The arithmetic is internally consistent and the 0.8B edits reproduce exactly from public weights, but the paper reports no uncertainty, runs no baselines and has only one search per setting. Its own logs also suggest the large 0.8B gains mostly repair runaway, truncated reasoning, not add task-specific capability. Only the 0.8B Math/IFEval/SciBench gains are clearly outside noise.
Soundness
2/4
Presentation
3/4
Contribution
2/4
Confidence
4/5
✓ 12 confirmed
Summary
The paper is an empirical study of Weight-Space Programming (WSP): a proprietary LLM editor (GPT-6 Astra) gets a budget of 50 forward requests and a Python sandbox, and edits the weights of Qwen3.5-0.8B and Qwen3.5-9B directly, without gradients, for seven benchmarks (MATH-500, GPQA Diamond, MedXpertQA, MMLU-Pro, IFEval, SciBench, SciCode). The editor picks a final checkpoint on development feedback, and that checkpoint is then scored against the original on held-out data. The study covers 16 trajectories: one per model–benchmark pair, plus two reruns of 0.8B Math.
The main claims are: (i) small, localised edits give large held-out gains on 0.8B (MATH-500 +29.45 pp from a 1,023-value single-column edit; IFEval +36.72; SciBench +17.11; GPQA-D +4.42); (ii) edits transfer across tasks unevenly (the Math-edited 0.8B checkpoint gains +3.03/+12.18/+20.10 on GPQA/IFEval/SciBench); and (iii) outcomes are unreliable. Independent Math searches give +5.00 to +29.45 pp, 6 of 16 trajectories keep the original weights, and dev gains often fail to hold up (9B Math dev +29.69 vs held-out −0.35). The appendices fully specify every retained edit and log the primary Math search request by request.
No new method is proposed. The contribution is a characterisation of an existing approach (Takehi et al., 2026) across tasks and scales.
Strengths
Every retained edit is specified exactly enough to rebuild
App. C, Tables 6–7, Eqs. (3)–(6); App. D Table 8
App. C gives tensor names, indices, coefficients and the construction formula for every retained edit. We rebuilt the Math Primary edit from the public Qwen3.5-0.8B weights and tokenizer. It changes 1,024 FP32 / 1,023 BF16 values, exactly as stated (check 06). The logged Rerun-2 scale κ=1.672 reproduces as 1.6717 (check 07), and all ten weight-only BF16 counts for 0.8B and 9B match exactly (checks 08, 09). For an agentic, logs-heavy study this is unusually precise and makes the edits auditable.
Negative and null outcomes are reported, not hidden
Table 2; Sec. 3.2; Sec. 3.4; App. D
Table 2 marks the six trajectories where the editor kept the original weights (starred rows). Sec. 3.2 reports the 9B Math dev-to-held-out collapse (+29.69 → −0.35). App. D gives per-candidate confirmation numbers that show dev gains shrinking (e.g. 9B IFEval best-dev +13.89 vs +1.67 on a 1,920-answer confirmation, check 05). This candour is what makes the paper's 'Limitations' insight credible.
Fully auditable request-level log of the primary search
Sec. 3.3, Fig. 3; App. E Table 9
App. E lists all 50 requests of the 0.8B Math Primary trajectory, including failed edits and controls (ablation, reversed direction, random direction, dose sweep). Every count and delta in the log is internally consistent: 32 G / 18 TF requests, dose sweep 7,22,25,28,21,18/48, and reserved dev sets A–F 126→484 of 1,152 (10.94%→42.01%) (check 04).
Internally consistent numbers throughout
Abstract; Table 2; Figs. 1, 2, 5, 6
All 28 Table 2 deltas, the abstract's headline and transfer numbers, and the Fig. 2/Fig. 6 deltas recompute to within 0.01 pp (check 01). A GRIM-style granularity test shows every held-out accuracy can arise from integer counts for a single plausible sample count per benchmark (check 02). We found no sign of transcription errors in the main results.
Weaknesses
No uncertainty on any held-out result; several reported 'improvements' are within noise
major · Table 2; Figs. 1, 6; Abstract; App. A Table 4; App. B Eq. (2)
App. B Eq. (2) defines a clustered paired SE, but no held-out number in Table 2, Fig. 1, Fig. 2 or Fig. 6 carries an SE, CI or test (check 03). Our reference SEs give z<1.2 for 0.8B GPQA-D +4.42 (z≈0.99), 9B IFEval +1.85 (0.72), 9B SciBench +3.03 (1.18) and 9B SciCode +1.54 (0.59). The 9B SciCode gain is 2 vs 1 chain out of 65. Of the 16 transfer deltas in Fig. 6, only 4 exceed 2 SE (check 11), and the abstract's GPQA +3.03 transfer has z≈. The number of samples per item is never stated: App. A refers to a column of Table 5 that does not exist, so we had to infer it (check 02). report Eq. (2) SEs/CIs for every held-out and transfer number, state , and limit the 'improvement' language to effects that pass the test. The abstract's 'up to +4.42 on GPQA Diamond' headline needs this most.
Questions for the authors
What are the held-out truncation rates and mean response lengths before and after each retained edit? Is most of the 0.8B gain on MATH-500, IFEval and SciBench concentrated on questions where the base response hit the 32,768-token cap?
How does a simple logit bias against the tokens the Math edit suppresses (e.g. 'Wait', 'However', 'But'), or a shorter thinking budget, compare with the 1,023-value edit on MATH-500 and on the transfer benchmarks?
What are the Eq. (2) standard errors for every Table 2 and Fig. 6 held-out delta, and how many samples per item (n) were drawn for each benchmark?
What is the Math-edited 0.8B checkpoint's SciCode score, which the abstract describes as 'unchanged'?
If you ran two or three more independent trajectories for 0.8B IFEval and SciBench, would their held-out gains vary as much as the three Math searches (+5.00 to +29.45 pp)?
Is 21.40% for the 0.8B IFEval-edited checkpoint on MATH-500 (Fig. 6 panel B) correct, given that it equals the 0.8B IFEval base score exactly?
Verification
We ran 12 checks with scripts: 12 confirmed, 0 discrepancies, 0 inconclusive. We recomputed all Table 2, Fig. 2 and Fig. 6 deltas, the App. D/E logs and a GRIM-style granularity test. All were internally consistent. Using range reads of the public Qwen3.5 checkpoints, we rebuilt every weight-only edit and matched each reported BF16 count exactly. That includes the 1,023-value Math edit, the logged Rerun-2 scale κ=1.672, and the algebraic statements in App. C. Accuracy of the results is therefore not the issue. The issue is how much they can support: reference standard errors show that only the 0.8B Math/IFEval/SciBench held-out gains and 4 of 16 transfer deltas are clearly outside noise (checks 03, 11). The scale check of the Math edit and the transfer pattern point to a task-agnostic mechanism. We could not rerun any editing trajectory or evaluation, because no code, checkpoints or outputs are released and the editor is proprietary.
12Confirmed
✓ConfirmedAbstract; Sec. 3.2; Table 2; Sec. 3.4; Figs. 2, 5, 6
Takehi et al. 2026, 'Sparks of Weight-Space Programming' (takehi2026weightspace)
Non-archival research blog post (resolves; the cited 7.9% → 48.1% MATH-500 and 0.016% figures are present). It is the sole prior source for the method being characterised, so readers cannot check it against a peer-reviewed or versioned record. Note that the original edit reaches 48.1%, while this paper's best Math held-out result is 37.80%; the gap is not discussed.
Takehi et al. 2026, 'Weight-Space Programming: Complete Experiment Logs' (takehi2026logs)
In the bibliography but never cited in the text, although the editor prompt and harness (App. F) appear to come from this source. It should be cited where the harness is described.
Gupta, Rao, Anumanchipalli 2024, 'Model Editing at Scale leads to Gradual and Catastrophic Forgetting'
In the bibliography but never cited. It is directly relevant to the unreported cross-task regressions (e.g. 9B IFEval-edited → GPQA −3.79 pp) and should be discussed.
Kwon et al. 2023, vLLM / PagedAttention (kwon2023vllm)
In the bibliography but never cited; if vLLM was the inference engine, App. A should say so together with its version.
Suggestions
Report Eq. (2) clustered paired SEs or 95% CIs for every held-out and transfer delta, and state the per-item sample count n in Table 5.
Run at least three independent trajectories for the main 0.8B benchmarks and report mean ± spread. Frame the abstract numbers as typical rather than best-case.
Add baselines for the same failure mode (logit bias or decoding changes, thinking-budget limits) and a LoRA or few-step fine-tuning baseline with the same dev-data access.
Report held-out truncation rates and response lengths before and after each edit, and discuss the 'repair of degenerate reasoning' interpretation the introduction raises.
Mark discarded candidates in Fig. 1 and add the missing SciCode cell to Fig. 6. Mention negative transfer, such as 9B IFEval-edited → GPQA −3.79 pp, in the abstract.
Replace changed-BF16 count with rank and ∥Δθ∥F in Fig. 4, and base Fig. 5 on held-out or reserved-dev gains, not best-dev maxima.
Ethics and integrity
No ethical concerns about data or subjects. The paper's results depend on a proprietary editor model, and the code repository linked as the project's code contains only the paper PDF, which readers should know. We found no text in the paper or source that tries to instruct reviewers.
Scope of this review
The code repository holds only a PDF of the paper. No harness, evaluation code, edited checkpoints, traces or per-question outputs are available, and the editor (GPT-6 Astra) is proprietary. We therefore could not rerun any trajectory or held-out evaluation, compute the paired Eq. (2) standard errors, or rebuild edits that depend on activations (0.8B Reruns 1–2 fully, 0.8B IFEval, 9B MedXpertQA, 9B MMLU-Pro). The Fig. 6 values were read from the figure's PDF text layer. Our standard errors are reference values from the stated sample sizes, not the authors' paired statistic. Running the 0.8B and 9B models on the benchmarks was outside this review's CPU-only budget.
Careful dev/held-out separation and split documentation
Sec. 3.1, Table 1; App. B, Table 5, Eq. (2)
App. B documents disjoint dev and test sources for every benchmark (e.g. GPQA dev = Main minus Diamond; seeded 270/271 IFEval split; SciCode validation vs test chains), and Eq. (2) defines a question-clustered paired standard error. This is the right statistic for this design, even though it is not used.
Held-out 0.8B Math, IFEval and SciBench gains are far outside sampling noise
Table 2 (0.8B rows)
Using reference standard errors that ignore pairing (check 03), the held-out gains are z≈11.8 (MATH-500 +29.45), 9.4 (IFEval +36.72) and 10.2 (SciBench +17.11). Within the paper's evaluation protocol, these effects are real.
0.68
Fix:
n
One search per setting, while the only replicated setting varies by 24 pp
major · Sec. 3.1; Sec. 3.4 'Outcomes vary', Fig. 2; Fig. 5; App. A
Each model–benchmark pair has exactly one trajectory, except 0.8B Math, where three independent searches give held-out gains of +29.45, +5.00 and +27.30 pp (Sec. 3.4, Fig. 2). The abstract's headline is the best of those three, and every other number is a single draw from a distribution with evidently large spread. Search-to-search variance therefore dominates sampling noise, and none of the cross-benchmark or cross-scale comparisons (Fig. 5, 'larger gains at 0.8B on all seven benchmarks') accounts for it. Several protocols also differ mid-run: objectives changed after request 46 (Math Rerun 1), 27 (GPQA) and 26 (MedXpertQA) (App. A). Fix: at least three independent trajectories per setting on the main benchmarks, with mean ± spread reported.
No baselines, so 'alternative to gradient-based adaptation' is not assessed
major · Abstract; Sec. 1; Sec. 3.2; App. E (F32)
The paper compares edited checkpoints only to the unedited model. It never compares them to cheap interventions aimed at the same failure modes: a logit bias against the 'Wait/However/But' tokens that the Math edit suppresses (App. C), tuned presence penalty or thinking budget, LoRA or few-step fine-tuning on the same dev data, or matched-structure random edits evaluated on held-out data. The only random-direction control is one draw on 48 dev items at an 8k cap (App. E, F32; check 04). Without these comparisons the claim in the abstract and Sec. 1 that WSP offers an alternative to gradient-based adaptation is untested, and the practical value of 50 calls to a frontier editor model is unclear. Fix: add at least the logit-bias/decoding baseline and a LoRA baseline under equal dev-data access.
Gains are most plausibly task-agnostic repair of runaway reasoning, not task-specific capability
major · Sec. 1; Sec. 3.4 'Cross-task transfer', Fig. 6; App. A Table 4; App. C (Math Primary); App. D
Under the chosen decoding (thinking on, 32,768-token cap, presence penalty 1.5; App. A), the 0.8B baselines are very low: MATH-500 8.35%, IFEval 21.40%, SciBench 1.38%. Several facts suggest the large 0.8B gains repair degenerate, truncated reasoning, and that this repair transfers to any task. The Math edit subtracts a doubt-vs-progress token direction. App. D reports truncations cut from 502 to 296 (0.8B MedXpertQA) and from 58 to 2 (9B IFEval). Our check 06 shows the Math edit adds a unit vector to a column of norm 0.256, about a 4× change to one unit. In Fig. 6, off-target checkpoints score at least as high as the checkpoint retained for that target in 7/16 cells, e.g. the Math-edited 0.8B checkpoint scores 21.48% on SciBench vs 18.49% for the SciBench-edited one (check 11). The introduction itself asks whether WSP is more than 'repairing specific behavioural failures', yet the paper never reports held-out truncation rates or response lengths and does not discuss this reading. Fix: report held-out truncation and length before/after each edit, and stratify gains by whether the base response was truncated.
Figure 1 mixes retained and discarded checkpoints
minor · Fig. 1; Table 2 (starred rows)
Fig. 1 is captioned 'held-out performance following task-specific weight-space interventions', but its 9B Math (97.70→97.35) and 9B GPQA (80.05→81.06) 'Edited' bars are the starred, discarded candidates of Table 2. The editor kept the original weights there. The first figure a reader sees thus shows +1.01 on 9B GPQA as an intervention result. Fix: mark or remove discarded candidates and add error bars.
Best-development values are selected maxima on small reused batches
minor · Table 2 (dev columns); Sec. 3.4 'Model Scale and Baseline Headroom', Fig. 5; App. B
Table 2's 'Best Development' gains are maxima over adaptive comparisons. Their smallest consistent denominators are as low as 12 (9B SciCode), 36 (9B IFEval) and 48 (9B GPQA, 0.8B Math) (check 05). For 0.8B Math the value 14.58→58.33 is request F19, on a 48-question set that was also used to choose the dose (check 04). App. B acknowledges they are 'reported without correction', but Fig. 5 and the 'Scale and headroom' paragraph build a scale argument on them. Fix: base Fig. 5 on held-out or reserved-dev gains (e.g. the A–F sets for Math), or drop the comparison.
'Structure matters beyond scale' rests on three rank-one edits and a BF16-rounding axis
minor · Sec. 3.4 'Intervention Structure Matters Beyond Scale', Fig. 4; App. D Table 8
Fig. 4 contrasts 1,023, 1,037,572 and 1,981,083 changed BF16 values. All three Math edits are rank one. For the two dense rank-one reruns, App. D gives nearly identical FP32-changed counts (3,669,545 and 3,669,949 of 3,670,016), so the BF16 count mostly reflects the update magnitude relative to BF16 spacing, not intervention complexity. Check 12 reproduces both reported counts with a dense rank-one update cuv⊤ by tuning only c (c=0.0277 → 1,037,572; c=0.0844 → 1,981,083). At fixed c a random direction gives nearly the same count as the edit's own direction. With n=3 the figure is a counterexample, not a trend. Fix: use rank and Frobenius norm of Δθ as the scale axis, and soften the claim.
Abstract claims not shown in the paper and regressions not mentioned
minor · Abstract; Sec. 3.4 'Cross-task transfer', Fig. 6
The abstract says the Math-edited checkpoint leaves SciCode 'unchanged', but SciCode is not plotted in Fig. 6 and no number is given (checks 01, 11). The abstract does not mention negative transfer, although the 9B IFEval-edited checkpoint loses 3.79 pp on GPQA-D (80.05→76.26), larger than any 9B gain, and the Math-edited 0.8B loses 0.20 pp on MedXpertQA. 'Limited search budgets' lists only four of the six retain-original cases. Fix: report the SciCode number and the regressions in the main text.
Reproducibility depends on unreleased artefacts and a proprietary editor
minor · Abstract (GitHub link); App. A; App. C
The linked repository contains only a PDF of the paper (single commit). No editing harness, evaluation code, edited checkpoints, traces or per-question outputs are released, and the HuggingFace link is commented out in the source. Editor runs cannot be repeated because GPT-6 Astra is proprietary. Weight-only edits can be rebuilt (checks 06–09), but the Rerun-1, 0.8B IFEval, 9B MedXpertQA and 9B MMLU-Pro edits need unreleased activations. Fix: release checkpoints (or edit scripts), evaluation code with seeds, and per-question outputs so Eq. (2) can be recomputed.
MedXpertQA dev data come mostly from a different benchmark
minor · App. B, Table 5; Table 2 (MedXpertQA rows)
The MedXpertQA dev set is 1,273 MedQA-English test items plus 5 MedXpertQA items, while the held-out set is 2,450 MedXpertQA-Text items (App. B, Table 5). The 0.8B dev base (~45%) and held-out base (10.57%) differ widely, so failed dev-to-held-out transfer on this task may reflect a distribution shift built into the protocol, not a WSP limitation. This deserves explicit discussion.
Minor reporting inconsistencies
minor · App. A Table 4; App. B Table 5; App. F; bibliography; Fig. 6 panel B
App. A Table 4 sets the sample count to 'task-specific n (Table app-splits)', but that table has no n. The bibliography contains entries that are never cited (Takehi et al. experiment logs, vLLM), even though the editor prompt (App. F) appears to come from that harness. The 9B IFEval delta prints as +1.85, while the rounded table values give +1.84 (unrounded fractions; check 01). The 0.8B IFEval-edited score on MATH-500 (21.40) equals the 0.8B IFEval base score (21.40) to two decimals; please confirm this is not a copy error.
Algebraic interpretations of edits: (i) O-7u(u^T O) multiplies the u-component by -6; (ii) 9B MedXpertQA gate edit shifts all 256 head-11 gate logits equally, by -u^T applied to the pre-gain RMS-normalised residual; (iii) W-u e_507^T changes MLP output by -a_507 u
(i) residuals 1.2e-14; (ii) spread of 256 shifts 3.3e-13 and |shift + u^T n| = 1.1e-13; (iii) 4.0e-14. Qwen3_5RMSNorm computes output*(1.0+weight) with zero-initialised weight, and stored layer-19 weights are centred near 0 (mean 0.025, range -0.57 to 0.41; min |1+lambda| = 0.43, so g = u/(1+lambda) is well defined). The identities hold as stated.
Float64 numerical identity checks on random instances (seed 0, tol 1e-9); RMSNorm convention from transformers modeling_qwen3_5.py and stored 9B layer-19 input_layernorm weights
Cross-task transfer: Math-edited 0.8B improves GPQA/IFEval/SciBench and leaves SciCode unchanged; transfer is asymmetric and sometimes negative
All 16 values present in the figure and the stated numbers/directions reproduce (12/16 positive, 4/16 negative). Only 4/16 deltas exceed 2 SE_q, all on 0.8B: Math-edited on IFEval +12.18 (z 3.2) and SciBench +20.10 (z 11.3); IFEval-edited on Math +13.05 (z 5.9) and SciBench +1.90 (z 2.2). The abstract GPQA +3.03 has z 0.68. SciCode does not appear in Fig. 6, so the claim that the Math-edited checkpoint leaves SciCode unchanged has no displayed evidence. In 7/16 cells the transferred checkpoint scores at least as high as the checkpoint retained for that target (e.g. 0.8B Math-edited on SciBench 21.48 vs SciBench-edited 18.49; 9B SciBench-edited on IFEval 91.51 vs IFEval-edited 91.14), consistent with a shared, task-agnostic effect (e.g. curbing over-long reasoning) rather than task-specific capability; the paper does not discuss this. 0.8B IFEval-edited on MATH-500 (21.40) equals the 0.8B IFEval base value (21.40), a coincidence worth confirming.
Extracted all 16 values from the figure text layer; deltas vs Table 2 held-out bases; question-level SE_q of the unpaired difference; comparison with the retained on-target checkpoint (base value for starred rows)
Fig. 4 / Sec. 3.4 contrast the three Math edits by 'parameter scale' (1,023 vs 1,037,572 vs 1,981,083 changed BF16 values); App. D gives FP32-changed counts 3,669,545 / 3,669,949 for Reruns 1/2 of the 3,670,016-entry W23
Rank-one updates reproduce the reported footprints: c = 0.0277 gives BF16 1,037,572 (FP32 3,669,654 vs reported 3,669,545) and c = 0.0844 gives BF16 1,981,083 (FP32 3,669,911 vs reported 3,669,949). At fixed c the BF16 count is nearly the same for the Rerun-1 writer direction and a random u (e.g. c = 0.1: 2,123,405 vs 2,171,884; seeds 0-2 within about 3%), while FP32 changes touch >99.98% of entries for every c. So for dense rank-one edits the changed-BF16 count is a monotone function of update magnitude relative to BF16 spacing, not a measure of structural complexity. All three Math edits are rank one. Fig. 4's 'scale' axis therefore measures magnitude, not the number of independently chosen parameters. Caveat: the true v is not released, so this shows consistency, not the exact edit.
Real layers.23.mlp.down_proj of public Qwen3.5-0.8B; dense rank-one update W - c u v^T (u = Rerun-1 writer direction built from weights per Eq. eq:sel-math-r1, or random unit u; v random unit, seeds 0-2, since the true v needs unreleased traces); FP32 and BF16 changed counts over c in 0.02..1; bisection on c for the reported BF16 counts
Table 2 deltas equal Edited-Base; abstract/intro headline gains (+29.45, +4.42, +36.72, +17.11), transfer gains (+3.03, +12.18, +20.10), rerun gains (+5.00/+27.30) and "0.8B has larger best-dev gains than 9B on all seven benchmarks" follow from tabulated values
All 28 deltas match within 0.01 pp (9B IFEval 91.14-89.30=1.84 vs stated +1.85, a rounding of unrounded fractions). 0.8B dev gain exceeds 9B on all 7 benchmarks; max +43.75 on Math and IFEval. Abstract transfer +3.03/+12.18/+20.10 reproduce exactly from Fig. 6 panel A. Side findings: (i) SciCode is not plotted in Fig. 6 panel A, so the abstract statement that the Math-edited checkpoint leaves SciCode unchanged has no displayed evidence; (ii) Math-edited 0.8B on MedXpertQA is 10.37 vs base 10.57 (-0.20), not mentioned; (iii) 9B IFEval-edited loses 3.79 pp on GPQA (80.05 to 76.26); (iv) off-target edits match or beat the on-target Table 2 edit in several cells, e.g. 0.8B Math-edited SciBench 21.48 > SciBench-edited 18.49, 9B IFEval-edited SciBench 75.71 > 75.49, 9B SciBench-edited IFEval 91.51 > 91.14.
Recomputed all 28 Table 2 deltas, Fig. 2 gains and Fig. 6 transfer deltas (values from the figure PDF text layer) against Table 2 held-out bases; row-wise 0.8B vs 9B dev-gain comparison; tolerance 0.01 pp
Held-out accuracies are consistent with integer counts given the stated test-set sizes and a fixed number n of samples per item (n is never reported)
Every benchmark admits a common n: MATH-500 n in {8,12,16} (n=1 impossible: e.g. 8.35% is not a multiple of 0.2%), GPQA-D n in {4,8,12,16}, MedXpertQA n>=4, IFEval even n, MMLU-Pro and SciCode any n, SciBench only n in {14,15} within 1..16 (75.49% is infeasible at n=4, 8 or 16). So the numbers are internally consistent with real counts, but n must be inferred: App. A Table 4 says task-specific n is given in Table app-splits, which has no n column. Smallest consistent n: MATH 8, GPQA 4, MedXpertQA 4, IFEval 2, SciBench 14, SciCode 1 (1.54% = 1/65 chains, 3.08% = 2/65).
GRIM-style granularity test: for each benchmark and n=1..16 (SciBench 1..32), test whether integer k exists with round(100k/(N n),2) equal to every reported held-out value (Table 2, Fig. 2, Fig. 6)
Held-out gains (incl. 9B SciCode +1.54, 9B IFEval +1.85, 9B SciBench +3.03, 0.8B GPQA +4.42) are presented as improvements without any SE/CI, although App. Eq. (2) defines a clustered paired SE
The only SE/CI occurrences in the source are the definition of Eq. (2) and the editor prompt in App. F; no held-out number carries an SE or CI. Indicative z = delta/SE_q: 0.8B Math 11.8, IFEval 9.4, SciBench 10.2 (robust); 0.8B GPQA +4.42 z=0.99 (z_samp 1.97 with n=4); 9B IFEval +1.84 z=0.72 (z_samp 1.02); 9B SciBench +3.03 z=1.18 (z_samp 4.40); 9B SciCode +1.54 z=0.59, which is 1 vs 2 chains of 65 (best-case exact sign test p=1.00). Abstract transfer GPQA +3.03 has SE_q 4.45 pp. A paired, shared-seed SE could be smaller than these references, but it needs per-question data that are not released; the paper should report Eq. (2) itself. Conclusion: the 0.8B Math/IFEval/SciBench gains are far outside noise; the 9B gains, 0.8B GPQA gain and most transfer deltas are not shown to be distinguishable from noise.
Regex scan of all LaTeX sections for SE/CI/p-values; reference SEs of the unpaired difference per Table 2 row: SE_samp (independent samples, smallest n consistent with check 02) and SE_q (question-level); exact sign test for 9B SciCode
Math Primary trajectory: 32 G + 18 TF requests; row deltas; dose sweep 7,22,25,28,21,18/48; dev sets A-F 1,152 questions, 126->484 (10.94%->42.01%), 377 rescues and 19 regressions; Table 2 best dev 14.58->58.33
50 contiguous rows; 32 G / 18 TF as claimed; all graded deltas and denominators consistent; dose sweep reproduces 7,22,25,28,21,18; A-F total 1,152, 126->484 = 10.94%->42.01%; net +358 = 377-19. Table 2 best dev 14.58->58.33 is F19 (7/48->28/48), the maximum delta in the log. Context: F19-F23, F26, F28, F29 (8 requests) reuse the same 48-question discovery set, and the strength alpha=1 was chosen on it, so the Table 2 best-dev value is a selected maximum; the reserved sets A-F (+26.6 to +33.6 pp) are the unbiased dev evidence. The random-direction control is one draw on 48 items at 8k (10/48 vs 20/48).
Parsed the LaTeX longtable (50 rows), recounted request types, recomputed every graded delta (tol 0.01 pp) and denominators, summed dev sets A-F (F18, F35, F38, F39, F40, F50)
App. D candidate-selection numbers and IFEval dual-grader table are internally consistent and link to Table 2 dev cells
All stated values reproduce: MedXpertQA cand. A 21->32/64 = +17.19 (= Table 2 dev 32.81->50.00), 48->56/128 = +6.25, cand. B 1,376->1,356/3,072 = -0.65; 9B MMLU-Pro 1,611->1,613/1,792 = +0.11; 9B GPQA 261->259/360 = -0.56; IFEval 0.8B 55->167/256 = 21.48->65.23 (= Table 2 dev); 9B 1755->1787/1920 = 91.41->93.07 and 1767->1799 = 92.03->93.70; 120x16 = 1,920. The smallest denominators consistent with Table 2 best-dev cells are very small: 9B SciCode 12 (3->5 of 12), 0.8B SciCode 18, 9B IFEval 36, 9B GPQA 48, 9B Math 64. The 9B IFEval best-dev gain +13.89 (on about 36 answers) shrinks to +1.67 on the 1,920-answer confirmation and +1.85 held-out, illustrating that best-dev values are inflated selected maxima.
Arithmetic recomputation (tol 0.01 pp); search for the smallest denominators reproducing each Table 2 best-dev cell
Math Primary edit W23[:,507] -= u (u from doubt-vs-progress token readouts) changes 1,023 of 1,024 BF16 entries (FP32: 1,024)
All 13 words tokenize to single tokens without a leading space. FP32 changed 1,024, BF16 changed 1,023 (claimed 1,024 / 1,023); the unchanged entry is row 400 (|u| = 3.5e-6 below BF16 spacing). The count is insensitive to the gain convention ((1+gamma), gamma, or none all give 1,023) but sensitive to tokenization (leading-space tokens give 1,021), so it supports the stated recipe. Scale: ||u|| = 1 versus ||W23[:,507]|| = 0.256, so the edit adds a vector about 4x the original column norm, i.e. it is a large change to one unit, not a subtle perturbation. The stored final-norm weights have mean 3.31 (range -0.78 to 5.31), i.e. not centred at 0.
HTTP range reads of public Qwen/Qwen3.5-0.8B tensors (embedding rows, final norm, layers.23.mlp.down_proj) and tokenizer; u built in float64 exactly as Eq. (eq:sel-math-primary); edit applied in float32; BF16 round-nearest-even comparison
Math Rerun 2: logged RMS(h)=4.016 and kappa=1.672 are consistent with kappa = RMS/|u^T r(Wait)|, u = -N(P_perp_{S_P} r(Wait)) computed from embeddings, final-norm gain and tokenizer
|u^T r(Wait)| = 2.4023 (required band 2.4009-2.4029), giving kappa = 1.6717 vs logged 1.672. The check discriminates: r=E*gamma gives kappa 2.162, and the leading-space token " Wait" gives 1.741 / 2.252. This confirms both the formula as written and the (1+gamma) effective-readout convention, and indicates the appendix specification matches what was run.
Computed r(t)=E_t*(1+gamma) for first tokens of </think>, <|im_end|>, newline, digits 0-9 and Wait from public Qwen3.5-0.8B weights; QR projection; compared 4.016/|u^T r(Wait)| with 1.672 within the rounding band of both logged values; alternative conventions as negative controls
All five counts reproduce exactly: 262,144 / 262,144 / 21,504 (21 columns in 8 layers) / 787,456 / 263,168. Layers 11, 15, 23 are full_attention (full-attention layers 3,7,11,15,19,23); o_proj is 1024x2048 (8 heads x 256). No zero entries in the edited blocks, so nominal and BF16 footprints coincide. Not reproducible from weights alone: Reruns 1/2 and the IFEval edit (258,128) need trace activations that are not released.
Range-read the relevant o_proj and down_proj tensors of public Qwen3.5-0.8B; applied each edit as specified; counted BF16 differences; layer types from config.json
Weight-only 9B edits change the stated BF16 counts (Math 4,096; GPQA 1,048,576; IFEval 4,096; SciBench 24,576; SciCode 1,048,576); layers 19/23 are full attention; q_proj 8192x4096 with head-11 gate rows 5888-6143
All five counts reproduce exactly. Layers 19 and 23 are full_attention; q_proj.19 is [8192, 4096]; transformers splits each head into [query 256 | gate 256], so head 11 gate rows are 5888-6143 as stated. Scale note: the 9B IFEval edit multiplies column 5032 (norm 0.746, median column norm 0.705) by -32, i.e. a 32-fold amplified, sign-flipped write direction. The MedXpertQA (1,047,586) and MMLU-Pro (41,054,142) counts depend on unreleased activations and were not checked.
Range-read W21, W16, W31 (down_proj) and O23 (o_proj) of public Qwen3.5-9B; applied edits; counted BF16 differences; q_proj layout read from transformers modeling_qwen3_5.py (view(..., head_dim*2) then chunk)
Release the editing harness, evaluation code, edit scripts or checkpoints, and per-question outputs, and restore the HuggingFace link.