A useful metric with a clean scaling analysis and working, reproducible code, but the headline 'decays only linearly' holds only for errors far from any matching curve (sub-tolerance shifts decay quadratically, confirmed with the authors' code), and the RL and test-time-verifier results are confounded or not reproducible as reported.
Soundness
2/4
Presentation
3/4
Contribution
3/4
Confidence
4/5
✓ 12 confirmed✕ 2 discrepancy◐ 3 inconclusive
Summary
The paper argues that the standard geometric metrics for generated CAD models (volumetric IoU, Chamfer Distance, surface F-score, Edge Chamfer Distance) barely penalise small local errors such as a missing hole or a slot on the wrong face. It writes all of them as an average of a penalty ρ over a k-dimensional domain (Eq. 1, Table 1) and argues that a local error of relative size t receives weight ∝tk+, where is the growth order of the penalty (Eq. 3-4).
Strengths
Unifying integral view of CAD metrics with a testable scaling law
Sec. 2.1-2.4, Eq. (1)-(4), Table 1
Eq. (1) and Table 1 cast IoU, CD, F-score, ECD and DrawScore as one directional-distance integral with a penalty and an aggregation. This gives a simple, falsifiable explanation (w∝tk+q) of why volume and surface metrics under-weight small features. The algebra checks out: the IoU aggregation RP/(R+ and Eq. (7) are exact identities (check 06). An independent re-implementation on a synthetic box reproduces the orders for a removed hole: IoU 3.00, CD 3.00, F 2.30, ECD 0.89, DS 0.97 (check 04).
Weaknesses
'Decays only linearly' is false for errors near a matching curve (confirmed discrepancy)
major · Abstract; Sec. 2.4 Finding 2; Table 1; Sec. 5.1 / Fig. 3; Sec. 7.1 / Fig. 6a
The abstract, Table 1 (order 1 with no asterisk, unlike ECD) and Finding 2 ('a saturating penalty never does' speed up the decay) state order 1 for DrawScore without any condition. The Gaussian penalty 1−e−d2/2σ2 is quadratic for (local exponent 2.00 at ). In a 2-D drawing model, a shrinking notch with corresponding geometry nearby gives order 2.97 for and 1.15 only for (check 05). With the , shifting a mm through-hole by - mm gives , saturating at about 0.16 beyond (check 17). Order 1 therefore holds only for errors farther than about from any curve with the same visibility. That covers the motivating cases (a missing hole, a slot on the wrong face), but not small dimensional or positional errors. The paper's own Fig. 4b (0.9 mm shift, Gaussian penalty 0.28 rather than 1) lies in the reduced regime. All decay-order evidence (Fig. 3, Fig. 6a) uses a removed hole, where -independence holds by construction (checks 13, 14). Fix: state the condition in the abstract, Table 1 and Finding 2. Add a sweep over shifted or resized features, and discuss which regime matters for manufacturing tolerances.
Questions for the authors
How do invalid outputs enter the IoU/F/ECD/DS means in Table 2? Do they count as 0, or are means taken over valid outputs only? If the former, does the RQ3 conclusion survive in per-valid terms?
In RQ4, exactly how is DrawScore computed against the input drawing without a 3D model: registration, scale, choice of L, view alignment? Why does DS selection reach only 0.591 when the DS oracle is 0.716, given that the drawing is the GT's projection?
What decay order do you measure for shifted or resized features whose displacement is below or near σ? Do you agree that Table 1's order 1 needs the same qualification as ECD's?
In RQ2, what are the Spearman correlation between IoU and DS and the discordance rates at quantile-matched thresholds? How many of the 190 IoU-high/DS-low outputs did you inspect, and what fraction had genuine manufacturing-relevant errors?
How are CD and F-score computed (sample-to-sample or sample-to-surface distances)? With 50,000 samples, sample-to-sample distances leave a noise floor that would flatten the Fig. 3 slopes.
Were the RL runs repeated with different seeds, and what is the run-to-run variance of each column in Table 2?
Which six agent configurations produced the 1,188 RQ2 outputs?
Verification
We ran 17 checks: 12 confirmed, 2 discrepancy, 3 inconclusive. All reported percentages, table directions and Valid% fractions are internally consistent, and the figure values (Fig. 1, 3, 5, 6) were recovered from the vector PDFs and match the text. We installed and ran the released metric code: it matches Sec. 3, its tests pass, and it reproduces the blind-hole decay order (0.974 vs 0.96). An independent re-implementation also reproduces the Table 1 orders for a removed hole. Both discrepancies concern the unconditional 'order 1' claim for DrawScore. A Gaussian-penalty analysis and the released code itself both show quadratic decay for sub-tolerance positional errors (order 2.04). The RQ3 'not from validity alone' claim is inconclusive because the paper does not say how invalid outputs are scored; under the common zero-score convention it fails. The RQ4 verifier claim is inconclusive because the drawing-only scorer is neither described nor released. The reference check is inconclusive for 5 of 29 entries. The RQ1-RQ4 experiments themselves could not be rerun because their data and code are not released.
Cited in Table 1 as the source of Chamfer Distance. Occupancy Networks uses CD but did not introduce it; the introduction cites Fan et al. 2017 (fan2017pointset) for the same metric. Table 1 should cite consistently.
cmecad (CME-CAD, CVPR 2026)
Could not be resolved. tools/check_refs.py gave only a partial match (overlap 0.55): Crossref returned a different paper ('From Intent to Execution: Multimodal Chain-of-Thought Reinforcement Learning ...'), and the CVF open-access PDF returned HTTP 403. Existence and bibliographic details are unverified.
willis2021fusion (Fusion 360 Gallery, ACM TOG 2021)
Flagged NOT MATCHED by check_refs.py only because Crossref stores the title truncated as 'Fusion 360 gallery'. Authors, venue and DOI are consistent, so this is very likely a false alarm. Listed for completeness.
Web-only, but the page exists and does describe rigid, no-scale registration (24 PCA orientations plus ICP), which supports the registration citation. The metrics page itself does not state the 20-degree normal-consistency criterion or the F-score threshold that the paper attributes to CADGenBench (Sec 4, 'following CADGenBench ... normals within 20 degrees'). The fetched shape_similarity.md URL returned 404, so the attribution could not be verified.
benchcad2026public (BenchCAD 2.0 public set)
The repository exists and T1 is drawing-to-CadQuery. Its README says public-set scores are meant for trying the harness, not for reporting. The paper nevertheless reports RQ4 results (Table 3) on 20 valid Public T1 cases without acknowledging this caveat.
Web-only manual with no DOI or URL that check_refs.py could resolve; the closest Crossref hit is an unrelated news item. Unverified. It is cited only for the general practice of engineering drawings, so it is low impact.
ortho2cad (arXiv 2607.08891)
The reference exists and matches. Related-work point: Ortho2CAD already uses self-refinement that compares projections of the generated model with the input drawing. That anticipates the paper's argument that the input drawing enables test-time verification (Sec 1, RQ4), and the paper does not discuss it in that context.
Suggestions
Qualify the decay-order statement in the abstract, Table 1 and Finding 2: order 1 holds for errors farther than about 2σ from any same-visibility curve, and the order is about 2-3 for sub-tolerance shifts or resizes. Add a controlled sweep for that regime.
Add a per-valid version of Table 2, state the invalid-output convention, and report at least 3 seeds with confidence intervals.
Describe and release the drawing-only DrawScore used in RQ4, explain the gap between DS selection and the DS oracle, and evaluate on more than 20 cases with bootstrap CIs.
Replace the shared 0.95 threshold in RQ2 with quantile-matched thresholds and rank correlations, and include a joint IoU-DS scatter plot with annotated examples from the discordant quadrant.
Release the experiment scripts (baseline metrics, RQ1 models, RQ2 outputs, RL rewards) and include the supplementary material in the arXiv version.
Report fitted slopes with confidence intervals instead of a fixed 0.2 tolerance, and specify how CD and F distances are computed.
Report the runtime per comparison and its overhead in RL training and best-of-N selection.
Discuss Ortho2CAD's projection-based self-refinement and the Light Field Descriptor as the closest prior uses of projections, and cite Chamfer Distance consistently.
Ethics and integrity
No integrity concerns. Every recoverable number is internally consistent, and figure data reconstruct exactly to the stated counts. The paper includes an LLM-usage statement (writing, literature search, drafting). The materials contain no text that attempts to instruct reviewers. The paper does not mention that the BenchCAD public set is described by its maintainers as not intended for reporting scores.
Scope of this review
The paper, LaTeX source and the released metric code were examined, and the metric was run on synthetic build123d models. We could not rerun RQ1-RQ4 because the controlled CAD models, agent outputs, baseline metric implementations, RL training code and checkpoints, and the drawing-only RQ4 pipeline are not released. The supplementary material cited for the 53 RQ1 comparisons and the discretisation settings is not part of the arXiv version. We could not verify the model names (Qwen3.8-max, Qwen3.5-4B) or the non-public parts of BenchCAD and Ortho2CAD.
Guided by this, it proposes DrawScore: both models are projected into front/top/right views with visible and hidden lines (as in engineering drawings), compared along the 1-D curves with a saturating Gaussian penalty (Eq. 5-6), combined by a per-view harmonic mean, and the minimum over views is taken. The paper claims that DrawScore's weight on a local error decays only linearly (order 1).
Four research questions support the claim: a blind-hole sweep whose fitted slopes match the predicted orders (RQ1, Fig. 3); 1,188 agent outputs where 18.9% of IoU≥0.95 outputs have DS<0.95 but only 1.2% the other way round (RQ2); DrawScore as an RL reward with Dr.GRPO on Qwen3.5-4B (RQ3, Table 2); and best-of-8 selection against a simulated input drawing on 20 BenchCAD cases (RQ4, Table 3). The metric code is released under Apache-2.0.
P−
RP)
Released metric code matches the paper and runs
Sec. 3, Sec. 4.3; code drawscore/metric.py, projection.py
The Apache-2.0 package installs from its lock file, all 11 tests pass, and identical models score exactly 1. The round-vs-square hole example of Sec. 3.4 behaves as described: only the top view drops (0.966), and DS equals the minimum over views. The code implements the Gaussian penalty, separate visible/hidden unions, and angular samples shifting the projection by 0.707σ<σ (check 12). The paper's blind-hole decay order is reproduced with this code: 0.974 vs 0.96 claimed, stable over σ∈[0.001L,0.02L] (check 13).
Figures report exact numbers that are internally consistent
Fig. 3, Fig. 4, Fig. 5, Fig. 6
Fig. 3 slopes refitted from the vector markers match the legend to 0.03 (check 03). Fig. 6 decay orders (0.961-0.971) and Spearman labels (min 0.842) match (check 14). Fig. 5 bin counts reconstruct to exact integers that agree with the 190/1,007 and 10/827 counts in the text (check 02). The Fig. 4 cases satisfy the saturating bound 1−S≤p (check 11).
Honest case studies that also expose DrawScore's own blind spots
Fig. 2 (p4); Sec. 7.3
Fig. 2 does not cherry-pick. It shows cases where DrawScore is less sensitive than IoU (filled wheel opening: IoU 61.97 vs DS 90.20) alongside cases where it is far more sensitive (widened connecting web: DS 27.28 vs F1 79.18). This supports the nuanced message that no metric dominates. Sec. 7.3 also states limitations candidly (internal cavities, vector-only drawings, runtime).
Practically motivated use as a ground-truth-free verifier
Sec. 1; Sec. 5.3-5.4; Table 2
Point (iii) of Sec. 1 is useful and fits the drawing-to-CAD setting: there the input drawing is available at test time, so a drawing-level metric can rank candidates without 3D ground truth. Table 2 is carefully reported: all 25 direction markers are correct, and every Valid% is a valid k/153 fraction (check 07).
d<σ
0.1σ
s≪σ
s≫σ
released code
r=8
δ=0.1
0.8
1−DS∝δ2.04
3σ
2σ
σ
RQ3 'gains do not come from validity alone' depends on an unstated convention
major · Sec. 5.3; Table 2; RQ3 answer box
Table 2 does not say how invalid outputs enter the means. If they score 0, which is plausible given SFT IoU 0.338 at 75.2% validity, then per-valid DS falls from 0.322 (SFT) to 0.304 (DS reward). That result survives all rounding extremes (0.3046 < 0.3209), and every RL reward lowers per-valid DS (check 08). Under that reading, the DS-reward gains in F and DS are explained by validity, which contradicts the RQ3 answer box. In addition, the IoU reward beats the DS reward on Valid (93.5 vs 89.5), IoU (0.484 vs 0.445) and F (0.407 vs 0.369). Validity→DS reaches DS 0.244, only 0.002 above SFT (check 07). Each configuration is a single run on 153 test items with no seeds or confidence intervals. Fix: state the convention, add per-valid metrics, and report several seeds with CIs.
RQ4 verifier: the test-time scorer is undescribed, unreleased and evidently differs from the evaluation DS
major · Sec. 5.4; Table 3; RQ4 answer box; code drawscore/step.py
The input drawing is simulated from vector projections of the ground truth, and evaluation DS is also computed from the GT's three views. If the two scorers were the same, DS selection would reach the DS oracle (0.716). It reaches 0.591, so the drawing-only scorer differs in some way: registration, scale or L (check 10). The released scorer cannot run without a 3D reference STEP, which it uses for PCA+ICP alignment, inertia-based canonicalisation and the bounding box. So the central 'without 3D ground truth' claim cannot be reproduced. The gains are small and uncertain. With n=20 and no CI, IoU improves by +0.010. ECD gets worse (31.79→33.47). The recomputed IoU share of the Oracle gain is 5.1% from the printed values (4.7% is reachable only at a rounding extreme), CD is 17.2% and F is 12.8% (check 09). The BenchCAD README says that public-set scores are not meant for reporting. Fix: describe and release the drawing-only pipeline, explain the 0.125 gap, and use more cases with bootstrap CIs.
RQ2 asymmetry is mostly explained by DS being stricter at a shared threshold
major · Abstract; Sec. 1; Sec. 5.2; Fig. 5
The counts are arithmetically correct (check 01). However, IoU≥0.95 holds for 84.8% of outputs and DS≥0.95 for only 69.6%. A strictly monotone but harsher function of IoU would therefore already give 17.9% and 0.0%, versus the observed 18.9% and 1.2%. Of the 190 'IoU-high, DS-low' outputs, 180 are forced by the marginals alone. The data thus show that DS is stricter, not that it measures 'different aspects of geometric error'. Fix: use quantile-matched thresholds, a rank correlation and a joint scatter, and manually audit a sample of the 190 cases to show they contain real errors.
Most results cannot be regenerated from the released material
major · Sec. 4; Sec. 4.3; code repository
The supplementary material (53 RQ1 comparisons, discretisation settings, training details) is not in the arXiv version. The six agent configurations of RQ2 are not named. Not released: the RQ1 models, the RQ2 outputs, the IoU/CD/F/ECD implementations, the RL code and rewards, the scale-normalised RQ3 variant, and the RQ4 pipeline. Only the metric itself can be run. Implementation details also matter: with the stated 50,000 samples and sample-to-sample nearest-neighbour distances, two identical boxes give CD×103=6.18 and 1−F=0.126, and the CD/F slopes collapse to 0.14/0.07 (check 04). The authors must therefore compute CD and F differently from what Sec. 4 suggests. Fix: release the evaluation scripts and data, and specify the baseline metrics precisely.
Slope tolerance of 0.2 is arbitrary; the deviations are systematic
minor · Sec. 5.1; Fig. 3
The 95% CIs from the 6-point fits exclude the predicted order 1 for ECD (0.77-0.94) and DS (0.94-0.98) (check 03). In our re-implementation the F slope is 2.30, outside the paper's own 0.2 criterion, because holes with r≈τ distort the scaling (check 04). Report CIs and explain the systematic offsets rather than using a fixed tolerance.
Fig. 5 normalisation differs from the text
minor · Fig. 5 caption
The histograms are normalised over plotted outputs only. The 14 and 1 outputs below the 0.70 axis clip are dropped from the denominator, so the plotted fractions (17.7%, 1.1%) differ from the stated 18.9% and 1.2% (check 02). The caption should say so.
Eq. (7) approximation hides one-sided errors
minor · Sec. 3.5, Eq. (7)
The second-order term of 1−Sv is (a−b)2/4. The approximation (a+b)/2 is exact only when a=b and underestimates one-sided errors by 5-20% (a=0.4,b=0: 0.250 vs 0.200) (check 06). Worth a sentence, since one-sided errors (missing features) are the motivating case.
Runtime is listed as a limitation but not quantified
minor · Sec. 7.3; Sec. 5.3-5.4
One comparison takes about 7.5 s on 2 CPU cores with the released code (check 12). This matters for the RL reward (many rollouts per step) and for best-of-N. Report wall-clock costs for the training and selection settings.
Citation and related-work gaps
minor · Table 1; Sec. 4.3; Sec. 6
Table 1 cites Occupancy Networks [20] for Chamfer Distance, while the introduction cites Fan et al. [7]. Ortho2CAD already compares projections of the generated model with the input drawing during self-refinement, which anticipates the test-time-verification argument but is not discussed in that context. The 20° normal-consistency criterion attributed to CADGenBench could not be found on its metrics page. Light Field Descriptor and 2-D chamfer metrics on line drawings are natural baselines that are mentioned but not compared.
In RQ4 DS compares each candidate with the input drawing (vector projections of the GT); DS selection reaches DS 0.591 vs Oracle 0.716
If the test-time scorer equalled the evaluation DS, DS selection would reach the DS oracle (0.716); the reported 0.591 (gap 0.125) shows the two differ. The released scorer needs a 3D reference STEP: it samples both 3D surfaces for PCA+ICP alignment, uses the reference inertia for canonicalisation and the reference bounding box for L and the camera centre; there is no drawing-input path. The drawing-only variant used in RQ4 (presumably without 3D registration) is neither described nor released, so the claim that DS is a GT-free verifier cannot be reproduced and the size of the registration effect is unknown.
Logic check (selection by the evaluation scorer must equal the oracle) plus static inspection of the released scorer
Fig 4: smooth waist DS 79.55% with p=45.80%; bolt holes shifted 0.9 mm (tau=1.1 mm) keep F1 at 100% and DS 95.94% with p=15.90%
(a) 1-S=0.2045<=p=0.458; (b) 1-S=0.0406<=p=0.159. Predicted 1-S for (b) lies in [0.0236, 0.0452] and the observed 0.0406 falls inside. Implied L=220 mm. Note: at d=0.9 mm the Gaussian penalty is only 0.28 (vs 1 for a far error), i.e. this sub-tolerance error gets a reduced, distance-dependent penalty, which is relevant to the decay-order claim (check 05).
Checked the saturating bound w=1-S<=p; predicted 1-S for case (b) from p and the Gaussian penalty for displacement profiles between delta|cos phi| and constant delta, via Eq. (7)
Released code implements DrawScore as described (Gaussian penalty, visible/hidden separate, merged curves, 8 angular samples shifting the projection by < sigma, harmonic mean per view, min over views); identical models score 1
pytest: 11 passed. Identical models: DS=1.0000000000. Round vs square through-hole of equal width (Sec 3.4 example): per-view S = front 0.9998, top 0.9660, right 0.9998; DS=0.9659 = min (mean would be 0.9885), as described. Slot moved from the top to a side face: DS=0.8604. Angular samples move a point at L/2 by 0.707*sigma (< sigma) for tol 0.001/0.005/0.02. Each comparison takes ~7.5 s on 2 CPU cores. Code reads only Gaussian penalty (metric.py), separate visible/hidden unions, min over views, matching Sec 3.
Installed the locked environment (uv sync --locked, Python 3.12), ran the test suite, scored synthetic build123d STEP models and computed per-view scores with the package internals
DrawScore decay order on the blind-hole sweep is 0.96 and stays 0.96-0.97 for sigma from 0.001L to 0.02L
Fitted orders 0.974 (sigma=0.005L), 0.972 (0.001L), 0.980 (0.02L) vs paper 0.96-0.97 (tolerance 0.1; our part differs from the authors unreleased part). 1-DS ranges from 5.7e-3 (r=1) to 8.5e-2 (r=16) and is nearly identical across tolerances, because the removed hole has no corresponding curve of the same visibility within any of the tested sigma; ~7 s per comparison.
Released code (score_drawscore, full registration pipeline) on a 150x120x104 mm box with a centred blind hole r in {1,2,4,8,12,16} mm, depth 2r, vs the plain box; OLS slope of log(1-DS) vs log r at three tolerances
DS decay order stays 0.96-0.97 for sigma 0.001L-0.02L; Spearman vs default >= 0.84; twentyfold range
Five tolerances sampled (0.001, 0.0025, 0.005, 0.01, 0.02 L). Decay orders 0.961, 0.961, 0.961, 0.961, 0.971 (claimed 0.96-0.97). Spearman 0.885, 0.961, 1.00 (default), 0.954, 0.842; minimum 0.842 at 0.02L, matching labels 0.88/0.96/0.95/0.84. 0.02/0.001=20. Note: the decay order is again measured only on the removed-hole sweep (error far from any candidate curve), where sigma-independence is expected by construction.
Extracted marker positions from the vector figure (log x-axis) and mapped to data units
Fig 1: candidate A IoU 96.85% / DS 54.75%, candidate B IoU 98.23% / DS 96.25% (similar IoU)
Figure and README agree (96.85, 54.75, 98.23, 96.25); IoU gap 1.38 pp (commented text says 1.4), DS gap 41.50 pp. Only internal consistency was checked: the three STEP models are not released, so the scores themselves cannot be recomputed.
Extracted numbers from the vector figure and README and recomputed gaps
Cited works exist and match the bibliographic details (29 entries incl. 2026 arXiv preprints and web resources CADGenBench metrics and BenchCAD 2.0)
24/29 references matched with title overlap 1.00, including all four 2026 arXiv preprints (Ortho2CAD, IterCAD, OmniMech, CADTests). Not established by the tool: willis2021fusion (NOT MATCHED only because Crossref stores the truncated title "Fusion 360 gallery"), cmecad (partial: Crossref returned a different paper, CVF PDF 403), and three web-only resources (cadgenbench2026metrics, benchcad2026public, solidworks2011teaching). Manual fetches showed the CADGenBench metrics page and BenchCAD 2.0 repo exist; those fetches are not script output, so the claim as a whole is left inconclusive. Citation-content issues are listed in work/ref_issues.json.
python3 tools/check_refs.py work/references.json (Crossref/arXiv lookup), summarised by 16_refs.py; manual WebFetch spot-checks of CADGenBench metrics.md, BenchCAD 2.0 repo, CME-CAD CVF PDF and Ortho2CAD arXiv page
(Supplement to 05) The weight of a local error in DrawScore decays only linearly (Abstract; Table 1 order 1), tested with the released code on a positional error that has corresponding geometry nearby
1-DS = 5.7e-4, 2.28e-3, 1.06e-2, 3.81e-2 for delta = 0.1, 0.2, 0.4, 0.8 mm: fitted order 2.04 (quadratic), saturating at ~0.16 for delta >= 3 sigma. Exact 1-IoU grows linearly (1.8e-4 ... 1.4e-3). DS remains larger in absolute terms, but for sub-tolerance positional/dimensional errors its weight decays faster than linearly, contrary to the unqualified order-1 statement; the papers order-1 regime requires errors farther than ~2 sigma from any same-visibility curve.
Released code: box with a through-hole r=8 mm vs the same hole shifted by delta in {0.1,...,6.4} mm (sigma=1.09 mm); fitted order of 1-DS in delta below sigma; exact 1-IoU of the same pairs for comparison
Among 1,007 outputs with IoU>=0.95, 190 (18.9%) have DS<0.95; among 827 with DS>=0.95, 10 (1.2%) IoU<0.95, 817 (98.8%) IoU>=0.95 (1,188 outputs)
Arithmetic confirmed: 190/1007=18.87%, 10/827=1.21%, 817/827=98.79%; joint table [[817,190],[10,171]] sums to 1188 and both sides agree on 817. Caveat for the interpretation: marginals differ (84.8% vs 69.6% above 0.95), so 180 of the 190 IoU-high/DS-low outputs are forced by marginals alone; a strictly monotone but harsher metric would give 17.9% and 0.0% vs observed 18.9% and 1.2%. Only 20 discordant outputs (10+10) exceed this baseline, so the asymmetry mainly reflects DS being stricter at the shared 0.95 threshold.
Recomputed percentages and the implied 2x2 joint table; compared with a monotone-harsher-metric baseline having the same marginals
Fig 5 histograms: blue (DS | IoU>=0.95) has 190/1007 below 0.95; orange (IoU | DS>=0.95) has 10/827 below 0.95; axis clipped at 0.70
Each histogram sums to exactly 1.000 over the plotted range, i.e. it is normalised over plotted outputs only. Bar heights times N are exact integers (max deviation 0.000) for N=993 (blue) and N=826 (orange), implying 14 and 1 outputs below 0.70 are omitted. Reconstructed counts below 0.95: 176+14=190 (blue) and 9+1=10 (orange), matching the text. Minor: the caption says the axis is clipped, but not that the omitted 14 and 1 outputs are also removed from the normalisation, so plotted fractions (17.7%, 1.1%) differ slightly from the text (18.9%, 1.2%).
Extracted every bar rectangle from the vector PDF, mapped heights to relative frequency via tick labels, and reconstructed integer bin counts
Fitted log-log slopes IoU 3.00, CD 2.85, F 2.18, ECD 0.85, DS 0.96, each within 0.2 of k+q (3,3,2,1,1)
Markers sit at log10 r for r in {1,2,4,8,12,16}. Refit slopes 3.001, 2.853, 2.184, 0.853, 0.963 match the legend (tolerance 0.03); |slope-(k+q)| = 0.00, 0.15, 0.18, 0.15, 0.04 < 0.2. 95% CIs: CD 2.60-3.11, F 2.02-2.35, ECD 0.77-0.94, DS 0.94-0.98; the ECD and DS intervals exclude the predicted value 1, so the 0.2 tolerance is a loose, unjustified criterion (the deviations are systematic, not noise). Only one error type (a removed hole) is tested.
Extracted the 6 plotted markers per metric from the vector figure, mapped to data units via tick labels, refit OLS slopes with SE and 95% CI (df=4)
For a removed blind hole (radius r, depth 2r), weights scale as r^3 (IoU), r^3 (CD), r^2 (F), r^1 (ECD, no nearby edge), r^1 (DS)
Slopes: IoU 3.00 (paper 3.00), CD 3.00 with exact distances (paper 2.85), F 2.30 (paper 2.18), ECD 0.89 (paper 0.85), DS 0.97 (paper 0.96); tolerance 0.35 on the order. The orders predicted by Table 1 are reproduced for this error type. Two caveats: (i) F is steeper than 2 because holes with r comparable to tau lose more than proportional area above the tolerance, and in this geometry exceeds the papers own 0.2 criterion, so the fitted value depends on the size range; (ii) with sample-to-sample nearest-neighbour distances on 50,000 points (the stated sampling) the noise floor dominates (identical boxes give CD*1e3=6.18, 1-F=0.126; slopes 0.14 and 0.07), so the paper must compute CD/F differently; this implementation detail is not stated and the baseline metric code is not released.
Independent re-implementation on a synthetic 150x120x104 mm box (L=218 mm) with exact IoU, 50k-sample CD/F (both sample-to-sample KD-tree and exact point-to-surface distances), 20k-sample ECD and a 3-view 2-D drawing model for DS; fitted log-log slopes over r in {1,2,4,8,12,16}
A saturating penalty never speeds up the decay of a local error; DrawScore decay order is 1 (Table 1 without the asterisk given to ECD; abstract: weight decays only linearly)
The Gaussian penalty behaves as d^2/(2 sigma^2) below sigma (local exponent 2.00 at d=0.1 sigma, 1.54 at sigma, 0.10 at 3 sigma). Removed hole: fitted order 0.97 (matches paper 0.96). Notch with nearby geometry: order 2.97 for s<<sigma, 2.62 around sigma, 1.15 for s>>sigma. Hole radius error: 1-S ~ delta^1.99. So DrawScore has order 1 only when the error is far (>~2 sigma) from any corresponding curve; for small dimensional/positional deviations it is order 3, the same as IoU/CD. Table 1 and the abstract state order 1 without this condition; Sec 2.4 as long as the distance exceeds the tolerance implies it but Finding 2 says never.
(a) local log-log exponent of the Gaussian penalty; (b) 2-D drawing model with Eq. (6) recall/precision and harmonic mean, sigma=1.1 mm on a 220 mm-diagonal outline: removed hole, shrinking rectangular notch with nearby corresponding geometry, and hole-radius error
Both identities simplify to residual 0 (numeric max residual 3.3e-16). Second-order term of Eq. (7) is (a-b)^2/4, so the approximation is exact when a=b and underestimates 1-S_v by 5-20% for one-sided errors (a=0.1,b=0: 0.0526 vs 0.0500; a=0.4,b=0: 0.250 vs 0.200).
sympy simplification and 1000 random numeric spot checks
Table 2: superscript directions, DS reward improves all metrics over SFT, ECD reward lowers DS, validity reward lowers F and DS, Validity->DS improves all geometry over Validity, F1 reward F < IoU reward F; Valid% consistent with 153 items; 3,203+3,204=6,407
All 25 printed superscripts match recomputed directions; every textual comparison holds; each Valid% maps to a unique k/153 (115,143,130,129,137,133,138); 3203+3204=6407. Context the text omits: the IoU reward beats the DS reward on Valid (93.5 vs 89.5), IoU (0.484 vs 0.445) and F (0.407 vs 0.369), the F1 reward has the best ECD (48.32); the validity-only reward also improves IoU (0.358 vs 0.338) and ECD; Validity->DS reaches DS 0.244, only 0.002 above SFT (0.242).
Recomputed every direction-of-change superscript and textual comparison; GRIM-style check of Valid% against k/153
RQ3 gains do not come from validity alone
The paper does not state how invalid outputs enter the means. If invalid outputs score 0, per-valid DS is 0.322 for SFT and 0.304 for the DS reward (lower even at rounding extremes: 0.3046 < 0.3209), and every RL reward lowers per-valid DS (IoU -0.041, F1 -0.028, ECD -0.061, Validity->DS -0.051); per-valid F rises only +0.004 under the DS reward. Under that reading the DS-reward gains in F and DS are explained by validity. If means are over valid outputs only, the table supports the claim. The convention must be stated.
Recomputed per-valid IoU/F/DS under the two possible conventions for invalid outputs (invalid scored 0 vs. means over valid outputs only), with rounding bounds
DS selection reaches 4.7%, 17.2%, 13.0% of Oracle gain on IoU, CD, F-score and outperforms the baseline on most metrics
From the printed values: IoU 5.1% (rounding range 4.6-5.6%, claimed 4.7% attainable), CD 17.2% (17.1-17.4%), F 12.8% (12.3-13.3%, claimed 13.0%). DS selection improves IoU, CD, F, DS but worsens ECD (31.79 -> 33.47, -11.8% of Oracle gain), i.e. 3 of 4 non-DS metrics. Absolute IoU gain is +0.010 on 20 cases with no CI.
Recomputed (sel-mean)/(oracle-mean) from Table 3, with all rounding combinations of the printed entries