A carefully measured, statistically candid systems paper whose LVBench numbers are internally consistent and whose coverage analysis reproduces exactly from public data. However, nothing can be rerun (no code, prompts or predictions), the causal 'decoupling improves accuracy' claim rests on one non-significant dev-set run, and the Video-GAIA +8.5 is judged by the same model that is being evaluated.
Soundness
3/4
Presentation
3/4
Contribution
3/4
Confidence
3/5
✓ 13 confirmed✕ 3 discrepancy
Summary
VideoNexus is a training-free agent harness for long-video question answering. A planner LLM never sees raw media. It calls perception sub-agents (Transcribe, a bounded global Overview scan, a planner-parameterised local Inspect with chosen interval and fps, and crops). Each sub-agent reads native audio and video in its own context and returns a compact, timestamped Finding (status plus evidence items on the absolute timeline), optionally with a small evidence card of at most 6 frames. The paper argues that this keeps the planner's context roughly independent of how much media is perceived. Coupled agents, which return frames, and per-frame-captioning delegated agents such as VideoSeek both keep the size of the observation tied to sampling density.
With Gemini 3.8 Flash in both roles, the paper reports 88.6% (1,372/1,549) on full LVBench at $0.140 per question. That is +3.6 over same-backbone static 1 fps ingestion (85.0%, p=5e-7), +1.1 over Gemini's built-in agentic mode (87.5%, p=0.10, not significant) at 44% of its cost, and +7.2 over a re-run of VideoSeek (81.4%). Supporting analyses cover: a paired dev-200 ablation of raw-clip versus text-Finding returns (−32% planner input, 86.5→89.0, p=0.23); per-call measurements of report size against media read (Overview slope 0.00, Inspect slope 0.18); an analytical coverage study of sparse uniform scans on the LVBench evidence windows; and transfer to Gemini 3.0 Flash and Kimi K3, including +8.5 over the official Video-GAIA ReAct harness.
Strengths
Statistically candid reporting of paired comparisons
Sec. 4.2, Sec. 4.4, Sec. 4.6
Every full-set comparison gives discordant counts and an exact McNemar p-value. Non-significant results are labelled as such, including against the strongest baseline (Agentic 57/40, p=0.10), in the coupling ablation (8/3, p=0.23) and in the density ablation (8/2, p=0.11). We recomputed all of them: 5.09e-7, 0.104, 5.02e-16, 0.227 and 0.109 match the printed values (checks 02, 08, 11). This is better practice than most agent papers, which report single accuracy deltas.
Main results table is arithmetically coherent
Table 1; Sec. 4.2; Fig. 6b and fig6_density.tex
Every row of Table 1 (lower block) has a unique integer solution across the six LVBench categories (560/526/196/147/55/65) that rounds to the printed Overall: Blind 627, Static 1,316, Agentic 1,355, VideoSeek 1,261, VideoNexus 1,372. The won/lost nets in Sec. 4.2 reproduce the row differences exactly (check 01). The Fig. 6b slice counts close additively to the Table 1 totals, including the no-transcript and unwindowed remainders (check 12).
Density/coverage analysis is independently reproducible
Sec. 4.6, Table 4, Fig. 6a
Table 4 can be rebuilt from the public LVBench annotation file. We recomputed all 18 coverage cells within 0.04 pp, along with the spacings, the 250 zero-length windows, the 17 s median window and the 30% of windows of at most 5 s (check 05). A Monte Carlo test confirms the closed-form coverage probability clip(d/Δ− (check 06). The finding that VideoSeek-scale uniform scans cover the evidence window for only about half of the questions is therefore solid. It gives a concrete, data-grounded reason why sparse global scans miss evidence.
Weaknesses
Nothing can be rerun: no code, prompts, traces or per-question predictions
major · Sec. 3.2–3.4; Sec. 4.1; Supp. A–B
The project-links field is empty. The planner 'skill', the tool prompts, the harness (a Claude Code session with an MCP bridge to Gemini) and the per-question outputs are not released. The backbones (Gemini 3.8 Flash, Kimi K3) are versioned commercial APIs. Our checks could therefore establish only the internal consistency of the reported numbers, plus the parts that depend on public data (coverage analysis). None of the accuracy or token counts could be regenerated. Per-call data would also be needed to verify the slope fits and r=0.01 in Fig. 5. Fix: release the harness, the verbatim prompts and skill, the trajectories, and per-question predictions for every arm. Paired results can then be re-tested, and the McNemar counts audited.
Causal claim for decoupling rests on one non-significant dev-set run
major · Abstract; Sec. 4.4, Table 3a; Supp. I
The abstract states that the paired ablation 'shows lower planner input and higher accuracy'. The accuracy difference is +5 net questions on dev-200 (8 fixed / 3 regressed, p=0.23; we obtain 0.227, check 08). It falls within the stated run-to-run resolution of ±3 questions (Supp. I), and dev-200 was used for development. Moreover, the raw-clip arm without Transcribe has the lowest planner input of all arms (8.92M versus 12.33M for Text Finding), so the −32% reduction holds only within the transcript-enabled pair. Only the input reduction is supported; the accuracy benefit of decoupling is not established. Fix: hedge the abstract and the contribution list, and repeat the paired ablation over several runs or on held-out questions.
Headline margins over external systems are weak or confounded
major · Abstract; Sec. 1; Sec. 4.2, Table 1; Fig. 6b; Supp. C
The gain over the strongest baseline, Gemini Agentic, is +1.1 (57/40, p=0.10; confirmed in check 02), so it is not significant. The 44% cost figure compares against a closed server-side mode whose bill is dominated by 72.4k reasoning tokens per question, so it reflects provider behaviour as much as the design. Against VideoSeek (+7.2, at lower cost), the re-run has no audio or ASR, pays still-image rather than native-video media prices, and runs at a changed thinking level. In the no-speech slice the lead drops to +3.9 on 284 questions (check 12), and under image-tier repricing VideoSeek's cost can fall to 89% of VideoNexus's (check 04). Fix: report a VideoSeek arm given the same ASR transcript, and state the Agentic comparison as parity in accuracy with a cost advantage.
Questions for the authors
What are the accuracies and paired McNemar results of all arms on the 1,349 LVBench questions outside dev-200? Does the +3.6 over Static and the parity with Agentic hold there?
How many times was the coupling ablation (Table 3a) run? What is the run-to-run spread of both planner input and accuracy? Do the 8/3 discordant questions recur across runs?
Does the Video-GAIA +8.5 survive re-judging by a judge from a different model family, and a ReAct baseline given the same 40-step budget with the crop bug fixed?
How much of the +7.2 over VideoSeek remains when VideoSeek receives the same cached ASR transcript as VideoNexus?
Which population of calls underlies Table S2 (5,504) versus the 4,992 Inspect+crop tasks and the 3.7 calls/q of Fig. S2b? Are retries or failed calls counted differently?
Why does Overview read 1,019 frames per call when every LVBench video exceeds 1,024 s and the rule caps at 1,024 frames at ≤1 fps, while 1,024×66 tokens are billed?
Will the harness, verbatim planner skill and tool prompts, trajectories and per-question predictions be released?
Verification
We ran 16 scripted checks: 13 confirmed and 3 discrepancies, all minor. None were inconclusive. Because no code, logs or predictions are released, the checks test internal consistency and the parts tied to public data. Table 1 integer reconstruction, all McNemar p-values, cost ratios and repricing, the coupling, density and card ablation arithmetic, Table S2 ratios and the Fig. 6 slice reconciliation all agree with the paper. Table 4 coverage and the LVBench statistics reproduce exactly from the official annotation file, provided two unstated data conventions are applied. The VideoSeek numbers cited from its paper match. Discrepancies: Video-GAIA 163/271 printed as 60.2 instead of 60.1; perception call counts that disagree by about 3% across Table S2, Fig. S2 and the behaviour text; and a video token rate that is 60 rather than 66 per frame for non-16:9 video. None of these changes a main conclusion. The checks do not validate the accuracies themselves, which could not be regenerated.
The bib entry gives only a GitHub URL (https://github.com/jylins/videoseek) and no arXiv ID or DOI. The work exists as arXiv 2603.20185, with matching title and authors. This is a minor metadata problem, not a wrong work.
yang2026videoxagent (Online Video Agent Harness for Long Video Understanding, arXiv 2609.12818)
The reference exists and its abstract names the system VideoXAgent. The paper uses a 'VideoXAgent budget (60.8)' average-frame operating point (sec/4_experiments.tex:178, figures/fig6_density.tex). That number does not appear in the cited abstract and could not be checked against the full text. It is unverified, not shown to be wrong.
Suggestions
Release the harness, verbatim prompts and skill, full trajectories and per-question predictions for every arm, with API model versions and dates.
Rephrase the abstract: state that the dev-200 accuracy gain from decoupling is not significant, that the Agentic margin is parity, and that Video-GAIA is self-judged and directional.
Report held-out (non-dev-200) LVBench results, and repeat the coupling and density ablations over several runs with confidence intervals.
Add a VideoSeek arm with the same ASR transcript, and a cost comparison under matched media pricing, to isolate the interface effect from the audio and pricing effects.
Re-evaluate Video-GAIA with an independent judge family and matched step budgets, and report its cost.
Correct 60.2→60.1 in Tables 2 and 5, reconcile the perception call counts (Table S2, Fig. S2, behaviour text) and the 1,019 vs 1,024 Overview frame count, and note that tokens per frame depend on aspect ratio.
Document the LVBench conventions: the 15 dropped malformed windows and first-label categorisation.
Add a table that maps each experiment to its harness version, tool set and baseline configuration, and report wall-clock latency alongside API cost.
Add the arXiv identifier 2603.20185 to the VideoSeek reference.
Ethics and integrity
No integrity concerns. Every reconstructed count is integer-feasible and the numbers reconcile across tables; the discrepancies found look like ordinary rounding and bookkeeping slips. No instructions aimed at reviewers were found in the source. The benchmarks use public videos. Using the evaluated model (Kimi K3) as the sole judge is a methodological weakness, not an ethical one.
Scope of this review
No code, prompts, run logs or per-question predictions were available, and the commercial backbones (Gemini 3.8 Flash, Kimi K3) were not queried. We therefore could not rerun any accuracy, token or cost measurement, or verify the Fig. 5 per-call regressions. Checks cover internal arithmetic and statistics, recomputation from the public LVBench annotation file, the cited VideoSeek results, and bibliographic existence of all 58 references. The Video-GAIA data and the full text of VideoXAgent (source of the 60.8-frame budget) were not examined.
The central concept is measured directly, not asserted
Sec. 4.5, Fig. 5, Table S2
Fig. 5 and Table S2 relate returned-text size to perceived media across all logged perception calls of the full run. Overview returns 740 tokens for 141k media tokens (191×), while VideoSeek's overview returns about 28 tokens per frame read. Our recomputation of the ratios, per-frame rates, call totals (5,504 / 7,949) and the decile-implied slope of 0.18 agrees (check 10). This turns the 'bounded observation' idea into a falsifiable quantity.
Careful baseline reproduction and cost accounting
Supp. B, Supp. C, Fig. 3b
The VideoSeek re-run documents its provider-interface fixes (thought-signature replay), two bugs in the released code and the raised thinking level. Costs are given on a cold-start basis, with sensitivity analyses for within-question caching and image-tier pricing. All ratios recompute: 44% = 0.4397, 1.34×, 1.09×, output shares 52%/33% (check 03). The four-tier VideoSeek repricing and the 89% zero-image-cost figure are reproduced by a linear model that agrees with the Table S2 image-token totals (check 04).
Transparent about confounds and limitations
Limitations; Supp. E, G; Table 1 (Blind row); figure sources
The paper discloses: the audio/ASR asymmetry against VideoSeek, reported with speech/no-speech slices; the Video-GAIA development overlap and setting mismatches (Supp. G); the non-held-out dev-200 ablations; answer variability (7 of 55 duplicates changed); and a blind control (40.5%) that quantifies the text prior. Provenance comments in the figure sources carry exact counts, which made most of our checks possible.
Video-GAIA +8.5 is self-judged, on development questions, with misaligned settings
major · Abstract; Sec. 4.3, Table 2; Table 5; Supp. G
The single LLM judge is Kimi K3, the same model as the backbone under evaluation. The questions were used to develop the web and crop tools. The arms differ in step budget (40 vs 24), thinking handling and observation proxy; our run hit a crop-coordinate bug; and judge temperatures are mixed (Supp. G). No cost is reported. The counts are otherwise consistent (163/271 vs 140/271, 51/28, unique L1/L2 and domain splits; check 09). However, 163/271 = 60.15% should print as 60.1, not the 60.2 shown in Table 2 and Table 5 (discrepancy, minor). The unreported exact McNemar p for 51/28 is 0.013. Despite the authors' own caveats, the abstract presents +8.5 as a headline result. Fix: re-judge with an independent judge of a different model family (ideally with human spot-checks), match step budgets, and move the result out of the abstract or qualify it there.
LVBench headline includes the development subset
minor · Sec. 4.1; Sec. 4.2
dev-200 (13% of LVBench, covering all 103 videos) drove design decisions and is included in the full-set 88.6%. The effect is probably small, but because every video was seen during development, no number is truly held out. Fix: report accuracy and McNemar tests on the 1,349 non-dev questions for all arms.
Transfer table mixes harness versions and baseline configurations
minor · Sec. 4.7, Table 5
The Gemini 3.0 row uses an earlier harness without ASR against a medium-resolution static baseline. The Kimi K3 rows use LVBench-200 and Video-GAIA. The narrative that the 'margin shrinks as the baseline strengthens' therefore compares non-comparable settings. The Gemini 3.0 p<1e-4 is plausible (a net gain of 98–100 questions satisfies it for any discordant total up to about 635; check 11), but it cannot be checked without discordant counts.
Perception call counts disagree across Table S2, Fig. S2 and the behaviour text
The behaviour statistics count 4,992 Inspect and crop tasks. Table S2, described as all perception calls of the full run, has 4,376 + 448 = 4,824, which equals the Finding total in Fig. S2c. The Fig. S2b histogram implies 3.67 perception calls per question, against 5,504/1,549 = 3.55 from Table S2 and the 3.6 used in Sec. 4.2, a gap of about 170–180 calls (check 13, discrepancy). Similarly, Overview is said to read 1,019 frames, yet every LVBench video exceeds 1,024 s, so the stated rule implies 1,024. Fig. 4 bills 67,584 = 1,024×66 tokens for lvbench_10 (checks 07, 14). Fix: define the per-call population behind Fig. 5/Table S2, including retries and failed calls, and reconcile the counts.
The 66 tokens/frame constant is not constant
minor · Sec. 3.1 (Eq. 1); Supp. B, K; Supp. trajectories
Sec. 3.1 uses τv=66, and Supp. B/K divide IMAGE tokens by 66 to estimate 464 frames per question for Gemini Agentic. In the paper's own trajectories, lvbench_734 (1280×536, not 16:9) is billed 60 tokens/frame at low resolution and 250 at high, against 66/264 elsewhere (check 14, discrepancy). Ten of the 103 LVBench videos are not 16:9, so the Agentic frame estimate is approximate. The paper's own observation that 92% of the counts are multiples of 66 is consistent with this. The effect on conclusions is small, but the text should state that the rate depends on aspect ratio.
Unstated data conventions in the LVBench analyses
minor · Sec. 4.1; Sec. 4.6, Table 4; Table 1 category columns
Reproducing the 1,534 time-annotated questions requires dropping 2 windows with missing times and 13 whose end precedes their start. The category counts (560/526/196/…) and 'KIR' use the first-listed label of a multi-label annotation; counting any label gives 677/647/291/201/58/220 (checks 05, 07). Neither convention is stated. Both should be documented, since per-category claims depend on them.
Formalism is a token-count model, presented as an analysis
minor · Sec. 1 (contributions); Sec. 3.1
Eqs. (1)–(2) restate how observation tokens scale with interval length, fps and per-frame cost. The '≪' in Eq. (2) is a design intent, verified only empirically later. Listing an 'analysis of the coupling' as the first contribution oversells what is a useful descriptive framing. Delegated textual perception itself is prior art (VideoSeek, VideoXAgent), so the novelty is the bounded-report interface together with the empirical study.
Shifting configurations across ablations hinder interpretation
minor · Sec. 4.4–4.6; Table 3b; Supp. E, I
Ablations use different harness versions: v0 on Gemini 3.0, a 3-tool setup, and 4 tools with cards. The density-ablation control (90.0%) is the +card arm of Table 3b (consistent with Supp. E; check 11), not the 89.0% Text-Finding arm of Table 3a. The frugal-budget cost ($0.143, dev subset) is compared with the full-set average ($0.140). Most Supp. I component deltas fall within the stated ±3-question noise. A configuration matrix that maps each table to its harness version would help.
Small numerical and bibliographic slips
minor · Sec. 4.2; Table 3a; Supp. C; references (lin2026videoseek)
Sum lead printed as +3.6 while the cells 96.4−92.7 give 3.7 (the unrounded value 3.64 supports 3.6; check 01). +45% for the no-Transcribe cost increase is 45.7% (check 08). Agentic/Static is 1.855, at the 1.85/1.86 rounding edge (check 03). The VideoSeek overview bills 1,250 tokens per image part, not the stated 1.1k tier (check 04). The VideoSeek bib entry gives only a GitHub URL, without its arXiv ID 2603.20185.
191.1x; 0.726; 6.51; 28.08 / 63.19 / 4.44; 156.2 tok/frame for the VideoSeek overview; sums 5,504 and 7,949 exact; 16.75x and 1.669x; log(1.67)/log(16.8) = 0.182, consistent with beta=0.18 (tolerance: printed precision). 5,504/1,549 = 3.55 calls/q, which rounds to the 3.6 in Sec 4.2. The per-call slope fits and r=0.01 cannot be recomputed without per-call data (none released). See check 13 for a call-count inconsistency between Table S2 and Fig. S2/behaviour statistics.
Arithmetic recomputation; implied endpoint slope from decile ratios
Density ablation 90.0 -> 87.0 (8 lost, 2 gained, 172 both, p=0.11); card ablations 74.5/79.5/75.5 and 89.0 -> 90.0; Kimi K3 73.0 -> 79.5; Gemini 3.0 full set +6.4 with p<1e-4
172+8=180 (90.0%), 172+2=174 (87.0%); p=0.109 (claimed 0.11); every n=200 percentage is an integer count (149/159/151, 178/180, 146/159). The 90.0% density control equals the 180/200 +card arm of Table 3b, consistent with Supp. E. Gemini 3.0 full set: 74.0/80.4 correspond to a net gain of 98-100 questions; p<1e-4 then holds for any discordant total up to ~635, so the bound is plausible but not checkable without discordant counts.
Count reconstruction, exact McNemar p, integer feasibility on n=200; discordant-pair range compatible with the Gemini 3.0 p bound
Fig. 6b slices: VideoNexus leads VideoSeek in all six window x speech slices (+1.8 to +10.3); pooled speech +8.7 (1,077 q), no speech +3.9 (284 q), overall +7.3 (88.6 vs 81.3 on 1,534); 1,148 in slices; zero-length groups 69 (82.6 vs 85.5) and 144 (88.9 vs 77.1)
All six leads reproduce (10.3/7.0/6.4/1.8/8.0/8.9); slices sum to 1,148; the zero-length percentages have unique integer counts (57/59, 128/111) that close the pooled rows exactly (966/872, 242/231); overall 1,359/1,534 = 88.6 vs 1,247/1,534 = 81.3 (+7.3). Remainders are feasible: 173 no-transcript questions (151 vs 144 correct) and 15 unwindowed questions (13 vs 14 correct, consistent with 1,372 and 1,261 in Table 1).
Recomputed percentages and leads from the per-slice counts; additive reconciliation of slices, zero-length groups, pooled rows, the no-transcript remainder and the Table 1 totals
Behaviour statistics: Overview on 632 q (41%) at 83.5% vs 92.0% otherwise; 1,251 q overlapping (89.0%) vs 255 (86.3%); 441/4,992 Inspect and crop tasks (8.8%); 383/560 absent followed by Inspect; 42 = 29 + 13; 122 of 177 errors; perception call totals
Consistent: 632 x 83.5% -> 528 and 917 x 92.0% -> 844 add to exactly 1,372; 632/1,549 = 40.8%; 441/4,992 = 8.83%; 383/560 = 68.39%, matching the Fig. S2c bar; 1,549-1,372 = 177; slice-level Overview rates (figS3) give 629 of the 632. Inconsistent call counts: the text reports 4,992 Inspect and crop tasks, but Table S2 (described as all perception calls of the full run) has 4,376 + 448 = 4,824 Inspect and crop calls, which equals the Finding total in Fig. S2c (4,123+560+141 = 4,824). The Fig. S2b histogram implies a mean of 3.67 perception calls/q (>=5,688 calls; the figure prints 3.7), against 5,504/1,549 = 3.55 in Table S2 and the 3.6 used in Sec 4.2. The gap is 168-184 calls (~3%). Severity: minor, but the per-call population behind Fig. 5/Table S2 should be defined.
Integer reconstruction of percentages, summation against the 1,372 headline, and reconciliation of call counts across Table S2, Fig. S2b/c and the behaviour text
Low-resolution native video costs 66 tokens/frame (tau_v=66; basis of the 464-frame Gemini Agentic estimate) and audio ~25 tokens/s; Fig. 4 token totals 162,824 and 982
Fig. 4 sums are exact (159,576+3,248 = 162,824; 608+374 = 982); audio is exactly 25 tok/s (e.g. 91,638/3,665.5 s), and the Overview audio tokens reproduce the stated video lengths (35.6/92.2/32.9 min match the public annotations, as do all five headers: category, length, window). The video rate is not a constant 66, though: lvbench_734 (the only non-16:9 video among the cases, 1280x536) bills 60 tok/frame at low and 250 at high resolution, against 66/264 elsewhere. The paper presents 66 as the per-frame price and divides IMAGE tokens by 66 to estimate Gemini Agentic frames (464/q), so that estimate is approximate for non-16:9 videos (10 of the 103 LVBench videos are not 16:9 by the public metadata). Also, Fig. 4 labels the lvbench_10 Overview as 1,019 frames while billing 67,584 = 1,024 x 66 tokens. Severity: minor.
Parsed all 22 per-call token annotations in the five supplementary trajectories plus the Fig. 4 comment; computed tokens/frame and tokens/s; matched trajectory headers to the public LVBench annotations by question index
All six cited numbers match the source exactly; 68.4-60.1 = 8.3, 76.7-66.5 = 10.2, 68.4-55.1 = 13.3. Note: VideoSeek is arXiv 2603.20185 (CVPR 2026), but the bib entry gives only a GitHub URL.
Compared with the VideoSeek paper (arXiv 2603.20185 HTML, main LVBench table and tool-ablation table) and recomputed the differences
Bibliography: all cited references exist and match their citation contexts (spot-check of load-bearing refs)
No nonexistent or misattributed references. Unresolved by check_refs, then resolved by title search with title-match score 1.0: spatialreward 2602.07458, videoseal 2605.12571, longvu 2410.17434, omniagent 2606.19341, haven 2601.13719, thyme 2508.11630, plus videotempo3 2602.07801. Resolved by arXiv id lookup with matching title and authors: Symphony 2603.17307, EVA 2603.22918, VideoSeek 2603.20185. Load-bearing spot-checks: Video-GAIA 2608.14718 abstract contains '271', consistent with the paper's 271 questions (the L1 62 / L2 209 split is not in the abstract). VideoXAgent: the bib title 'Online Video Agent Harness for Long Video Understanding' (2609.12818) is the paper whose abstract names the system VideoXAgent. The 60.8-frame budget (4_experiments.tex:178, fig6_density.tex) is not stated in that abstract and is not verified. REPAIR 2607.01469 matches its use in 2_related.tex:24 (re-execution variability). Minor: lin2026videoseek bib gives only a GitHub URL, with no arXiv ID or DOI.
tools/check_refs.py on work/references.json (58 refs) -> work/refs_checked.json; arXiv title search for refs unresolved by check_refs (16_unresolved_refs.py); arXiv id_list lookup for the remaining three (Symphony, EVA, VideoSeek) and for load-bearing refs (16b_id_lookup.py). Scripts: work/verify/16_unresolved_refs.py, work/verify/16b_id_lookup.py.
Table 1 lower block: per-category accuracies (ER 560, EU 526, KIR 196, Rea 147, Sum 55, TG 65) are integer-realisable and consistent with Overall; VideoNexus 1,372/1,549 = 88.6%; won/lost nets match row differences
Each row has a unique integer solution: Blind 627, Static 1,316, Agentic 1,355, VideoSeek 1,261, VideoNexus 1,372 (88.57%), all rounding to the printed Overall (tolerance: 0.05 pp rounding). 1,372-56=1,316, 1,372-17=1,355, 1,372-111=1,261 match. Rea lead 2.72 (claimed 2.7), Sum lead 3.64 (claimed 3.6; the printed cells 96.4-92.7 would suggest 3.7), TG gap is one question (60 vs 59).
GRIM-style search of integer correct counts per category for every row; sum vs printed Overall; baseline counts implied by 1,372 minus (won-lost)
Exact McNemar: vs Static 90/34 p=5e-7; vs Gemini Agentic 57/40 p=0.10 (n.s.); vs VideoSeek 153/42 p=5e-16
Obtained p=5.09e-7, 0.104, 5.02e-16 (claimed 5e-7, 0.10, 5e-16; tolerance: printed precision). Won-lost differences also match Table 1 counts (check 01).
Exact two-sided binomial test on discordant pairs, exact rational arithmetic
44%: 0.4397; 1.34x: 1.342; 1.09x: 1.092; output 0.04648/0.09820(claimed0.0465/0.0982);shares52.2 columns exceed fresh tokens x 0.75/Mby0.0048 (ours) and 0.0015(VideoSeek),consistentwithwithin−questioncachedtokensat0.075/M. All arithmetic is internally consistent; the underlying token counts themselves cannot be checked (no logs released).
Recomputed every ratio and dollar amount from the stated prices and the unrounded per-question values in the figure source
Image-tier repricing of VideoSeek: 0.252/0.188 / 0.155/0.140; zero image charge $0.125 = 89% of ours
With t0=1,108 tok/part: zero-image 0.1253(claimed0.125;89.30.1553 (0.155), top tier 0.2504−0.2527for2.2k−2.24k(0.252).Image implied by the fit (0.0630/q)agreeswithTableS2:131.3Mimagetokens0.75/M = $0.0636/q. Minor inconsistency: VideoSeek overview bills 9,998/8 = 1,250 tokens per image part, not the stated 1.1k default tier (skim/focus are 1,111/1,108).
Linear repricing model fitted on the as-run vs cheapest-tier input dollars from the fig3 source; predicted other tiers; independent cross-check of the image dollar share from Table S2 call counts x perceived tokens
Table 4 coverage of a random-phase uniform scan over 1,534 time-annotated LVBench questions (>=1/>=2 frames, KIR>=1), spacings, 250 single-timestamp windows, median 17 s, 30% <=5 s
All 18 coverage cells reproduce within 0.04 pp (e.g. 92.3 frames: 52.0/29.3/33.5 obtained vs 52.0/29.3/33.5 claimed; <=1024: 80.7/70.9/57.3). Spacings 66.6/63.2/43.8/10.5/4.0/2.0 s match as question-weighted means; 250 zero-length windows, ceiling 83.7%, median 17.0 s, 30.1% <=5 s, 193 KIR. The 1,534 count is reproduced only after dropping 2 windows with None and 13 windows whose end precedes their start (annotation errors in the official file), and KIR means the first-listed label (LVBench is multi-label: 288 windowed questions carry KIR anywhere). Neither convention is stated in the paper.
Recomputed from the official public LVBench annotation file (THUDM/LVBench video_info.meta.jsonl) with the stated formula and n = min(N, L x 1 fps)
P(>=k frames of a random-phase uniform scan with spacing Delta inside a window of length d) = clip(d/Delta - k + 1, 0, 1)
Max deviation 2.25 SE across all interior cells (e.g. d/Delta=1.75, k=2: MC 0.7485 vs 0.7500; SE 0.0007); boundary cells exact. The formula ignores video-edge effects, which is harmless for windows inside the video.
Monte Carlo, seed 0, 400k phases per cell, 11 values of d/Delta x k=1..3
103 videos, 1,549 questions; first-listed-label category counts match exactly (any-label counts differ: 677/647/291/201/58/220, sum 2,094, so the paper uses first labels without saying so). Min duration 1,809.0 s; 11 videos < 2,048 s; question-weighted mean min(L,2048) = 2,034.7 (claimed 2,035). Side note: because every video is longer than 1,024 s, the stated Overview rule (<=1 fps, <=1,024 frames) implies exactly 1,024 frames per call, while Table S2 and Fig. 4 report 1,019 (for lvbench_10, 1,019 frames are labelled but 67,584 = 1,024 x 66 video tokens were billed). The 12 audio-less videos cannot be checked from annotations.
-31.8% (claimed -32%), 1.466x (1.47x), p=0.227 (0.23), cost +4.8% (+5%), no-Transcribe +45.7% (+45%; would round to 46%). Arithmetic is consistent. Interpretive note: the raw-clip no-Transcribe arm has the lowest planner input of all (8.92M, vs 12.33M for Text Finding), so the planner-input reduction holds only within the transcript-enabled pair; the accuracy gain (+5 net questions) is not significant.
Recomputed ratios, counts and exact McNemar p
Video-GAIA: 163/271 (60.2%) vs 140/271 (51.7%), +8.5, 51 won / 28 lost; L1 77.4 vs 79.0 (one question); L2 55.0 vs 43.5 (+11.5); domain columns consistent
163/271 = 60.15%, which rounds to 60.1, not the 60.2 printed in Table 2 and Table 5 (tolerance: 0.05 pp rounding). Everything else is consistent: 140/271 = 51.66 (51.7); +8.49 points (+8.5); 51-28 = 23 = 163-140; unique L1/L2 splits 49/91 (ReAct) and 48/115 (ours), a one-question L1 gap and an L2 lead of 11.5; a unique domain-size vector (Cul 58, Day 61, Eco 6, Geo 63, His 44, Tec 39) reproduces all 12 domain cells and both totals. The exact McNemar p for 51/28, not reported in the paper, is 0.013. Severity: minor (rounding typo; the +8.5 headline is correct).
Percentages from counts; integer search for L1/L2 splits and for domain sizes (Eco n=6) consistent with every printed cell and with both totals; exact McNemar for 51/28