % median (max 40 %) on synthetic problems (check 04). The practical effect on real crops is small: ≤ 0.6 mm in root-relative 3D keypoints and the same reprojection error. Still, the text should describe X10 as an implicitly regularised approximate inverse and report its residual.
“Faster than every method we evaluate” does not hold on every target
minor · Abstract; Table 1
On ONNX Runtime fp32 on the RTX 4070, NLF-S takes 3.71 ms against 4.42 ms for InstantHMR-M (Table 1; check 01). The claim holds for 7 of 8 timing columns. Qualify the abstract, e.g. “on phone NPUs and TensorRT”.
The 1 Euro filter is said to add “no latency” but also to add ~13 ms of lag
minor · Sec. 5 'Temporal'; Supp. supp_body.tex:323–329, tab:supp-temporal
Sec. 5 (5_experiments.tex:54) and supp_body.tex:323 say the causal filters add no latency. supp_body.tex:327 says the 12 Hz cut-off gives a lag of about 13 ms (0.4 frame). Our computation and simulation agree with the latter: τ = 1/(2π·12) = 13.3 ms, and the simulated lag is 11.0–13.2 ms on ramps (check 13). The filter adds no buffering delay but does add output lag. The acceleration-error comparison with NLF-S (15.2 vs 21.2) should be read with that trade-off stated.
Live on-device run: frame count, duration and FPS are inconsistent
minor · Supp. tab:supp-device-runs; Sec. 5 (5_experiments.tex:14)
tab:supp-device-runs reports 10,409 frames in 342 s at “30.0 FPS”. 10,409/342 = 30.44 FPS, while 342 s × 30 FPS = 10,260 frames, i.e. 149 fewer (1.4 %, beyond rounding; check 14). Possibly part of the warm-up was counted. State how frames and duration were measured. This does not affect the real-time conclusion.
Paper and release disagree in several small details
minor · Supp. supp_body.tex:191–197; Sec. 3 (3_method.tex:13); Sec. 4; README.md; benchmark/evaluate.py:95; instanthmr/inference.py:16–21
The paper uses a detector-to-GT box factor of 1/0.86 for YOLO11n-pose, while the code and README use 1/0.866 for RF-DETR, so the detector-box numbers come from a different detector than the released demo. Four S23 fit latencies differ by 0.01–0.03 ms between README and Table 3. The tiny model has 20.36 M parameters, printed as 20.3 (should be 20.4). 3DPW boxes are “enlarged by 20 %” in the text but padded by 0.2·w on each side (×1.4) in evaluate.py:95. The fallback focal comment says ~50°, but 1.05× diagonal gives 45.1° (checks 08, 09, 16).
Dependence on SAM 3D Body pseudo-labels is not discussed
minor · Sec. 3 'Training'; Sec. 6
All training supervision comes from SAM 3D Body pseudo-GT, so InstantHMR's accuracy is bounded by, and its errors are likely correlated with, those of its teacher. SAM 3D Body is also one of the compared methods (8.5 mm better). The paper does not analyse this ceiling or its failure modes, e.g. how the 8–10 mm gap to SAM 3D Body / Fast SAM 3D Body splits between capacity and label noise.
Grey speed factors mix integer and one-decimal rounding: 5.62 → “6×” next to “1.4×” and “1.6×”, and 416/0.98 = 424.5 → “425×” (check 01). The second crop is presented as the default (--fit 2), but on RICH it is neutral or worse than one crop for T/S/M (check 07). Reference [24] is cited as “GEM”, while the published ICCV 2025 title is GENMO, and the same work is called GENMO in supplementary tables (check 17).
PA-MPJPE is computed after a Procrustes (similarity) alignment, MPJPE/PVE after mid-hip rooting.
The aligned joints match Umeyama to max 1.1e-11 mm in all cases, and PA errors agree to 1.8e-12 mm. Exact similarities give 0.000 mm. The scipy disparity agrees to 4.5e-17 on non-mirrored sets. It differs only on mirrored predictions (0.81), because scipy allows reflections while the released code forces det(R)=+1, as intended. No perturbation out of 2000 lowers the squared error, and a zero-variance prediction stays finite. MPJPE/PVE subtract each set's own root: the mean of SMPL joints 1 and 2 (mid-hip) for the 24-joint set, and the J14 hips (indices 3, 2) for the 14-joint set. The value is unchanged (975.7184) after translating the prediction by 777 mm. Tolerance 1e-6 mm.
Compared the released similarity_transform/pa_mpjpe with an independent Umeyama (1991) implementation and scipy.spatial.procrustes on 200 random 24-joint sets per case (exact similarity, noisy, mirrored). Checked optimality with 2000 random perturbations of R, s, t, the zero-variance guard, and that mid-hip-rooted MPJPE is invariant to translation.
Protocol choices: detector boxes improve every size by 1.7-2.3 mm (EMDB-1) and 0.7-1.4 mm (3DPW); stride-10 vs every frame differs by at most 0.30 mm; NLF-L reproduces 1.9-2.2 mm better than its paper, others 1.3-4.5 mm worse.
Detector-box gains per size N/T/S/M: EMDB-1 2.3/1.7/1.9/1.9, 3DPW 1.4/1.0/1.4/0.7, giving 1.7-2.3 and 0.7-1.4 as stated. M-C gains are 1.9 and 2.9 as stated. Surface-map costs are 0.9-1.1 (EMDB-1) and 1.0-1.4 (3DPW). Fast's network costs are 11.7-17.0 and 2.5-3.8. The 55 deg FOV changes PA by at most 0.4. All eight stride deltas match their printed values. The maximum |dPA| is 0.30 (IHMR-M, 3DPW, J24), and the EMDB-1 maximum is 0.06. Reproduction gaps: NLF-L -1.9 (EMDB-1) and -2.2 (3DPW). SAM 3D Body +2.1/+1.3, Fast SAM 3D Body +1.3/+3.7, HybrIK +3.6/+4.5, CameraHMR EMDB-1 +3.0, MeshPose 3DPW +3.0 (paper says 2.9, 'approximate' because of the LSP joint set). Worse-than-published therefore spans 1.3-4.5, as stated. NLF-S (+0.1/+0.9), TokenHMR (-0.9/-0.3) and HMR2.0b (-0.8/-0.2) are within 1 mm, as stated. Caveat: the paper says these gaps use 'the joint set of each paper', while this recomputation uses Table 2's joint sets. All values agree anyway. Not a discrepancy, but the framing 'competitors reproduce their published numbers' covers gaps of up to 4.5 mm, about as large as some of the method gaps in Table 2.
Parsed the LaTeX tables and recomputed every per-size delta, the stride deltas and the reproduction gaps (our PA from tab_accuracy, EMDB-1 J24 / 3DPW J14, minus the published PA). Tolerance 0.05 mm.
Training mix 43/26/14/13/4 % (SA-1B/AIC/Harmony4D/COCO/MPII) and the loss weights of tab:supp-losses (theta_loc 0.96, root rotation 0.0074, ...) are what the code uses.
N/T/S/M mix sa1b=0.30, aic=0.18, harmony4d=0.10, coco=0.09, mpii=0.03 (sum 0.70) normalises to 42.86/25.71/14.29/12.86/4.29 %, which rounds to 43/26/14/13/4 as stated (tolerance 0.5 pp). All 11 loss weights match the table at its printed precision. theta_loc = 130/136 = 0.95588 (0.96). Root = (6/136)·(1/6) = 1/136 = 0.0073529 (0.0074) on (1/4)||R-R*||_F^2. The remaining weights are exact: scales 0.1, identity 0.03, cam 0.1, 3D keypoints 0.35, vertices 0.35, skeleton 0.001, SimCC 1, 2D 10, reprojection 0.01. Pose SmoothL1 beta is 0.05 rad, and kp3d_loss is 'euclid' as stated. As noted in check 05, M-C uses a different mix (harmony4d 0.75 / coco 0.25) and window_mode 'standard'. Loss weights: work/verify/14_loss_weights.py.
Normalised the --mix weights of every released run_config. Read the effective loss weights of the medium run (run_config, then apply_rebalanced_losses, then TrainConfig defaults) and converted the code's proportional pose split and chordal root loss into the paper's parameterisation.
Temporal: accel error 27.1 (M), 21.2 (NLF-S), 22.5 (2-crop fit), 15.2 with a causal 1 Euro filter (15.7 on 3DPW vs 18.4 NLF-S), 'with no added latency and a 0.1-0.3 mm better PA-MPJPE'; 1 Euro accel error '10% lower' and jitter '12-13% lower' than alpha-beta.
All numbers are consistent. The main-text values (27.1, 21.2, 22.5, 15.2, 15.7, 18.4) match the table. 1 Euro vs alpha-beta acceleration error is 10.4/10.0 % (1 crop) and 10.6/9.8 % (2 crops) lower, i.e. '10 %'. Jitter is 11.9/12.7 % and 12.8/11.8 % lower, i.e. '12-13 %' after rounding; the minimum 11.8 rounds to 12. PA gains are 0.1-0.3 mm as stated. The discrepancy is the latency wording. The main text says 'with no added latency' (5_experiments.tex:54), and supp_body.tex:323 says 'All filters are causal ... so none adds latency'. Two lines later, supp_body.tex:327 says the 12 Hz cut-off 'gives a lag of about 13 ms (0.4 frame)'. The computation agrees with the latter: tau = 1/(2pi12 Hz) = 13.3 ms, alpha = 0.715 at 30 FPS, and the EMA ramp lag is 0.398 frame = 13.3 ms. The simulated filter lags 13.2/12.7/11.0 ms (0.40/0.38/0.33 frame) at 0.1/1/5 rad/s. The filter adds no buffering delay but does add about 0.4 frame of output lag, so 'no added latency' is inaccurate. Minor wording issue, internally inconsistent.
Recomputed the percentages and PA gains from tab:supp-temporal and its caption. Computed the time constant of the 12 Hz minimum cut-off at 30 FPS and simulated the stated tuned 1 Euro filter (12 Hz, beta 0.5, d cut-off 1 Hz) on ramps of 0.1/1/5 rad/s to measure the steady-state lag.
On-device app: frame 12.73 ms median = 5.21 ms crop + 7.41 ms model, '1.0 ms more than on AI Hub'; 30.0 FPS with 2 of 8,996 frames dropped (replay, 5 min) and 1 of 10,409 (live, 342 s); +1.66 W above idle = '55 mJ per frame'; fp16 within 2.9 mm of fp32.
Most numbers are consistent. 7.41 - 6.40 = 1.01 ms ('1.0 ms more'). 5.21 + 7.41 = 12.62 vs the 12.73 frame median; the 0.11 ms difference is bookkeeping, and medians are not additive. 8,696 tracked + 300 detection frames = 8,996, against 9,000 = 5 min x 30 FPS. 1.66 W / 30 = 55.3 mJ ('about 55'). Power above idle: 2.46 - 0.79 = 1.67 vs printed +1.66 (rounding), and 4.47 - 0.79 = 3.68. Battery drops implied by mean power are 1.31 % (replay, printed 25->23 %) and 2.73 % (live, printed 23->20 %), both within integer-reading tolerance. Camera-to-overlay 124 - 94 = 30 ms. fp16 vs fp32 mean is 2.93 mm ('within 2.9 mm', rounding). The discrepancy: the live run reports 10,409 frames in 342 s at '30.0 FPS (10th pct. 29.6)' (tab:supp-device-runs; 5_experiments.tex:14). 10,409 / 342 = 30.44 FPS, while 342 s x 30 = 10,260 frames (149 fewer). Conversely, 10,409 frames at 30 FPS last 347.0 s. The frame count and the duration disagree by 1.4 %, beyond rounding. A likely explanation is that part of the 10 s warm-up was counted, but the paper does not say so. Minor, and it does not affect the real-time conclusion.
Recomputed sums, differences, frame counts against duration x 30 FPS, energy per frame, power above idle, and battery-percentage drops against mean power for the S23's 3,900 mAh x 3.88 V = 15.1 Wh battery, allowing ±1 % for integer battery readings.
The fit is limited by 2D keypoint quality (EgoHumans: +0.4/+0.7 mm with own 2D, +17.1/+6.1 mm with GT 2D); the fit costs 0.91 ms on the S23 and 0.14 ms on TRT (0.14-0.16 ms per size); on 3DPW it gains 0.6-2.1 mm (1 crop) and 0.7-2.5 mm (2 crops)
Oracle gains 52.9-52.5 = 0.4, 34.6-33.9 = 0.7, 52.9-35.8 = 17.1, 34.6-28.5 = 6.1; fit cost 6.40-5.49 = 0.91 ms (S23), 1.12-0.98 = 0.14 ms (TRT); TRT costs per size 0.15/0.14/0.16/0.14; 3DPW gains 2.1/1.6/1.4/0.6 (1 crop) and 2.5/2.0/1.7/0.7 (2 crops). Note the oracle uses only two sequences and 'a faster stand-in' protocol (14 joints).
Recomputed oracle deltas and per-size fit costs and 3DPW gains from the tables
Released README latencies and box factor agree with the paper (nano fit2 S23 8.72 ms, tiny 5.81/9.22, small fit2 10.37; detector-to-GT box factor 1/0.86).
All accuracy cells and all RTX latencies agree (zero differences). Four S23 NPU fit latencies differ by 0.01-0.03 ms: nano fit2 8.73 (README) vs 8.72 (paper); tiny fit1 5.84 vs 5.81; tiny fit2 9.20 vs 9.22; small fit2 10.36 vs 10.37. These are probably separate timing runs. They are negligible and do not change any conclusion, but the two documents are not from the same measurement. The box factor differs in value and source: README.md:71 and inference.py:21 use 1/0.866 for RF-DETR boxes ('measured on 3DPW'), while the paper (supp_body.tex:191-197) uses 1/0.86 for YOLO11n-pose boxes (median ratio 0.860 EMDB-1, 0.852 3DPW). The detector-box numbers in the paper therefore come from a different detector and factor than the released demo.
Parsed both README tables and tab_family.tex and compared every accuracy and latency cell (EMDB-1, 3DPW, RTX 4070, S23 NPU for fit 0/1/2, all five models) at printed precision. Compared the box factor text.
All 54 bibliography entries exist and match their cited metadata (including 2025-26 arXiv IDs for MHR, Anny, SOMA, SAM 3D Body, Fast SAM 3D Body).
All 54 references were found. The arXiv IDs for MHR (2511.15586), Anny (2511.03589), SOMA (2603.16858), SAM 3D Body (2602.15989), Fast SAM 3D Body (2603.15603), AI Challenger and BlazePose GHUM Holistic resolve to the cited titles. The web resources exist: GEM-X repo, and the Seeing Machines technical paper, whose 5.5 / 15.8 ms Jetson Thor latencies match sec/2_related.tex:37. Low Crossref title similarity for [7], [28], [30] and [40] only reflects short registered titles ('1 € filter', 'SMPL', 'VNect', 'PhysCap'). Spot checks match: the six SAM 3D Body Table 2 rows quoted in supp_as_published (SAM 3D Body, PromptHMR, HMR2.0b, WHAM, TRAM, GENMO), the CameraHMR fine-tuned, SMPLer-X-H and RICH notes, the RICH reproduction gaps (2.6, 9.9 mm), and Fast SAM 3D Body's 'up to 10.9x, training-free'. Metadata problems: [24] cites the ICCV 2025 GENMO paper under its later repository name 'GEM' (published title 'GENMO: A GENeralist Model for Human MOtion'), and the paper calls it GEM in the text but GENMO in the supplementary table. [51] is a self-citation listed as ICEC 2026; only an arXiv preprint was found. [29] has a truncated title. All are minor; none affects a technical claim. Details in work/ref_issues.json. Bibliography lookups were run with tools/check_refs.py (results in work/refs_checked.json).
Ran tools/check_refs.py (Crossref and arXiv lookups) and compared each matched title with the cited one. Looked up web-only and unmatched entries. Spot-checked load-bearing quoted numbers against SAM 3D Body (arXiv 2602.15989) Table 2 and the Fast SAM 3D Body (arXiv 2603.15603) abstract.
InstantHMR-M takes 5.49 ms on the S23 NPU, '12x and 23x faster than NLF-S and NLF-L'; with the fit 6.40 ms is '10.6x' and 10.22 ms '6.7x' faster than NLF-S; it is 'faster than every method we evaluate'
67.97/5.49 = 12.38 (claimed 12x), 125/5.49 = 22.77 (23x), 67.97/6.40 = 10.62 (10.6x), 67.97/10.22 = 6.65 (6.7x); all S23 grey factors match to the nearest integer. Caveats: (a) 'faster than every method we evaluate' holds for 7 of 8 timing columns but not ORT fp32 on the RTX 4070, where NLF-S takes 3.71 ms against 4.42 ms for M (Table 1); (b) the SAM 3D Body grey factor is printed 425x while 416/0.98 = 424.5x, and the TRT grey factors mix one-decimal (1.4x, 1.6x) and integer (2x, 6x for 5.62) rounding. All cosmetic except (a), which qualifies the abstract wording.
Recomputed every headline ratio and every grey speed-factor cell from the LaTeX tables; checked per latency column whether any competitor is faster than InstantHMR-M
With one crop, InstantHMR-M + fit is 'within 0.2 mm of NLF-S's PA-MPJPE on EMDB-1 (45.2 against 45.0 mm), with a lower MPJPE and PVE, and equal to it on 3DPW (39.4 mm)'; with two crops it 'beats NLF-S on all three EMDB-1 metrics'; abstract: 'matches NLF-S on EMDB and 3DPW'
Every stated inequality holds: EMDB-1 PA 45.2 vs 45.0 (+0.2), MPJPE 70.9 vs 74.6 (-3.7), PVE 84.3 vs 87.9 (-3.6); 3DPW PA 39.4 vs 39.4; 2 crops beat NLF-S on EMDB-1 PA/MPJPE/PVE by 0.6/4.8/4.7 mm. Qualifications: on 3DPW NLF-S remains better on MPJPE (62.2 vs 63.2) and PVE (74.6 vs 75.1), and on RICH by 6.1-6.9 mm; the 3DPW PA 'match' does not need the fit, since the 0.9 crop alone gives 39.2 (Table 4); all differences are single-run and sub-millimetre with no uncertainty reported.
Compared the fit rows with NLF-S on all nine metrics of Table 2 and cross-checked against the crop-only row of Table 4
Crop and fit are separate, roughly additive effects: on EMDB-1 'the crop alone gains 2.2 mm, the fit alone 1.3 mm, and both 3.6 mm'; on top of the 0.9 crop the fit gains 1.4 (EMDB-1) and 0.6 (RICH) and is 0.2 worse on 3DPW; the second crop gains 0.8 on EMDB-1 and loses 0.4 on RICH
All eight deltas reproduce exactly (2.2, 1.3, 3.6, 1.4, 0.6, -0.2, 0.8, -0.4 mm); additivity 2.2+1.3 = 3.5 vs 3.6. Interpretive point: on 3DPW the 0.9 crop alone (39.2) beats crop+fit (39.4), so the abstract's '3DPW match with NLF-S' comes from the crop rescale, not the kinematic fit; on RICH the 2-crop variant is worse than the 1-crop variant.
Recomputed every difference from Table 4
The fit is one Levenberg-Marquardt step over 68 unknowns from 30 keypoints with an exact Jacobian; the Jacobi-scaled system is inverted by 10 Newton-Schulz iterations from X0 = I/||H~||_inf; scaling residuals/J by 1/16 and the prior by 1/256 'leaves the minimiser unchanged' and keeps fp16 in range
Code constants match the paper (prior 30 / 0.01, mu 1e-3, 10 NS iterations, 1 LM step, 68 unknowns, 30 keypoints, J 60x68). Analytic Jacobian matches finite differences (relative error 4.9e-7). The 1/16, 1/256 scaling leaves the exact step unchanged (relative difference 0) and brings max |J^T J| from 2.6e4-1.1e5 (overflowing fp16 at sigma floor) to 1e2-4e2; the fp16 module stays finite (step within 3% median of fp64). The released fp16 graph matches the fp64 re-implementation to <= 0.0062 rad. Caveat: 10 NS iterations do NOT converge to H^-1: the Jacobi-scaled H has condition number ~700 (synthetic) and the NS(10) step differs from the exact LM step by 5.7% median (max 8.5%) on the 12 real crops and by 8% median (max 40%) on synthetic problems. The practical effect on real crops is small: <= 0.6 mm in root-relative 3D keypoints and identical 2D reprojection error (~0.9 px vs 2-6 px before the fit). The paper should describe X_10 as an approximate (implicitly regularised) inverse rather than imply an exact LM step. Second script: work/verify/07b_ns_real.py (real crops through the released fp16 graph).
Ran the released kinematic_fit.py with Meta's MHR rig (assets v1.0.1): constants; analytic vs finite-difference Jacobian; NS(10) vs exact solve on 400 synthetic problems; scaled vs unscaled step; fp16 vs fp64 module. Then ran the released instanthmr-medium-fit1.onnx graph on 12 real person crops (two COCO val2017 images with jittered boxes), exposed its SimCC probabilities, rebuilt the fit in fp64 and compared NS(10) with an exact solve
Training only on commercially usable images (M-C: Harmony4D and COCO) 'costs 23 mm on EMDB-1: the training images matter more than any architectural change we tried'
The gap itself is right: 72.2 - 48.8 = 23.4 mm on EMDB-1 (also 10.7 on 3DPW and 23.8 on RICH). But the released configurations show that M-C differs from M in more than the images: window_mode 'standard' (no framing mix) instead of 'random' with window0_p 0.75, and training/README.md says M-C 'was stopped at epoch 532 of 600'. The paper's own design ablation gives 58.8 vs 48.8 mm (10.0 mm, about 43% of the gap) for 'standard crop only' vs the 75% mix with the same data. The causal attribution of the 23 mm to the training images is therefore confounded with augmentation and schedule, and the paper does not disclose these differences.
Computed the gap from Table 3; diffed the released run_config.json files of the medium and medium-commercial checkpoints (Hugging Face); compared with the paper's crop-framing ablation and the training README
Among phone methods M is '20-25 mm more accurate than SMPLer-X, MeshPose and Multi-HMR on EMDB-1, 10-15 mm on 3DPW and 20-28 mm on RICH'; SMPLer-X-S32 is '22 mm less accurate'; Fast SAM 3D Body and SAM 3D Body are '8-10 mm better'
EMDB-1 gaps 22.2/24.9/19.7 (claimed 20-25); 3DPW 10.4/9.7/14.8 (10-15); RICH 19.5/27.7 (20-28, MeshPose not reported); SMPLer-X-S32 EMDB gap 22.2 (22); Fast SAM 3D Body 10.2 and SAM 3D Body 8.5 mm better (8-10). All within rounding to the nearest mm.
Recomputed every gap from tab_accuracy.tex
Nano to medium: EMDB-1 PA-MPJPE 61.7 -> 48.8 mm while S23 NPU latency grows 4.60 -> 5.49 ms; S23 CPU latency 'triples (31.5 to 93.0 ms)', only nano real time on CPU; 'with two crops, [the fit] gains 5.8 mm (nano) to 4.4 mm (medium) on EMDB-1, 2.5 to 0.7 mm on 3DPW and 4.0 to 0.7 mm on RICH', smaller sizes gain most
93.0/31.5 = 2.95 ('triples'); only nano (31.5 ms) is <= 33.3 ms on the S23 CPU; 2-crop gains nano/medium 5.8/4.4 (EMDB-1), 2.5/0.7 (3DPW), 4.0/0.7 (RICH), monotone in size on all three. Detail not stated in the text: on RICH the second crop helps only nano; it is neutral for tiny (47.1 = 47.1) and worse than one crop for small (43.7 vs 43.5) and medium (41.0 vs 40.6), so the default '--fit 2' is not uniformly the better setting.
Recomputed all gains, ratios and monotonicity from Table 3
Released medium model reproduces Table 2 (48.8/74.9/89.1 EMDB-1, 40.0/64.0/76.8 3DPW); sizes 20.0/20.3/24.4/32.2 M for N/T/S/M; output MHR 204 rig params, 18,439 vertices, 6,890-vertex subset.
Benchmark numbers could not be rerun (no EMDB/3DPW/SMPL data), so the headline reproduction claim is unverified. The checkable parts: parameter counts nano 20,010,463 (20.0), small 24,441,625 (24.4), medium 32,221,019 (32.2) and medium-commercial 32.22 M match the claims; tiny has 20,356,163 = 20.36 M, which rounds to 20.4, not the stated 20.3 (sec/3_method.tex:13, README.md:43; minor rounding slip, tolerance ±0.05 M). The released code runs end to end on CPU: outputs MHR params (204,), shape (45,), 70x2 keypoints, (18439,3) vertices, all finite; mean body-keypoint reprojection gap |proj(3D)-2D| 4.48/2.80 px without the fit vs 0.85/0.96 px (fit1) and 0.83/0.85 px (fit2), consistent with the fit's stated purpose. CPU latency on this 2-CPU runner 73-89 ms (base), 64-75 ms (fit1), 128-136 ms (fit2) end to end, not comparable to the paper's device numbers. The 6,890-vertex output is produced only in benchmark/evaluate.py via Meta's MHR->SMPL conversion (needs smplx and SMPL files), not by the released model itself. Exact parameter counts: work/verify/10b_param_exact.py.
Counted ONNX initializer elements of all released graphs; ran the released InstantHMR class (instanthmr/inference.py) on CPU (onnxruntime) with the base, fit1 and fit2 medium graphs on two COCO val2017 images with manual boxes; checked shapes, finiteness and 3D->2D reprojection. EMDB/3DPW benchmark not rerun: datasets and SMPL model files require registration and are not available here.
Evaluation uses ground-truth boxes with the crop scale of Table 4 (0.9, and 0.7 for the second crop) and 3DPW boxes 'enlarged by 20%'.
With the fit graphs, InstantHMR.predict always enlarges the box it is given by DETECTOR_TO_GT_BOX = 1/0.866 before applying the graph's crop scale (inference.py:176), including the ground-truth boxes passed by evaluate.py. On a 350 px GT box, fit1 crops at an effective 1.0393x the GT box instead of 0.9, and fit2 at 1.0393 and 0.8083 instead of 0.9 and 0.7 (= 0.9/0.866 and 0.7/0.866, exact). So running the released benchmark on a fit graph (possible only by passing the .onnx path; evaluate.py has no --fit option and resolve_model defaults to fit=0) does not evaluate the ground-truth-box protocol that produced the fit rows of Tables 2 and 4. The paper's own validation sweep (supp_body.tex:277: scale 1 / 0.9 / 0.8 -> 41.6 / 40.1 / 41.3 mm on 3DPW val) shows this framing difference matters by about 1.5 mm. evaluate.py also has no crop-scale option, so the network-alone 0.9-crop rows (e.g. 46.6 / 39.2 mm, supp_body.tex:192) cannot be produced from the release. The network-alone path is consistent: scale 1.0, no enlargement. 3DPW boxes: evaluate.py:95 pads 0.2·w and 0.2·h on each side, i.e. x1.40 in width and height, while the paper says 'enlarged by 20 %' (x1.20 under the usual reading); the docstring says 'extent + 20%'. This is ambiguous wording rather than an error, but it should be stated. Other inconsistencies: the code factor is 1/0.866 for RF-DETR boxes (inference.py:19-21), while the paper uses 1/0.86 for YOLO11n-pose boxes (supp_body.tex:191,197). The fallback focal of 1.05 x diagonal gives a 45.1 deg horizontal FOV on 16:9, not the 'about 50 degrees' of the comment at inference.py:16 (code comment only).
Wrapped InstantHMR._crop to log the box and scale it receives, then called predict() with a ground-truth box exactly as evaluate.py:125 does, using the released base, fit1 and fit2 medium graphs. Parsed evaluate.py for model, fit and crop-scale options and for the 3DPW padding. Computed the field of view of the fallback focal.
H
~
∥
Replace “no added latency” with the measured ~13 ms (0.4 frame) lag of the 1 Euro filter, and qualify “faster than every method we evaluate” for ORT fp32 GPU.
Unify the detector and box factor between paper (YOLO11n-pose, 1/0.86) and release (RF-DETR, 1/0.866). Fix the 20.3 M parameter count for tiny, the 3DPW padding wording, and the GEM/GENMO citation.
Discuss the SAM 3D Body pseudo-label ceiling, e.g. by evaluating InstantHMR against SAM 3D Body's own predictions to separate teacher error from student error.