Summary
The paper proposes two indices computed from the continuous wavelet transform (generalized Morse wavelets) of beat-to-beat Finometer recordings taken during an active standing test. Index summarises high-frequency (HF) power of the interbeat interval (IBI) and is meant as a cardiac vagal marker. Index combines low-frequency (LF) power of systolic blood pressure (SBP) with a rate of 'bursts' and is meant as a vasomotor-sympathetic marker. Their ratio is put forward as a measure of autonomic imbalance.
Strengths
Fully specified wavelet pipeline
Sec. 2.4–2.5; Table S1 (referenced)
Section 2.4 gives the package and version (ssqueezepy 0.6.5), the wavelet family and parameters (, for SBP and 10 for IBI), PCHIP resampling at 4 Hz, cone-of-influence masking and the band limits. The CWT is computed over the whole 14-min record, which avoids an artificial boundary at the postural change. These details were enough to reimplement the pipeline: our implementation matched ssqueezepy 0.6.5 to within 1% for HF band power (check 15), and our simulated ratios matched those implied by Tables 2–3 (check 09).
Weaknesses
J/I–θ association, the advantage over LF/HF, and the 'ratio form' are expected by construction
major · Sec. 3.5–3.7, 4.4; Figs 5–7; Abstract (Results, Conclusions); θ definition in Sec. 2.1
(Sáinz-Jiménez 2026) is the major-axis angle of the confidence ellipse of computed on the same segments. It is therefore a function of the relative beat-to-beat variability of IBI and SBP. is a ratio of SBP to IBI oscillation power from the same data. LF/HF uses IBI only and cannot share this information.
Questions for the authors
How does J/I relate to θ once the ratio of beat-to-beat SBP to IBI variance (or the ΔSBP/ΔIBI variance ratio that enters the θ ellipse) is partialled out? If the association largely disappears, the 'tracks baroreflex function' interpretation cannot stand.
Can you compare J/I and LF/HF against a BRS estimate that does not share the variance-ratio structure of θ (sequence method, transfer-function gain, or Valsalva-derived BRS), or against COMPASS-31 and symptom scores?
What is the Spearman correlation between the burst rate B and mean LF SBP power within each posture, and how do the Sec. 3.4–3.7 results change when J is replaced by √A_LF alone?
How was the J-supine row of Table 4 obtained, given that a Youden-maximising cut-off cannot give Youden = −0.03? What are the supine AUCs for J/I and LF/HF?
Where does the 40.3° orthostatic threshold come from, given that the cited θ paper reports 38°? How sensitive are Table 4 and Fig 7 to this choice?
Do the group differences in J and J/I persist after adjustment for sex and resting heart rate?
Verification
Only the PDF was available, with no data, code or supplement, so the reported numbers could not be regenerated from raw recordings. We ran 16 scripted checks: 11 confirmed and 5 discrepancies. Consistency checks all passed. These were the regression-derived quantities, the Spearman p-values, the Table 4 counts and likelihood ratios, the AUC CIs, the bootstrap CIs, the text-versus-table statements (30/30), the Table 1 and the illustrative-case arithmetic. These checks show that the paper's numbers are mutually coherent; they do not test the physiological interpretation. Simulations with a reimplemented CWT pipeline, cross-validated against ssqueezepy 0.6.5, gave the following results. (i) The main inferential pattern (– correlation, beating LF/HF, and the incremental CV of with opposite-sign coefficients) appears even when every subject has the same baroreflex gain (checks 01, 16). (ii) The burst term mostly tracks LF power level (check 04). (iii) contributes about 1.6% of (check 09). (iv) One Table 4 row has an impossible Youden value (check 03). A concern raised while reading, that the standing transition leaks into orthostatic LF SBP power, was supported (check 05). References: all 49 exist, with two citation-support issues.
References
49 references checked
- [38] Sáinz-Jiménez et al. (2026), Frontiers in Cardiovascular Medicine 13:1830347
Exists and defines theta. The paper uses ROC reference thresholds of 68.3 deg (supine) and 40.3 deg (orthostatic) as if taken from this work, but the cited article reports ROC cut-offs of 68.39 deg supine and 38 deg upright (against COMPASS-31, in a smaller cohort with subgroups n = 16/8/14). The 40.3 deg threshold has no stated source. This self-citation is also the only validation of theta as a BRS estimator.
- [22] Malik et al. (1996), Task Force HRV standards, Eur Heart J 17:354-381
Cited for '0.13% of beats were removed per recording, a proportion reported as recommended by the Task Force'. The Task Force document does not prescribe an acceptable proportion of removed beats. The sentence should say what exactly is recommended (e.g. reporting the proportion of edited beats) or drop the attribution.
Suggestions
Validate J/I against at least one BRS measure that is not a variance ratio of the same SBP/IBI segments (sequence or transfer-function BRS, Valsalva, or pharmacological), and against an external outcome such as COMPASS-31.
Add a negative-control analysis: show that the J/I–θ association exceeds what the shared SBP/IBI variability alone produces, e.g. by partial correlation or with surrogate data that preserve the variances but randomise SBP–IBI coupling.
Redefine bursts with a threshold relative to the local LF power level, then report B separately from √A_LF and show its incremental value.
Either weight A_HF and σ_HF to comparable scales or simplify I to √A_HF and describe it as such.
Report all supine AUCs (including J/I and LF/HF), correct or explain the J-supine Youden, state the AUC CI method, and give optimism-corrected (bootstrap or nested-CV) cut-off performance.
Justify the 68.3°/40.3° thresholds and report sensitivity to the cited 68.39°/38° cut-offs.
Adjust the group comparisons for sex and resting heart rate, and consider correcting across the family of indices tested.
Replace the single-patient window illustration with a pre-specified analysis comparing symptom-marked and control windows across patients.
Fix the garbled equations and the Fig 7 caption. Provide Table S1, a data/code availability statement (ideally releasing the index code) and a competing-interest statement.
Ethics and integrity
Ethics approval (NER-4340-22-24-1) and written informed consent are stated, and funding is disclosed. There is no competing-interest statement. The BRS reference method (θ) and its thresholds come from the authors' own earlier work, which is the only validation cited for θ. This is not an integrity problem, but it should be declared and complemented by independent measures. No prompt-injection or manipulative text was found in the paper. There are no signs of fabricated results: every recomputable number was internally consistent.
Scope of this review
Only the medRxiv PDF was available. The raw Finometer recordings, the analysis code and the supplementary Table S1 were not provided. The reported correlations, regressions and AUCs could therefore not be recomputed from data. Our checks are internal-consistency recomputations, numbers transcribed from the table images, and simulations with a reimplemented CWT pipeline (checked against ssqueezepy 0.6.5: HF within 1%, LF level about 18% different, time-course r ≥ 0.99). The simulations show that the paper's pattern can arise by construction. They cannot show how much of the observed association in the real cohort reflects genuine baroreflex physiology.