The folding mechanism and its efficiency gains hold and the released code is consistent with the method. However, the SOTA tables compare against baselines that the authors' own code calls 'not like-for-like', and several SeizeIT2 fusion headlines (best unimodal model, all six variants, the 13-point margin, the intro's 78.9 %) are contradicted by the repository's own run tables.
Soundness
2/4
Presentation
2/4
Contribution
3/4
Confidence
4/5
✓ 8 confirmed✕ 11 discrepancy
Summary
The paper extends the authors' PhysioWave wavelet-Transformer into a family of pre-trained encoders for EEG (30M parameters), ECG (30M) and sEMG (12M). Its central device is dynamic scale folding: the J+1 learnable-wavelet subbands are recombined into one signal per channel, using per-sample softmax weights and small learned filters, before patch tokenization. This cuts the token count from (J+1)CS to CS. Route-specific front ends (one per channel-count / sampling-rate pair) and name-based channel embeddings let one Transformer per modality be pre-trained across heterogeneous montages: 15.4M EEG windows over 19–128 channels.
Empirically, the paper claims three things. First, folding is 4.0–7.2× faster and uses 6.8–12.7× less memory than scale expansion with no accuracy loss. Second, the encoders beat published baselines on three EEG, three ECG and two sEMG benchmarks. Third, a reliability-aware latent fusion module (RALF) combines frozen EEG/ECG/EMG encoders on SeizeIT2. There it raises seizure sensitivity at 11 false alarms/h from 61.4 % to 74.4 % and window AUPRC from 0.321 to 0.399, and it beats weighted-logit and concatenation fusion. Sec. 6 adds interpretability analyses of the channel embeddings, the learned wavelets and the fold weights across sleep stages.
Strengths
Simple, effective fix for multiscale token blow-up
Sec. 3.3, eq. (fold)/(alpha); Sec. 5.6 l.1352–1366; Fig. fold_efficiency
Scale folding (eq. fold, eq. alpha) is cheap and well-motivated. It is initialised to equal the subband mean exactly; check 18 instantiated it and found max |diff| = 0. It removes the (J+1) factor before the Transformer. The released profiling JSON reproduces the latency ratios (3.96–7.25×), memory ratios (6.80–12.71×), the E128 31.98 GB vs 2.52 GB, and a fold share of 1.53–2.61 % (check 06).
Tables are internally consistent and baseline cells are transcribed correctly
Tables 2–5; Secs. 5.2–5.6
Every derived number in Secs. 5.2–5.6 recomputes from the tables: 15 EEG deltas, 12 ECG, 9 sEMG, 16 ablation Δs and 31 ablation text values (checks 07, 08, 10, 11). The quoted baseline cells match their sources exactly: 36/36 against EEGPT Table 4, 48/48 against PhysioWave Table 1, and 10/10 against PhysioWave Table 2.
Unusually transparent, runnable release
Code release (README, docs/, configs/); Table 1
The repository ships pre-training manifests, resolved configs, per-figure metadata JSON with checkpoint paths, and a candid docs/fusion.md that reports negative results. All 20 rows of Table 1 match the dataset manifests (check 12). Instantiated parameter counts match the paper: 25.4M PhysioWave-T E19, 40.4M LUNA-L, 25.3M EEGPT and 5.8M LaBraM (check 13). 26/26 method constants match the code (check 18). The repo's test suite passes on CPU: 238 passed, 0 failed (check 19). Much of the critique below was only possible because of this openness.
Broad multi-modal evaluation with three adaptation modes
Tables 2–4
Eight downstream datasets across three modalities are each reported for linear probe, full fine-tuning and training from scratch. This exposes when pre-training actually helps, e.g. +8.7 F1 on CPSC but only +0.9 on Chapman, and a Sleep-EDFx kappa of 0.7365 fine-tuned vs 0.7363 from scratch. Few biosignal foundation-model papers report this so honestly.
Weaknesses
SOTA comparisons are not like-for-like, contrary to the stated protocol
major · Sec. 5.2 l.948–955; Table 2; Sec. 5.3 l.1039–1040; Table 3; Sec. 5.4; Table 4; Abstract
Sec. 5.2 says PhysioWave-T follows 'the exact evaluation protocol of EEGPT' and 'the same subject-disjoint cross-validation folds'. The released code contradicts this. scripts/collect_eegpt_bench.py calls the EEGPT rows 'NOT like-for-like with ours': preprocessing differs, and EEGPT used a frozen probe averaged over folds. EEG/kaggle_ern_finetune.py tests on 4 of the 16 labelled subjects, 'not EEGPT's 10 Kaggle test subjects'. The P300/Sleep converters state 'What is NOT reproduced is their evaluation protocol' (check 09). The same pattern holds for ECG. The paper claims 'the exact data splits ... of PhysioWave', but PhysioWave uses subject-level 6:2:2 splits while the prep script uses PTB-XL strat_fold 1–8/9/10 and record-level 70/20/10 splits (check 10). The EPN-612 number is labelled 'indicative, not like-for-like' in docs/emg_downstream.md (check 11). Many winning margins are small: P300 +2.0 BAC, ERN AUROC +0.11, EPN-612 +0.30, GRABMyo +1.25. They are three-seed means without SD, so the 'leads eight of nine', 'highest macro-F1' and 'new state-of-the-art sEMG' claims cannot be read as controlled comparisons. Fix: rerun the strongest baselines (EEGPT, LaBraM, PhysioWave-L) on the authors' own splits, or state the protocol differences and drop the SOTA framing.
Fusion headline compares to the authors' own EEG model, not the best unimodal model
major · Abstract l.148, l.151–153; Intro l.230–232; Sec. 5.5 l.1178–1193; Fig. fusion_results (b)
The abstract says RALF 'boosts window-level AUPRC from 0.321 to 0.399 over the best unimodal model'. In the authors' own docs/fusion.md, 0.321 is fine-tuned PhysioWave-T. Several EEG-only encoders score higher: LUNA-L fine-tuned 0.365, LUNA huge 0.358, LaBraM 0.345 (check 02). Against the best of these (0.365), the gain is +0.034, not +0.078. Likewise, 'exceeding any EEG-only encoder by at least 13 points' (l.1189–1190) holds only against PhysioWave-T itself. The dataset paper's SVM reaches 71.1 % at 11 FA/h on the same test patients, and the paper uses its operating point as the reference. LUNA huge reaches 63.4 % in the repo. Neither number is reported. RALF exceeds them by only +3.3 and +11.0 points (check 03). The claim that PhysioWave-T 'surpasses LUNA-L' (abstract) rests on 61.4 vs 60.9 % s@11: under one seizure of 181, from single runs. LUNA-L is better on AUPRC (0.365 vs 0.321) and AUROC (0.732 vs 0.723). Fix: report all EEG-only baselines, including the SVM and LUNA huge, in Fig. fusion_results, and restate the gains relative to the best one.
Questions for the authors
Can you rerun EEGPT and LaBraM (or at least EEGPT) on your own KaggleERN/P300/Sleep-EDFx splits, and PhysioWave-L on your ECG splits? Do the 'eight of nine' and 'highest macro-F1' claims survive like-for-like comparison?
Which RALF configuration and which EEG-only configuration does validation AUPRC select on SeizeIT2, and what are their test s@11 and AUPRC? Why were the original configurations reported instead?
How does RALF compare with the dataset paper's SVM (71.1 % at 11 FA/h) and with LUNA huge (63.4 %) on the same patients, and why were these omitted from Fig. fusion_results?
What are the seed standard deviations for Table 5's fold-vs-expansion row (+0.3) and for the EPN-612 / GRABMyo margins over PhysioWave-L?
Do the fold weights of the self-supervised pre-trained EEG model (no stage-label fine-tuning) show the same stage dependence as in Fig. fold_by_stage?
Which optimiser settings (β₂ 0.98 vs 0.95; weight decay 0.01 vs 0.05) produced the released checkpoints and the reported numbers?
Verification
We ran 19 scripted checks against the LaTeX source, the released repository (run tables in docs/fusion.md, profiling JSON, figure metadata, manifests and configs) and the baseline source papers. 9 were confirmed and 10 found discrepancies; none was inconclusive. Confirmed: the table arithmetic and every derived number in Secs. 5.2–5.6, the transcription of all 94 quoted baseline cells, the corpus sizes, the parameter counts by instantiation, the method constants in the code, the sleep-fold statistics, and the repo's test suite (238 passed). The discrepancies fall in two groups. Major ones sit in the SeizeIT2 fusion headlines (best-unimodal baseline, omitted stronger baselines, the 'all six variants' scope, test-based configuration choice, the intro's 78.9 %) and in the stated evaluation protocols, which the authors' own code calls not like-for-like. Smaller ones concern the efficiency details, optimiser settings, the wavelet and topology wording, and the label-free sleep claim. No reported accuracy could be retrained: no GPU, datasets or checkpoints were available.
8Confirmed
11Discrepancy
✕DiscrepancyIntroduction l.244-246 (main.tex); Abstract l.151-152; Sec. 5.5 l.1186-1190
[2] chen2026physiowave: Chen et al., PhysioWave: A multi-scale wavelet-transformer for physiological signal representation, NeurIPS 2026 (arXiv 2506.10351)
The work exists, but it is cited for something it does not support. Sec. 5.2 l.1039-1040 says the ECG experiments follow 'the exact data splits and evaluation protocol of PhysioWave'. PhysioWave (arXiv 2506.10351 §3.1) says 'Each benchmark is split by subject into 6:2:2 train/validation/test partitions'. The released prep script ECG/ecg_downstream_prep.py instead uses PTB-XL strat_fold 1-8/9/10 and a record-level 70/20/10 split with seed 42 for CPSC 2018 and Chapman (see check 10). The bib year is also wrong: the bib says 2026, but the paper itself (l.60) and the tables (NeurIPS'25) give NeurIPS 2025.
[28] doner2026luna: Döner et al., LUNA: efficient and topology-agnostic foundation model for EEG signal analysis, NeurIPS 2026
The work exists, but the year is wrong. LUNA appeared at NeurIPS 2025 (proceedings.neurips.cc 2025; arXiv 2510.22257), not 2026.
[9] wang2024eegpt: Wang et al., EEGPT, NeurIPS 2024
The work exists, and all 36 baseline cells copied from its Table 4 match (check 09). However, the paper says the comparison uses 'the same subject-disjoint cross-validation folds' (l.954-955), and the repo's own scripts contradict that. scripts/collect_eegpt_bench.py and EEG/kaggle_ern_finetune.py call the comparison 'NOT like-for-like'. KaggleERN is tested on 4 of the 16 labelled subjects, not on EEGPT's protocol. The citation therefore does not support the 'same folds' statement.
[T3-MaeFE] Zhang et al., MaeFE, IEEE TIM 2023; [T3-OpenECG] Wan et al., OpenECG, arXiv 2503.00711 (2025); [T3-MERL] Liu et al., MERL, ICML 2024
All three works exist and are Table 3 baselines with copied numbers (MERL, MaeFE, OpenECG-SimCLR/BYOL/MAE at main.tex l.1005-1013). None of them is \cite'd anywhere in the text. MaeFE and OpenECG have entries in refs.bib that are never cited, so they will not appear in the compiled bibliography. MERL has no bib entry at all.
[57] turgut2024towards: Turgut et al., Towards generalisable time series understanding across domains, arXiv:2410.07299
Minor. arXiv 2410.07299 now carries the title 'OTIS: Learning High-Quality Time Series Features With Tiny Encoders'; it is the same work, renamed. The citation is valid, but the title is out of date.
Suggestions
Rerun at least the strongest baseline per modality (EEGPT, PhysioWave-L, LUNA-L) on your own splits with the same seeds. Otherwise label the quoted rows as 'reported, different protocol' and drop the SOTA wording.
Correct the Introduction's 78.9 % to 74.4 %. Say explicitly that weighted-logit fusion attains the higher s@11, and that RALF's advantage is in AUPRC on EEG+ECG-containing subsets and at s@2.
Add the SeizeIT2 SVM (71.1 %) and all EEG-only foundation models from docs/fusion.md (LUNA huge, LUNA-L AUPRC 0.365) to Fig. fusion_results. Report fusion gains relative to the best of them.
Report the validation-selected configuration for RALF and EEG-only alongside the designed configuration, plus the min–max over the six variants for s@11.
Add seed SDs to Tables 2–5 and a paired test for the fold vs expansion comparison that underlies 'without accuracy loss'.
Repeat the sleep-stage fold analysis on the self-supervised checkpoint, or reword Sec. 6.3 and the Discussion to describe task-supervised adaptation.
Synchronise Sec. 5.1 with the released configs (β₂, weight decay, epochs) and eq. (fold) with the implementation (filtered-band mean).
Report downstream encoder sizes (about 25.4M for EEG) instead of the multi-route pre-training total. Fix the FLOP range, 'Transformer latency' and 'three seeds' in Sec. 5.6.
Cite MERL, MaeFE and OpenECG. Explain why ECG-Chat is omitted. Correct the PhysioWave and LUNA years and the OTiS title.
Ethics and integrity
No prompt-injection or reviewer-directed text was found in the paper, LaTeX source or code (case-insensitive greps of main.tex, source/ and code/). We found no evidence of fabricated results: all checked numbers trace to released artifacts. The problems are selective reporting and overstated framing, which the authors' own repository documents openly. All datasets are public research corpora, and the paper raises no specific consent or dual-use concerns.
Scope of this review
No GPU, pre-training corpora, downstream datasets or released checkpoints were available in the review environment. No accuracy, sensitivity or AUPRC number could therefore be regenerated by training or inference. Checks rely on the paper's LaTeX source, the released code (instantiated on CPU and run through its own test suite) and the run logs, tables and figure metadata the authors committed to the repository. Three end-to-end SeizeIT2 fusion tests were too slow for 2 CPUs and were not run. The GRABMyo baseline reruns could not be examined because no code, configs or logs for them are released. Reference checking: the automated Crossref/arXiv pass returned no lookup results, so the 8 load-bearing references were checked by hand (PhysioWave, EEGPT, LUNA, SeizeIT2 dataset paper, MERL, MaeFE, OpenECG, OTiS). The remaining 53 of 61 bibliography entries were not verified.
Table 5 isolates the fold vs expansion, uniform weights, synthesis filters, pre-training, channel encoding (removed vs shuffled), readout, label efficiency and missing electrodes. All Δ values recompute (check 07).
Representation analyses with proper nulls
Sec. 6.1, Sec. 6.3
The channel-topology analysis uses a 2,000-draw permutation null and an untrained-model control. The sleep-fold analysis uses per-subject paired Wilcoxon tests. The released statistics reproduce: ρ = −0.1919 / −0.2496, p = 1/2001, and Wilcoxon p = 2/8192 and 392/8192, which are exact attainable values (checks 14, 16).
RALF robustness and superiority claims are over-generalised; the intro misattributes 78.9 %
major · Abstract l.153–155; Intro l.244–248; Sec. 5.5 l.1186–1197; Fig. fusion_results (d) and caption l.1161–1163
The introduction (l.244–246) credits RALF with 78.9 % sensitivity. That is the weighted-logit result; RALF reaches 74.4 % (abstract, Sec. 5.5, repo; check 01). On the headline operating point, the simpler weighted-logit rule therefore beats RALF, which the abstract does not say. The abstract says RALF beats weighted-logit and concat 'across all six training variants'. From the figure data, all six variants beat both baselines on only 2 of 7 modality subsets (EEG+ECG and complete). The reported RALF is below weighted-logit on EEG (0.252 vs 0.268), ECG (0.313 vs 0.335), EEG+EMG and ECG+EMG (check 04). This contradicts the intro's 'most clearly on ECG-containing combinations'. One 'learning-rate and schedule' variant (e15siena) actually uses a different, Siena-continued EEG encoder. Fix: restrict the claim to the EEG+ECG-containing subsets as Sec. 5.5 does, report the weighted-logit advantage at s@11, and describe the variants accurately.
Reported SeizeIT2 configurations were not selected by validation
major · Sec. 5.5 l.1192–1194; Fig. fusion_results caption
Sec. 5.5 calls window-level AUPRC 'the validation selection metric'. Yet the reported RALF run ranks 3rd of 6 variants on validation AUPRC (0.380). Validation would select e15 (val 0.401), whose test results are AUPRC 0.394 and s@11 69.3 %, not 74.4 %. The reported run is the one with the highest test s@11 of the six (check 05). Similarly, for EEG-only, validation prefers C1+Siena (0.397 vs 0.385; s@11 59.8 %), but the paper reports the original C1 at 61.4 %. The repo explains that the original was kept as the designed configuration, but the paper does not disclose this. With single runs per variant and a val–test Spearman of 0.54 across variants, the headline 74.4 % should be accompanied by the validation-selected result and the spread across variants.
'Without accuracy loss' and many SOTA margins lack variance estimates
major · Tables 2–5; Sec. 5.6; Abstract
Tables 2–5 report three-seed means with no SD, and SeizeIT2 is a single run per configuration. The key efficiency–accuracy claim ('without accuracy loss') rests on a +0.3-point mean Δ for fold vs expansion (Table 5). Several 'wins' are within plausible seed noise: ERN AUROC +0.11 over EEGPT, P300 kappa within 0.003, EPN-612 +0.30. The decomposition 'uniform −1.6 = 0.7 synthesis + 0.9 α' takes the α share as a residual rather than a separate measurement (check 07). Fix: report SDs or CIs, and paired tests for the claimed advantages.
Sleep-stage interpretability overstated: the fold was trained with stage labels
major · Sec. 6.3 l.1517–1538; Discussion l.1553–1556; Fig. fold_by_stage
The Discussion (l.1555) says the fold weights 'track sleep stages without stage labels', and Sec. 6.3 says the network 'is never told the stage'. The analysed checkpoint, however, is sleep_edf_ft_lr1e-4/best.pth, a full fine-tune selected by kappa. The figure metadata states the front end was 'trained from scratch on Sleep-EDF during fine-tuning ..., so these weights were learned for sleep staging'. ScaleFold sits inside that front end (check 15). The effects are also tiny. a3 varies by 0.010 (Pz-Oz) and 0.003 (Fpz-Cz) around a near-uniform 0.25. 'Rises steadily from wake to N3' fails on Fpz-Cz, where N1 and REM are below W. Within-stage ρ ranges from −0.44 to 0.23, so the pooled ρ mostly reflects between-stage differences (check 14). Fix: analyse the self-supervised pre-trained fold (or a frozen-probe run), or reword the claim as task-driven adaptation.
Optimiser settings in the paper do not match the released runs
minor · Sec. 5.1 'Optimization' l.916–922; eq. (fold) l.512; eq. (fusionloss) l.741
The paper states AdamW β=(0.9, 0.98), weight decay 0.01 and 60/60/40 epochs. The code uses β=(0.9, 0.95). All three resolved pre-training configs use weight decay 0.05. The sEMG config is set to 60 epochs, and the logs show 60 EEG, 57 ECG and 39 sEMG epochs completed (checks 12, 18). There are also small formula differences. In eq. (fold), b̄ is the mean of the unfiltered bands, whereas the code uses the mean of the gs-filtered bands. The reliability term is a mean, not a sum. The 'symmetric KL' carries a factor ½. Fix: align the text with the released configs.
Efficiency numbers partly mis-described
minor · Abstract l.144–146; Sec. 5.6 l.1355; Fig. fold_efficiency caption l.1370
The claimed FLOP range of 4.3–5.5× does not match the JSON. Total-FLOP ratios are 4.31/4.07/5.30/5.52, so E32 falls below 4.3. Transformer-only ratios are 4.57–7.00. The abstract's 'Transformer latency' is in fact whole-encoder latency. The caption says 'averaged over three seeds', but the benchmark is a median over 20 iterations of one run and has no seed loop (check 06). None of this changes the conclusion that folding is much cheaper.
Wavelet and topology analyses misstate their own numbers
minor · Sec. 6.2 l.1490–1505; Sec. 6.1 l.1461
Wavelets: the sEMG cutoffs 'rising ... to 356–418 Hz' omit route A24, which falls from 124.8 to 112.0 Hz. 'At level three the weights concentrate on a single basis within each modality's bank' fails for both ECG routes: the L1_250 selector stays uniform (0.18–0.22, entropy 1.00) and L12_500 peaks at 0.617. 'Every route keeps a mixture at level one' fails for E19, which puts 0.935 on sym4 (check 17). Topology: 'more than twelve standard deviations' is −11.99 SD for the 10-5 family, and the correlations are weak (|ρ| ≤ 0.25) (check 16).
'30M-parameter backbone' overstates the downstream model size
minor · Abstract; Intro l.258; Tables 2–4 Params columns; Sec. 5.5
The 30.3M EEG total includes all route front ends and pre-training-only heads (1.45M). The shared Transformer is 25.2M, and a single-route downstream encoder is 25.4M, the figure the paper itself uses on SeizeIT2 (check 13). Tables 2–4 should report the downstream encoder size so that parameter comparisons with baselines are consistent.
Uncited baselines and bibliography errors
minor · Table 3 l.1005–1013; refs.bib
MERL, MaeFE and OpenECG appear as Table 3 baselines with copied numbers but are never \cite'd. MERL has no bib entry at all. PhysioWave's ECG-Chat row (CPSC F1 80.1) is dropped without explanation; with it, the CPSC best F1 would not be the 74.5 shown. PhysioWave and LUNA are dated 2026 in refs.bib, though both appeared at NeurIPS 2025. The OTiS entry uses the paper's earlier title.
ECG (Table 3, Sec. 5.3): best macro-F1 on PTB-XL Super (70.9) and Chapman (56.7); +4.2 over PhysioWave-L and +6.2 over MaeFE; pre-training gains CPSC +8.7/+1.7, PTB +4.0/+2.6, Chapman +0.9/+0.9; the frozen encoder retains 95-96 % of AUROC and about 91/80/94 % of F1; baselines quoted from PhysioWave under its 'exact data splits'.
All 12 text numbers recompute exactly. The six best/second marks are correct. Retention: AUROC 94.8/95.0/96.3 % (text '95-96 %'; PTB rounds to 95); F1 91.1/80.3/94.2 %. All 48 baseline cells match PhysioWave Table 1 (0 mismatches). Caveats: (1) PhysioWave Table 1 also lists ECG-Chat (13B: PTB 55.9/94.1, CPSC 80.1/95.7), which is dropped here; with it, the CPSC F1 best is 80.1, not 74.5. (2) 'Following the exact data splits ... of PhysioWave' is not supported. PhysioWave says 'Each benchmark is split by subject into 6:2:2', whereas the released prep script uses PTB-XL strat_fold 1-8/9/10 and a record-level 70/20/10 (seed 42) split for CPSC and Chapman. The splits therefore differ, and the quoted baselines are not same-split comparisons. (3) PhysioWave does not specify a superdiagnostic multi-label PTB-XL task ('ECG rhythm classification'), so the 'PTB-XL Super' label on its numbers is unverified. (4) The 73.9 % five-class accuracy (+3.4) is in the text only, not in a table. No SDs are given.
Parsed Table 3 from LaTeX, recomputed every number in the text and the best/second marks, compared all 48 baseline cells with PhysioWave Table 1 (pdftotext), and compared the split statements with PhysioWave's text and the released prep script.
sEMG (Table 4, Sec. 5.4): highest accuracy and F1 on EPN-612 (94.80, +0.30 over PhysioWave-L) and GRABMyo (89.78/89.74, +1.25/+1.37); +7.11 over MOMENT and +10.40 over OTiS; scratch/probe/fine-tune gaps 0.46, 2.37 and 4.45; EPN baselines quoted from PhysioWave; GRABMyo baselines rerun with three seeds.
All 9 text checks recompute exactly, all marks are correct, and 12M/37M = 0.32 and 385M/12M = 32 match 'about one third' and 'roughly one thirtieth'. All 10 EPN-612 baseline cells match PhysioWave Table 2. Caveats: (1) The margins are small and given without SDs (EPN +0.30 accuracy; GRABMyo +1.25). (2) docs/emg_downstream.md says the PhysioWave EPN-612 number uses 'max-abs normalisation, 1024-sample inputs and its own training recipe. The number is indicative, not like-for-like', which qualifies the paper's 'follows PhysioWave's user-dependent protocol'. (3) The GRABMyo baselines (MOMENT, OTiS, PhysioWave-S/B/L) are said to be 'rerun on this split with three seeds', but the repo contains no code, configs or logs for these reruns (the only MOMENT match is a comment in heads.py), so they cannot be checked.
Parsed Table 4 and recomputed all text deltas, marks and parameter ratios. Compared the EPN-612 baseline cells with PhysioWave Table 2. Searched the repo for GRABMyo baseline-rerun code and for notes on the EPN-612 comparison.
Pre-training corpora total 15.4M EEG windows ('over 15M windows spanning 19 to 128 channels'), 7.6M ECG and 5.1M sEMG (Table 1); corpora sampled with P(d) ∝ n_d^0.5; EEG/ECG trained 60 epochs, sEMG 40.
Sums: EEG 15,421,495 (15.4M), ECG 7,564,963 (7.6M), sEMG 5,106,203 (5.1M); all match. EEG channel counts span 19-128. All 20 Table 1 rows match the manifests exactly (route and window count; 0 mismatches). The manifest target weights equal n_d^0.5/b_route normalised, i.e. window share ∝ n_d^0.5 (max error ~1e-16), consistent with the paper's rule. Minor: the logged pre-training ran 60 EEG epochs, but only 57 ECG epochs (paper: 60) and 39 sEMG epochs (paper: 40; config says 60).
Parsed Table 1, summed windows per modality, compared every row (route and count) with the released dataset_manifest.json, recomputed the sampling weights from n_d and the route batch sizes, and read the epoch counts from config_resolved.yaml and metrics_epoch.jsonl.
Parameter counts: EEG 30M, ECG 30M, sEMG 12M; on SeizeIT2 PhysioWave-T has 25.4M vs LUNA-L 40.4M ('surpasses LUNA-L ... with fewer parameters'); EEGPT 25M, LaBraM 5.8M.
Instantiated counts: PhysioWave-T E19 encoder 25,412,674 (25.4M); EEGPT 25,287,168 (25.3M); LaBraM 5,819,936 (5.8M); LUNA-L 40,449,480 (40.4M); LUNA huge 303,406,520. These match ENC_PARAMS_M and the paper. LUNA-L/PhysioWave-T = 1.59. Manifest totals: EEG 30,300,691, ECG 30,079,821, sEMG 12,052,622, matching 30M/30M/12M. Caveat: the '30M' in Tables 2-4 and the 'one shared 30M-parameter backbone' (l.258) count all route front ends plus pre-training-only heads (EEG pretraining_only 1.45M; E128 front end alone 2.49M). The shared Transformer is 25.2M, and a single-route downstream EEG encoder is about 25.4M, so the 30M label overstates downstream model size by about 15 %. Also, the fewer-parameter claim holds, but LUNA huge (303M) beats PhysioWave-T on s@11 (see check 03).
Instantiated the released architectures on CPU with torch (the repo's own counting snippet from docs/fusion.md) and counted parameters. Also read the per-component parameter breakdowns in the pre-training manifests.
Sleep-fold analysis: 37,902 windows from 14 subjects; a3 (<6.25 Hz) 'rises steadily from wake to N3 and returns toward its wake value in REM'; the wake-to-N3 increase holds in 13/13 subjects on Pz-Oz (Wilcoxon p=2.4e-4) and 10/13 on Fpz-Cz (p=0.048); rho = 0.21 / -0.22.
All numbers match the metadata: 37,902 windows, 14 subjects, a3 band 0-6.25 Hz, p=2/8192=2.44e-4 with 13/13 positive (the exact all-positive value), p=392/8192=0.0479 with 10/13 positive (attainable with W-=17), rho 0.2119 / -0.2229. Caveats: (1) 'Rises steadily from wake to N3' holds on Pz-Oz (W 0.2473 < N1 0.2499 < N2 0.2537 < N3 0.2574) but not on Fpz-Cz, where N1 (0.24298) and REM (0.24285) are below W (0.24310). (2) Effects are tiny: a3 varies by 0.010 (Pz-Oz) and 0.003 (Fpz-Cz) around a near-uniform 0.25, and the Fpz-Cz N3-W CI (0.00313 ± 0.00301) barely excludes 0. (3) Within-stage rho ranges from -0.44 to 0.23 on Pz-Oz, so the pooled rho mostly reflects between-stage differences.
Read the released figure metadata. Enumerated the exact Wilcoxon signed-rank null for n=13 (8192 sign patterns) to check the p-values are attainable and consistent with the sign counts. Checked stage monotonicity of the subject-mean and paired a3 weights per derivation.
The folding network 'is never told the stage' (l.1522), and the folding weights 'track sleep stages without stage labels' (Discussion l.1555).
The analysed weights come from '$PW_FAST_ROOT/runs/eeg_downstream/sleep_edf_ft_lr1e-4/best.pth' (full fine-tune, epoch 6, selected by kappa). The metadata itself states the frontend was 'trained from scratch on Sleep-EDF during fine-tuning ..., so these weights were learned for sleep staging'. In model.py, WaveletFrontend.forward = self.fold(self.decomp(x)), so the ScaleFold is part of that freshly initialised, stage-supervised frontend. 'Never told the stage' is true only in the narrow sense that stage is not an input at inference. The Discussion's 'track sleep stages without stage labels' is contradicted: the fold parameters were optimised with stage-label cross-entropy, so their stage dependence is not label-free evidence of physiological tracking.
Read the analysed checkpoint's provenance from the figure metadata. Traced in the code that ScaleFold sits inside WaveletFrontend and that the Sleep-EDF downstream model builds a fresh frontend trained during full fine-tuning.
Channel embeddings encode scalp geometry: Spearman rho=-0.19 (10-5, 130 electrodes) and -0.25 (EGI, 128), 'more than twelve standard deviations from the permutation-null mean (p<0.001 over 2,000 draws)'; untrained rho=0.01; kNN 56/44 deg vs 84-88 deg after shuffling.
Minor. All quoted values match: rho -0.1919 / -0.2496; n 130 / 128; one-sided permutation p = 0.0005 = 1/2001 (the minimum attainable; < 0.001); untrained rho 0.0077 (10-5) and -0.0005 (EGI), i.e. 0.01 / 0.00; kNN 55.7 / 43.8 deg; shuffled-null means 84.4 / 88.1 deg. However, z = -11.99 SD for 10-5 (EGI: -14.90), so 'more than twelve standard deviations' is false for the 10-5 family by a hair. Note also that the absolute correlations are weak (|rho| ≤ 0.25).
Read the released statistics, recomputed z = (rho - null mean)/null SD, and compared all quoted values after rounding.
The sEMG low-pass -3 dB cutoffs rise from 125 Hz at initialization to 356-418 Hz. At level one every route keeps a mixture of bases, and at level three the weights concentrate on a single basis within each modality's bank.
(a) The sEMG level-1 low-pass cutoffs are W16_2000 124.8->355.9 Hz, G64_2000 124.8->418.3 Hz, and A24_2000 124.8->112.0 Hz. The A24 route, the third of the three sEMG routes, falls slightly instead of rising to 356-418 Hz, so the stated range omits one route. (b) 'Every route keeps a mixture' at level one fails for EEG E19_256, which already puts weight 0.935 on sym4 (normalised entropy 0.17). (c) The level-3 'single basis' claim fails for 3 of 9 routes. The maximum level-3 weight is 0.634 for E32_512, 0.617 for ECG L12_500, and 0.217 for ECG L1_250. The L1_250 weights stay 0.18-0.22 at all three levels (entropy 1.00), so that ECG selector is effectively uniform. Both ECG routes therefore violate 'within each modality's bank'. The other six routes do concentrate, with level-3 maxima from 0.852 to 1.000. (d) The level-1 high-pass cutoff on EEG E19 falls from 115.3 to 63.0 Hz, which is consistent with γ (30-80 Hz). The ECG L12 cutoffs change little (lo 36.3->57.5, hi 213.7->198.9 Hz). The cutoffs alone cannot confirm the QRS and 100-200 Hz statements, because the json holds no response-peak data.
The script reads docs/runs/fig_wavelet/figure_metadata/fig_wavelet.json, the data behind the figure. Panel c plots levels['1'].cutoff_lo_hz_of_mean_response, per scripts/visualize_wavelet_frontend.py l.519-520. For each route the script lists that cutoff, plus the selector weights at levels 1-3 as the maximum weight and the normalised entropy.
The released implementation matches the method as described. The listed constants are γ 0.1, delta-initialised g_s, a 16-unit MLP on three statistics, KL weight 1e-3, 70% mask with s=0.6e+0.4z, 0.5/0.5 loss, P(d)∝n^0.5, the RALF ½ residual, 0.2 unimodal CE, and corruption probability 0.5. The paper also states optimiser settings: AdamW β=(0.9,0.98), weight decay 0.01, and 60/60/40 epochs.
The code matches all 26 method constants. These cover the ScaleFold items: γ=0.1, a 3-tap depthwise delta g_s, a 16-unit GELU MLP on 12 inputs (3 stats × 4 scales), a zero output layer and θ, and an initial fold exactly equal to the mean (max |diff| 0). They also cover mask 0.7 with importance_ratio 0.6, spec/raw 0.5/0.5, fold_kl 0.001, and temperature 0.5 for all three modalities. On the fusion side they cover q=4, n_f=8, residual_weight 0.5, uni_weight 0.2, corruption prob 0.5, and reliability and consistency weights of 1.0. The stated optimiser settings differ from the code in 5 places. (1) AdamW betas are (0.9, 0.95) in code, against the paper's (0.9, 0.98). (2-4) Weight decay is 0.05 in all three resolved pre-training configs, against the paper's 0.01. (5) The sEMG run is configured for 60 epochs, against the paper's 40; the logs show 39 completed, see check 12. There are also minor formula differences. eq:fold's reference term b̄ is the mean of the unfiltered b_s, but the code uses the mean of the g_s-filtered bands; the two are identical only at initialisation. The reliability MSE is a mean over modalities rather than the written sum. The 'symmetric KL' is 0.5×(KL(a‖b)+KL(b‖a)).
The script instantiates the released WaveletFrontend/ScaleFold on CPU and checks the initial γ, the g_s kernel, the MLP shape, the zero initialisation, and that the initial fold equals the subband mean. It then parses docs/runs/{eeg,ecg,emg}_c1_moe/config_resolved.yaml, the configs of the actual pre-training runs. It also parses the AdamW call in physiowave/eeg_c1/train.py, which the ECG and EMG trainers inherit, along with configs/fusion/c1_ralf.yaml and physiowave/fusion/model.py.
Code release: the released code is the implementation used for the paper, and its pre-training and fusion entry points run (README / l.150 code link).
238 passed, 3 deselected, 0 failed in 723 s. The 3 deselected tests are the end-to-end fusion training ones: test_fusion_trains_evaluates_and_tabulates, test_seizeit2_official_split_train_and_event_evaluation and test_seizeit2_eeg_only_c1_eegpt_labram. A first full run did not finish them within its 40-minute limit on 2 CPUs. That run's other failures were all ModuleNotFoundError for h5py/wfdb, which went away once those libraries were installed. Together with check 13, where the released architectures instantiate with the stated parameter counts, and check 18, where 26/26 method constants match, the code is runnable and consistent with the method. This does not reproduce any reported metric: it shows the code runs, not the results.
The script runs the repo's own pytest suites on CPU with the small synthetic settings they ship with: the EEG/ECG/EMG C1 pre-training entry-point tests (they build smoke corpora through the preprocessing CLIs and train the trainers end to end), the objective, the C1 fusion tests, the wavelet modules, and the EEGPT-benchmark data builders. Extra libraries used: PyWavelets, h5py, wfdb and pytest, all installed under /tmp. No released checkpoints or datasets were available, and there is no GPU, so none of the reported numbers could be re-trained.
RALF raises event sensitivity at 11 FA/h from 61.4 % to 78.9 % (Introduction) vs 74.4 % (Abstract, Sec. 5.5)
Introduction credits RALF with 78.9 %; the repo run table gives ralf_frozen_szo s@11 = 74.4 % and weighted_logit_frozen_szo s@11 = 78.9 %. Abstract and Sec. 5.5 (74.4 % RALF, 78.9 % weighted-logit) agree with the repo; the Introduction misattributes the weighted-logit number to RALF. Note that the competing weighted-logit rule beats RALF on this headline operating point.
Grepped all 74.4/78.9 statements in main.tex and parsed the authors run table in docs/fusion.md (RALF sweep table)
RALF raises window-level AUPRC from 0.321 to 0.399 over the best unimodal (EEG) model
0.321 is fine-tuned PhysioWave-T (C1) alone, not the best unimodal model. The authors own table lists LUNA large fine-tuned 0.365, LUNA huge 0.358, LaBraM 0.345, LUNA huge frozen 0.347 and even frozen C1 0.322. Against the best EEG-only encoder (0.365) the RALF gain is +0.034, not +0.078.
Parsed the EEG-alone SeizeIT2 results table in docs/fusion.md and took the maximum window-level test AUPRC
Fusion at 11 FA/h (74.4 % RALF, 78.9 % WL) exceeds any EEG-only encoder by at least 13 points; PhysioWave-T EEG-only (61.4 %) surpasses LUNA-L (60.9 %)
The dataset paper reports SVM 71.1 % sensitivity at 11.0 FA/h on the same held-out patients (sub-097..125), and the authors own repo table has LUNA huge fine-tuned at 63.4 %. RALF exceeds them by only +3.3 and +11.0 points (WL by +7.8 and +15.5); the 13-point margin holds only against PhysioWave-T itself (+13.0). Neither 71.1 % nor LUNA huge appears in main.tex although the SVM operating point is used as reference. The 61.4 vs 60.9 % lead over LUNA-L is 0.5 points (under one seizure of 181) from single runs; LUNA-L has higher window AUPRC (0.365 vs 0.321) and AUROC (0.732 vs 0.723).
Parsed EEG-only rows of docs/fusion.md and Table 2 of the SeizeIT2 dataset paper (arXiv 2502.01224); computed margins of each fusion rule over every EEG-only detector; grepped main.tex for the omitted baselines
RALF outperforms weighted-logit and concatenation fusion in AUPRC across all six training variants (Abstract; Intro adds most clearly on ECG-containing combinations); Sec. 5.5 restricts to EEG+ECG-containing sets (0.384-0.414)
Complete set: all six RALF variants 0.384-0.414 > WL 0.372 > concat 0.347 (exact match between the SVG read-out and the docs table, so the narrow Sec. 5.5 claim is confirmed). But all six variants beat both baselines on only 2/7 subsets (EEG+ECG, complete). The original RALF is below weighted-logit on EEG (0.252 vs 0.268), ECG (0.313 vs 0.335), EEG+EMG (0.265 vs 0.284) and ECG+EMG (0.337 vs 0.348), contradicting the Introduction phrase most clearly on ECG-containing combinations and the unqualified abstract wording. One of the six variants (e15siena) uses a different, Siena-continued EEG encoder, not a learning-rate/schedule setting as the caption says.
Parsed the sweep table of docs/fusion.md and recovered panel (d) of the released paper figure fig_main.svg by calibrating the matplotlib y-axis ticks and reading the RALF, weighted-logit and concat lines and the six-variant min-max band for all 7 modality subsets
Window-level AUPRC is the validation selection metric; the reported RALF configuration reaches 0.399 test AUPRC and 74.4 % s@11
The reported run ralf_frozen_szo ranks 3rd of 6 on validation AUPRC (0.380); validation selects e15 (val 0.401), whose test numbers are AUPRC 0.394 and s@11 69.3 % (vs 74.4 % reported). The reported run has the highest s@11 of the six variants. Val-test Spearman across variants is 0.54. Likewise for EEG-only, validation picks C1+Siena (0.397 vs 0.385; s@11 59.8 %) but the paper reports the original C1 (61.4 %). The repo justifies keeping the original as the designed configuration, but the paper does not disclose this; selection within a run is by validation, selection across configurations is not.
Parsed validation and test AUPRC and s@11 of all six RALF variants (and the EEG-only C1 vs C1+Siena runs) from docs/fusion.md; identified the validation-best configuration
Folding cuts Transformer latency 4.0-7.2x, peak memory 6.8-12.7x, FLOPs 4.3-5.5x over four EEG routes; E128 ~32 GB vs 2.5 GB; fold is 1.5-2.6 % of the forward pass; averaged over three seeds
Confirmed: latency ratio 3.96-7.25 (claimed 4.0-7.2), memory 6.80-12.71 (6.8-12.7), E128 31.98 GB vs 2.52 GB, fold share 1.53-2.61 % (1.5-2.6). Discrepancies (minor): total FLOP ratios are 4.31/4.07/5.30/5.52, so E32_512 (4.07x) falls below the claimed lower bound 4.3x (Transformer-only FLOP ratios are 4.57-7.00, so neither definition gives 4.3-5.5). The latency is the whole encoder forward (decomposition+fold+patcher+Transformer), not Transformer latency as the abstract says. The benchmark takes a median over 20 iterations of one run with no seed loop and the JSON has no seed field, contrary to averaged over three seeds in the caption.
Recomputed all ratios from the released profiling output docs/runs/fold_efficiency/fold_efficiency.json and inspected scripts/benchmark_scale_fold.py
Table 5 Deltas and all derived ablation numbers (fold +0.3 over expansion, uniform -1.6 = 0.7 synthesis + 0.9 alpha, w/o pre-training -3.7 with 4.7/6.3 on ERN, channel 2.6/2.8 vs 0.9/1.1, label efficiency 0.8/1.2 and 2.6/3.8, missing electrodes 60.4 vs 58.4)
All 16 Deltas match within rounding (e.g. uniform 1.625 -> 1.6, w/o channel enc 1.85 -> 1.8); all 31 text and cross-table numbers match exactly (tolerance 0.05). Caveat: Table 5 reports three-seed means with no SD, and the central no accuracy loss claim rests on a +0.3-point mean difference (fold vs expansion); the 0.9-point alpha share is the residual 1.6 - 0.7, not a separately measured ablation. The repo contains no per-seed ablation results or scale-expansion training switch to check further.
Parsed all 16 ablation rows, recomputed each Delta as the mean four-metric change vs the full model, recomputed 18 derived numbers in the text, and cross-checked the full/scratch/probe rows against Table 2
Fine-tuned PhysioWave-T leads 8 of 9 EEG metrics vs BENDR/BIOT/LaBraM/EEGPT; kappa 0.686->0.737, W-F1 76.5->80.9, ERN +3.3 BAC/+0.018 kappa, P300 +2.0/+2.0, kappa within 0.003, and adaptation-mode deltas
Fine-tuned best on 8/9 (only P300 kappa 0.2975 < EEGPT 0.2999). All text numbers match within rounding (e.g. ERN BAC +3.34, kappa +0.0177, P300 BAC +2.04, AUROC +2.02, ERN probe 3.35 below scratch). Marks are correct. Context: two of the eight wins are tiny (ERN AUROC +0.11 pts over EEGPT; Sleep kappa fine-tune 0.7365 vs scratch 0.7363), and our values are 3-seed means with no SD while baselines are quoted.
Parsed Table 2 from main.tex, counted metrics where the fine-tuned row beats every baseline, recomputed all 15 deltas in the text and checked the bold/underline marks
Table 2 EEG baselines are cited directly from EEGPT, and PhysioWave-T is evaluated 'following the exact evaluation protocol of EEGPT' and 'under the same subject-disjoint cross-validation folds' (Sec. 5.2, l.948-955).
Numbers: all 36 baseline cells match EEGPT Table 4 exactly (0 mismatches), so the citation itself is confirmed. Protocol: the claim of identical protocol and folds is contradicted by the authors' own code. scripts/collect_eegpt_bench.py says the EEGPT rows are 'NOT like-for-like with ours': preprocessing differs, and EEGPT uses a frozen linear probe averaged over folds and scored on its validation subjects, whereas 'Ours is one fold, with a test set nothing selected on'. EEG/kaggle_ern_finetune.py says the KaggleERN test set is 4 of the 16 labelled subjects, 'not EEGPT's 10 Kaggle test subjects, so their Table 4 row is a reference, not a comparison on the same data'. The P300 and Sleep converters say 'What is NOT reproduced is their evaluation protocol'; P300 also includes subject 1, which EEGPT's script omits. Table 2 caption says 'three-seed means' but gives no SDs, while EEGPT reports mean±std. Minor: EEGPT's parameter count is internally ambiguous (abstract says '10-million-parameter'; Tables 2/3 say 25M; Sec. 3.5 says the 'large' 101M model was used for all downstream tasks). Table 2's 25M follows EEGPT's own table.
Parsed the 4 baseline rows of Table 2 and EEGPT Table 4 from the NeurIPS proceedings PDF and compared all 36 cells. Extracted the protocol sentences from EEGPT and the protocol notes in the released repo's converter and collector docstrings.